+ All Categories
Home > Documents > NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase...

NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase...

Date post: 15-Mar-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
20
2020 - 2021 NEW & FEATURED SOLUTIONS HEAT INSULATE alliancets.com 630-321-9646 ENERGY EFFICIENCY•PROTECTION NEW! NEW! PIPES• TANKS•DRUMS•& MORE YES WE HEAT THAT! MAINTAIN PROCESS & TEMPERATURE CONTROL
Transcript
Page 1: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

2020 - 2021

NEW & FEATURED SOLUTIONS

HEAT

INSULATE

alliancets.com

630-321-9646

ENERGY EFFICIENCY•PROTECTION

NEW!

NEW!

PIPES• TANKS•DRUMS•& MORE

YESWE HEATTHAT!

MAINTAIN PROCESS & TEMPERATURECONTROL

Page 2: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

2 630-321-9646 alliancets.com

NEW!

Cut-to-length heat trace cable for freeze protection and temperature maintenance up to 149°F (65°C)

Kit Enough to Complete Part No.

Power Connection Kit w/Junction Box PTBO-GET

End Seal Kit One end seal termination JHE-GET

Splice Connection Kit One splice connection JHS-GET

Tee Connection Kit One tee connection JHT-GET

End of circuit LED monitor light kit One end-of-circuit JHE-LG-GET

Kit Enough to Complete Part No.

Power Connection Kit

One input power connection and one end seal connection*

SLCBLUC

Ground Fault Power Connection Kit

One ground-fault protection power input connection

SLCBLUC-GF

End Seal Kit Two end seal terminations

SLCBLKC

Splice and Tee Kit One splice or tee connection and one end seal termination

SLCBLSK

Connection/Termination Kits for Ordinary Locations – UL Approved

Outer Jacket

Tinned Copper Braid

Thermoplastic Elastomer

Watts /Foot Part No.

120 VAC

5

8

10

5

8 SLCBL8120BP

10 SLCBL10120BP

Connection/Termination Kits for Ordinary and Hazardous Locations - CSA Approved

Type NPT Size Part No.

Metallic Junction Box– 3 Hub ½ in JBM050

Pipe Straps – Adjustable from 2 to 6 in BPSCAB2-6

Junction Box and Pipe Straps Junction box includes watertight cover

SLCBL5120B

SLCBL8120B

SLCBL10120B

SLCBL5120BP

Standard Spool Sizes: 50 ft, 100 ft, 125 ft, 150 ft, 250 ft, 500 ft, 1000 ft. For orders greater than 10,000 ft, call for pricing.

• Automatically adjusts heat output based on surface temperature • Can be cut-to-length and terminated in the field • Safe to overlap and insulate • Optional thermoplastic elastomer over-jacket for wet environments • Fluoropolymer over-jacket also available upon request for strong chemical environments

Ordinary Locations

Class 1 Division 1 Heating Cable and other voltages available upon request

Ordinary and Hazardous Locations: Class I, Div. 2, Groups A, B, C, D Class II Div. 2, Groups E, F, GClass III

Need an insulator? See pages 9 & 16

Self-Regulating Heating Cable

• Temperatures up to 500°F (260°C) • Ideal for process temperature applications where

a specific temperature is required: power remains constant regardless of ambient temperature

• Models available that are suitable for harsh, corrosive, and hazardous-area environments • Can be cut-to-length and terminated in the field

Ordinary LocationsHazardous LocationsClass I, Division 2, Groups B, C, & DClass II, Division 2, Groups F & GClass III, Division 2

Constant-Wattage Heating Cable

Voltage Watts/Foot Part No.

120 - 480 3 to 18 Contact Us for a Quote

NEW!

*Junction box and pipe straps sold separately

One input power connection

Page 3: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

3alliancets.com

630-321-9646

Ideal for melting snow and de-icing roofs, gutters, and downspouts

SpeedTrace Roof and Gutter De-icing Kits • Durable, long lasting professional-grade self-regulating heating cable • Suitable for residential, commercial, and industrial roofing applications • Easy-to-install: pre-assembled with 3-prong grounded plug (NEMA 5-15P) • Kits include: Speedtrace heating cable, downspout hanger brackets, roof clips, and UV resistant ties

SpeedTrace Pre-Assembled Self-Regulating Heating Cable

Cable Length (ft) Part No.120 VAC

50 FFRG15-50

100 FFRG15-100

150 FFRG15-150

• Automatically adjusts heat output based on surface and ambient temperature • Easy-to-install: pre-terminated with 3-prong grounded plug (NEMA 5-15P)• Several heater lengths to choose from

Speedtrace 5 watts/ft @ 50°F (10°C)

SpeedTrace Extreme 8 watts/ft @ 50°F (10°C)

Power-saving ambient temperature sensing outlet• Turns on when air temperature drops below 35°F (2°C)• Turns off when air temperature exceeds 45°F (7°C)• Saves energy/money and extends the life of the heater• Suitable for indoor/outdoor use

Thermo-Cube Thermostatically Controlled Outlet (PN: THERMO-CUBE)

HEATPIPES • VESSELS • ROOF & GUTTER

Length(ft)

Part No.120 VAC

6 FFSL1-6

12 FFSL1-12

18 FFSL1-18

24 FFSL1-24

50 FFSL1-50

100 FFSL1-100

Length(ft)

Part No.120 VAC

6 FFSL81-6

12 FFSL81-12

18 FFSL81-18

24 FFSL81-24

50 FFSL81-50

100 FFSL81-100

PLUG and

PLAY

60% MORE

WATTAGE

Complete kit includes everything you need!

