Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing...

Date post: 04-Jun-2018
Category:
Upload: dangminh
View: 279 times
Download: 0 times
Share this document with a friend
20
www.NucorBuildingSystems.com
Transcript
Page 1: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

www.NucorBuildingSystems.com

Page 2: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof
Page 3: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Nucor Building Systems - The Brand of Choice

Nucor CFR™ System Foundation and Performance

Nucor Corporation is a Fortune 500 company, producing steel and steel products and is well known for its ability to manufacture high quality products at very competitive prices. These attributes apply equally to Nucor Building Systems (NBS). As a complete building systems manufacturing company, NBS is one of the most flexible and diverse manufacturers in operation today.

Our four full-service facilities are stragetically located in:Waterloo, Indiana -- Swansea, South Carolina -- Terrell, Texas -- Brigham City, Utah

The Nucor Building Systems CFR Standing Seam Roof System presents the building owner with a high quality, economical alternative to other roofing systems. The system is designed to meet the demanding needs of today’s building market. The foundation of the CFR system is based on the critical need for the roof to satisfy four basic principles:

Weathertightness .............................CFR is a weathertight system * Strength ............................................CFR is safe and satisfies code and uplift requirements Erector Friendliness ........................CFR is flexible and easy to install Cost Effectiveness ..........................CFR is an economical roofing solution

The Nucor CFR system is a functional roof specifically designed for low slopes. Our roof has been extensively tested to ensure the highest level of performance for weathertightness as well as structural integrity. The panels have been tested and approved by Factory Mutual® and Underwriters Laboratories® for wind uplift as well as hail and fire resistance. The flexible options offer a number of cost effective design solutions.

For more information, visit www.NucorBuildingSystems.com

*Refer to the CFR Weathertightness Warranty at www.nucorbuildingsystems.com/warranty for more specific performance criteria. Due to a process of continuous improvement, all information contained within this brochure is subject to change without notice.

Foundation of Performance ...................... 1Features and Benefits .............................. 2Application and Guidelines ....................... 3Clip & Insulation Options .......................... 4Specifications and Performance ............... 6Warranties ................................................ 8Details....................................................... 9

Nucor CFR ™ System

Page 4: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Nucor offers a hand-operated crimping tool for seaming, as well as a seaming machine to achieve the Nucor Vise Lock® installation option.

Non-Handed System Nucor CFR is designed to allow the installer to erect the roof in either direction, providing flexibility to choose the most efficient starting points on the roof. Additionally, in most cases the installer has the option to install either the roof or wall system first.

Flexible Seaming Options The roof can be completely installed without the use of electric seaming machines. An electric machine is available for use after roof installation when required due to high uplift conditions or specified criteria, but the seamer does not have to be run as the panels are installed. In all cases the roof is installed and hand crimped leaving the electric seaming to be accomplished safely and efficiently as one of the last steps of construction.

Wide Range of Insulation Options Nucor CFR is designed to work with a variety of insulation systems including fiberglass batt, rigid board, and rigid board with the use of a liner decking. This offers the builder and owner flexibility when choosing the best system to meet the functional needs of the building. It is recommended that some type of insulation be used with all CFR roof systems to prevent wind flutter or damage due to the effects of condensation.

Fasteners Outside the Building Envelope At the eave and ridge locations, fasteners are uniquely placed outside the building envelope, greatly reducing the chance for water penetration into the roof system.

Patented Panel Splice Detail Panel splices have been designed with a patented system to occur away from the purlin or joist so that normal tolerance found in construction will not hinder installation of the system. The continuous endlap design provides continuity as well as reduced handling of panels during installation.

Factory Dimpled and Notched Nucor CFR panels are factory dimpled and notched to aid the installer in providing a weathertight fit. Dimples indicate fastener placement at the end lap and aid against fastener “walking”.

