22
IS THERE AN ELEPHANT IN OUR CLOSET? Images of recent explosions caused by propane tank ruptures THERE IS AN ELEPHANT IN OUR CLOSET!
Transcript
Page 1: Nfpa 96 task force b5520.1.pptx

IS THERE AN ELEPHANT IN OUR CLOSET?

Images of recent explosions caused by propane tank

ruptures

THERE IS AN ELEPHANT IN OUR CLOSET!

Page 2: Nfpa 96 task force b5520.1.pptx

Propane (LPG) is extremely volatile

Page 3: Nfpa 96 task force b5520.1.pptx

Propane is more dense than air and forms an explosive pool

Page 4: Nfpa 96 task force b5520.1.pptx

This explosion in

Michigan involved a

forklift hitting an

LPGCylinder.

Page 5: Nfpa 96 task force b5520.1.pptx

This is a controlled LPG explosion of an external ignition source ignited

venting Propane.

Page 6: Nfpa 96 task force b5520.1.pptx

ALL OF THESE EXPLOSIONS INVOLVED PROPANE

Page 7: Nfpa 96 task force b5520.1.pptx

The fastest growing restaurant segment is Mobile Kitchens • Mobile Kitchens use propane fuel source.• Mobile Kitchens populate all major American Cities.

Mobile Kitchens represent a major target of opportunity for our enemies.

Page 8: Nfpa 96 task force b5520.1.pptx

THERE IS A MUCH SAFER ALTERNATIVE FOR THE MOBILE

KITCHEN INDUSTRY!

Page 9: Nfpa 96 task force b5520.1.pptx

CNG-ONE GUARDIAN B5520HAS BEEN APPROVED BY F.D.N.Y.

FOR NEW YORK CITY

Page 10: Nfpa 96 task force b5520.1.pptx

CLEAN, SAFE CNG-ONE GUARDIAN B5520 FUEL SYSTEMS

• CNG IS LIGHTER THAN AIR AND VENTS INTO THE ATMOSPHERE IF RELEASED.

• CNG-One Guardian B5520 features numerous safety devises

• The Guardian B5520 is mounted on solid steel plate "inside" the food cart

• The Guardian uses a bullet resistant, very robust Type 2 CNG PRESSURE VESSELS.

Page 11: Nfpa 96 task force b5520.1.pptx

And a new, robust, CNG Fuel System

Developed by CNG-One, LLC

Page 12: Nfpa 96 task force b5520.1.pptx

Built on Solid ¼ inch Carbon Steel Foundation

Page 13: Nfpa 96 task force b5520.1.pptx

Mounted with DOT, 8G Compliant Grade 8 Fasteners

Page 14: Nfpa 96 task force b5520.1.pptx

Fueled by a Bullet Resistant, Type 2

CNG Storage Cylinder

Page 15: Nfpa 96 task force b5520.1.pptx

FDNY Approved for the Streets of

New York

Page 16: Nfpa 96 task force b5520.1.pptx

Redundant safeguards

Fueling Receptacle

Pressure Relief Safety

Valve

Page 17: Nfpa 96 task force b5520.1.pptx

CNG Routed through Coalescent Filter

Filter conditions the fuel prior to

Regulator

Page 18: Nfpa 96 task force b5520.1.pptx

High Pressure Regulator reduces pressure from 3600 psi

to less than 100 psi

Page 19: Nfpa 96 task force b5520.1.pptx

Conditioned CNG is routed through

an Attenuator buffer system

Attenuator System

Page 20: Nfpa 96 task force b5520.1.pptx

Attenuator Terminates at

Domestic Low Pressure Regulator

¼ Turn Ball Valve Shut off

Low pressure Regulator

Page 21: Nfpa 96 task force b5520.1.pptx

Domestic Regulator further reduces

pressure to (+/-) 1 psi

Low pressure Regulator

Domestic Connection

Page 22: Nfpa 96 task force b5520.1.pptx

Your CNG-One Fuel System is now ready for connections to operate all cart appliances

...and provide clean, sustainable fuel to operate the generator.

Food Truck Manufacturers should ask us about our Single-Source CNG Fuel Systems to operate

Vehicle, Generator and appliances.