Page 1: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

New ALICE Beam Pipe: Injection Protection

C. Bracco on Behalf of ABT/BTPAcknowledgment: M. Giovannozzi

Page 2: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Outlines

• Reminder• Assumptions• Aperture and beam envelope:– Nominal injection– Grazing event (MKI failure)– Mis-injection

• Conclusions

Page 3: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Reminder

Page 4: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Reminder

To protect the LHC aperture at injection (bottleneck in the arc) and respect the collimation hierarchy:• LHC injection protection

collimators (TDI, TCLIA and TCLIB) ar at 6.8 s

• TCDI (in the TL) are at 4.5 – 5 s

Page 5: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

MG - TREX meeting 5

0

5

10

15

20

25

30

35

40

-20 -15 -10 -5 0 5 10 15 20

n1 (s

)

Distance from IP (m)

Beam 1 - Nominal - Inj

Beam 1 - After LS2 - Inj

Beam 1 - After LS2 Rev 2 - Inj

18/07/2014

Alice aperture: results - I

b*=10 mqext=170 mradSep=2 mm

0

5

10

15

20

25

30

35

40

-7 -5 -3 -1 1 3 5 7

n1 (s

)

Distance from IP (m)

Beam 1 - Nominal - Inj

Beam 1 - After LS2 - Inj

Beam 1 - After LS2 rev 2 - Inj

M. Giovannozzi

4 s bottleneck in the experiment

Minimum aperture = 13 s (bottleneck in the arc)

Ok!...check MKI grazing failure..

Page 6: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Reminder

90% MKI strength

10% MKI strength

Page 7: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Assumptions• Normalised emittance of 3.5 mm mrad also for postLS2 case

• Optics for protons (minimum n1):b* = 10 m, crossing angle = 170 mrad , separation =2 mm

• Beam envelope: 6.8 sb (what can go through TCDIs and TDI) + 20% beta-beating

• Aperture: Mech.aperture* – Mech.tol.* – Orbit** – Disp.offset***

* Data from ALICE and Massimo** 4 mm *sqrt(b/max(b)) *** Dy*3e-4

Page 8: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Aperture and Beam Envelope PreLS2

TDI

TDI

Nominal kick

Page 9: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Aperture and Beam Envelope PostLS2

TDI

TDI

Nominal kick

Page 10: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Phase Advance Min. Aperture- MKI

Page 11: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Grazing Event (Vertical)

TDI

TDI

Nominal MKI kick

grazing (10% MKI kick)

Page 12: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Grazing Event (Vertical)

TDI

TDINominal MKI kick

grazing (10% MKI kick)

20 sigma

Page 13: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Mis-injection (Horizontal)

Nominal

Mis-injection:x0 = 2.5 mmx0’= 30 urad

Mis-injection:x0 = 2.5 mmx0’= 30 urad

15 sigma

Page 14: New ALICE Beam Pipe: Injection Protection C. Bracco on Behalf of ABT/BTP Acknowledgment: M. Giovannozzi.

Conclusions

• The new proposed aperture fulfills the n1 requirements of collimation hierarchy: bottleneck kept in the arc and > 7.5 s

• No direct beam impact on the new aperture is expected also in case of the most critical MKI failure (grazing event) or mis-injection


Recommended