Nuaire Positive Input Ventilation
Daniel EvansApril 2015
Why Do We Ventilate?
Ventilation helps to promote a healthy, clean environment
Designed to remove stale odours & replace with fresh air
Prevent build up of excessive moisture & humidity
Removes excessive C0₂ generated by humans & pets
Lack of Ventilation - Effects
Condensation Mould Growth
Dust Mites / Allergies
Smells & Odours
Rn (222)
Radon
Radioactive, Colourless, Odourless gas. Rises from the ground Estimated 100,000 homes have a concentration above safe level 200Becquerel per m2.
How We Generate Moisture (BBCC)
Cooking
Cleaning
Bathing
Average person generates 4 pints of moisture per day
Breathing
Moisture:
Bathing, Breathing , Cooking & Cleaning generates moisture which is absorbed into the air (Like the tap running into the sponge)
Your Properties air will accept a certain amount of moisture and hold onto it without dripping
Once full the sponge leaks as it cannot hold anymore moisture (like in the air in your house)
Once the sponge is leaking moisture forms on your windows and walls as the air is now full and cannot accept any more
YOUR PROPERTIES AIR IS LIKE A SPONGE
How Do We Explain Moisture In The Home?
Condensation is caused when moisture held in the air meets a cold surface like a window or wall and condenses into water droplets.
When we Bathe, Breathe Cook & Clean we create moisture which results in condensation
It often results in black mould growth on walls and other surfaces or you can see actual water droplets. It is usually worse in corners, on or near windows, in or behind wardrobes and cupboards.
What Is Condensation:How Do We Explain Condensation In The Home?
Always Coca Cola!!!
CONDENSATION - THE MAIN CAUSE OF MOULD GROWTH
Moisture & Condensation:
Moisture created in the bathroom from showering
Once you open the door the moisture looks to escape to the coldest part of the house
Below shows the result of poor ventilation within your home
Further Issues: • Current Regulations & Standards drive buildings to save energy and
reduce gaps in properties – lower fuel bills & save money
Loft Insulation
Cavity Wall Insulation
Double Glazing
CondensationAll of the above measures reduce air leakage
The Solution
Positive Input Ventilation (PIV)
PIV - The History • Nuaire are the originators
of PIV Systems developed with North Eastern Gas Board
• Over ½ Million Nuaire PIV Systems installed in the UK
• Used by Local Authorities & Housing Associations all over the UK
• Independently Tested by independent bodies such as Napier University Report & Document IP/1200 by BRE
HHSRS - Category 1 Health Hazard!
MOULD GROWTH IS CATEGORY 1! (SERIOUS RISK) Local authorities are under a duty to take action
against category 1 hazards which include Damp and Mould Growth.
As Landlords you have a responsibility under the Housing Health and Safety Rating System (HHSRS) to assess hazards and risks within your rental properties.
Leaving mould present in property causes serious health issues, causing some tenants to successfully claim compensation from Landlords.
PIV - How It Works 1) Clean, fresh air is continuously drawn in to the loft space through the loft’s natural leakage points
3) The air is then passed through the filters, and is gently fed into the dwelling via a central hallway diffuser
2) The warm air then rises to the highest point, gaining heat energy giving you the benefit of some heat recovery
4) The air then gently pressurises the house from inside out, driving out the moisture and condensation
5) This process creates a clean, healthy environment to live in as fresh air replaces the stale air
Dilute – Displace – Replace
Moisture & Condensation With PIV:
Moisture created in the bathroom from showering
Once you open the door the moisture looks to escape to the coldest part of the house
Drimaster Diffuser is positioned in the hallway purposely to mix with the stale air
Dirty moisture laden air is diluted by the clean fresh filtered air from the Drimaster
Air escapes through the natural gaps in the property
When Are Additional Extract Fans/measures are Needed?
When there is an internal wet area WITHOUT an openable window.
When the air flow from the diffuser has to pass through two doors to reach a wet area.
When PIV is suitable on its own:
Wet rooms directly off the hall (all with openable windows)
When is PIV not suitable on its own:
Continued…
Flatmaster: Typical Properties
Why is the FLATMASTER manufactured to the size it is?To fit above Kitchen cupboard space Normally around 350-400mm space above cupboard (FLATMASTER Height 320mm)
Nuaire’s PIV Range Of Products:
DRIMASTER• Unit capable of 60 l/s on normal
operation
• Boosts to 70 l/s in Heat Recovery Mode
• 6 speed settings 10-60 l/s in steps of 10 l/s (may vary on different setting)
• 5 in built control strategies that adjust the operating temperatures
• Built in hour run monitor as standard flashes in hours/ days/months to tell total run time
• 1 amp fuse supplied with the unit
• Running cost 1p per day
• 5 year filter supplied as standard
• Everything supplied to fit the unit
DRIMASTER 2000• Unit capable of 60 l/s on normal
operation
• Boosts to 70 l/s in Heat Recovery Mode
• 6 speed settings 10-60 l/s in steps of 10 l/s (may vary on different setting)
• 5 in built control strategies that adjust the operating temperatures
• Built in hour run monitor as standard flashes in hours/ days/months to tell total run time
• 1 amp fuse supplied with the unit
• T2 Sensor for additional heat recovery
• Running cost 1p per day
• G4 5 year filter supplied as standard
• G4 Filter – 5 Microns
• Everything supplied to fit the unit
DRIMASTER-HEAT• Supplied with 500W Heater
• Thermostat Heater control
• Unit capable of 60 l/s on normal operation
• Boosts to 70 l/s in Heat Recovery Mode
• 6 speed settings 10-60 l/s
• 5 in built control strategies that adjust the operating temperatures
• Built in hour run monitor as standard flashes in hours/ days/months to tell total run time
• 1 amp fuse supplied with the unit
• Running cost 0.10p per day
• G4 5 year filter supplied as standard
• Everything supplied to fit the unit
DRIMASTER-3S• All features as per the DRIMASTER
units however supplied with an aluminium diffuser as per below
• For use in 3 storey properties
• Unit must be linked to smoke alarm
• Aluminium Diffuser with fire block for Protected Stairwell
• Running cost 1p per day
• G4 5 year filter supplied as standard
• Everything supplied to fit the unit
FLATMASTER • Units can be ducted from side or the
back of the unit
• Unit capable of 45 l/s on normal operation
• 3 speed settings 15-30-45 l/s
• 3 amp fuse supplied with the unit
• Unit capable of taking 100mm diameter or 121x60mm flat duct with both sets of spigots supplied as standard
• Running cost 1 to 1.5p per day
• G3 2 year filter supplied as standard
FLATMASTER 2000• Heater can be handed left or right
• Units can be ducted from side or the back of the unit
• Supplied with an in built 300W Heater
• Thermostat Heater control built in
• Unit capable of 45 l/s on normal operation
• 3 speed settings 15-30-45 l/s
• In built manual boost switch on the unit for heater
• 3 amp fuse supplied with the unit
• Unit capable of taking 100mm diameter or 121x60mm flat duct with both sets of spigots supplied as standard
• Running cost per day 15p based on unit at 30 l/s, last 12 months average temperatures & target temp of 8 degrees c (13p electric cost per KW Hour)
• G3 2 year filter supplied as standard