Page 4: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

4 630-321-9646 alliancets.com

Mineral Insulated (MI) Heating Cable • High temperature capabilities up to 1832°F (1000°C) • High maximum watt densities up to 76.2 watts per foot • Laser welded for superior reliability • Choice of outer sheath materials: Stainless steel, Alloy 800/825,

and Inconel 600 • Water proof and high corrosion resistance - IP 67 rated • Custom-made to your exact requirements

Evapoway Anti-Condensate Pans • Corrosion resistant 22 gauge stainless

steel pan • Space-saving design • Multiple sizes, wattage options, and

dissipation rates available • High-limit safety and float switch

operation • 3 ft long power cord with grounded

3-prong plug (NEMA 5-15P)

Other sizes available

Provides solution when no drain is available in commercial refrigeration units, elevators, and HVAC units

Pan Size (in)

(L x W x H)

Capacity (Quarts) Watts

Dissipation Rate (Liters per day)

Part No. 120 VAC

10 x 7 x 2.5 1.75 200 1.5 DM02T-1S 400 3.5 DM04T-1S

13 x 7 x 2.5 2.37 600 4.5 DM06S-1S

800 6 DM08S-1S13 x 7 x 4 4 1000 8 DM10M-1S

13 x 10 x 4 7 1000 8 DM10W-1S 1500 12 DM15W-1S 1800 14 DM18W-1D

13 x 10 x 6 10 1800 14 DM18X-1D21 x 13 x 4 15 1000 8 DM10WW-1D

1500 12 DM15WW-1D21 x 13 x 6 21 1800 14 DM18XX-1D

Part No. Circumference(in)

Voltage Wattage Lead Length

840051001 15.3 to 22 240 40 21

840051002 20.5 to 27.1 240 40 21

840051004 21.3 to 28 480 70 22

840051006 21 to 28 240 70 48

840051007 27.3 to 34 240 93 48

840051008 27.3 to 34 480,400 93,66 48

840051010 27.3 to 34 230 66 48

840051009 39.5 to 46.1 230 95 29

HB1001 120 NEMA 5-15P 200

HB2001 240 NEMA 6-15P 200

Band-Style Crankcase Heaters for HVAC/R Compressors • Protects A/C and heat pump compressors in

cold weather • Easy to Install • Rapid heat-up • Moisture-proof • Corrosion-resistant • Grounded for safety

NEW!

Part No. Voltage Plug Type Watts

Jug Warmer • Pre-heat and keep refrigerant

jug cylinders warm when servicing HVACR systems in cold weather

• Ideal for portable field service and outdoor use

• Adjustable fit design with hook & loop strap fits com-mon size cylinders: 30 lb, 50 lb, and 125 lb

• Preset 120°F (49°C) built-in thermostat with patented grounded heating element

HotBelt™ Wrap-Around Refrigerant

Temperature Control Required

Description Part No.

Configure-to-order Call today for your quote

Page 5: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

5alliancets.com

630-321-9646

Temperature Control Required

Don’t Forget Your Insulation! Options on Pages 9 & 16

XtremeFLEX® Silicone Rubber Heating Tape with Adjustable Thermostat Control

Description Part No.

Fiberglass adhesive tape – 1/2 in x 36 yd roll - temperature limit 350°F (176°C)

PSAT36A

GFCI Adapter— Converts standard outlet into a GFCI protected outlet. 120 VAC, max 15A.

GFCI01

Description Part No.

Fiberglass adhesive tape – 1/2 in x 36 yd roll - temperature limit 350°F (176°C)

PSAT36A

GFCI Adapter— Converts standard outlet into a GFCI protected outlet. 120 VAC, max 15A.

GFCI01

XtremeFLEX® Silicone Rubber Heating Tape with Preset Thermostat

Accessories – Adhesive tape to install heating tape to surface to be heated

• Extremely flexible heating tape with pre-set thermostat: 70°F or 120°F (21°C or 49°C)

• Ideal for freeze protection and process control heating applications • Moisture and chemical resistant — IP66 rated • 5 ft long power cord with 2-prong plug (NEMA 1-15P)

• Extremely flexible — Heats a wide range of objects quickly • Adjustable thermostat control — Choice of two temperature ranges: Up to 160°F and

425°F (71°C and 218°C) • Moisture and chemical resistant — IP54 rated • 6 ft long power cord with 2-prong plug (NEMA 1-15P)

Length(ft)

Width(in)

TemperatureRange

Part No.120 VAC

Part No.

2 1 144 MSTAT101002

4 1 288 MSTAT1010046 1 Up to 160°F 432 MSTAT1010068 1 (71°C) 576 MSTAT101008

10 1 720 MSTAT1010102 1 144 HSTAT1010024 1 288 HSTAT1010046 1 Up to 425°F 432 HSTAT1010068 1 (218°C) 576 HSTAT101008

10 1 720 HSTAT101010

Accessories – Adhesive tape to install heating tape to surface to be heated

PLUG & PLAYBUY THEM•PLUG THEM IN • START HEATING

Length(ft)

Width(in)

ThermostatSetting

Watts Part No.120 VAC

10 ½ 60 RKP1A0120

20 ½ 120 RKP1A024060 ½ 70°F 360 RKP1A0720

100 ½ (49°C) 600 RKP1A1200125 ½ 750 RKP1A150010 ½ 60 RKP1B0120

20 ½ 120 RKP1B024060 ½ 120°F 360 RKP1B0720

100 ½ (21°C) 600 RKP1B1200125 ½ 750 RKP1B1500

Page 6: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

6 630-321-9646 alliancets.com

Ideal solution for keeping contents warm inside intermediate bulk containers

NEW! Wet-area Wrap-around Tote Tank/IBC Heaters

Certified to UL safety standards

Heater Size Watts Part No. 120 VAC

32 x 36 in 1600 TTH32361DK

Silicone Tote Tank/IBC Heaters

• Installs underneath plastic bladder for direct surface contact – provides quicker heat-up time • 32 x 36 in silicone rubber heater with ½ in thick foam insulation • Moisture and chemical resistant • Includes digital on/off temperature controller • Type K thermocouple sensor built into heater

Digital Temperature Controller Included

ATEX Hazardous-area IBC/ Wrap-around Container Heater • Robust construction for indoor

and outdoor use — IP 65 • Temperatures up to 392°F

(200°C)

• Two built-in PT100 sensors • 230 VAC • 10 ft power cord with crimped

ferrule terminated leads

NEW!

ATEX Hazardous-area Digital ControllerRequired with ATEX IBC Heater. See page 9 for details.

