(E) 36" X 18" (E) ELECTRICAL AHU 1 2 4 (E) DOMESTIC HOT WATER HEATER (E) OSA DUCT CONTROL PANEL (E) FLOOR SINK 16 X76 RA OPENING 3 1 15 6 (E) RA PLENUM 14 13 3 M200 2 M200 6 CHWS CHWR 7 11 10 9 8 12 (E) SUMP PUMP 5 6 M602 5 M601 3" 2 1/2" PF 1 1" CHILLER STRAINER BLOW DOWN DRAIN TO (E) FLOOR SINK 17 19 20 1 M601 3 M602 3 M601 21 2 M601 BT 1 23 1 9 13 12 11 10 9 13 12 11 10 9 13 12 11 10 N L H K J N L H K J N L H K J 4 66 2 13 16"X76" RA RA SA SD 1 M603 3 M602 16 22 CEILING 18 ZONE 1-1, 20X7 ZONE 1-2, 20X10 ZONE 1-3, 20X9 ZONE 1-4, 20X8 ZONE 1-5, 20X7 ZONE 2-1, 20X13 ZONE 2-2, 20X9 ZONE 2-3, 20X11 ZONE 2-4, 20X12 ZONE 1-6, 20X10 AHU 1 1 18 ZONE DAMPERS & DAMPER OPERATORS, BOTH DECKS (TYP) 18"X36" OSA 2 6 1 M603 3/4" COPPER CONDENSATE DRAIN TO (E) FLOOR SINK 5 M602 (TYP 10) (TYP 10) CEILING 1 ADDENDUM 1 10/02/17 Project Title Revisions Date Description Number Designed Drawn Checked Date Sheet Title Sheet Number Consultant Approved Scale Submittal P2S No. 7902 April 21,2017 DSA Submittal Building 3000 HVAC Upgrade 321 E Chapman Ave Fullerton, CA 92832 1 2 3 4 5 6 A B C D E FILE PATH & NAME: V:\CAD_DRAWINGS\J7902\MECHANICAL\7902_M2.0 MECH ROOM PLANS.DWG SEBASTIAN SALEM PLOT: Thursday, December 13, 2018 2:36:34 PM P2S Engineering, Inc. 5000 East Spring Street, 8th Floor Long Beach, CA 90815-5218 T 562.497.2999 F 562.497.2990 www.p2seng.com E F O R P D E R E T S I G E R R E E N I G N E L A N O I S S C A L I F O R N I A S T A T E O F No. M27619 M E C H A N I C A L C H R I S T O P H E R J . W E I X E L M A N SIGNED: 09/02/16 E F O R P D E R E T S I G E R R E E N I G N E L A N O I S S C A L I F O R N I A S T A T E O F SIGNED: 09/02/16 2 ADDENDUM 2 12/12/18 C Weixelman C Naranjo S Bandi C Weixelman As Noted Basement HVAC Plan M200 0 NORTH 4 SCALE: 1/4" = 1'-0" BASEMENT MECHANICAL ROOM 1/4"=1'-0" 1 NOTES INSTALL AHU-1 AT THE SAME LOCATION AS EXISTING. CONNECT TO CONDENSATE PIPING. REFER TO STRUCTURAL PLANS FOR SEISMIC ANCHORING ON SHEET S601. (E) 36 X 18 OSA DUCT CONNECTED TO THE (E) MIXED AIR PLENUM. 76 X 12 HOT AND COLD DECK OPENINGS. SIZE EACH ZONE SA DISCHARGE OPENING AND DAMPER PER AIR QUANTITY SHOWN FOR EACH ZONE.RECONNECT TO EACH ZONE SA DUCT WITH MANUAL DAMPER. (E) BOILER FLUE TO REMAIN IN PLACE. (E) 630 MBH BOILER TO REMAIN. PROVIDE NEW CONTROLLRE FOR INTEGRATION TO BMS. MAKE TRANSITION FROM EACH ZONE DISCHARGE OPENING TO EXISTING ZONE SA DUCT BELOW CEILING AND MAKE NEW CONNECTION (TYP 10) SET EACH ZONE AIR QUANTITY AS SHOWN. SUPPLY & RETURN CHILLED WATER PIPING TO CHILLER CH-1. SEE M-201 FOR CONTINUATION. RECONNECT TO (E) CHWS AND CHWR UP TO FIRST FLOOR. (E) HWS AND HWR PIPING RISER TO FIRST FLOOR TO REMAIN. RECONNECT HWS AND HWR TO HW COIL CONTROL VALVE. SEE DETAIL 5 ON M603 (E) HWS AND HWR TO REMAIN CONNECTED TO BOILER SYSTEM. 3" CHWS AND CHWR PIPE. CONNECT AHU-1 RA OPENING TO (E) RA PLENUM. (E) RA THROUGH CEILING CONNECTED TO (E) RA PLENUM. REPLACE EXISTING PUMP WITH A BASE MOUNTED END SUCTION PUMP RATED FOR 47 GPM @ 40 FEET AT 180°F SERVICE TEMPERATURE. THE CONTRACTOR SHALL VERIFY EXISTING PUMP MOTOR SIZE TO ENSURE THE ELECTRICAL SERVICE IS ADEQUATE. PROVIDE AND INSTALL MOTORIZED DAMPER ON (E) RA DUCT. 1" PVC SCH. 40 TO CHILLER BLOW DOWN CONNECTION WITH TRAP. FIELD VERIFY EXACT ROUTING. FLEX CONNECTION PROVIDE AND INSTALL MOTORIZED DAMPER ON (E) OSA DUCT. REPLACE THE SECTION OF THE OSA DUCT AS NECESSARY TO INSTALL THE MOTORIZED DAMPER. 3/4" WATER MAKEUP. (E) DOMESTIC CW LINE. FIELD VERIFY EXACT LOCATION. ZERO VELOCITY TYPE SMOKE DAMPER DETECTOR ON COLD DECK SA PLENUM. THE EXISTING SMOKE DETECTOR IS TO BE REMOVED FROM THE EXISTING AIR HANDLER AND RE-INSTALLED IN THE NEW AIR HANDLER. REFERENCE SHEET E002, MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 AHU-1 SIDE VIEW 1/2"=1'-0" 3 AHU-1 FRONT VIEW 1/2"=1'-0" 2 4 ZONE DAMPER & OPERATOR BOTH DECKS (TYP) 3 6 AHU 1 1 1 1 AHU-1 AIR FLOW ZONE COOLING DAMPER SIZE (WxH) HEATING DAMPER SIZE (WxH) MAX AIRFLOW (CFM) MIN AIRFLOW (CFM) 1-1 4.5x14 4.5x10 530 90 1-2 7x14 7x10 990 165 1-3 7x14 7x10 1,000 210 1-4 5x14 5x10 850 405 1-5 4.5x14 4.5x10 750 105 1-6 4.5x14 4.5x10 860 85 2-1 8x14 8x10 1,300 600 2-2 4.5x14 4.5x10 300 75 2-3 14x14 14x10 1,800 600 2-4 8x14 8x10 1,300 180 TOTAL 9,700 2,515 1 2 2 2
Transcript

