tcs
SALES BULLETINNew Range of Small Capacity Digital Inverter
w Hi wallw Compact 4-way Cassettew Ceiling Suspendedw Slim Ducted *Available January 2015
are pleased to confirm the introduction of our new small capacity Digital Inverter 4 series ,he units with capacities of 1HP and 1.5HP (2.5kW & 3.6kW) are fully compliant with ErPLot10. The smallerapacity range of Digital Inverter Hi wall, Compact 4-way Cassette, Ceiling Suspended and Slim Ducted
ystems enhance the existing range of Toshiba products and provide solutions for smaller applications.1. Outdoor units
1. Small compact size chassis, light weight for easy installation and transport2. Wide operation range - Heating from -15°C to 24°C3. Compliant with 2015 threshold in EU4. Excellent energy efficiency5. R22 & R407c replacement technology compatible
2. Line-up
Capacity RangeHP (kW)
Model Dimension (mm)H x W x D
Weight(kg)
1.0 (2.5kW) RAV-SM304ATP-E 550 x 780 x 290 33
1.5 (3.6kW) RAV-SM404ATP-E 550 x 780 x 290 39
*Connectable indoor units: Hi wall / Compact 4-way Cassette / Ceiling Suspended / Slim Ducted
3. Factory Production date
October 2014 production;
4. Indoor units
Hi wall Compact 4-way Cassette Ceiling Suspended Slim DuctedRAV-SM307KRTP-E RAV-SM304MUT-E RAV-SM407CTP-E RAV-SM304SDT-ERAV-SM407KRTP-E RAV-SM404MUT-E RAV-SM404SDT-E
Capacity(HP)
Indoor model nameDime
H
Hi wall
1.0 RAV-SM307KRTP-E275 x
1.5 RAV-SM407KRTP-E
Compact 4-way Cassette
1.0 RAV-SM304MUT-E268 x
1.5 RAV-SM404MUT-E
Ceiling Suspended
1.5 RAV-SM407CTP-E 235 x
Slim Ducted
1.0 RAV-SM304SDT-E210 x
1.5 RAV-SM404SDT-E
5. Performance Data
Model Rated Capacity (kW)
HP Indoor unit Outdoor unit Cooling Heating SEE
1.0 RAV-SM307KRTP-E RAV-SM304ATP-E 2.5 3.4 5.9
1.0 RAV-SM304MUT-E RAV-SM304ATP-E 2.5 3.4 5.5
1.0 RAV-SM304SDT-E RAV-SM304ATP-E 2.5 3.4 6.1
1.5 RAV-SM407KRTP-E RAV-SM404ATP-E 3.6 4.0 5.4
1.5 RAV-SM404MUT-E RAV-SM404ATP-E 3.6 4.0 5.3
1.5 RAV-SM404SDT-E RAV-SM404ATP-E 3.6 4.0 5.5
1.5 RAV-SM407CTP-E RAV-SM404ATP-E 3.6 4.0 5.9
For further information please contact our customer support teamyour supplier of products or email any [email protected]
nsion (mm)x W x D
Weight(kg)
790 x 225 10
575 x 575 16
950 x 690 23
845 x 645 22
Specifications
REnergyLabel
Pdesign C SCOP(average)
EnergyLabel
Pdesign H(average)
0 A+ 2.5 4.00 A+ 3.0
3 A 2.5 4.27 A+ 3.1
0 A++ 2.5 4.48 A+ 2.9
0 A 3.6 4.12 A+ 3.6
5 A 3.6 4.27 A+ 3.7
5 A 3.6 3.88 A 3.7
6 A+ 3.6 4.98 A++ 4.0
on 0870 843 0333, your local representative,s to: -
Hi wall
Specification
INDOOR MODEL RAV- SM307KRTP-E SM407KRTP-E
OUTDOOR MODEL RAV- SM304ATP-E SM404ATP-E
Power Supply 1 phase 220-240 V 50Hz
Rated Cooling Capacity*1
(kW) 2.50 3.60
Power Consumption (kW) 0.61 1.13
EER 4.10 3.19
SEER 5.90 5.40
Energy Rating A+ A
Rated Heating Capacity*1
(kW) 3.40 4.00
Power Consumption (kW) 0.85 1.12
COP 4.00 3.57