Part No.

WEXRBL25-230ZESBH

Part No. 120 VAC

Size(gal)

Heater Height

(in)

Tank Size Minimum

(in)[length x width]

Tank Size Maximum

(in)[length x width]

Watts

TOTE361-ADJV 170 - 250 36 40 x 40 48 x 48 1440

TOTE421-ADJV 275 42 40 x 40 48 x 48 1440

TOTE481-ADJV 330 48 40 x 40 48 x 48 1440

• Adjustable thermostat control: Up to 160°F (71°C) • Two separate heat zones allow users to adjust heater

output as content levels decrease • Adjustable buckles allow heater to fit several sizes of

caged, plastic, and metal tote tanks/IBCs

• Built-in high-limit safety thermostat set at 195°F (91°C) • 6 ft long power cord with grounded 3-prong plug

(NEMA 5-15P)

Original Wrap-around Tote Tank/IBC Heaters

• Extra-durable, water-resistant design for indoor/outdoor use and in wash-down environments — IP 54

• Easy-to-use digital controller: Adjustable up to 140°F (60°C)

• Lightweight and easy to install with adjustable buckles

• Built-in high-limit thermostat: 185°F (85°C)

• 6ft long power cord with grounded 3-prong plug (NEMA 5-15P)

Part No.

TOTEW-TOPFV

Insulating top coverMinimizes heat loss. Fits all sizes

Part No.

TOTE-TOPFV

Insulating top coverMinimizes heat loss. Fits all sizes

Part No. Size Wattage

WEXHCIBC-230ZE100-0440BHT3 275 gal 2400

Gas II 2G Ex e mb IIC T3 Gb

Dust II 2D Ex e mb IIIC T120°C Db

-40°C ≤ Ta ≤ +60°C ambient temperature

Part No. 120 VAC

Size(gal)

Heater Height

(in)

Tank Size Minimum

(in)[length x width]

Tank Size Maximum

(in)[length x width]

Watts

TOTEW361-ADJV 170 - 250 36 40 x 40 48 x 48 1440

TOTEW421-ADJV 275 42 40 x 40 48 x 48 1440

TOTEW481-ADJV 330 48 40 x 40 48 x 48 1440

Page 7: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

7alliancets.com

630-321-9646

IBC/Tote Tank Immersion Heaters • Maximum thermal efficiency- Twice the heat-up rate compared to standard wrap-around heaters*

• Easy installation/universal fit-screws directly into top of tank

• Adjustable control

• Grounded for safety

• Ideal for non-acidic materials

• 2 in NPS bushing included

• 10 ft long power cord with grounded 3-prong plug (NEMA 5-15P)

• IP55

HeatingElement

*When paired with insulator

Voltage Wattage Length Part No.

120 1500 34 in TTI120

IBC/Tote Tank Insulators

Insulator Cover with Center Access Port

(sold separately)

NEW!

NEW!

Height(in)

Capacity(gal)

Tank PerimeterMinimum

(in)

Tank Perimeter Maximum

(in)

Part No.

36 175-250 160 192 TOTEW36IV

42 275 160 192 TOTEW42IV

48 330 160 192 TOTEW48IV

• Designed for indoor /outdoor or washdown locations • Easy-to-install — Just select height or capacity • Universal fit • Removable and reusable

Description Part No.

Optional insulated top cover TOTEW-TOPFV

HEATIBCs•TOTE TANKS

Page 8: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

8 630-321-9646 alliancets.com

Maximize heat efficiency and heat-up time

Certified to UL safety standards

Heavy-duty Silicone Rubber Drum Heaters

Description Part No.

Replacement spring 10180

Accessories

ATEX Hazardous-area Drum Heater• Robust construction for indoor and

outdoor use – IP 65• Temperatures up to 356°F• Two built-in PT100 sensors

• 230 VAC• 10 ft power cord with crimped ferrule

terminated leads

NEW!

ATEX Hazardous-Area Digital ControllerRequired with ATEX Drum Heater. See page 9 for details

Part No.

WEXRBL25-230ZESBH

NEW!

• Extra-durable, water-resistant design for indoor/outdoor use and in wash-down environments — IP 54

• Easy-to-use digital controller: Adjustable up to 140°F (60°C)

• Lightweight and easy to install with adjustable buckles • Built-in high-limit thermostat: 185°F (85°C)• 6 ft long power cord with grounded 3-prong plug

(NEMA 5-15P)

Part No.120VAC

Part No.240VAC Size Diameter Height Watts

FGPDHWC55120DV FGPDHWC55240DV 55 gal 22.3 in 36.4 in 600

NEW! Wet-area Full-coverage Drum Heater

Part No.

FGDWC55V

Insulating top coverWet-area insulating cover, minimizes heat loss

Part No. Drum Size(gal)

Drum Diameter(in)

Drum Type Temp. Range Watts

FGDHC55120DV 55 22.3 Metal Up to 450°F (232°C)

1600

FGPDHC55120DV 55 22.3 Plastic Up to 160°F (71°C)

770

Original Full-coverage Drum Heater • Easy-to-use digital temperature controller • Hook and loop fastener for easy

on/off installation

• 1 in thick insulation • 6 ft long power cord with grounded

3-prong plug (NEMA 5-15P)

Part No.

FGDC55V

Insulating top coverDrum Insulation Cover for 55 gallon

Part No. Size Wattage

XHD200-230ZE800-021BHT3 55 gal 1200

Gas II 2G Ex e mb IIC T3 Gb

Dust II 2D Ex e mb IIIC T120°C Db

-40°C ≤ Ta ≤ +60°C ambient temperature

Drum Size(gal)

Drum Diameter(in)

Drum Type

Temperature Range

Watts Part No.