(E) 36" X 18"

(E) ELECTRICAL

AHU

1

2

4

(E) DOMESTIC HOT WATER HEATER

(E) OSA DUCT

CONTROL PANEL

(E) FLOOR SINK

16 X76 RA OPENING

3

1

15

6

(E) RA PLENUM

14

13

3

M200

2

M200

6

CHWSCHWR

7

11

10

98 12

(E) SUMP PUMP

5

6

M602

5

M601

3"

2 1/2"

PF

1

1" CHILLER STRAINER BLOW DOWN DRAINTO (E) FLOOR SINK

17

19

20

1

M601

3

M602

3

M601

21

2

M601

BT

1

23

1

9 131211109 131211109 13121110

N

L

H

K

J

N

L

H

K

J

N

L

H

K

J

4

66

2

13

16"X76" RA

RA SA

SD

1

M603

3

M60216

22

CEILING

18

ZONE 1-1, 20X7

ZONE 1-2, 20X10

ZONE 1-3, 20X9

ZONE 1-4, 20X8

ZONE 1-5, 20X7

ZONE 2-1, 20X13

ZONE 2-2, 20X9

ZONE 2-3, 20X11

ZONE 2-4, 20X12

ZONE 1-6, 20X10

AHU

11

18

ZONE DAMPERS& DAMPER OPERATORS,BOTH DECKS (TYP)

18"X36" OSA

26

1

M603

3/4" COPPER CONDENSATEDRAIN TO (E) FLOOR SINK

5

M602

(TYP 10)

(TYP 10)

CEILING

1 ADDENDUM 1 10/02/17

Project Title

RevisionsDateDescriptionNumber

DesignedDrawnChecked

Date

Sheet Title

Sheet Number

Consultant

Approved

Scale

Submittal

P2S No. 7902

April 21,2017

DSA Submittal

Building 3000 HVAC Upgrade

321 E Chapman AveFullerton, CA 92832

1 2 3 4 5 6

A

B

C

D

E

FILE

PA

TH &

NA

ME

: V:\C

AD

_DR

AW

ING

S\J

7902

\ME

CH

AN

ICA

L\79

02_M

2.0

ME

CH

RO

OM

PLA

NS

.DW

G S

EB

AS

TIA

N S

ALE

MP

LOT:

Thu

rsda

y, D

ecem

ber 1

3, 2

018

2:36

:34

PM

P2S Engineering, Inc.

5000 East Spring Street, 8th Floor

Long Beach, CA 90815-5218

T 562.497.2999 F 562.497.2990

www.p2seng.com

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

No. M27619

M E C H A N I C A L

CH

RI S

T O

PHE R J . WE

I XE

LM

AN

SIGNED: 09/02/16

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

SIGNED: 09/02/16

2 ADDENDUM 2 12/12/18

C WeixelmanC Naranjo

S Bandi

C Weixelman

As Noted

Basement HVAC Plan

M200

0

NORTH

4

SCALE: 1/4" = 1'-0"

BASEMENT MECHANICAL ROOM1/4"=1'-0"1

NOTESINSTALL AHU-1 AT THE SAME LOCATION AS EXISTING.CONNECT TO CONDENSATE PIPING. REFER TOSTRUCTURAL PLANS FOR SEISMIC ANCHORING ON SHEETS601.