SCOP 4.00 4.12
Energy Rating A+ A+
Indoor Unit Height / Width / Depth (mm) 275 x 790 x 217
Indoor Total Weight (kg) 10
Cooling
FCU Standard Air Flow (H/M/L) (m3/h) 516/414/300
Sound Pressure Level (H/M/L) dB(A) 40 / 34 / 29 41 / 36 / 30
Sound Power Level (H/M/L) dB(A) 55 / 49 / 44 56 / 51 / 45
Heating
FCU Standard Air Flow (H/M/L) (m3/h) 570 / 462 / 360 690 / 522 / 350
Sound Pressure Level (H/M/L) dB(A) 41 / 37 / 31 45 / 40 / 32
Sound Power Level (H/M/L) dB(A) 56 / 52 / 46 60 / 55 / 47
Outdoor Unit Height / Width / Depth (mm) 550 x 780 x 290
Outdoor Total Weight (kg) 33 39
Outdoor Sound Power Level Cooling / Heating dB(A) 61 / 62 64 / 65
Refrigerant Type R410A
Max. Total Piping Length / Chargeless to (m) 20 / 15
Refrigerant Additional Charge Main Liquid Side (g/m) 20
Max. Height Difference (m) 10
Flare ConnectionsGas Side (mm - ") 9.52 - 3/8 12.7 - 1/2
Liquid Side (mm - ") 6.35 - ¼
Operating RangeCooling (°C) (-15) ~ 46
Heating (°C) (-15) ~ 24
*1. Rated are based on the following conditionCooling: Indoor air temperature 27 °C DB / 19°C WB, Outdoor air temperature 35°C DBHeating: Indoor air temperature 20 °C DB Outdoor air temperature 7°C DB / 6°C WB
Compact 4-way Cassette
Specification
INDOOR MODEL RAV- SM304MUT-E SM404MUT-E
OUTDOOR MODEL RAV- SM304ATP-E SM404ATP-E
Power Supply 1 phase 220-240 V 50Hz
Rated Cooling Capacity*1
(kW) 2.50 3.60
Power Consumption (kW) 0.59 0.90
EER 4.24 4.00
SEER 5.53 5.35
Energy Rating A A
Rated Heating Capacity*1
(kW) 3.40 4.00
Power Consumption (kW) 0.76 0.95
COP 4.47 4.21
SCOP 4.27 4.27
Energy Rating A+ A+
Indoor Unit Height / Width / Depth (mm) 268 x 575 x 575
Indoor Total Weight (kg) 16
Cooling
FCU Standard Air Flow (H/M/L) (m3/h) 640 / 520 / 440 660 / 552 / 468
Sound Pressure Level (H/M/L) dB(A) 40 / 36 / 31 40 / 36 / 31
Sound Power Level (H/M/L) dB(A) 55 / 51 / 46 55 / 51 / 46
Heating
FCU Standard Air Flow (H/M/L) (m3/h) 640 / 520 / 440 660 / 552 / 468
Sound Pressure Level (H/M/L) dB(A) 40 / 36 / 31 40 / 36 / 31
Sound Power Level (H/M/L) dB(A) 55 / 51 / 46 55 / 51 / 46
Outdoor Unit Height / Width / Depth (mm) 550 x 780 x 290
Outdoor Total Weight (kg) 33 39
Outdoor Sound Power Level Cooling / Heating dB(A) 61 / 62 64 / 65
Refrigerant Type R410A
Max. Total Piping Length / Chargeless to (m) 20 / 15
Refrigerant Additional Charge Main Liquid Side (g/m) 20
Max. Height Difference (m) 10
Flare ConnectionsGas Side (mm - ") 9.52 - 3/8 12.7 - 1/2
Liquid Side (mm - ") 6.35 - ¼
Operating RangeCooling (°C) (-15) ~ 46
Heating (°C) (-15) ~ 24
*1. Rated are based on the following conditionCooling: Indoor air temperature 27 °C DB / 19°C WB, Outdoor air temperature 35°C DBHeating: Indoor air temperature 20 °C DB Outdoor air temperature 7°C DB / 6°C WB
Ceiling Suspended
Specification
INDOOR MODEL RAV- RAV-SM407CTP-E
OUTDOOR MODEL RAV- RAV-SM404ATP-E
