Regular software updates for your Vital Sync monitoring and clinical decision support solution or remote surveillance system will let you take advantage of: Improvements Enhanced functionality This reference guide will outline new features in the Vital Sync 2.6 software update, including enhancements to: The user interface Reports Alarm management capabilities Workflow NEW FEATURES. NEW ENHANCEMENTS. Vital Sync 2.6 software update If you have an active Vital Sync software maintenance plan, you can receive software updates at no additional cost. Service and hardware fees may apply. All features and enhancements in this software update may not apply, depending on the type of Vital Sync software product(s) installed at your facility.
Transcript
Page 1: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

1

Regular software updates for your Vital Sync™ monitoring and clinical decision support solution or remote surveillance system will let you take advantage of:

∙Improvements

∙Enhanced functionality

This reference guide will outline new features in the Vital Sync™ 2.6 software update, including enhancements to:

∙The user interface

∙Reports

∙Alarm management capabilities

∙Workflow

NEW FEATURES. NEW ENHANCEMENTS.Vital Sync™ 2.6 software update

If you have an active Vital Sync™ software maintenance plan, you can receive software updates at no additional cost. Service and hardware fees may apply.

All features and enhancements in this software update may not apply, depending on the type of Vital Sync™ software product(s) installed at your facility.

Page 2: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

2

NEW REPORT-VIEWING INTERFACE

Update: An improved user interface for running and viewing reports

Benefit: Easier navigation in report-viewing interface

USERINTERFACE(UI)

Page 3: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

3

PULSE OXIMETER AND CAPNOGRAPH DEVICE DETAIL SCREENTrend and parameter reading now displayed together

Update: Device detail screen for pulse oximeter and capnograph now displays parameter measurement and trend data together rather than requiring user to click on the parameter. Trend panel shows a graph of the most recent 15 minutes of data.

Benefit: Easier access to trend data provides clinicians with improved patient status visualization.

USERINTERFACE(UI)

Page 4: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

4

ACTIVE ALARM FILTERING VISUAL INDICATORNew icon to indicate that device is alarming at bedside

Update: The Tile View and Device Detail screens now have visual indicators (triangle icon) to show that an alarmisbeingdelayedorfilteredby the Vital Sync™ platform.

Benefit: Tells clinicians that the connected device is alarming even when that alarmisbeingdelayedorfilteredon the Vital Sync™ platform.

USERINTERFACE(UI)

Page 5: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

5

SILENCED OR PAUSED ALARM VISUAL INDICATORIcon to indicate that a device has been silenced at bedside

Update: The Tile View and Device Detail screens now have visual indicators (alarm silenced icon) to show that an alarm has been paused or silenced on the bedside device. The visual indicator will only appear for supported device protocols.

Benefit: Tells clinicians that the alarm on the connected bedside device has been paused or silenced.

USERINTERFACE(UI)

Protocol Device Models Supported Device/ Visual Indicator

SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors

Yes

ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors

Yes

Capnostream Capnostream™ 20 & Capnostream™ 35 capnography monitors

Yes

NellcorOridion Nellcor™ N-85 pulse oximetry monitor Yes

MISCF Puritan Bennett™ 840 & 980 ventilators Yes

MISCA Puritan Bennett™ 840 & 980 ventilators Yes

INVOS INVOS™ 5100C cerebral/somatic oximeter No

BISBinary BIS™ monitors (All versions) No

HL7 HL7 Results In Depends on MDI and hospital interface

Page 6: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

6

OXYGENATION SNAPSHOT REPORT UPDATES

REPORTS

Date / Time

Pulse L:40/ H:170

Resp L:8/ H:28

SpO2 L:85/ H:100

Sat-S H:0

SPD EtCO2 H:-

IPI Alarm & Setting Occurrences

9/12/2017 4:00:00 AM

70 12 98 0 15End Reason: Alarm Start / End: ---

9/12/2017 4:23:00 AM

63 12 84 0 15 SpO2 Low Violation (HI)End Reason: EndedAlarm Start / End: 9/13/2017 4:23:00 AM-9/13/2017 4:23:15 AM

9/12/2017 5:00:00 AM

70 11 99 0 15End Reason: Alarm Start / End: ---

9/12/2017 6:00:00 AM

58 15 88 0 15End Reason: Alarm Start / End: ---

9/12/2017 7:00:00 AM

70 12 86 0 15End Reason: Alarm Start / End: ---

9/12/2017 7:13:26 AM

70 6 98 0 15 Resr Rate Low Violation (HI)End Reason: EndedAlarm Start / End: 9/12/2017 7:13:26 AM-9/12/2017 7:14:35 AM