(E) 36 X 18 OSA DUCT CONNECTED TO THE (E) MIXED AIRPLENUM.

76 X 12 HOT AND COLD DECK OPENINGS. SIZE EACHZONE SA DISCHARGE OPENING AND DAMPER PER AIRQUANTITY SHOWN FOR EACH ZONE.RECONNECT TO EACHZONE SA DUCT WITH MANUAL DAMPER.

(E) BOILER FLUE TO REMAIN IN PLACE.

(E) 630 MBH BOILER TO REMAIN. PROVIDE NEWCONTROLLRE FOR INTEGRATION TO BMS.

MAKE TRANSITION FROM EACH ZONE DISCHARGEOPENING TO EXISTING ZONE SA DUCT BELOW CEILINGAND MAKE NEW CONNECTION (TYP 10) SET EACH ZONEAIR QUANTITY AS SHOWN.

SUPPLY & RETURN CHILLED WATER PIPING TO CHILLERCH-1. SEE M-201 FOR CONTINUATION.

RECONNECT TO (E) CHWS AND CHWR UP TO FIRSTFLOOR.

(E) HWS AND HWR PIPING RISER TO FIRST FLOOR TOREMAIN.

RECONNECT HWS AND HWR TO HW COIL CONTROLVALVE. SEE DETAIL 5 ON M603

(E) HWS AND HWR TO REMAIN CONNECTED TO BOILERSYSTEM.

3" CHWS AND CHWR PIPE.

CONNECT AHU-1 RA OPENING TO (E) RA PLENUM.

(E) RA THROUGH CEILING CONNECTED TO (E) RA PLENUM.

REPLACE EXISTING PUMP WITH A BASE MOUNTED ENDSUCTION PUMP RATED FOR 47 GPM @ 40 FEET AT 180°FSERVICE TEMPERATURE. THE CONTRACTOR SHALL VERIFYEXISTING PUMP MOTOR SIZE TO ENSURE THE ELECTRICALSERVICE IS ADEQUATE.

PROVIDE AND INSTALL MOTORIZED DAMPER ON (E) RADUCT.

1" PVC SCH. 40 TO CHILLER BLOW DOWN CONNECTIONWITH TRAP. FIELD VERIFY EXACT ROUTING.

FLEX CONNECTION

PROVIDE AND INSTALL MOTORIZED DAMPER ON (E) OSADUCT. REPLACE THE SECTION OF THE OSA DUCT ASNECESSARY TO INSTALL THE MOTORIZED DAMPER.

3/4" WATER MAKEUP.

(E) DOMESTIC CW LINE. FIELD VERIFY EXACT LOCATION.

ZERO VELOCITY TYPE SMOKE DAMPER DETECTOR ONCOLD DECK SA PLENUM.

THE EXISTING SMOKE DETECTOR IS TO BE REMOVED FROMTHE EXISTING AIR HANDLER AND RE-INSTALLED IN THE NEW AIRHANDLER. REFERENCE SHEET E002, MECHANICAL EQUIPMENTELECTRICAL CONNECTION SCHEDULE.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

AHU-1 SIDE VIEW1/2"=1'-0"3 AHU-1 FRONT VIEW

1/2"=1'-0"2

4

ZONEDAMPER& OPERATORBOTH DECKS(TYP)

3

6

AHU

11

1

1

AHU-1 AIR FLOWZONE

COOLING DAMPERSIZE (WxH)

HEATING DAMPERSIZE (WxH)

MAX AIRFLOW(CFM)

MIN AIRFLOW(CFM)

1-1 4.5x14 4.5x10 530 90

1-2 7x14 7x10 990 165

1-3 7x14 7x10 1,000 210

1-4 5x14 5x10 850 405

1-5 4.5x14 4.5x10 750 105

1-6 4.5x14 4.5x10 860 85

2-1 8x14 8x10 1,300 600

2-2 4.5x14 4.5x10 300 75

2-3 14x14 14x10 1,800 600

2-4 8x14 8x10 1,300 180

TOTAL 9,700 2,515

1

2

2

2

S

R

Q

P

N

L

H

G

F

D

C

B

A

K

J

N

S

1 3 4 6

1 3 4 5 6 7 8 9 14131211102

2 5

Q

P

L

K

H

R

7 8 9 1413121110

G

F

D

C

B

A

J

T

TT

(E)10" x 7"

(E)14" X 8"(E)10" X 6" (E)18" X 10"

(E)10" x 6"

(E)12" X 10"

(E)18" x 10"

(E)12" X 10"

(E)10" X 6" (E)10" X 8" (E)12" X 9" (E)8" X 6"

(E)22" X 10"

(E)10" X 6" (E)12" X 8"

(E)26" X 10"

(E)12" X 10"

(E)10" X 8" (E)8" X 6"

(E)15" X 8"(E)16" X 10"

(E)10" X 7"

(E)8" X 10"

(E)8" X 10"

(E)12" X 8"

(E)8" X 6"

(E)8" X 6"

(E)8" X 6"

T

(E)10" X 7"

(E)20"x10"(E)12"x10"

(E)12"Ø STACK

(E)16"x10"

(E)12"X8"

(E)12"X6"