Solid Seam Design Our seam profile is intentionally “stout” to provide flexibility in the field as well as a positive lock by the electric seamer, when the seamer is required.This all but eliminates the possibility of the seamer malfunctioning and damaging the seam as can occur with older “Pittsburgh-style” seams.

The Nucor CFR System is a raised seam metal roof which is designed to “float” to accommodate thermal expansion and contraction. This is accomplished with concealed sliding clips which allow for up to 3” of expansion and contraction. The panel sidelap has factory applied mastic and can be completely erected without the use of electric seaming machines.

Features and Benefits

2

Page 5: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Nucor ROLL LOCK™ SEAM

DiaphragmThe Nucor CFR system, because it is designed as a floating system, cannot be solely relied upon as a diaphragm for resisting lateral load forces or providing lateral stability to roof structural members.

Due consideration for this must be addressed by the project engineer of record or system designer when CFR is used in conjunction with other structural systems. When replacing an existing screwdown roof, additional bracing may be required to laterally support the members. Engineering and material for these uses shall not be provided by Nucor Building Systems.

Roof Top Units Roof top units and roof penetrations should be kept to a minimum and be clearly identified on the Nucor order documents including size, location, and weight. See the Nucor Product & Engineering Manual for specific information concerning framing and flashing options (available on-line at www.nucorbuildingsystems.com).

High-Performance FinishesThe standard finish for the Nucor CFR is Galvalume. A high-performance painted finish is also available. Consult your local Nucor Building Systems plant for specifics. Accessories, including gutter brackets, cinch straps, end dams, and rib covers are provided in an unpainted finish. If desired, accessories can be field painted to match the roof. Paint can typically be acquired locally, and is not provided by NBS.

Optional Warranty20 Year Weathertightness

More specific details as well as samples can be viewed in our Online Nucor Warranty Guide which is available at nucorbuildingsystems.com/warranty.

ROOF PANEL

PANEL CLIP

TOP OF PURLIN OR JOIST

ROOF PANEL

PANEL CLIP

ROOF PANEL

PANEL CLIP

1/2”

or 1

1/2 ”

Nucor VISE LOCK® SEAM Nucor VISE LOCK 360® SEAM

Hand Crimped at ClipsUL Rated

Mechanically SeamedUL RatedFM Approved

Mechanically SeamedUL RatedFM ApprovedEnhanced Uplift Capacity

Galvalume® is a registered trademark of BIEC International, Inc.; FM® is a registered trademark of Factory Mutual, Inc.; UL® is a registered trademark of Underwriters Laboratories, Inc.

CFR Warranties Available

Standard Warranties25 Year Galvalume® Finish25 Year Silicone Polyester Paint Finish 35 Year PVDF Paint Finish

Flexible Seaming Options

Warranties and Options

3

Page 6: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Nucor CFR Panel with Short Clip

Nucor Building Systems recommends that insulation be used in all CFR roof applications to avoid problems with condensation forming. Insulation also provides a buffer between the purlins and the CFR roof to reduce noise and possible damage due to metal to metal contact. Insulation requirements are as follows:

Short Clips: 2” to 4” of insulation compressed to 1/2” thickness over roof purlins. EPS foam spacers are available for limited use in non-insulated areas.

Tall Clips: 4” to 6” of insulation compressed to 3/4” thickness under thermal block at roof purlin locations. Thermal blocks are required when tall clips are used.

CLIP APPLICATIONS

Roof Structural Type Panel Run </ = 80’-0” Panel Run >/ = 80’-0”

Purlins Fixed Clip Floating Clip

Joists Floating Clip Floating Clip

Nucor CFR Panel with Tall Clip & Thermal Blocks

Insulation Requirements

Clip and Insulation Options

4

SHORT PANEL CLIPCLIP FASTENERS(2) REQ'D. PER CLIP

NUCOR CFR PANEL

1/2"

BATT INSULATION

ROOF PURLIN OR JOIST

BATT INSULATION

TALL PANEL CLIP

CLIP FASTENERS(2) REQ' D. PER CLIP

ROOF PURLIN OR JOIST

1-1/2"

THERMAL BLOCKS

NUCOR CFR PANEL

Page 7: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

- NBS recommends that either the rigid board or fiberglass insulation be installed in two layers, as shown above.