5 11.1 to 12.1

Metal Up to 450°F(232°C)

550 DHCS10

15/16 14.0 to 15.0 700 DHCS11

30 18.6 to 19.6 1000 DHCS13

55 22.3 to 23.2 1200 DHCS15

5 11.1 to 12.1

Metal Up to 160°F(71°C)

550 DHLS10

15/16 14.0 to 15.0 700 DHLS11

30 18.6 to 19.6 1000 DHLS13

55 22.3 to 23.2 1200 DHLS15

5 11.1 to 12.1

Poly Up to 160°F(71°C)

150 DPCS10

15/16 14.0 to 15.0 200 DPCS11

30 18.6 to 19.6 250 DPCS113

55 22.3 to 23.2 300 DPCS15

• 4 in wide silicone rubber band heater with adjustable thermostat control • Moisture and chemical resistant – IP 54 rated • 6 ft long power cord with grounded 3-prong plug (NEMA 5-15P)

Page 9: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

9alliancets.com

630-321-9646

ATEX Hazardous-area Digital Controller with Limiter

• Approved to zones 1/2 (gas) and 21/22 (dust) • Clear glass window for easy reading

of temperature display • Large connection box

• Measuring range: up to 842°F (450°C) • With 2 built-in 3 m Pt100 sensors • Rated at 25 amps • Voltage: 230 VAC • Power cord and plug required

Part No. Temperature Range

WEXRBL25-230ZESBH Up to 842°F (450°C)

NEW!

Environment Cylinder Size(in)

Watts Part No.

Ordinary Location8 x 48 150 GCW8481501

9 x 51 150 GCW951150115 x 43 150 GCW15431501

Hazardous-Area8 x 48 150 HCW8481501

9 x 51 150 HCW9511501

15 x 43 150 HCW15431501

Improves process control and reduces waste of condensed gas

Gas Cylinder Warmers

• Full surface coverage – Warms entire body of cylinder

• Self-regulating heating element – no additional temperature control needed

• Hazardous-area rated version available • 10 ft long power cord with either

-Standard 3-prong grounded plug NEMA 5-15P (ordinary location version) -Teck 90 cable with bare lead wires (hazardous-area version)

Class I Division 1 Groups B, C, and D (Hazardous-area Model)

INSUL-LOCK® DS Flexible Closed Cell Pipe Insulation

Part No.Recommended Pipe/Tube O.D.

(in)

Inside Diameter of

Insul-Lock® DS(in)

INSUL78 1/2 - 5/8 7/8

INSUL118 3/4 - 7/8 1-1/8

INSUL138 1 1-3/8

INSUL158 1-1/8 1-5/8

INSUL2 1-3/8 2

INSUL218 1-5/8 2-1/8

INSUL238 2 2-3/8

INSUL258 2-1/8 2-5/8

INSUL278 2-3/8 2-7/8

INSUL318 2-5/8 3-1/8

INSUL312 2-7/8 3-1/2

INSUL358 3-1/8 3-5/8

INSUL418 3-1/2 4-1/8

INSUL412 4 4-1/2

• Double-seal technology - Built-in pressure sensitive adhesive - Built-in PVC overlap tape with acrylic

adhesive • 6 ft long • Scrim reinforcement on the seam surface • Environmentally-friendly, CFC-free,

flexible elastomeric thermal insulation

• Non-porous, fiber-free, and resistant

to mold growth • Resistant to

moisture vapor flow • Compatible with

heating cable and tapes

ATEX Hazardous-area Gas Bottle Heaters• Improves process control and

reduces wasted condensed gas

- Creates convection current- Increases pressure inside cylinder

• Robust, flexible and dissipative construction for indoor and outdoor use- IP65

• With 2 built-in 3 m Pt100 sensors

• 392°F (200°C) max operating temperature

• 230 V • Nominal power (10L, 50L,

79L): 380 w; 850 w; 850 w or application specific

• 10 ft power cord with crimped ferrule terminated lead

NEW!

ATEX Hazardous-area Digital Controller is required with ATEX Gas Bottle Heater. See below for details.

Gas II 2G Ex e mb IIC T3 Gb

Dust II 2D Ex e mb IIIC T120°C Db

-40°C ≤ Ta ≤ +60°C ambient temperature

Part No. Capacity (lit)

WEXHB010-230ZE140-0080BHT3 10

WEXHB050-230ZE230-0140BHT3 50

WEXHB079-230ZE318-0100BHT3 79

Gas II 2G Ex e mb IIC T3 Gb

Dust II 2D Ex e mb IIIC T120°C Db

-40°C ≤ Ta ≤ +60°C ambient temperature

Page 10: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

10 630-321-9646 alliancets.com

HEATTANKS•VESSELS • HOPPERS•& MORE

Heavy-Duty Silicone Rubber Heating Blankets

up to 358°F (181°C)

Silicone Rubber Heating Blankets With Built-in Control • Built -in adjustable thermostats • Plug-and-play design • Exceptional durability and suitable

for a large range of surfaces like tanks, vessels, hoppers, conveyors, and more

• Moisture, chemical, and radiation resistant and grounded for safety

3 Series Options: SRL-ADJ: Up to 425°F (232°C) t/s; 2.5 w/in²

- High Watt Density; High-Temp; For Metal SRP-ADJ: Up to 160°F (71°C) t/s; 1.25 w/in²

- Low Watt Density; Low-Temp; For Poly SRM-ADJ: Up to 160°F (71°C) t/s; 2.5 w/in²

- High Watt Density; Low-Temp; For Increased Heat and Accuracy at Lower Temps

Part Number Matrix SRL 06 12 1 P ADJB Product Series: SRL - (2.5 W/in2), SRP - (1.25 W/in2) SRM - (2.5 W/in2)

Width (inches): Length (inches): Voltage: 1 - (120 V), 2 - (240 V)

Pressure Sensitive Adhesive: P - (with PSA), Blank - (without PSA)

Ordering Options: ADJB - with plug ADJ - no plug, ferrule crimped wire terminations ( Approved)

NEW CUSTOM SHAPES OPTION

Many more sizes and options to choose from. Contact us for a quote.