FACILITIESELEC/PLUMB

BREAKROOM

CORRIDOR

CORRIDOR

LOBBY

STAIRMEN'SWOMEN'S

CLASSROOM FACILITIESWOODSHOP

CH

1

FACILITIESLOCKSMITH

OFFICE

T

STOR./TELE EQUIP

(E)10" X 8"

(E)10"x8" EXHAUST UP

(E)30"x12"

(E)16"x12"

(E)36"x24" RA OPENING

(E)12"x8"

(E)10"x6" EA UP

1

M200 4

1

32

ZONE 1-1 ZONE 1-3

ZONE 1-2 ZONE 1-4

ZONE 1-6ZONE 1-5

42"

48"

T 1-5

1-6

1-4

1-2

1-3

1-1

5

SEE BASEMENTLEVEL

175 CFM

200 CFM200 CFM

330 CFM 330 CFM330 CFM

300 CFM

210 CFM 210 CFM

130 CFM

430 CFMTYP. 2

250 CFM 250 CFM

250 CFM

(E) 2"

3/4" CW

200 CFM200 CFM200 CFM

4

M602

2 1/2" CHWS/R

6

6

6

6

6

74

M603

4

M601

4

M601

9

6

(E)12"X6" (E)12"X6"

8

180 CFM

180 CFM

42"

42"

(E)13"X10"180 CFM

175 CFM

(E)FD(E)FD

FM10 FM10

FM10

1 1

1

1 ADDENDUM 1 10/02/17

Project Title

RevisionsDateDescriptionNumber

DesignedDrawnChecked

Date

Sheet Title

Sheet Number

Consultant

Approved

Scale

Submittal

P2S No. 7902

April 21,2017

DSA Submittal

Building 3000 HVAC Upgrade

321 E Chapman AveFullerton, CA 92832

1 2 3 4 5 6

A

B

C

D

E

FILE

PA

TH &

NA

ME

: V:\C

AD

_DR

AW

ING

S\J

7902

\ME

CH

AN

ICA

L\79

02_M

2.1

FIR

ST

FLO

OR

PLA

N.D

WG

SE

BA

STI

AN

SA

LEM

PLO

T: T

hurs

day,

Dec

embe

r 13,

201

8 2:

36:4

2 P

M

P2S Engineering, Inc.

5000 East Spring Street, 8th Floor

Long Beach, CA 90815-5218

T 562.497.2999 F 562.497.2990

www.p2seng.com

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

No. M27619

M E C H A N I C A L

CH

RI S

TO

PHE R J . WE

I XE

LM

AN

SIGNED: 09/02/16

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

SIGNED: 09/02/16

2 ADDENDUM 2 12/13/18

C WeixelmanC Naranjo

S Bandi

C Weixelman

1/8" = 1'-0"

First Floor HVAC Plan

M2010

NORTH

8

SCALE: 1/8" = 1'-0"

NOTES(E) CHWS/CHWR AND HWS/HWR TO MEZZANINE LEVELMECHANICAL ROOM NEW AHU-2.

CHILLER TO BE INSTALLED ON THE EXISTING 4"CONCRETE PAD WITH CLEARANCE ON ALL 4 SIDES ASSHOWN.

(E) CHAIN LINK FENCE TO REMAIN.

RELOCATE CHAIN LINK FENCE TO PROVIDE CLEARANCEAS SHOWN.

CHWS AND CHWR THROUGH WALL TO MECHANICALROOM IN BASEMENT. SEE M200 FOR FURTHERINFORMATION.

PROVDE ZONE THERMOSTAT INTEGRATED WITH BUILDINGMANAGEMENT SYSTEM (TYP).

CONNECT 3/4" WATER MAKE UP WITH RPBFP & ISOLATIONVALVE TO CHILLER CH-1.

1" PVC SCHEDULE 40 FOR CHILLER BLOW DOWN TO (E)FLOOR SINK IN MECHANICAL ROOM @ 2% SLOPE MIN.

2ND FLOOR SA DUCTS. SEE M202.

PROVIDE AND INSTALL ONE FLOW METER FOR EACHZONE. FIELD VERIFY DUCT SIZE. INSTALLATION SHALL BEIN FULL COMPLIANCE WITH MANUFACTURER'SINSTALLATION GUIDELINES.

1

2

3

4

5

6

7

8

9

10

GENERAL NOTE1. ALL DUCTWORK IS EXISTING TO REMAIN ON THIS FLOOR.

2. PROVIDE AND INSTALL NEW THERMOSTATS FOR EACHZONE.

3. NO DUCT CLEANING IS REQUIRED BUT DUCTWORK WHICH ISACCESSIBLE (NOT REQUIRING THE DEMOLITION OF THECEILING) SHALL BE INSPECTED FOR LEAKS. ANY LEAKS DETECTEDSHALL BE SEALED. PRIOR TO THE REMOVAL OF THE EXISTINGAIR HANDLERS AND WHILE THERE ARE STILL IN OPERATION,THE CONTRACTOR SHALL PERFORM AN AUDIO, VISUALINSPECTION OF ALL EXISTING DUCTWORK WHICH IS VISIBLE INTHE CEILING/ATTIC SPACE AND MECHANICAL ROOMS. ANYSECTIONS OF DUCTWORK WHERE LEAKS ARE DETECTED SHALLHAVE THE EXTERIOR INSULATION REMOVED, HAVE ALL JOINTSSEALED AND BE REINSULATED. DUCTWORK WHICH ISINTERNALLY LINED ONLY NEEDS TO BE SEALED ON THEOUTSIDE.