- This recommended layered method of insulation helps ensure that there are no gaps in the insulation, which can cause condensation problems. Insulation is not by Nucor.

- Roof deck is fabricated in accordance with SDI specifications and tolerances. Nucor does not offer warranties on liner decking.

- Panel clips fasteners must engage the Z-bar member. Self-drilling fasteners without a washer are utilized.

- A vapor barrier is required in all Composite CFR applications to avoid condensation. Vapor barrier not provided by Nucor.

- For UL90 requirements, please contact Nucor.

- Z-bars (16 gage min.) are spaced 4’-0” apart to accommodate Rigid Board Insulation widths, and 4-’0 or 5’-0” apart to accommodate Standard Fiberglass Insulation roll widths.

- NBS recommends that the rigid board insulation be installed in two layers, with the top layer being 1” thick, as shown on the left.

- This recommended layered method of insulation helps ensure that there are no gaps in the insulation, which can cause condensation problems. Insulation is not by Nucor.

- Roof deck is fabricated in accordance with SDI specifications and tolerances. Nucor does not offer warranties on liner decking.

- Panel clips fasteners must engage the roof secondary member. Self-drilling fasteners without a washer are utilized. Nucor recommends the deck and roof secondary member be pre-drilled for the panel clip fasteners to help avoid fastener drill point breakage.

- A vapor barrier is required in all Composite CFR applications to avoid condensation. Vapor barrier not provided by Nucor.

- For UL90 requirements, please contact Nucor.

Options for Composite CFR

Rigid Board Insulation w/Z-Bars

Rigid Board Insulation

Fiberglass Insulation w/Z-Bars

5

TOP LAYER OF RIGID BOARD INSULATION

SHORT SLIDING PANEL CLIP

Z-BAR (HEIGHT MATCHES BOTTOM LAYER INSULATION THICKNESS)

RECESSED BEARING PLATE

CFR PANEL

1.5B 22 GA. (MIN) ROOF DECK

2" MIN-4" MAX

1" (STANDARD)

BOTTOM LAYER OF RIGID BOARD INSULATION

CONTINUOUS VAPOR BARRIOR(NOT BY NUCOR)

DECK ATTACHMENT (FASTENER SHOWN, MAY BE WELDED)

SECONDARY MEMBER(PURLIN SHOWN, MAY BE JOIST)

TOP LAYER OF UNFACED FIBERGLASS INSULATION

TALL OR SHORT SLIDING PANEL CLIP

Z-BAR (HEIGHT MATCHES BOTTOM LAYER INSULATION THICKNESS)

THERMAL BLOCK (REQ'D WITH TALL CLIPS ONLY)

CFR PANEL

1.5B 22 GA. (MIN) ROOF DECK

3" MIN-6" MAX

2" MIN-6" MAX (WITH TALL CLIPS)2" MIN-4" MAX (WITH SHORT CLIPS)

BOTTOM LAYER OF UNFACED FIBERGLASS INSULATION

CONTINUOUS VAPOR BARRIOR(NOT BY NUCOR)

DECK ATTACHMENT (FASTENER SHOWN, MAY BE WELDED)

SECONDARY MEMBER(PURLIN SHOWN, MAY BE JOIST)

TOP LAYER OF RIGID BOARD INSULATION

SHORT SLIDING PANEL CLIP

RECESSED BEARING PLATE

CFR PANEL

0.6C, 1.5B OR 1.5F ROOF DECK

1" MIN-5 1/4" MAX FOR 0.6C DECK1" MIN-3 3/4" MAX FOR 1.5 DECK

1" (STANDARD)