Power Supply 1 phase 220-240 V 50Hz
Rated Cooling Capacity*1
(kW) 3.60
Power Consumption (kW) 0.83
EER 4.34
SEER 5.96
Energy Rating A+
Rated Heating Capacity*1
(kW) 4.00
Power Consumption (kW) 0.78
COP 5.13
SCOP 4.98
Energy Rating A++
Indoor Unit Height / Width / Depth (mm) 235 x 950 x 690
Indoor Total Weight (kg) 23
Cooling
FCU Standard Air Flow (H/M/L) (m3/h) 900 / 720 / 540
Sound Pressure Level (H/M/L) dB(A) 37 / 35 / 28
Sound Power Level (H/M/L) dB(A) 52 / 50 / 43
Heating
FCU Standard Air Flow (H/M/L) (m3/h) 900 / 720 / 540
Sound Pressure Level (H/M/L) dB(A) 37 / 35 / 28
Sound Power Level (H/M/L) dB(A) 52 / 50 / 43
Outdoor Unit Height / Width / Depth (mm) 550 x 780 x 290
Outdoor Total Weight (kg) 39
Outdoor Sound Power Level Cooling / Heating dB(A) 64 / 65
Refrigerant Type R410a
Max. Total Piping Length / Chargeless to (m) 20 / 15
Refrigerant Additional Charge Main Liquid Side (g/m) 20
Max. Height Difference (m) 10
Flare ConnectionsGas Side (mm - ") 12.7 - 1/2
Liquid Side (mm - ") 6.35 - 1/4
Operating RangeCooling (°C) (-15) ~ 46
Heating (°C) (-15) ~ 24
*1. Rated are based on the following conditionCooling: Indoor air temperature 27 °C DB / 19°C WB, Outdoor air temperature 35°C DBHeating: Indoor air temperature 20 °C DB Outdoor air temperature 7°C DB / 6°C WB
Slim Ducted
Specification
INDOOR MODEL RAV- SM304SDT-E SM404SDT-E
OUTDOOR MODEL RAV- SM304ATP-E SM404ATP-E
Power Supply 1 phase 220-240 V 50Hz
Rated Cooling Capacity*1
(kW) 2.50 3.60
Power Consumption (kW) 0.56 0.93
EER 4.46 3.87
SEER 6.10 5.55
Energy Rating A+ A
Rated Heating Capacity*1
(kW) 3.40 4.00
Power Consumption (kW) 0.86 0.97
COP 3.95 4.12
SCOP 4.48 3.88
Energy Rating A+ A
Indoor Unit Height / Width / Depth (mm) 210 x 845 x 645
Indoor Total Weight (kg) 22
Cooling
FCU Standard Air Flow (H/M/L) (m3/h) 690 / 560 / 480 690 / 600 / 522
Sound Pressure Level (H/M/L) dB(A) 39 / 36 / 33 39 / 36 / 33
Sound Power Level (H/M/L) dB(A) 54 / 51 / 48 54 / 51 / 48
Heating
FCU Standard Air Flow (H/M/L) (m3/h) 660 / 560 / 480 690 / 600 / 522
Sound Pressure Level (H/M/L) dB(A) 39 / 36 / 33 39 / 36 / 33
Sound Power Level (H/M/L) dB(A) 54 / 51 / 48 54 / 51 / 48
Outdoor Unit Height / Width / Depth (mm) 550 x 780 x 290
Outdoor Total Weight (kg) 33 39
Outdoor Sound Power Level Cooling / Heating dB(A) 61 / 62 64 / 65
Refrigerant Type R410A
Max. Total Piping Length / Chargeless to (m) 20 / 15
Refrigerant Additional Charge Main Liquid Side (g/m) 20
Max. Height Difference (m) 10
Flare ConnectionsGas Side (mm - ") 9.52 - 3/8 12.7 - 1/2
Liquid Side (mm - ") 6.35 - ¼
Operating RangeCooling (°C) (-15) ~ 46
Heating (°C) (-15) ~ 24
*1. Rated are based on the following conditionCooling: Indoor air temperature 27 °C DB / 19°C WB, Outdoor air temperature 35°C DBHeating: Indoor air temperature 20 °C DB Outdoor air temperature 7°C DB / 6°C WB