9/12/2017 8:00:00 AM

70 15 99 0 15End Reason: Alarm Start / End: ---

9/12/2017 9:00:00 AM

70 18 89 0 15End Reason: Alarm Start / End: ---

9/12/2017 10:00:00 AM

68 22 88 0 15End Reason: Alarm Start / End: ---

9/12/2017 11:00:00 AM

62 26 97 0 15End Reason: Alarm Start / End: ---

9/12/2017 11:11:13 AM

38 12 95 0 15 Pulse Rate Low Violation (HI)End Reason: EndedAlarm Start / End: 9/12/2017 11:11:13 AM-9/12/2017 11:11:46 AM

9/12/2017 12:00:00 PM

66 12 98 0 15End Reason: Alarm Start / End: ---

Criteria: Alarms: Patient Start & End, Settings: Off, Frequency: Every 1 Hour

Room #: 107

Patient ID: 107From: 9/5/2017 16:57:34 To: 9/12/2017 22:57:32

Hernandez, Mark

Oxygenation Snapshot ReportMedtronic Test Hospital Id : 6135 Gunbarrel Ave, Boulder, CO 80301

Page 1 of 2Sample Report – For Reference OnlyVital Sync™ Informatics Manager

9/12/2017 22:58:16

Improvement:

∙In the report header a high and/or low alarm threshold will be shown if sent from the device

∙If a parameter alarm threshold changes, the report will indicate the new parameter alarm thresholds with a report header

∙When there is a report entry for an alarm the parameter value and time stamp correlates with the alarm

Benefit:Report is easier to understand

Page 7: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

7

ALARM OCCURRENCE PARETO CHARTNew report helps identify common alarms by device or area of care

Update: This report shows the alarms that most frequently occur.

Benefit: Thiscanbeafirststepforclinicians to understand what alarms are most common on a single device or in an area of care. The information can be used to inform the “Alarm Threshold Analysis” report. Dig deeper into aspecificalarmandseehowachange in alarm settings could affectoverallalarmoccurrence.

Note: This report is new for v2.6 customers; not new for v2.5 or earlier.

REPORTS

Page 8: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

8

COMPREHENSIVE OXIMETRY AND CAPNOGRAPHY REPORTUpdates existing report

Update: This is an improved version of the Comprehensive Oximetry Report. It now includes capnography data as well as graphs of important parameters.

Benefit: The report provides information on the overallrespiratoryhealthofaspecificpatientduringauser-specifiedtimeframe.

Note: This report is new for v2.5 customers or earlier; it’s improved for v2.6 customers.

REPORTS

Page 9: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

9

AUTOMATIC PATIENT DISCHARGE FEATURENew feature improves Vital Sync™platformworkflow

WORKFLOW

Update: Provides the ability to automatically discharge a patient who has no associated devices after a designated period of time (determined by hospital). The auto discharge feature default is setto“off.”TheMedtronicprofessionalservices team will need to activate the auto discharge feature.

Benefit: Activating the auto discharge feature can reduce “device missing from network” messages and facilitate improvedworkflow.

Page 10: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

10

AUTO-LINK PATIENT TO CDS APPAutomaticassociationofCDSapptopatientbasedonspecificrules

WORKFLOW

Update: This update enables the Vital Sync™ platform to automatically link a CDS app to a patient by creating specific,customer-definedrules.

Benefit: Improvesworkflowandcomplianceby reducing the number of steps required to monitor patients in accordance with hospital protocols.

Page 11: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

11

DEVICE DISCONNECT INFORMATIONGreater detail on device disconnection

WORKFLOW

Update: New messages appear in the Tile View and Device Detail screens when a device loses communication. This update provides greater detail on why the device disconnected. For example:

“Device Missing from Network” is likely a network issue

“Communication Interrupted” means that thedeviceislikelyturnedofforLantronixboxisturnedoff

Benefit: Provides more information to save users time by knowing which disconnections need attention.

Page 12: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

12

RECONNECT DEVICE TO PATIENT DRAG-AND-DROPFUNCTIONALITYNotifiesclinicalstaffwhenyoucanreconnectdevice

WORKFLOW

Update: If a device loses communication and then regains it, a tile for that device now appears in the Tile View. Users can now reconnect the device in question by dragging and dropping it onto the appropriate patient tile, just as they would do to link a new device.

Benefit: Drag-and-drop functionality is simpler and faster for clinicians.

Page 13: NEW FEATURES. NEW ENHANCEMENTS. · SHIP Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N pulse oximetry monitors Yes ASCII Nellcor™ sensor line, N600, N600x-A, BRPMS & PN1000N

13

DE-ESCALATING ALARMS FOLLOW CONFIGURED RULESFiltering rules apply to de-escalating alarms

ALARMS

Update: Alarms that decrease in severity now follow any delay rules set up for them.

Benefit: Enables de-escalating alarms to follow the same alarmfilteringrulesthatarein place as it de-escalates.