4. REBALANCE ALL EXISTING DIFFUSERS TO INDICATEDAIRFLOWS.

1

1

2

S

R

Q

P

N

L

H

G

F

D

C

B

A

K

J

N

S

1 3 4 6

1 3 4 5 6 7 8 9 14131211102

2 5

Q

P

L

K

H

R

7 8 9 1413121110

G

F

D

C

B

A

J

S

R

Q

P

N

L

H

G

F

D

C

B

A

K

J

N

S

1 3 4 6

1 3 4 5 6 7 8 9 14131211102

2 5

Q

P

L

K

H

R

7 8 9 1413121110

G

F

D

C

B

A

J

WOMEN STAIRMEN

ASSESSMENT CENTER CONFERENCE ROOM

BDF

CORRIDOR

ELECTRICAL

T

T

T

T

T

T

ASSESSMENT CENTER

ASSESSMENT CENTER

ASSESSMENT CENTER

LOCKERS

RECEPTION

CLASSROOMFACILITIESPLAN ROOM

FACILITIESPLAN ROOM

FACILITIESOFFICE

FACILITIESOFFICE

CORRIDORCORRIDOR

CORRIDOR

OFFICE

OFFICE

CONFERENCE

TOILET

MEN'S WOMEN'S

CORRIDOR

CLASSROOM

BREAK ROOM

OFFICE

OFFICE

OFFICE

COPY

LOBBY

TT

OFFICE

MEZZANINE MECHANICAL ROOMABOVE

1

M301

ZONE HP-1 ZONE HP-2

ZONE 2-3

ZONE 2-4

ZONE M-3

ZONE M-2

ZONE M-1

ZONE M-5

ZONE M-4

8 X1

4

10 X

12

14 X

22

12 X

14

(E) 8 X 12

42 X

14

RA

2-4

HP-1

7

HP-2

9

T

3

7

170 CFM

7

77

1

ZONE 2-2

120 CFM

170 CFM

100 CFM

100 CFMTYP 2

14

(E) 2" CHWS(E) 2" CHWR(E) 2" HHWS(E) 2" HHWSTO MEZZANINE

MECHANICAL ROOM

12"Ø

8"ØTYP

320 CFMTYP 2

320 CFM

195 CFM(TYP 2)

105 CFM

430 CFM 435 CFM435 CFM

287 CFMTYP 2

200 CFM

310 CFM

225 CFM

225 CFM

225 CFM

225 CFM

225 CFM

2

12"Ø

6

330 CFM

280 CFM

430 CFM330 CFM

330 CFM

330 CFM330 CFM330 CFM

435 CFM 435 CFM

280 CFM

280 CFM

280 CFM

280 CFM 280 CFM

M-1

M-2

M-4

M-3

T

1313

1

10

4

1

330 CFM200 CFM

350 CFM150 CFM

8

8

9

9 9

12

5

TYP HP-1

TO HP-1 TO HP-2

8" Ø

10" Ø

10" Ø

12" Ø

12" Ø

8" Ø

8" Ø

10" Ø

10" Ø

10" Ø

10" Ø

10" Ø

10" Ø

10" Ø

12" Ø

10" Ø

10" Ø

12" Ø

10" Ø

10" Ø

12" Ø

10" Ø

10" Ø8" Ø

8" Ø

12" Ø

24 X 24 RG-1(TYP2 ZONE)

24 X 24

22 X 16 22 X 12 14 X 12

2-2

400 CFM

100 CFM

M-5

6

M601

8" Ø

8" Ø

1515

15

15

15

12 X 12 RG-1(TYP THIS ZONE)

24 X 24 CD-1(TYP THIS ZONE)

24 X 24 RG-1

24 X 24 CD-1(TYP THIS ZONE)

TYP

2

M602TYP

16" Ø

6

M603

6

M603

16" Ø

6

M603

6

M601TYP

9

8

8

8

11

11

11

11

11

140 CFM

140 CFM

190 CFM

11

11

ZONE 2-1

180 CFM

180 CFM 8X10

1

1

1

1

1

FM

FM

FM

FM16 16

1

FM

FM

FM

FM

FM

16

16

16

1

1 ADDENDUM 1 10/02/17

Project Title

RevisionsDateDescriptionNumber

DesignedDrawnChecked

Date

Sheet Title

Sheet Number

Consultant

Approved

Scale

Submittal

P2S No. 7902

April 21,2017

DSA Submittal

Building 3000 HVAC Upgrade

321 E Chapman AveFullerton, CA 92832

1 2 3 4 5 6

A

B

C

D

E

FILE

PA

TH &

NA

ME

: V:\C

AD

_DR

AW

ING

S\J

7902

\ME

CH

AN

ICA

L\79

02_M

2.2

SE

CO

ND

FLO

OR

PLA

N.D

WG

SE

BA

STI

AN

SA

LEM

PLO

T: T

hurs

day,

Dec

embe

r 13,

201

8 2:

36:4

4 P

M

P2S Engineering, Inc.