Temperature Control Required

(see ordering options for details)

• Exceptional durability and suitable for a large range of surfaces like tanks, hoppers, conveyors, silos, and more

• Moisture and chemical resistant – IP66 rated• Maximum exposure temperature up to

450°F (232°C)

• 48 in silicone rubber power cord with bare wire (no plug)

• Optional pressure sensitive adhesive (PSA) backing for easy installation on a wide range of surfaces

With PSA Backing

Size(in)

SurfaceType

Watts Part No. 120 VAC

Part No. 120 VAC

6 x 12 180 SRL06121 SRL06121P

6 x 24 360 SRL06241 SRL06241P

6 x 36 540 SRL06361 SRL06361P

12 x 12 Metal 360 SRL12121 SRL12121P

12 x 24 720 SRL12241 SRL12241P

24 x 24 1440 SRL24241 SRL24241P

24 x 36 2160 SRL24361 SRL24361P

6 x 12 90 SRP06121 SRP06121P

6 x 24 180 SRP06241 SRP06241P

6 x 36 270 SRP06361 SRP06361P

12 x 12 Poly 180 SRP12121 SRP12121P

12 x 24 360 SRP12241 SRP12241P

24 x 24 720 SRP24241 SRP24241P

24 x 36 1080 SRP24361 SRP24361P

Size(in)

6 x 12

6 x 24

6 x 36

12 x 12

12 x 24

12 x 36

18 x 18

18 x 36

24 x 24

Page 11: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

11alliancets.com

630-321-9646

Size(in)

Watts Part No. 120 VAC

3 x 30 450 SRW030-300A010A00-UR

3 x 40 600 SRW030-400A010A00-UR

4 x 4 80 SRW040-040A010A00-UR

4 x 15 300 SRW040-100A010A00-UR

4 x 20 400 SRW040-200A010A00-UR

4 x 30 600 SRW040-300A010A00-UR

4 x 40 800 SRW040-400A010A00-UR

5 x 10 250 SRW050-100A010A00-UR

5 x 20 500 SRW050-200A010A00-UR

5 x 30 750 SRW050-300A010A00-UR

5 x 40 1000 SRW050-400A010C00-UR

6 x 10 300 SRW060-100A010A00-UR

6 x 20 600 SRW060-200A010A00-UR

6 x 30 900 SRW060-300A010A00-UR

6 x 40 1200 SRW060-400A010C00-UR

Size(in)

Watts Part No. 120 VAC

1 x 4 20 SRW010-040A010A00-UR

1 x 10 50 SRW010-100A010A00-UR

1 x 20 100 SRW010-200A010A00-UR

1 x 30 150 SRW010-300A010A00-UR

1 x 40 200 SRW010-400A010A00-UR

1 x 80 400 SRW010-800A010A00-UR

2 x 5 50 SRW020-050A010A00-UR

2 x 10 100 SRW020-100A010A00-UR

2 x 20 200 SRW020-200A010A00-UR

2 x 30 300 SRW020-300A010A00-UR

2 x 40 400 SRW020-400A010A00-UR

3 x 3 45 SRW030-030A010A00-UR

3 x 5 75 SRW030-050A010A00-UR

3 x 10 150 SRW030-100A010A00-UR

3 x 20 300 SRW030-200A010A00-UR

Standard-Duty Silicone Rubber Heating Blankets

Many more sizes and options to choose from. Contact us for a quote. Temperature Control Required

•CUSTOM CONFIGURATIONS •HAZARDOUS-AREA RATED •WITH BUILT-IN CONTROL •ANY SIZE • ANY SHAPE •CUT-OUTS, NOTCHES & HOLES

Hazardous-Area Rated Silicone Rubber Heating Blankets • Hazardous-area rated for T3 or T4A environments • Exceptional durability and suitable for a large range of surfaces like tanks,

hoppers, conveyors, silos, and more • Built-in 3/4–14 NPSM conduit fitting protects electrical wiring (conduit sold

separately) • Moisture and chemical resistant – IP54 rated • 12 in silicone rubber power leads with bare wire (no plug) • Optional pressure sensitive adhesive (PSA) backing for easy installation on a

wide range of surfaces

Class I, Div. 2, Groups A, B, C, D Class II Div. 2, Groups F, G Zone 2/22

Many more sizes and options to choose from. Contact us for a quote.

Temperature Control Required

• Standard durability and suitable for a large range of surfaces like tanks, hoppers, conveyors, silos, and more

• Thin low-profile design • Moisture and chemical resistant – IP66 rated • Maximum exposure temperature up to 450°F (232°C) • 10 in PFA extruded power leads with bare wire (no plug) • Optional pressure sensitive adhesive (PSA) backing for easy

installation on a wide range of surfaces

SILICONE HEATERS TO MEET ANY APPLICATION AND BUDGET

With PSA BackingWith PSA Backing

Size(in)

SurfaceType

Watts Part No. 120 VAC

Part No. 120 VAC

6 x 12 180 SRX06121801T3 SRX06121801PT3

12 x 12 T3 360 SRX12123601T3 SRX12123601PT3

12 x 24 720 SRX12247201T3 SRX12247201PT3

6 x 12 90 SRX06121801T4A SRX06121801PT4A

12 x 12 T4A 360 SRX12123601T4A SRX12123601PT4A

12 x 24 720 SRX12247201T4A SRX12247201PT4A

Page 12: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

12 630-321-9646 alliancets.com

Thermostat Setting

Open/Close °F (°C)Heater Size

(in) Watts Part No. 120 VAC

60/40(15/4)

2.5 x 6 60 TSREH6402.5 x 12 120 TSREH1240

No thermostat 2.5 x 6 60 TSREH600

2.5 x 12 120 TSREH1200

Aluminum Foil Heaters • Low cost solution • Custom shapes and sizes • Built to exact requirements • Sheath temperatures up to 300°F (149°C)

Up to 60% Lower Cost Than Silicone Heaters

For custom heater design assistance contact us today.

Prevents condensation or freezing of electronics within enclosures and control panels

Enclosure Heaters • Silicone rubber heater on an easy-to-install

aluminum mounting plate – two mounting slots that are ¼ x 5/32 in centered on a ½ in flange

• Built-in air-sensing thermostat • Moisture and chemical resistant • 4 ft long power leads

Also available with other thermostat options and 240 V

NEW!

