11
| © Nordex 2019 | 22. Oktober 2019 | Classification: Internal Purpose Nordex Group Product Innovations Delta4000 Variants and Upgrades
Transcript
  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    Nordex Group

    Product InnovationsDelta4000 Variants and Upgrades

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    Delta 4000: Nacelle 100 produced this week in Rostock

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    First 20+ series turbines installed in the field as of October

    Scandinavia Germany

    21 serial turbines – N149 3 Prototypes – two N149 one N133

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    Full prototype testing and certification achieved

    Three prototypes thoroughly tested Type Certificate Obtained

    First 4 MW+ ~150m rotor wind turbine installed globally

    Installed & commissioned in Sept. 2018

    Performance as expected

    System validation complete

    Design Assessment obtained

    Type Certificate obtained

    power modes up to 4.8 MW included via VPC

    Power Curve Meeting Targets

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    Delta4000 product series – as basis for further product innovations

    5

    N149/5.XN133/4.8

    N155/4.5

    N163/5.X

    IEC 1 IEC 2

    Wind class

    IEC 3

    low

    hig

    h

    N149/4.0-4.5

    Sit

    e c

    om

    ple

    xit

    y

    (e.g

    . tu

    rb

    ule

    nce…

    )

    Turbine Public Release PT Installed Serial Start Type Certificate

    N149/4.0-4.5 09/2017 09/2018 03/2019 08/2019

    N133/4.8 04/2018 08/2019 03/2019 12/2019

    N149/5.X 03/2019 Q4/2020 Q1/2021 Q4/2021

    N155/4.X 05/2019 Q3/2020 Q3/2020 Q2/2021

    N163/5.X 08/2019 Q4/2020 Q1/2021 Q4/2021

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    One Nacelle – Two 5.X turbine variants

    6

    N149(NR74.5)

    N163(NR81.5)

    N149/5.X N163/5.X

    N149/4.0-4.5

    Basis:› Certified and proven

    Delta4000 technology

    Upgrade:› One nacelle – Two 5.X

    turbine variants

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    N163/5.X - Flexible rating

    7

    5.7 MW

    5.X MW

    5.5 MWMedium suitability (IEC S)

    2.58 MW

    Increasing power

    Increasing suitability, reduced sound

    5.2 MWlower sound

    high suitability

    N149 & N163/5.X

    N149 & N163/5.X is designed for a high flexibility and ensures maximum performance under various site conditions

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    N149 & N163/5.X - Overview technical changes compared to N149/4.0-4.5

    8

    Enhanced cooling system- Split in 2 circuits

    Adapted coupling- Higher nominal torque

    New gearbox & shrink disc - Higher nominal torque

    Enhanced pitch bearing

    Reinforced structural components

    Upgraded power transmission system - Higher rating 5.7 MW- Increased voltage level to 750V

    New rotor blade NR81.5

    Adapted spinner and rain deflector- Design adaption caused by rotor blade

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    N149 & N163/5.X - Timeline and milestones

    9

    2019 2020 2021

    Q3/Q42020

    PrototypeDECS

    Q3/Q42021

    Type Certification

    Q12021

    Serial Production

    Start

    Official Market Launch

    04/19

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    N163/5.X – AEP by WTG comparison in a typical medium wind site –LAND CONSTRAINED – 7.5m/s

    10

    N149/5.7N163/5.7N163/5.5

    gro

    ss A

    EP*

    N149/4.8N149/4.38

    +8,9%

    +17%+20%

    Wind Conditions

    measurement height [m] 125

    v_ave [m/s] 7.5

    weibull k [-] 2.2

    shear exponent [-] 0.25

    air density [kg/m³] 1.225

    *Based on a turbine level comparisonAssumed all WTGs at same hub height

    Comparable suitability levels

    AEP

    Strong performance

    and yield

  • |

    © Nordex 2019 | 22. Oktober 2019 |

    › Classification: Internal Purpose

    Further optimization potential to be leveraged with the project optimization toolkit

    Factoring Early Revenue Specific Tower COE Layout Opt

    Advanced Model.

    Specific Warranties

    AIS Warranty Variable PC

    Grid Optimization

    Full Weather Risk

    Technical Interactions

    Specific Costing


Recommended