BOTTOM LAYER OF RIGID BOARD INSULATION

CONTINUOUS VAPOR BARRIOR(NOT BY NUCOR)

DECK ATTACHMENT (FASTENER SHOWN, MAY BE WELDED)

SECONDARY MEMBER(PURLIN SHOWN, MAY BE JOIST)

EXTRA LONG PANEL CLIP FASTENERS

Page 8: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

• Standard 24” Width

• 3” Nominal Height

• Standard 24 Gage Galvalume - 50 ksi steel Siliconized Polyester and PVDF painted is available as an option

• Minimum Roof Slope: 1/4:12 Slopes greater than 4:12 may require special flashing details

• Custom Lengths 6’-0” to 55’-0”

• Designed for use with fiberglass batt or rigid board insulation

• Panels rated for UL90 and Factory Mutual uplift approval

• Standard roof line trim and flashing to be 26 gage

• Factory applied mastic in panel sidelap

Performance and Testing Summary

Classification Panel Gage Secondary Spacing Seam Option

Factory Mutual 1-60 24 Purlins or Joists 5’-0” Nucor Vise Lock®

Factory Mutual 1-90 24 Purlins or Joists 5’-0” Nucor Vise Lock®

UL90 - Listing #552 24 Purlins or Joists 5’-0” Nucor Roll Lock

ASTM & AISI TestingASTM E 1592 Uplift Testing

AISI Purlin Stability Base Testing

ASTM E 1680 Air Infiltration

ASTM E 1646 Water Infiltration

ASTM E 2140 Water Penetration

ASTM E 108 Flame Spread

Product Specifications

6

Page 9: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

• No through-fasteners - this is a fully adhered system

• UL90 approved without cumbersome reinforcing channels and framing

• Shipped preassembled for easy installation

• Endlap splices are dimpled for easy and proper installation

• Weathertight system

Technical Specifications

Property ASTM Standard Value

Tensile Strength D-638 25,772 psi

Tensile Modulus D-638 1.52 x 106 psi

Flexural Strength D-790 24,306 psi

Flexural Modulus D-790 .79 x 106 psi

Compressive Strength D-695 28,905 psi

Barcol Hardness D-2583 40 - 50

Uniform Building Code Class D-635 CC2

Smoke Developed Burning Rate

E-84 D-635

< 450< 2.5” / Min.

U Factor with Film Coefficients NFRC 102-2004 1.08 btu/hr ft 2 F

IMPORTANT!!! Never walk, step, or stand on a translucent panel. Injury or death could result.

Translucent Panel

7

Page 10: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

SAMPLE

25 Year Material Warranty

8

25 YEAR MATERIAL WARRANTY

FOR GALVALUME ROOF/SIDEWALL PANELS

Nucor Building Systems warrants to its Purchaser and to the original Owner that Nucor Building Systems Galvalume� Panels if used in the construction of a building erected within the United States, will not rupture, fail structurally, or perforate within a period of twenty-five (25) years after shipment from the Nucor Building Systems plant due to exposure to normal atmospheric conditions:

This warranty DOES NOT APPLY to panels exposed at any time to corrosive or aggressive atmospheric conditions, including but not limited to: 1. Areas subject to salt water (marine atmospheres) or to constant spraying of either salt or fresh water. 2. Areas subject to fallout or exposure to corrosive chemicals, fumes, ash, cement dust or animal waste. 3. Areas subject to water run-off from lead or copper flashings or areas in contact with lead or copper. 4. Conditions or circumstances where corrosive fumes or condensates are generated or released inside the building. 5. Areas where panels were not stored or installed per Nucor specifications.