Temperature Control Required

Part No. Size(in)

Voltage Watts Leads

FHB0200600001 2 x 6 120 25 18 in bare wire leads

FHB0400600003 4 x 6 120 60 18 in bare wire leads

FHB0201000005 2 x 10 120 50 18 in bare wire leads

FHB0401000001 4 x 10 120 110 18 in bare wire leads

FHB0601000007 6 x 10 120 170 18 in bare wire leads

FHB0201200003 2 x 12 120 60 18 in bare wire leads

FHB0401200001 4 x 12 120 130 18 in bare wire leads

FHB0601200002 6 x 12 120 205 18 in bare wire leads

FHB0602400001 6 x 24 120 420 18 in bare wire leads

Page 13: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

13alliancets.com

630-321-9646

Temperature Control Required

Flask Size (ml)

Total Watts

Part No. 120 V

100 110 HM0100MS1

250 165 HM0250MS1

500 220 HM0500MS1

1000 325 HM1000MS1

Tape Width (in)

Tape Length (ft) Watts

Part No. 120 V

1/2 2 52 BS0051020L

1/2 4 104 BS0051040L

1/2 6 156 BS0051060L

1/2 8 209 BS0051080L

1 2 104 BS0101020L

1 4 209 BS0101040L

1 6 313 BS0101060L

1 8 418 BS0101080L

Heating Mantle with Built-in Control and Magnetic Stirrer

• Built-in time percentage temperature controller

• Built-in magnetic stirrer

• Operating temperatures up to 842°F (450°C )

NEW!

Heating Mantle with Built-in Control • Built-in time percentage temperature

controller • Operating temperatures up to 842°F

(450°C ) • Plug-and-play design

XtremeFLEX® High Temperature Heating Tapes • Highly flexible and durable • High watt density for rapid thermal response • Maximum exposure temperature

- Remove and reinstall 572°F (300°C) - Single install 932°F (500°C)

XtremeFLEX® Silicone Rubber Heating Tapes • Moisture and chemical resistant • Exceptionally flexible • Maximum exposure temperature 450°F (232°C)

Other standard sizes and voltages available

Temperature control required for all tapes

Flask Size (ml)

Total Watts

Part No. 120 V

50 55 HM0050MC1

100 100 HM0100MC1

250 150 HM0250MC1

500 200 HM0500MC1

1000 300 HM1000MC1

2000 500 HM2000MC1

3000 600 HM3000MC1

4000 750 HM4000MC1

5000 860 HM5000MC1

6000 1000 HM6000MC1

HEATLABORATORY • R&D • & MORE

Tape Width

(in)

Tape Length

(ft)Watts Part No.

120 V

1 1 105 BIH101010L

1 2 210 BIH101020L

1 4 420 BIH101040L

1 6 620 BIH101060L

1 8 830 BIH101080L

1 10 1045 BIH101100L

1 12 1250 BIH101120L

Page 14: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

14 630-321-9646 alliancets.com

Band and Nozzle Heaters • Premium grade mica insulation • High-temperature electrogalvanized steel sheath • Maximum operating temperatures up to 850°F (454°C) • Electrical connection:

- Band Heaters: Screw terminals - Nozzle Heater: 10 in long leads

Barrel Diameter

(in)

Width(in)

Watts Part No. 240 VAC

3.5 1 300 BA035-010B

3.5 1.5 500 BA035-015C

3.5 2 500 BA035-020B

4 1 625 BA040-010B

4 2 800 BA040-020E

4 4 1250 BA040-040A

4.5 2.5 1000 BA045-025A

5 1.5 750 BA050-015E

6 1.5 850 BA060-015E

6 2 1000 BA060-020A

7 1.5 1100 BA070-015C

8 2 1500 BA080-020A

9 1.5 1300 BA090-015B

10 1.5 1400 BA100-015A

12 2 2300 BA120-020A

Nozzle Diameter

(in)

Width(in)

Watts Part No. 240 VAC

1 1 100 NZ1010-20100

1 1.5 150 NZ1015-20150

1 2 200 NZ1020-20200

1.5 1 150 NZ1510-20150

1.5 1.5 300 NZ1515-20300

1.5 2 300 NZ1520-20300

2 1.5 300 NZ2015-20300

2.5 1.5 350 NZ2515-20350

Heater Length(in)

Watts VoltsPart No.

1.5 150 240 HR25015AU

1.5 200 240 HR25015N

2 100 120 HR25020N

2 150 240 HR25020Q

2 200 240 HR25020S

2 250 240 HR25020U

3 300 240 HR25030L

4 200 240 HR25040L

4 300 240 HR25040N

6 400 240 HR25060S

Heater Length(in)

Watts VoltsPart No.

1.25 150 240 HR37012M1.5 150 120 HR37015P

1.5 200 240 HR37015S

1.5 250 240 HR37015Y

2 150 240 HR37020N

2 200 240 HR37020T

2 250 240 HR37020U

2 300 240 HR37020W

3 250 120 HR37030Z

3 300 240 HR37030AC

3 500 240 HR37030AG

4 400 240 HR37040AE

4 500 240 HR37040AF

5 300 240 HR37050X

5 500 240 HR37050Z

6 500 240 HR37060AA

8 1000 240 HR37080AB

10 1000 240 HR37100K

Heater Length(in)

Watts VoltsPart No.