5000 East Spring Street, 8th Floor

Long Beach, CA 90815-5218

T 562.497.2999 F 562.497.2990

www.p2seng.com

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

No. M27619

M E C H A N I C A L

CH

RI S

TO

PHE R J . WE

I XE

LM

AN

SIGNED: 09/02/16

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

SIGNED: 09/02/16

2 ADDENDUM 2 12/12/18

C WeixelmanC Naranjo

S Bandi

C Weixelman

1/8"= 1'-0"

Second Floor HVAC Plan

M2020

NORTH

8

SCALE: 1/8" = 1'-0"

NOTES1. CLEAN & SEAL ALL DUCT WORK.

2. PROVIDE & INSTALL THERMOSTATS FOR EACH ZONE ANDROOFTOP EQUIPMENT.

3. REBALANCE ALL EXISTING DIFFUSERS TO INDICATEDAIRFLOWS.

4. CONTRACTOR TO PAINT THE ENTIRE CEILING IN EVERYROOM WHERE AIR DISTRIBUTION HAS BEEN ALTERED.

NOTESCAP (E) SUPPLY AIR DUCT AT THIS LOCATION ANDREMOVE THE REMAINING PORTION.

REFER TO SHEET M200 FOR SECOND FLOOR ZONE SADUCTS.

DISCONNECT FROM ZONE 2-4 & CONNECT TO ZONE 2-2AS SHOWN.

DISCONNECT FROM (E) CHILLED WATER FAN COIL SYSTEM& CONNECT TO ZONE 2-2 AS SHOWN with 8"Ø.

(E) SA DUCT TO REMAIN.

DISCONNECT FROM (E) ZONE 2-3 SA DUCT ANDRECONNECT ZONE 2-4 AS SHOWN.

(E) 30" X 30" CEILING ACCESS TO TRANSFER PLANKSABOVE TO THE (E) SUSPENDED FRAMED WIRE MESH LATH& PLASTER. CEILING FOR DUCTWORK MODIFICATION ,CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TOTHE (E) CEILING.

(E) CEILING DIFFUSER SERVED BY HP-1 TO REMAIN.

(E) RA TO REMAIN CONNECTED. TO (E) MAIN RA DUCT

PROVIDE AND INSTALL THERMOSTAT TO CONTROL ZONES2-1 AND 2-3 AS SHOWN ON AHU-1 AIRFLOW CHART ONSHEET M-200.

ALL (E) SUPPLY AND RETURN GRILLS TO REMAIN AS-IS.

(E) BOILER VENT.

(E) SA & RA PLENUM TO REMAIN. ALL DUCT WORKCONNECTED TO (E) SA & RA PLENUM ARE NEW. PROVIDEAND INSTALL DUCT LINING ON 4' HORIZONTALRECTANGULAR SUPPLY AND RETURN DUCT. SEE DETAIL 1ON M602

DISCONNECT (E) RETURN AIR GRILLE FROM (E) CHILLEDWATER FAN COIL AND MAKE (N) CONNECTION TO AHU-1(E) RETURN AIR DUCT.

PATCH (E) CEILING OPENINGS TO MATCH EXISTING. SEEDEMO PLAN SHEET MD202 FOR REMOVED SA REGISTERS.COORDINATE EXACT LOCATION OF SA & RA GRILLES WITH(E) LIGHTS & OTHER EQUIPMENT AT THE CEILING.

PROVIDE AND INSTALL FLOW METER FOR EACH ZONE.FIELD VERIFY DUCT SIZE. INSTALLATION SHALL BE IN FULLCOMPLIANCE WITH MANUFACTURER'S INSTALLATIONGUIDELINES.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

1

2

MEZZ MECH ROOM

(E) 78"x48" LOUVER(OVERALL DIMENSION)

(E) 10"x18" SA ZONE M-4(E) 22"x18" SA ZONE M-1

(E) 8"x18" SA ZONE M-2

(E) 6"x18" SA ZONE M-3

(E) 10"x6" SA

(E) 18"x12" SA ZONE M-5

(E) 42"x14" RA

(E)1-1/4"HHWS & HWR

(E)2"CHWS & CHWR

6

1

2

3

4

AHU

210

2

M30148"x48" HINGED LOUVERFOR ACCESS TO MECHANICALROOM

9

FIXED OSA INTAKE LOUVER

11

654

654

3

M602

13

1

16

3

M603

16

17

24"

36"

FLOOR

118"

3

24

5

7

18"

HOT

COLD

9

9SUPPORT CHANNELS

16X428

10"

SUPPORT CHANNELS

AHU

2

3

M603

3

M602

VD

SD

14

15

1

H G

H

G

1 ADDENDUM 1 10/02/17

Project Title

RevisionsDateDescriptionNumber

DesignedDrawnChecked

Date

Sheet Title

Sheet Number

Consultant

Approved

Scale

Submittal

P2S No. 7902

April 21,2017

DSA Submittal

Building 3000 HVAC Upgrade

321 E Chapman AveFullerton, CA 92832

1 2 3 4 5 6

A

B

C

D

E

FILE

PA

TH &

NA

ME

: V:\C

AD

_DR

AW

ING

S\J

7902

\ME

CH

AN

ICA

L\79

02_M

3.1

EN

LAR

GE

D P

LAN

S.D

WG

SE

BA

STI

AN

SA

LEM

PLO

T: T

hurs

day,

Dec

embe

r 13,

201

8 2:

36:4

6 P

M

P2S Engineering, Inc.