This Warranty DOES NOT apply in the event of:A. Mechanical, chemical, or other damage sustained by the panels during shipment, storage, erection, or after erection. B. Failure to provide free drainage of water, including internal condensation, from overlaps and all other surfaces of the panels.C. Failure to remove debris from overlaps and all other surfaces of the panels. D. Damage caused to the metallic coating of the panels by improper scouring or cleaning procedures. E. Deterioration of the panels caused by contact with green or wet lumber. F. Presence of damp insulation or other corrosive materials in contact with or close proximity to the panels. G. Failure to use appropriate fasteners as specified in the Nucor Building Systems Erection Manual for all panel connections. H. Damage caused to metallic coating due to falling objects including hail and/or wind-borne debris. I. Failure of panels applied to slopes which are flatter than 1/4:12.

Additionally, insulation systems must be as defined in Nucor standard documents. Uninsulated areas are excluded from this warranty. Improper use of cutting blades or hot saws that expose the panels to debris shall void the warranty. Product life may be diminished by water runoff from existing structures, condensation unit runoff, or pipes and the like that introduce irritants to the panels.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

The foregoing warranty applies only to panels that remain in place at the site of the original construction and which have been stored and erected in strict accordance with all applicable Nucor Building Systems instructions and drawings. The foregoing warranty is extended solely to the original Purchaser and to the Original Owner of the building on which the panels are erected, and is not transferable or assignable. Labor for replacement panels shall be covered by the Purchaser.

In the event of the failure of the panels to conform to the foregoing warranty within twenty-five (25) years from the date of shipment of the panels from Nucor’s plant, Nucor must be notified in writing within thirty (30) days of discovery of such failure and given an adequate identification of the panels involved in the claim, including date of installation, invoice number and date of shipment. No corrective action shall be taken without Nucor Building Systems first having been afforded reasonable opportunity to examine the failure and to approve the method of corrective action taken. Failure to give such notice shall void this warranty.

PURCHASER’S OR ORIGINAL OWNER’S EXCLUSIVE REMEDY AGAINST NUCOR BUILDING SYSTEMS, AND NUCOR BUILDING SYSTEM’S SOLE OBLIGATION, FOR ANY AND ALL CLAIMS, WHETHER FOR BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE), OR OTHERWISE, SHALL BE LIMITED TO REPAIRING DEFECTIVE PANELS, OR AT NUCOR BUILDING SYSTEMS’ SOLE OPTION, TO FURNISH EXW LOADED NUCOR BUILDING SYSTEMS’ PLANT SUFFICIENT REPLACEMENT PANELS FOR THE DEFECTIVE PANELS.

Nucor Building Systems shall not in any event be liable for the cost of labor to replace any defective panels, nor shall Nucor Building Systems have any liability for incidental or consequential damages.

Nucor shall not have any obligation under any warranty or guarantee until all bills for material, installation and erection of said building and component thereof and labor and other work performed by the Purchaser have been paid in full by the Owner.

Builder has certified that Nucor panels were stored and installed in accordance with Nucor instructions. In the event Panels were not stored and installed in accordance with Nucor instructions, the Builder and/or those responsible for installation assume all liabilities to the Owner.

Preventative Maintenance Manual: Your building will occasionally need attention to maintain current aesthetic appeal, warranty coverage, weathertightness and proper working order of accessory items. Nucor Building Systems has made available a Preventative Maintenance Manual for you, the end owner. The purpose of the manual is to assist in your efforts in maintaining and protecting your new building. You can access and print the Preventative Maintenance Manual by going to our website (www.nucorbuildingsystems.com).

GALVALUME IS A TRADEMARK OF BIEC INTERNATIONAL

Rev. 03/12

R

R

Page 11: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

CFR Roof Details

REFER TO THE FOLLOWING PAGES FOR STANDARD DETAILS

DETAIL DESCRIPTION PAGE

CFRB060 Simple Eave 10

CFRB070 Eave Gutter 10

CFRB080 Sculptured Rake 11

CFRB090 High Eave 11

CFRB100 Standard Ridge 12

CFRB110 Optional Ridge 12

CFRB120 Rake Parapet 13

CFRB130 High Eave Parapet 13

CFRB140 Panel Splice 14

CFRB150 Roof Step Expansion Joint 14

CFRB160 Single Roof Curb 15

CFRB170 Double Roof Curb 15

9

CFRB080

CFRB100

CFRB150

CFRB130

CFRB090

CFRB120

CFRB070CFRB060

CFRB170CFRB110 CFRB160CFRB140

Page 12: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Simple Eave

Eave Gutter

CFRB060

CFRB070

1 1/2"