1.25 150 240 HR50012H1.5 200 240 HR50015E2.5 500 240 HR50025AA

3 250 240 HR50030R3 300 240 HR50030T3 500 240 HR50030W4 300 240 HR50040V4 500 240 HR50040Y4 750 240 HR50040Z5 350 240 HR50050AJ5 500 120 HR50050P5 500 240 HR50050R5 750 240 HR50050S5 1000 240 HR50050T6 500 240 HR50060X6 750 240 HR50060Z6 1000 240 HR50060BZ7 1000 240 HR50070H8 500 240 HR50080Y8 1000 240 HR50080Z

10 500 240 HR50100M10 1000 240 HR50100Q12 1000 240 HR50120L14 1000 240 HR50140C16 1000 240 HR50160N

Provides high temperatures necessary to heat resins for extrusion, injection, and blow-molding machinery

Cartridge Heaters • Swaged for greater thermal conductivity • Ideal for heating tools, molds, dies, tanks, vessels,

and more

1/4 in Diameter

Thousands of configurations available for immediate shipment

Band Heaters

Nozzle Heaters

Temperature Control Required

• 304 stainless steel sheath • 10 in long high-temperature DuraFlex lead wires

– maximum exposure up to 1022°F (550°C)

3/8 in Diameter 1/2 in Diameter

Page 15: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

15alliancets.com

630-321-9646

• Ability to heat and insulate all components of a system - Diameters as small as ¼ in - Flanges, pumps, valves, unistrut, etc. • Uniform temperatures throughout entire line or component • Easy on-off installation with durable and reusable hook and loop

fasteners • High temperature capabilities

- Up to 482°F (250°C) for Class 10 Clean rooms - Up to 1100°F (593°C) for Class 100 Clean rooms • Energy efficient design • 360°grounded heating element for applications up to 356°F (180°C) • Exceptional durability

Benefits• Efficient and uniform heat for a wide range of applications• Increased productivity• Decreased maintenance costs• Energy-savings• Safe and cool to the touch• Long service life: BriskHeat's typical heating jacket life is 10+ years.• No need for aftermarket parts

Cloth Heating Jackets

• Piping• Valves• High vacuum components• Tanks, drums, cylinders and vessels• Laboratory equipment

• Vacuum bake-out• Emission testing• Fluid delivery systems• Small and unique geometries • Analytical equipment

• Gas lines • Exhaust lines • Forelines • Abatements• And more

Configure-to-order. Call today for your quote!

Description Part No.

Configure-to-order Call today for your quote

Applications

Page 16: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

16 630-321-9646 alliancets.com

INSULATEENERGY EFFICIENCY•PROTECTION

Energy-Efficient, Modular Insulator System for Your Pipes

• Removable and reusable — Easy-to-install and reuse

• Configurable system for a wide range of pipe and tank systems

• Thermally-efficient fiberglass insulation — 1 in thick

• Exterior material — Polymer-coated fiberglass with temperature rating of 450°F (232°C) higher temperature materials available upon request

• Moisture and chemical resistant — IP 54 rated

Part No. A (ID of Insulator)

SSIP10V 1.00

SSIP15V 1.50

SSIP20V 2.00

SSIP30V 3.50

SSIP40V 4.00

Straight pipe insulators can be cut-in-the-field

Part No. A(ID of Insulator)

B(Height)

SSI9010V 1.25 5.00

SSI9020V 1.50 7.00

SSI9030V 3.50 8.50

SSI9040V 4.50 11.00

Part No. A(ID of Insulator)

B(Length)

SSIC10V 3.17 3.25

SSIC20V 4.00 3.88

SSIC30V 5.25 4.00

SSIC40V 6.80 3.88

Part No. A(ID of Insulator)

B(Length)

SSIF10V 4.25 8.00

SSIF15V 5.00 8.00

SSIF20V 6.00 8.00

SSIF25V 7.00 8.00

SSIF30V 9.00 8.00

SSIF40V 11.25 8.00

Part No.A

(ID of Insulator)

B(Opening ID)

C(Length)

SSIVB102V 4.50 3.00 8.00

SSIVB152V 4.50 3.00 8.00

SSIVB202V 5.25 2.00 8.00

SSIVB302V 7.25 2.50 8.00

SSIVB402V 9.00 2.50 8.00

Silver-Series Cloth Insulators

A

B

A

B

A

Part No.A

(ID of Insulator)

B(ID of

Insulator)C

(Length)

D(Height-

Center-line to top)

SSIT10V 1.50 1.50 8.00 2.00

SSIT20V 2.00 2.75 9.00 2.63

SSIT30V 4.25 3.50 12.00 5.13

Straight Sections (Cut to length)

90° Elbows

Flanges

Tees

2-way Ball Valve

Seam Covers

ID= Inner Diameter

Total usable length for each straight insulator is 83 inches –can be cut-to-length in the field in 6 in and 12 in increments

A

B

A

C

B

C

A

B

D

Need a Custom Insulator? BriskHeat Can Design an Insulator to Meet Your Needs

Don’t Forget INSUL-LOCK® DS Flexible Closed Cell Pipe Insulation on Page 9

Dimensions are in inches

Dimensions are in inchesDimensions are in inches

Dimensions are in inches

Dimensions are in inches

Dimensions are in inches

Page 17: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

17alliancets.com

630-321-9646

• Large 10.1 in touchscreen• User-configurable graphical mapping to application• Global programming and monitoring• Latching alarms for high and low temperature• Send email alerts• Historical graphing of temperature and duty cycle• USB port for firmware updates and download data logs• Modbus communication for remote access

Temperature Control System Set

Other models and voltages available upon request.

PLUGAND

PLAY

• Compact PID control system with autotuning that controls almost any heater

• Everything needed to plug-and-play• 3-button touchpad programming and large 3-digit display• Latching alarms for high and low temperature• Can be used independently or as a system at up to

1,024 zones of control• Each module has up to 7 amp load at 77°F (25°C)

ambient; 4 amp at 104°F (40°C)

• 6 ft power cord with 120V grounded 3-prong plug (NEMA 5-15)

• Heater receptacle: NEMA 5-15R• IP20

LYNX Set Part Number Temperature Sensor

LYNX-SET-JA Type-J Thermocouple

LYNX-SET-KA Type-K Thermocouple

LYNX-SET-RA PT100-RTD Sensor

Optional Operator Interface for Centralized Monitoring

Part No. Description

LYNX-01-10A LYNXTM operator interface with 120 V plug

MAINTAIN PROCESS & CONTROLCONTROL

Description Part No.

Power and communication harness. 12 ft long. Required for connecting operator interface to first LYNX set in a system

LYNX-HN-12A

Accessories

NEW!

