+ All Categories
Home > Documents > Niky and Niky S UpS SINGLE-PHASE from 600 to 3000 VA€¦ · Niky S UPS Line Interactive -...

Niky and Niky S UpS SINGLE-PHASE from 600 to 3000 VA€¦ · Niky S UPS Line Interactive -...

Date post: 19-Aug-2020
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
6
THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES NIKY and NIKY S UPS from 600 to 3000 VA UPS SINGLE-PHASE
Transcript
Page 1: Niky and Niky S UpS SINGLE-PHASE from 600 to 3000 VA€¦ · Niky S UPS Line Interactive - Single-phase VI-SS 3 100 06 1000-1500-2000 VA 3000 VA IN OUT USB RS232 IN OUT USB RS232

THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Niky and Niky S UpS

from 600 to 3000 VA

UPSSINGLE-PHASE

Page 2: Niky and Niky S UpS SINGLE-PHASE from 600 to 3000 VA€¦ · Niky S UPS Line Interactive - Single-phase VI-SS 3 100 06 1000-1500-2000 VA 3000 VA IN OUT USB RS232 IN OUT USB RS232

Niky line interactive

Ideal protectionfor all applications

such asSmall-Office

Home-Office. They represent the offer with the best quality/price ratio for the safety of data within the office, your own business and the home PC.Equipped with CPU control, integrated AVR and interfacefor intelligent communication, ensuring optimal protection management.

Advanced management of battery dischargeAVR stabiliser Integrated self-diagnostic functionCold start-up functionIntelligent microprocessor controlRS232 or USB interface for managing the UPSMODEM/LAN telephone protection

Page 3: Niky and Niky S UpS SINGLE-PHASE from 600 to 3000 VA€¦ · Niky S UPS Line Interactive - Single-phase VI-SS 3 100 06 1000-1500-2000 VA 3000 VA IN OUT USB RS232 IN OUT USB RS232

®

WWW.UPS.LEGRAND.COM

Niky S line interactive

Sinusoidal outputControl using intelligent microprocessorMODEM/LAN telephone protectionRS-232 and USB interface for managing the UPSCold start-up functionProtection from voltage peaksSelf-test function for the Uninterruptable power unitIntelligent battery managementProtection from overload and short-circuitExcellent voltage adjustment

Page 4: Niky and Niky S UpS SINGLE-PHASE from 600 to 3000 VA€¦ · Niky S UPS Line Interactive - Single-phase VI-SS 3 100 06 1000-1500-2000 VA 3000 VA IN OUT USB RS232 IN OUT USB RS232

3 100 133 100 02

NikyUPS Line Interactive - Single-phase VI

600-800 VA 1000-1500 VA

SITE WIRING

FAULT RS232USB

IN OUT

SITE WIRING

FAULT RS232USB

IN OUT

SITE WIRING FAULT

AC INPUT AC OUTPUT

SITE WIRING FAULT

AC INPUT AC OUTPUT

IN OUT

NOTE: back up time values, expressed in minutes, are measured during optimal operating conditions.

Pack. Item UPS with Standard German oUtPUt SocketSNomINAL

PowEr VA

PowEr: ActIVE

w

BAck UP tImE (mIN.)

No. of SockEtS

IEc

No. of SockEtS StANDArD

GErmAN

PortS for

commUNIcAtIoN

3 100 00 600 300 5÷30 - 1 USB3 100 01 800 400 5÷30 - 1 USB

UPS with Standard German oUtPUt SocketS + iec Socket

NomINAL PowEr

VA

PowEr: ActIVE

w

BAck UP tImE (mIN.)

No. of SockEtS

IEc

No. of SockEtS StANDArD

GErmAN

PortS for

commUNIcAtIoN

3 100 09 600 300 5÷30 1 1 USB3 100 10 800 400 5÷30 1 1 USB3 100 13 1000 600 5÷30 2 2 RS2323 100 14 1500 900 5÷30 2 2 RS232

UPS with mUltiPle iec oUtPUt SocketSNomINAL

PowEr VA

PowEr: ActIVE

w

BAck UP tImE (mIN.)