TAPE MASTIC

PRECUT TAPE MASTIC

EAVE PLATE

1/2" OR 1 1/2"

5 1/4"

3"

GUTTER HANGER

2" T

OP

OF

EAV

E

TAPE MASTIC

WALL PANEL

EAVE STRUT

GUTTER

TO

P O

F PA

NE

L

EAVE FLASH

INSULATION RETAINER

W/ PRECUT TAPE MASTICPANEL VOID CLOSURE

STEEL LINE

INSULATION(NOT BY NBS)

10

PANEL VOID CLOSURE H2630

8" PRECUT TAPE MASTIC H3640

1/2" OR 1 1/2"

WALL PANEL

5 1/4" T

OP

OF

EAVE

TO

P O

F PA

NEL

2"

12" O.C.

EAVE FLASHLEA01

H1060

1 1/2" TAPEMASTIC H3001

EAVE PLATE

EAVE STRUT

INSULATION RETAINERH2200 - 12" O.C.

H1020 6" O.C.

WITH (1) H1030 AND

3"

STEEL LINE

INSULATION(NOT BY NBS)

Page 13: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Sculptured Rake

High Eave

CFRB080

CFRB090

TAPE MASTIC

RA

KE

AN

GLE

BA

CK

OF

3 3/4"

1/2" OR 1 1/2"

START/FINISH PANEL

PURLIN

OUTSIDE PANEL CLOSURE

RAKE ANGLE

TOP

OF

PU

RLI

N

VARIES

TOP

OF

PAN

EL

WALL PANEL

RAKE TRIM

RAKE ANGLE

RAKE RETAINER

RAKE ANGLE CLIP

STEEL LINE

CFR ROOF PANEL

TAPE MASTIC

INSULATION (NOT BY NBS)

4"

HIGH EAVE FLASH

CFR ROOF

3"

1/2" OR 1 1/2"

PANEL CLIP

PURLIN

CAP TRIM

END DAM

2"TO

P O

F E

AVE

TOP

OF

PAN

EL

BACK-UP PLATE

1'-4"

WALL PANEL

TAPE MASTIC

RAKE TRIM RETAINER

EAVE STRUT

STEEL LINE

1 1/4"

END OF PANEL

TAPE MASTIC

INSULATION (BY OTHERS)

11

Page 14: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Standard Ridge

CFRB100

CFRB110

Optional Ridge

1'-4"

ROOF PANEL

3"

END DAM

1/2" OR 1 1/2"

SYMMETRICAL ABOUT

PANEL CLIP

5 1/4"

TAPE MASTIC

RIDGE CENTERLINERIDGE CAP

PURLIN

BACK-UP PLATE

TAPE MASTIC

INSULATION(NOT BY NBS)

PANEL CLIP END DAM

TAPE MASTIC

BACK-UP PLATE

TAPE MASTIC

ROOF PANEL

PURLIN

1/2" OR 1 1/2"

3"

RIDGE CENTERLINESYMMETRICAL ABOUT

RIDGE CAP5 1/4"

1'-4"

OPTIONALINSULATION PAN MK. IPA01

12

Page 15: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Rake Parapet

CFRB120

CFRB130

Do not fasten rake parapet trim to masonry wall

High Eave Parapet

1'-4"

TAPE MASTIC

PURLIN

3"

PANEL CLIP

TAPE MASTIC

1/2" OR 1 1/2"

CFR ROOF

BACK-UP PLATE

HIGH EAVE PARAPET

END DAM

COUNTERFLASH (NOT BY NUCOR)

MASONRY WALL

TAPE MASTIC

FASTENER TO MASONRYN.I.C. ( 12" O.C.)

