The HyLite High Power LED Omni-Cob Lamp is an energy-efficient replacement for use in a wide variety of new or retrofit applications. It features excellent optics for increased Visibility and Security, with a 360° beam to evenly illuminate the area.
With its Universal Burning Position design and its compact size, the HyLite LED Omni-Cob Lamp is an excellent alternative to standard CFL, MV, HID, or HPS lighting and is ideal for Shoe Box, Area, Street and Roadway, Security, and Post-Top Lighting applications. With a lamp life of up to 60K hours, the HyLite LED Omni-Cob Lamps significantly reduce Relamping costs, thus decreasing Maintenance and Disposal costs.
• ExtremelyEfficient:HighLumenEfficacy:140LpW
• FullyEncapsulated:Shatter-proof,High-Shock&High-VibrationResistant
• Omni-DirectionalwithOptimizedLightingBeamprovidesMaximum 360°LuminancewithHighLumenEfficacy:140LpW
•BrightwhitelightforgreaterVisibilityandSafety.High>80CRI
• EasyInstallation:NoBallastnecessary.DirectRetrofitintoexistingsocket
•InstantStartandRestart:Nowarm-uptimerequired
• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens
• GoodHeatDissipationwithproprietary-designedHeatSink
• CoolOperation:DoesnotaddtoHeatLoadwhileproducingbrilliantlight
• SafeandReliable:IsolatedCircuitDesign.Integral1kVSurgeSuppressor &Protection.IncludesaFree20kAin-lineSurgeProtectionDevicefor added Protection
•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)
• IngressProtection:IP65.CompleteprotectionagainstContact,Dust Infiltration, and Splashed Water
•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalrequirements. Facilitates LEED® points.
•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable
Page:1of2
Universal Burning Positioning
Incandescent HPS/HID CFL HyLite
450W 250W 175W 54W
88% 78% 69% Energy Savings (%)*
* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!
Replacewith
54WHL-OC-54W-E39
3.7" (93mm)
3.7"
(93m
m)
HighPerformanceLEDOmni-CobLamp,54W
HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality of Light with Energy Savings of 88%overIncandescent,78%overHPS/MHLampsand69%overCFL.OMNI-COB TM
LED
*Depending upon the ambient temperature of the installation location
250WMH / HPSEquivalent
FREE!20 kA
In-line Surge Protection Device Included.
Additional Protection for your HyLite
Omni-Cob Lampat no Cost!
Lamp can be oriented in any position - does not affect or diminish the life of the Lamp
Base Down
Base Sideways
BaseUp
NOLEAD, MERCURY, HEAVY METALS
OR TOXIC GASES
98%RECYCLABLE
LED Product Partner
Reliable andLong-Lasting
Warranty
5years
Vibration andShock Resistant
Solid State
Radiation-FreeNo Humming
IRUV
No IR/UV
No Noise
140 LpWLM-79 Tested
High Efficacy
LM-80 TestedISTMT Tested
Reliability
Reduction ofup to 88%
Energy Costs
Up to 60,000 Hours
Low Voltage
Longer Life&
For Enclosed Luminaires
Suitable
360°
IlluminationZero
Interference
No EMi / RFi
4.3”
(109m
m)
10.7
”(2
72m
m)
Ø 3.7” (93mm)
E39/
E40
6.4”
(163m
m)
1.6” (
40m
m)
54WHL-OC-54W-E39
100-277V, AC
Suitable for
Damp Locations Enclosed Fixtures
Page:2of2
Model Delivered Maximum InputLine Base Dimensions&Weight(each) No. Watts Lumens InstallHeight Current Type Diameter Height Weight
HL-OC-54W-E39 54 7560 <26ft.(8m) 195~540mA E39/E40(Mogul) 3.7”(93mm) 10.7”(272mm) 2.2lb.(1kg)
OMNI-COB TM
LEDAs part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.
• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)
• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)
• Efficacy:140LpW • CRI:>80 • BeamAngle:360º • Max.THD(%):<15% • UniversalInputVoltage
• PowerFactor:>0.9 • Protection:IP65 • RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.
• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-70VA-480-240VSpec.Sheetat:https://hyliteledlighting.com/resources/specification-sheets/
• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times
High Performance LED Omni-Cob Lamp, 54W
Photometrics
Intensity: (Unit, cd) C0/180C90/270
135° 150° 165° 180° 165° 150° 135°
45° 30° 15° 0° 15° 30° 45°
60°
120°
105°
90°
75°
60°
120°
105°
90°
75°
100806040
0° 90° 135°90°135°180° 45°45°
80
20
40
100
60
180°
η = 100%
Ideal for high-quality illumination in:
• AreaLighting • ParkingLot • DecorativeLighting
• FloodLighting • AccentLighting • Roadway Lighting
• PendantLights • Driveway&WalkwayLighting • HighBayLighting
• TaskLighting • Historic/VintageFixtures • Stairwells,CorridorsLighting
• JellyJarLights • IndustrialBeacons • PedestrianTunnels
• GlobeFixtures • Explosion-proofFixtures • RailRoadStationPlatforms
• WallPacks • Freezer&ColdStorageLights • Site Lighting
• WallScones • DownLights • Security Lighting
©2012-2019HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 031219
Installation: HyLite LED Lampsaredesignedtoworkoff100Vto277V,AC.Ballast(ifequipped)mustbebypassedor removed from the fixture before installing the lamp. Eliminating the Ballast saves additional costs related to Maintenance, Energy Consumption and Performance. By-passingBallastwillalsoensurethatthereisnoEMi/RFinterference. The installer MUST ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.
Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an ElectricShock,orFire.
Warning - Risk of Fire or Electric Shock
• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will createaHazardousandFatalWorkingEnvironment.
• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.
• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. ThiswillensureLumenMaintenanceandextenditsWorkingLife.WhenproductsareusedinOutdoorFixtures,ensurethespaceisWaterproofandWellVentilated.
• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.
• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.
• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protecttheMetal-threadedbaseoftheLEDLamptopreventWaterand/orMoistureIncursionthatcanleadtoPrematureDegradationoftheLampBaseand eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.
• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.