Technical specification
FLUXUS® F502BT
TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01 1
Non-invasive ultrasonic thermal energy and volume flowmeter
Stationary ultrasonic clamp-on system for heat quantity and flow measurement of water
Features
• Single channel thermal energy and volume flow mea-surement device with two temperature inputs (Pt100 clamp-on or insertion temperature probes available)
• Complete integrated thermal energy/BTU metering system
• Very high temperature accuracy, temperature probes are matched to 0.1 °C in temperature difference
• Available with a 4...20mA current output and offering full Modbus RTU or BACnet MS/TP functionality
• Very high turndown ratio > 1000 : 1
• Measures very low flow velocities down to 0.01 m/s - very important for measuring off peak flow rates (e.g. during night)
• Permanent coupling pads - no grease, no maintenance required
Low Flow Sensitivity
• Thermal energy supply systems are designed to deliver adequate cooling or heating during peak climate condi-tions. As a result, most applications run at low and sometimes very low flow velocities.
• One of the biggest problems with accurate thermal en-ergy (BTU) metering is that most meters cannot detect such flow velocities and, consequently, often fail to monitor low energy flows. The FLUXUS F502BTU me-ter is specially designed to accurately meter flow veloc-ities in this low range.
Temperature Accuracy
• In applications with small temperature differentials such as chilled water applications, the temperature measurement accuracy is critically important.
• FLEXIM’s temperature measurement system provides a differential measurement uncertainty of better than 0.1 °C.
FLUXUS F502BTU
Applications
• HVAC
• District energy
• Chilled and hot water plants in
- College campuses
- Corporate complexes
- Government complexes
- Commercial buildings
- Malls
- Hospitals
- Sports arenas
- etc.
• Industrial cooling and heating
• Geothermal installations
• Industrial processes
FLUXUS BTU 500
FLUXUS® F502BT Technical specification
Flow transmitter
Technical data
FLUXUS F502BT-NNF502BT-F2
design field device with 1 measuring channelapplication BTU/energy metermeasurementmeasurement principle transit time difference correlation principleflow velocity 0.01...25 m/srepeatability 0.25 % of reading ±0.01 m/sfluid water and thermal fluids (glycol, BP Transcal LT, BP Transcal N, R22 Freon, R134 Freon, ammonia, Shell
Termina B, glycol/H2O 20 %, glycol/H2O 30 %, glycol/H2O 40 %, glycol/H2O 50 %, Mobiltherm 594, Mobil-therm 603, R407C, R410A)
accuracy1
- measuring system ±2 % of reading ±0.01 m/sflow transmitterpower supply 100...230 V/50...60 Hz or
20...32 V DC or11...16 V DC
power consumption < 10 W
number of flow measuring channels
1
damping 0...100 s, adjustablemeasuring cycle (1 channel) 10 Hzresponse time 1 shousing material aluminum, powder coateddegree of protection accord-ing to IEC/EN 60529
IP66
dimensions see dimensional drawingweight 1.9 kgfixation wall mounting, optional: 2 " pipe mountingambient temperature -10...+60 °C display 2 x 16 characters, dot matrix, backlightmenu language English, German, French, Dutch, Spanishexplosion protection (optional)
FM
transmitter F502BT-F2marking Cl. I, II, III/Div. 2/
GP. A, B, C, D, E, F, G/
Cl. I/Div. 2/ GP. A, B, C, D/
T4 Ta = 60 °Cmeasuring functionsphysical quantities volumetric flow rate, mass flow rate, flow velocity, heat flowtotalizer volume, mass, heat quantitydata logger (optional)loggable values all physical quantities and totalized valuescapacity > 100 000 measured valuescommunicationinterface optional: RS485 (sender) or Modbus RTU or BACnet MS/TP or M-Bus (nonEx)outputs
The outputs are galvanically isolated from the transmitter.current output
number 1, optional: 2range 0/4...20 mAaccuracy 0.1 % of reading ±15 μAactive output Rext < 500 Ω
binary outputnumber 1, optional: 2optorelay 28 V/100 mAbinary output as alarm output- functions limit, change of flow direction or errorbinary output as pulse output mainly for totalizing- pulse value 0.01...1000 units- pulse width 80...1000 ms