Page 18: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

18 630-321-9646 alliancets.com

TC4X Digital Temperature Controllerin NEMA4X Enclosure • Back lit LCD display with 3-button touchpad

interface • NEMA4X/IP67 watertight plastic enclosure • Temperature control range: -40°F to 212°F

(-34C°C to 100°C) • Programmable and displays in °F and °C • Temperature sensor: A99 PTC Sensor 1/4 in

diameter, field replaceable • Single-pole double throw (SPDT) • Output relay: 15A at 110/120 VAC or 10A at

208/230/240 VAC

Sensor Lead Length(in)

Part No.

9 TC4X-1

78 TC4X-2

Description Part No.

1/2 in diameter watertightconduit fitting suitable forNEMA 4 and 6 enclosures.Fits cable 0.17 in to 0.45 indiameter.

41276-04

Accessories

SDC Digital On/Off BenchtopTemperature Controller• Affordable and compact• Compatible with a wide range of heaters and applications • Easy-to-use programmable digital controller, self contained, plug and play design• Temperature control range: 32°F to 999°F

(0°C to 700°C)• Includes thermocouple and power output cords

Part No. Voltage Degrees Cor F

ThermocoupleType

SDC120JF-A 98-132 °F J-Type

SDC120KF-A 98-132 °F K-Type

SDC120JC-A 98-132 °C J-Type

SDC120KC-A 98-132 °C K-Type

SDC240JF-A 184-253 °F J-Type

SDC240KF-A 184-253 °F K-Type

SDC240JC-A 184-253 °C J-Type

SDC240KC-A 184-253 °C K-Type

MAINTAIN PROCESS & TEMPERATURECONTROL

TD Automatic On/OffThermostat Control • Temperature sensitive bimetal disc thermostat • Hermetically sealed black phenolic plastic

housing • Rated: 25 Amps, up to 277 VAC

Class I Division 2(with conduit fitting)

SettingsOpen/Close

°F

SettingsOpen/Close

°CPart No.

Part No. with conduit

fitting

50 /35 2/10 TD101N-050 TD101X-050

60 /45 7/16 TD101N-050 TD101X-050

75 /60 16/24 TD101N-075 TD101X-075

105 /90 32/41 TD101N-105 TD101X-105

200 /185 85/93 TD101N-200 TD101X-200

BH-510 Outdoor Digital Controller • Outdoor and wet-area use • Fast-adaptive-tuning adjusts control

parameters to your process • 4-key touch pad interface • Auto-detect temperature sensor • Programmable in both °F and °C • Adjustable min/max temperatures • Remote control programming option • Wall mount (optional) • 16 amp capacity

Part No. Description

WRW510SR-BH01 Wall mounted outdoor temperature controller

WRZMW110-BH01 IR remote control programming unit

* Plug Option: Add an “E in at the end of the part number for input power leads with ferrule wire crimped termination. i.e. SDC240JC-AE

Page 19: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

YESWE HEATTHAT!

19alliancets.com

630-321-9646

TB110 Hazardous-Area Bulb and Capillary Temperature Controller

• Enclosure rated NEMA 7 & 9, for hazardous areas • 304 stainless steel bulb and capillary, 10 ft long

• Average accuracy of +-5°F (+-3°C) • Single pole, double throw (SPDT) contacts • Rated: 22 amps, up to 480VAC

Class I Division 1 & 2 Group B, C, D Class II Division 1 & 2 Group E, F, G Class III Class I, Zone 1, Group IIB + H2 T6

II 2 G Ex d IIC T6 GbII 2 D Ex tb IIIC T85°C Db IP66T amb = -40°C to 75°C

Ex d IIC T6 GbEx tb IIIC T85°C Db IP66Tamb = -40°C to 75°C

Part No.

Voltage Sensor Type

Input Plug Type

Power Cord Part Number

(Included)

SDXJA 100 - 125 Type-J T/C NEMA 5-15 40911SDXKA 100 - 125 Type-K T/C

SDXRA 100 - 125 PT100-RTD

SDXJC 100 - 240 Type-J T/C NEMA 6-1540911-01SDXKC 100 - 240 Type-K T/C

SDXRC 100 - 240 PT100-RTD

Temperature Range Part No.

0 to 150°F(-17 to 66°C)

TB250N-150

100 to 250°F(38 to 121°C)

TB250N-250 Type Temperature Range

Part No.

Single set-point 25 to 325° F (-4 to 163°C)

TB111N-325

Dual set-point 25 to 325° F(-4 to 163°C)

TB112N-325

SDX Digital Temperature Controller

• Advanced PID control • Plug & play design

• Temperature control range: 0°F to 999°F (0°C to 999°C) • Power cord plugs and sensors to meet individual needs • 5 ft temperature sensor included

NEW!

TB250 All-Purpose Bulb and Capillary Temperature Controller • Enclosure rated NEMA 3R for

outdoor use • Tinned copper bulb and

capillary, 10 ft long • Average accuracy of +-5°F

(+-3°C) • Single pole, double throw

(SPDT) contacts • Rated: 22 amps, up to 277 VAC

MPC2 Multi-Point Digital PID Temperature Controller • Fully configurable for enclosure type,

sensors, number of zones, voltages, alarms, connections, communications, and protection

• Advanced auto-tuning PID control

• 12-step temperature and ramp/ soak programming control

• Actual and set-point programmable as °C or °F

• Temperature control range: 0 to 999°

• Store up to 4 programs for easy repeatability

• 2 levels of password protection

• Large 2-line, 3-color display simultaneously shows PV (actual) and SV (set) temperatures

• Alarm: audible, dry contact (remote), or both

• Outdoor/wet-area version available upon request — IP65

Configure-to-Order Request Your Quote Today!

Other temperature ranges and ambient sensing version available upon request.

Page 20: NEW & FEATURED SOLUTIONS HEAT · 2021. 1. 13. · HB2001 240 NEMA 6-15P 200 Band-Style Crankcase Heaters for HVAC/R Compressors • jug cylinders warm when Protects A/C and heat pump

THOUSANDS OF STANDARD PARTS AVAILABLE AND CUSTOM ENGINEERING CAPABILITIES

312 Park Ave. Unit 145Clarendon Hills, IL 60514

PN: NFSCATALOG-ALLTS RevC


Recommended