+ All Categories
Home > Documents > New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top &...

New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top &...

Date post: 01-Sep-2019
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
19
Transcript
Page 1: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air
Page 2: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

New Products 2010

Page 3: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Super Daiseikai V [RAS-xxPKVP-E]

Super Daiseikai V [RAS-xxPKVP-E]

Super Daiseikai III [RAS-BxxSKVP-E]

Super Daiseikai III [RAS-BxxSKVP-E]

Daiseikai [RAS-xxSKVR-E]

Suzumi Plus [RAS-xxSKV2-E]

[RAS-BxxUFV-E]

Hybrid Inverter [RAS-xxSKV-E]

AvAnt [RAS-xx7SKV-E3]

Fix Speed H/P [RAS-xxSKHP-ES]

Fix Speed C/O [RAS-xxSKP-ES]

Fix Speed H/P [RAS-xxSKHP-ES(2)*]

*new OD size 13 + 24

RAS Single - Line Up 2009 2010

C O

P

(Siz

e 1

0)

5,3

5,1

4,2

3,7

3,6

Page 4: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Super Daiseikai III C/O H/P [RAS-BxxSKVP-E]

[RAS-MxxSKCVP-E]

Super Daiseikai III H/P [RAS-BxxSKVP-E]

Hybrid Inverter C/O H/P [RAS-MxxSKCV-E]

[RAS-MxxSKV-E]

Suzumi C/O H/P [RAS-MxxSKCV-E]

[RAS-MxxSKV-E]

Duct C/O H/P [RAS-MxxGDCV-E]

[RAS-MxxGDV-E]

Duct C/O H/P [RAS-MxxGDCV-E]

[RAS-MxxGDV-E]

Compact Cassette C/O H/P [RAS-MxxSMUCV-E]

[RAS-MxxSMUV-E]

Compact Cassette C/O H/P [RAS-MxxSMUCV-E]

[RAS-MxxSMUV-E]

Console H/P [RAS-BxxUFV-E]

RAS Multi - Line Up Indoor

2009 2010

Page 5: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Features:

• Bi-Flow Console

• For Single and Multi application

• Energy class A/A for 10/13k (Single)

• Energy class B/C for 18k (Single)

• COP 4,18/4,27 (size 10k at single application)

• Elegant design

• Floor heating feature with low air-flow

• Quiet operation for more comfort

• Efficient „IAQ“ filter system

• Single operation with Suzumi plus outdoor unit

• Multi operation with all multi outdoor units

Models: RAS-B10UFV-E (2,5/3,2kW) RAS-B13UFV-E (3,5/4,2kW) RAS-B18UFV-E (5,0/5,8kW)

RAS Single/Multi – Console

Page 6: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

3 comfort features: Bi-flow, supreme heating mode and smart user interface

Smart user interface

Floor warming mode

• Pureflow filter • One touch my comfort • Hi-power mode • Eco-logic mode • Comfort sleep • Timer

Bi-flow

Elegant and simple design

RAS Console

Features

Page 7: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Operation Cooling Heating

Air-flow direction

Top & Bottom* Top Top & Bottom Top Bottom

The two outlet at the top and bottom ensure a comfortable air conditioning. You can choose the best air outlet from the following patterns. Especially, the warm air from the bottom is TOSHIBA`s original feature and it flows directly to the floor and spreads along the floor.

Bi-flow

* In case of cooling operation with upper and lower flow, lower flow stops automatically when it reaches the setting temperature.

RAS Console - Features

only

Page 8: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

RAS-B10UFV-E

RAS-B13UFV-E

RAS-B18UFV-E

RAS-10SAV2-E

RAS-13SAV2-E

RAS-18SAV2-E

Single combination

(Suzumi Plus outdoor unit)

RAS-M14GAV-E RAS-M18GAV-E

RAS-4M23SAV-E RAS-3M26GAV-E1 RAS-4M27GAV-E1

RAS-5M34UAV-E

RAS-3M18SAV-E

RAS Console

Combinations

Multi combination

(Inverter multi outdoor unit)

Page 9: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

RAS 5 room multi outdoor unit

Page 10: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Merkmale:

• DC Hybrid Inverter

High Energy Saving Control High Power Factor Control • DC Twin Rotary Compressor Low Noise & Low Vibration Energy Saving (Low Revolution) High Reliability (Low Load to Shaft) • World´s best class heating capacity & COP 4,24 • Wide selection of indoor units (Hi-wall, Console, 4-way cassette and duct)

Model: RAS-5M34UAV-E (10/12kW)

RAS Multi – 5-room outdoor unit

Page 11: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Capacity (kW) Cooling 10,0 (3,7 to 11,0)

Heating 12,0 (3,4 to 14,0)

Power consumption (kW) Cooling 2,923

Heating 2,833

Dimension (mm)

Height 890

Width 900

Depth 320

EER 3,42

COP 4,24

Sound pressure (dB) Cooling 51

Heating 54

Total piping length (m) 80

Height difference (m) 15

Outdoor temperature range (℃) Cooling

Heating

10 to 43

-10 to 22

RAS Multi – 5-room outdoor unit

Specification

RAS-5M34UAV-E

Weight : 75 kg

890

320

900

Page 12: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Super DAISEIKAI

Suzumi

Console

Duct

Compact 4-way

Cassette (60x60)

RAS Multi – 5-room outdoor unit

Highest flexibility

Page 13: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Features:

• High-static pressure duct unit for single use

• Combination with Digital Inverter BIG

• Chassis equal to S-MMS indoor unit

• Industrial No. 1 COP (3,45/3,31)

• External static pressure of up to 196Pa

• 3 steps switchable static pressure

68,6 / 137 / 196 Pa

Models: RAV-SM2242DT-E (20,0/22,4kW) RAV-SM2802DT-E (23,0/27,0kW)

RAV – High Static Duct

Available July 2010 / week 28

Page 14: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Outdoor unit Power supply 3N~380-415V / 50Hz Maximum current 8HP:18A / 10HP:22A

Indoor unit Power supply 1φ220-240V / 50Hz Maximum current 8HP&10HP:15A

RAV – High Static Duct

Electrical Wiring

Page 15: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Parts name Model name Notes Remarks

Drain pump kit TCB-DP32DE Stand-up about 320mm or less

Filter chamber TCB-FCY100DE For long-life filter and high-efficiency

filter

Long-life pre-filter TCB-PF3DE Dust collecting effect : 50% Use with TCB-FCY100DE

High-efficiency filter 65 TCB-UFM3DE Dust collecting effect : 65% Use with TCB-FCY100DE

High-efficiency filter 90 TCB-UFM7DE Dust collecting effect : 90% Use with TCB-FCY100DE

TCC-link adapter TCB-PCNT30TLE2 1:1 model connection interface

RAV – High Static Duct

Indoor accessories

Page 16: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Features:

• Power supply 400V 3phase

• Nr.1 EER/COP

• Additional outdoor unit (14/16kW) for 1:1 with 4-way-cassette, or Twin/Triple- application

• Extended capacities

SP1404: 2,6 - 14 kW cooling cap.

SP1404: 2,4 - 16,5 kW heating cap.

• Extended operation range

cooling: -15 – 46°C

Models: RAV-SP1104AT8-E (10,0/11,2kW) RAV-SP1404AT8-E (12,5/14,0kW) RAV-SP1604AT8-E (14,0/16,0kW)

RAV – Super Digital Inverter Outdoor units 3ph

Available Aug. 2010 /

Week 32

Page 17: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Window Switch & On/Off

TCB-IFCB5-PE

Application control PC Board for RAV and VRF indoor units providing 2 different control functions:

• Window Switch

• Remote On/Off

With using a (local supplied) window switch the unit operation is turned off after opening the window (contact) and not operate again until the window is closed again

After closing:

• Standard function, indoor unit remains off

• Return function, indoor unit will revert to the last setting before the window was opened.

Controller for single indoor unit or a group of up to 8 indoor units (when connected to the master unit of that group)

Page 18: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Preview 2011

Console unit for VRF 2,2 / 2,8 / 3,6 / 4,6 / 5,6 kW For S-MMS, S-HRM, MiNI-SMMS Plan vor January 2011

Console unit for LC 4,0 / 5,0 kW Combination with DI and S-DI Plan vor May 2011

2-Way cassette unit for VRF 2,2 – 16,0 kW New chassis type (290 mm height) Plan vor Q1 2011

Page 19: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air

Thank you for your attention !


Recommended