1 for reference conditions and v > 0.25 m/s
2 TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01
Technical specification FLUXUS® F502BT
Dimensions
2 " pipe mounting kit (optional)
inputsThe inputs are galvanically isolated from the transmitter.temperature input
number 2type Pt100connection 4-wirerange -150...+560 °Cresolution 0.01 Kaccuracy ±0.01 % of reading ±0.03 K
FLUXUS F502
in mm
FLUXUS F502BT-NNF502BT-F2
thread: 4x M20 x 1.5cable gland: max. 4x M20
103
140
71
Ø 4.5
Ø 8.4
10
205
220
fixing holes for wall mounting
TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01 3
4 TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01
FLUXUS® F502BT Technical specification
Terminal assignment
FLUXUS F502BT
power supplyterminal connection (AC) connection (DC)PE earth earthN(-) neutral -L(+) phase +
transducersextension cable, transducer cablemeasuring channel A
terminal connection
AV transducer , signal
AVS transducer , internal shield
ARS transducer , internal shield
AR transducer , signal
cable gland external shield
outputsterminal connection1(-), 2(+) binary output3(-), 4(+) binary output5(-), 6(+) current output I17(-), 8(+) current output I29 (-), 10 (+), 11 (shield) communication interface
inputstemperature probe
terminal direct connection connection with extension cable
TF1, TX1 red redTF2, TX2 red/blue greyTF3, TX3 white/blue blueTF4, TX4 white white
AV AVS
AGN
ARS
AR
Technical specification FLUXUS® F502BT
Transducers
Transducer selection
Technical data
transducer frequency
M 50 100 400
P 25 50 200
Q 10 25 150
5 10 50 100 500 1000 5000inner pipe diameter [mm]
recommended possible
technical type CDM2LZ7 CDP2LZ7 CDQ2LZ7transducer frequency MHz 1 2 4
inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. mm 400 200 150pipe wall thicknessmin. mm 2 1 0.6materialhousing PEEK with stainless steel
cap 316Ti (1.4571)PEEK with stainless steel cap 316Ti (1.4571)
PEEK with stainless steel cap 316Ti (1.4571)
contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP67 IP67 IP67
transducer cabletype 2606 2606 2606length m 15 15 15dimensionslength l mm 59 59 36width b mm 28 28 18height h mm 31 31 21dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +100 +100 +100remark
hb
l
hb
l
TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01 5
FLUXUS® F502BT Technical specification
technical type CLM2N53 CLP2N53 CLQ2N53transducer frequency MHz 1 2 4inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 2000 200 150max. extended mm 3400 600 400materialhousing PEEK with stainless steel
cap 316L (1.4404)PEEK with stainless steel cap 316L (1.4404)
PEEK with stainless steel cap 316L (1.4404)
contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP67 IP67 IP67
transducer cabletype 1699 1699 1699length m 9 9 9dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
weight (without cable) kg 0.066 kg 0.066 kg 0.016 kgambient temperaturemin. °C -40 -40 -40max. °C +130 +130 +130temperature compen-sation
x x x
explosion protection
FM
explosion protection temperaturemin. °C -55 -55 -55max. °C +190 +190 +190marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860type of protection non incendive non incendive non incendive
remark for F502BT-F2
l
hb
l
hb
hb
l
6 TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01
Technical specification FLUXUS® F502BT
Transducer mounting fixture
Coupling materials for transducers
Technical data
Variofix L
material: stainless steel 316 (1.4571), 316L (1.4404), 17-7PH (1.4568)
inner length:VLM: 234 mmVLQ: 176 mm
dimensions:VLM: 309 x 57 x 63 mmVLQ: 247 x 43 x 47 mm
tension straps, clasps and transducer shoes
material: stainless steel 304 (1.4301), 303 (1.4305)
tension strap length: 10 m
type ambient temperature material°C
coupling compound type N -30...+130 mineral grease paste
coupling foil type VT -10...+200 fluoroelastomer
TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01 7
8 TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01
FLUXUS® F502BT Technical specification
Connection systems
x - transducer cable length
l - max. length of extension cable
Transducer cable
Technical data