No. of SockEtS

IEc

No. of SockEtS StANDArD

GErmAN

PortS for

commUNIcAtIoN

3 100 02 600 300 5÷30 3 - USB3 100 03 800 400 5÷30 3 - USB3 100 04 1000 600 5÷30 6 - USB3 100 05 1500 900 5÷30 6 - USB

item3 100 003 100 023 100 09

3 100 013 100 033 100 10

3 100 013 100 043 100 13

3 100 053 100 14

General Features

Nominal power (VA) 600 800 1000 1500

Active power (W) 300 400 600 900

Technology Line-interactive VI

Waveform Pseudo-Sinusoidal

input

Input voltage 230 V

Input frequency 50-60 Hz

Input Voltage Range 160V-290V

Output

Output voltage 230V ± 10%

Output frequency (nominal) 50/60 Hz +/-1%

THD Output voltage ‹ 3% with linear load

Batteries

Number of batteries 1 1 2 2

Battery series Type/Voltage 12V, 7Ah 12V, 9Ah 12V, 7Ah 12V, 9Ah

Configuration and Management

Display and SignalsOne push button and 2 LED to monitor UPS

status in real-time.

One push button and 4 LED to monitor UPS

status in real-time

Telephone protection RJ11/RJ45

Remote Management available

Mechanical Features

Dimensions H x W x D (mm) 171x95x349 239x147x354

Net Weight (kg) 7 7,5 13 16

Environmental Conditions

Operating temperature (°C) 0 ÷ 40°C

Relative humidity (%) 0÷95 % non-condensing

Noise level at 1 m (dBA) ‹40

Certifications

Standards EN62040-1, EN62040-2, EN62040-3

Warranty

Standard Warranty 2 years

Page 5: Niky and Niky S UpS SINGLE-PHASE from 600 to 3000 VA€¦ · Niky S UPS Line Interactive - Single-phase VI-SS 3 100 06 1000-1500-2000 VA 3000 VA IN OUT USB RS232 IN OUT USB RS232

Pack. Item UPSNomINAL

PowEr VA

PowEr: ActIVE

w

BAck UP tImE (mIN.)

No. of SockEtS

IEc

PortS for

commUNIcAtIoN

3 100 06 1000 600 9 6 USB-RS2323 100 20 1500 900 8 6 USB-RS232 3 100 07 2000 1200 9 6 USB-RS2323 100 08 3000 1800 8 6 USB-RS232

WWW.UPS.LEGRAND.COM

Niky SUPS Line Interactive - Single-phase VI-SS

3 100 06

1000-1500-2000 VA 3000 VA

IN OUT USB RS232 IN OUT USB RS232

NOTE: back up time values, expressed in minutes, are measured during optimal operating conditions.

item 3 100 06 3 100 20 3 100 07 3 100 08

General Features

Nominal power (VA) 1000 1500 2000 3000

Active power (W) 600 900 1200 1800

Technology Line-interactive VI-SS

Waveform Sinusoidal

input

Input voltage 230 V ± 12% on network ± 5% on battery

Input frequency 50-60 Hz

Input Voltage Range 160V-290V

Output

Output voltage 230V ± 10%

Output frequency (nominal) 50/60 Hz +/-0.2%

THD Output voltage ‹ 3% with linear load

Batteries

Number of batteries 2 2 4 4

Type/Voltage battery series 12V, 7Ah 12V, 9Ah 12V, 7Ah 12V, 9Ah

Configuration and Management

Display and Signals Three buttons and three LEDs to monitor the status of the UPS in real time

Telephone protection RJ11/RJ45

Remote Management available

Mechanical Features

Dimensions H x W x D (mm) 242x169x361 242x169x464

Net Weight (kg) 13 15 22 24

Environmental Conditions

Operating temperature (°C) 0 ÷ 40°C

Relative humidity (%) 0÷95 % non-condensing

Noise level at 1 m (dBA) ‹40

Certifications

Standards EN62040-1, EN62040-2, EN62040-3

Warranty

Standard Warranty 2 years