5000 East Spring Street, 8th Floor

Long Beach, CA 90815-5218

T 562.497.2999 F 562.497.2990

www.p2seng.com

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

No. M27619

M E C H A N I C A L

CH

RI S

TO

PHE R J . WE

I XE

LM

AN

SIGNED: 09/02/16

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F ORN

I AST

AT E

O F

SIGNED: 09/02/16

2 ADDENDUM 2 12/12/18

C WeixelmanC Naranjo

S Bandi

C Weixelman

As Noted

Enlarged Mechanical RoomsHVAC Plan

M3010

NORTH

4

SCALE: 1/4" = 1'-0"

ENLARGED MECHANICAL ROOM - MEZZANINE LEVEL1/4"=1'-0"1

NOTES(E) ROUND SA DUCT TO REMAIN RECONNECTED TO ZONEM-5 SA DUCT.

(E) OSA INTAKE TO REMAIN.

(E) RA DUCT BEYOND TO REMAIN CONNECTED TO THEMIXED AIR PLENUM.

RECONNECT (E) MIXED AIR PLENUM TO RA OPENING OFTHE AHU-2 WITH FLEX CONNECTION.

AHU-2 RA OPENING.

(E) CHWS/CHWR AND HWS/HWR TO BE RECONNECTED TOAHU-2 HW AND CHW COILS. SEE DETAIL 5 ON M603.

ZONE SA BALANCING DAMPER. IN ATTIC SPACE.

(E) MIXED AIR PLENUM.

AHU-2 ZONE DAMPERS AND DAMPER OPERATORS.

AHU-2 TO BE INSTALLED ON SUPPORT CHANNELS PERSTRUCTURAL DRAWINGS. SEE SHEET S601, DETAIL #4.

PROVIDE MOTORIZED DAMPER AND DAMPER OPERATORON (E) OUTSIDE OSA DUCT.

NOT USED

PROVIDE MOTORIZED DAMPER AND DAMPER OPERATORON RA DUCT.

THE EXISTING SMOKE DETECTOR SHALL BE REMOVED,REINSTALLED AND RECONNECTED TO THE EXISTING FIRE ALARMSYSTEM.

PROVIDE ACCESS DOORS ON (E) SA DUCT (TYP 5).

REMOVE AND REPLACE THE SECTION OF THE DUCT ASNECESSARY TO INSTALL NEW DAMPER.

THE EXISTING SMOKE DETECTOR IS TO BE REMOVED FROM THEEXISTING AIR HANDLER AND RE-INSTALLED IN THE NEW AIRHANDLER. REFERENCE SHEET E002, MECHANICAL EQUIPMENTELECTRICAL CONNECTION SCHEDULE.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

AIR HANDLING UNIT-21"=1'-0"2

1

1

AHU-2 AIR FLOWZONE

COOLING DAMPERSIZE (WxH)

HEATING DAMPERSIZE (WxH)

MAX AIRFLOW(CFM)

MIN AIRFLOW(CFM)

M-1 10.5x30 10.5x24 1,300 510

M-2 4.5x30 4.5x24 490 120

M-3 5x30 5x24 575 55

M-4 9.5x30 9.5x24 1,185 330

M-5 4.5x30 4.5x24 450 135

TOTAL 4,000 1,150

1

1

2

2

2

1 ADDENDUM 1 10/02/17

Project Title

RevisionsDateDescriptionNumber

DesignedDrawnChecked

Date

Sheet Title

Sheet Number

Consultant

Approved

Scale

Submittal

P2S No. 7902

April 21,2017

DSA Submittal

Building 3000 HVAC Upgrade

321 E Chapman AveFullerton, CA 92832

1 2 3 4 5 6

A

B

C

D

E

FILE

PA

TH &

NA

ME

: V:\C

AD

_DR

AW

ING

S\J

7902

\ME

CH

AN

ICA

L\79

02_M

6.2

DE

TAIL

S.D

WG

SE

BA

STI

AN

SA

LEM

PLO

T: T

hurs

day,

Dec

embe

r 13,

201

8 2:

36:5

1 P

M

P2S Engineering, Inc.

5000 East Spring Street, 8th Floor

Long Beach, CA 90815-5218

T 562.497.2999 F 562.497.2990

www.p2seng.com

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F OR N

I AST

AT E

O F

No. M27619

M E C H A N I C A L

CH

RI S

T O

PHE R J . WE

I XE

LM

AN

SIGNED: 09/02/16

EFORPDE

RE

TSI

GE

R RE

ENI

GNE

LANOISS

C A L I F OR N

I AST

AT E

O F

SIGNED: 09/02/16

2 ADDENDUM 2 12/13/18

C WeixelmanC Naranjo

S Bandi

C Weixelman

No Scale

Details

M602

DETAIL "A"

MAX C/L16"

3" 3"

9

5

4

6

7

8

1

10

3

1

2

11

NOTESDUCT.

LINING.

ALL ENDS OF LINER. COATED WITH ADHESIVE.

NOT MORE THAN 3" FROM EDGE OF LINER.