connection with extension cable direct connection transducerstechnical type
*****53
****LZ7
transducer cable extension cabletype 2606 1699 2552 2615standard length x 15 9 - -max. length l m - - 90ambient temperature °C -40...+100 -55...+200 -25...+80 -40...+70properties halogen free
fire propagation test according to IEC 60332-1
combustion test accord-ing toIEC 60754-2
cable jacketmaterial PUR PTFE TPV PURouter diameter mm 5 2.9 12 12thickness mm 0.3 2colour grey brown black blackshield x x x xsheathmaterial - stainless steel 316Ti
(1.4571)- -
outer diameter mm - 8 - -
tran
smitt
er
x
l
JB04
tran
smitt
er
x
tran
smitt
er
x
l
JB05
tran
smitt
er
x
Technical specification FLUXUS® F502BT
Junction box
Technical data
Dimensions
2 " pipe mounting kit (optional)
technical type JB04 JB05dimensions see dimensional drawing see dimensional drawingweight kg 1.2 kg 1.2 kgfixation wall mounting, optional: 2 " pipe mounting wall mounting, optional: 2 " pipe mountingmaterialhousing stainless steel 316L (1.4404) stainless steel 316L (1.4404)gasket silicone siliconedegree of protection according to IEC/EN 60529
IP66, NEMA 4X IP67
ambient temperaturemin. °C -40 -40max. °C +60 +80explosion protection
FM
marking NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
T6 Ta = -40...+60 °C
-
in mm
174
1192
wall mounting holder
70163.5
156
Ø 9
thread: 3x M20 x 1.5cable gland: max. 2x M20
TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01 9
FLUXUS® F502BT Technical specification
Terminal assignment
JB04
JB05
transducers
terminal connectionXV transducer , SMB connectorXR transducer , SMB connectorcable gland external shield
extension cable
terminal strip KL2terminal connection
TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield
shield terminal
equipotential bonding terminal(at wall mounting holder)
transducers
terminal strip KL1terminal connection
TV transducer , signalTVS transducer , internal shieldTRS transducer , internal shieldTR transducer , signalcable gland external shield
extension cable
terminal strip KL2terminal connection
TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield
shield terminal
10 TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01
Technical specification FLUXUS® F502BT
Clamp-on temperature probe (optional)
Technical data
Connection
Temperature probe
Cable
technical type PT12Ntype Pt100connection 4-wiremeasuring range °C -30...+250
accuracy T ±(0.15 °C + 2 . 10-3 . |T [°C]|)class A
accuracy ∆T(2x Pt matched accor-ding to EN 1434-1)
≤ 0.1 K (3 K < ∆T < 6 K), more corresponding to EN 1434-1
response time s 50housing aluminumdegree of protection according to IEC/EN 60529
IP66
weight kg 0.25fixation clamp-onaccessoriesthermal conductivity paste 200 °C
x
thermal conductivity foil 250 °C
x
dimensionslength l mm 15width b mm 15height h mm 20
connection with extension cable direct connection technical type
PT12N
cable of temperature probe extension cabletype 4 x 0.25 mm² black LIYCY 8 x 0.14 mm² greystandard length m 3 5/10/25max. length m - 200cable jacket PTFE PVC
extension cable
junction box
l
h
red/blue red white/blue white
TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01 11
FLUXUS® F502BT Technical specification
Junction boxtechnical type JBT3dimensions see dimensional drawingfixation wall mounting
optional: 2 " pipe mountingmaterialhousing stainless steel 316L (1.4404)gasket siliconedegree of protection according to IEC/EN 60529
IP67
cable gland max. 2x M12ambient temperaturemin. °C -40max. °C +80
Terminal assignment
JBT3
temperature probe
terminal strip KL1terminal connection
1 red2 red/blue3 white4 white/blue
extension cable
terminal strip KL2terminal connection
1 red2 grey3 white4 blue
shield terminal
12 TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01
14 TSFLUXUS_F502BTV2-1EN_Leu, 2016-08-01
FLUXUS® F502BT Technical specification
FLEXIM GmbH
Wolfener Str. 36
12681 Berlin
Germany
Tel.: +49 (30) 93 66 76 60
Fax: +49 (30) 93 66 76 80
internet: www.flexim.com
e-mail: [email protected]
Subject to change without notification. Errors excepted.
FLUXUS® is a registered trademark of FLEXIM GmbH.