TYPICAL STUD-WELDED PINS AND SPEED CLIP WASHER (SEEDETAIL 'A')

COATED SURFACE OF INSULATION EXPOSED TO AIRSTREAM.

1

2

3

4

5

6

DUCT LINING INSTALLATIONNO SCALE1

PINS SPOT WELDED TO DUCTWORK.

SEPARATE SPEED CLIP WASHER.

WASHER DOWN OVER PIN TO LINING.

WELD-PIN STUD WELDED TO DUCT (PIN FASTENED TO DUCTWITH ADHESIVE NOT APPROVED).

ADHESIVE OVER COMPLETE SURFACE OF DUCT.

7

8

9

10

11

CHILLED WATER BUFFER TANKNO SCALE2

FRAME

INSULATION

FOAM GASKET

W/ # 10 SMS AT 6" O.C.STOP TO OPENING FRAME20 GA. ANGLE ATTACH

24 GA. G.I.STEEL

24 GA. G.I.DOOR

1",1 1/2 LBCOATEDFIBERGLASS

"RUSKIN" ACCESS DOORADH2 - MAX. SIZE 24"x24"

CONTINUOUSHINGE

STARTER TAB

SECTION A

TERMINATION POINT

DUCT

OF INSULATION

ACCESS DOOR

SMS AT 6" O.C.

A CAM LATCH

SECURE OPENINGFRAME W/ # 10

DUCT ACCESS DOORNO SCALE3

1 7

8

9

10

6

2

3

4

5

NOTESBASE MOUNTED END SUCTION CENTRIFUGAL PUMP MOUNTEDONTO CONCRETE PAD PER MANUFACTURER'SRECOMMENDATION. FILL PUMP BASE WITH CONCRETE. PIPEPUMP DRAIN TO NEAREST FLOOR SINK.

BUTTERFLY VALVE, LINE SIZE.

FLEXIBLE PIPE CONNECTION.

SUCTION DIFFUSER. PIPE SUCTION DIFFUSER DRAIN TONEAREST FLOOR SINK.

PIPE REDUCER/ENLARGER.

1

2

3

4

5

BASE MOUNTED CENTRIFUGAL PUMP CONNECTIONNO SCALE6

CHECK VALVE, GLOBE TYPE, SPRING LOADED, LINE SIZE.

BALL VALVE.

SCHEDULE 20, 304 STAINLESS STEEL PIPE.

SNUBBER.

PRESSURE GAUGE.

PROVIDE AN 18” W X 24” L X 4” H HOUSEKEEPING PAD. PAD SHALLBE PLACED ON TOP OF THE EXISTING CONCRETE FLOOR WITH (4)- 6” NO. 4 REBAR LOCATED AT EACH CORNER 3” FROM THE EDGE OFPAD EPOXIED INTO THE FLOOR WITH 3” EMBEDMENT. PROVIDENO. 4 REBAR 2” FROM TOP AND 3” FROM THE EDGE OF PADAND 12” O.C.

6

7

8

9

10

11

DRAW THRU UNITBLOW THRU UNIT

H

1"

H / 2 MINIMUM

H

H = FAN OUTLET PRESSURE (" W.C.) + 1/2" W.C. (MIN) H = FAN INLET PRESSURE (" W.C.) + 1.0" W.C.

2

1

2

1

NOTESAIR HANDLING UNIT DRAIN PAN, DRAIN LINE SHALL BE ATLEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN ORAS INDICATED ON THE DRAWINGS.

SLOPE CONDENSATE DRAIN TO RECEPTOR AT 18" PER FOOT.

1

2

CONDENSATE TRAPNO SCALE5

PIPE

OUTSIDE

WATER PROOF LINKSEAL ASSEMBLY

INSIDE

CONCRETE WALL

NOTES1. PIPE SLEEVE SIZE SHALL CONFORM WITH LINK SEAL MFG'S

REQUIREMENTS.

PIPE PENETRATION THROUGH CONCRETE WALLNO SCALE4

(E) HW PUMP

EXISTING CONCRETE FLOOR

MIN. SIZE PER DUCT DIMENSION

NOTES1. DUCT DIMENSIONS SHOWN ON PLANS ARE CLEAR INSIDE DIMENSIONS

1/2" Ø HILTI ICBTZ (2-3/8" EMBEDDED)QTY: 4 TOTAL

INSULATION

18" MAX

NOTES

THERMAL INSULATION.

NOTCH IN LEG FOR WELD.

38"X38"X4" HIGH HOUSEKEEPING PAD, SEE 6/S601.

2-1/2"X2-1/2"X1/4" STEEL ANGLE LEGS AND 6"X6"X1/4"BASEPLATES WITH 3/4"Ø HOLE IN EACH PLATE ON 30-7/8"BOLTCIRCLE.

1

2

3

4

1" NPT DRAIN.

BAFFLE PLATE.

3/4" VENT.

EXISTING FLOOR SLAB.

(1) - 5/8" DIAMETER HILTI KBTZ WITH 4" EMBEDMENT PER BASEPLATE (1CC ESR-1917).

5

6

7

8

9

"F" INLET "F" OUTLET

1

2

3

4

5

6

7

8

NOTES1. 740 LBS, WITH WATER.

1 9

2

11

2