5"

INSULATION (NOT BY NBS)

INSULATION ANGLE

13

TAPE MASTIC

RAKE PARAPET TRIM

TAPE MASTIC

COUNTER FLASH (NOT BY NUCOR)

MASONRY WALL

TAPE MASTIC

1/2" OR 1 1/2"

PURLIN

MK. H2051 (TALL)

RAKE ANGLE

3 3/4"INSIDE FACE OFMASONRY WALL RAKE ANGLE

EDGE OF

START/FINISH PANEL

RAKE ANGLE CLIP

3 7/

8"3

1/2"

FLAT

OF

"CFR

" RO

OF

TOP

OF

TRIM

LE

G

MK. H2041 (SHORT)

CFR ROOF PANEL

STEEL LINE AND OUTSIDE FACE OF MASONRY

INSULATION (NOT BY NBS)

Page 16: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Panel Splice

Roof Step Expansion Joint

CFRB140

CFRB150

See Page 16 for an exploded view of the endlap

** 41/2” if lower roof plane panel has tall clips; 51/2” if lower roof plane panel has short clips Dimensions do not apply to composite roof systems

1/2" OR 1 1/2"

(NOT BY NBS)

PANEL CLIP

3"

4"

1'-0"

8"

ROOF PANEL

INSULATION

UP SLOPE

PURLIN

TAPE MASTIC

ROOF PANEL

BACK-UP PLATE

PANEL VOID CLOSURE W/ PRECUT TAPE MASTIC

EAVE PLATE

1/2" OR 1 1/2"

3"

TAPE MASTIC

PANEL CLIP

TAPE MASTIC

3"

BACK-UP PLATEPURLIN

ROOF PANEL

ROOF STEP TRIM**

END DAM

TAPE MASTIC

TAPE MASTIC

INSULATION (NOT BY NBS)

14

Page 17: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Single Roof Curb

Double Roof Curb

CFRB160

CFRB170

For RTU’s less than 750# with sliding panel clips

For RTU’s > than 750# and < 1200# with sliding panel clips

BACKER CHANNEL SUPPLIED WITH CURB

TAPE MASTIC UNDER THE RIB COVER SUPPORT

FRAMING

BATT INSULATION (NOT BY NUCOR)

TAPE MASTIC UNDER THE CURB

1 1/2" CLEAR OPENING

INSULATION

ROOF CURB

1 1/2"

1/2" OR 1 1/2"

TAPE MASTIC PURLIN/JOIST

BATT INSULATION (NOT BY NUCOR)PANEL CLIP

ROOF PANEL

RIB COVER

TUBE CAULK

WATER DIVERTER

RIB COVER

TAPE MASTIC UNDER THE RIB COVER

BACKER CHANNEL SUPPLIED WITH CURB

TAPE MASTIC UNDER THE CURB

COLLAR FLASH SUPPLIED WITH CURB

FLOATING CURB

RIB COVERBATT INSULATION (NOT BY NUCOR)

RIB COVER

TUBE CAULK

BATT INSULATION (NOT BY NUCOR)

TAPE MASTIC UNDER THE RIB COVER

INSULATIONROOF PANELPANEL CLIP

STRUCTURAL CURB

3"

PURLIN/JOIST

SUPPORT FRAMING

TAPE MASTIC UNDER CURB

CURB INSULATION

1/2" OR 1 1/2"

WATER DIVERTER

WEATHER STRIPPING

3"1 1/2"1 1/2" ROOF OPENING3"

15

Page 18: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

Exploded Endlap

CFRB180

16

TAPE MASTIC

ROOF PANEL CLIP

BACK UP PLATE

LOW EAVE

UPPERROOF PANEL

BUTYL TUBE CAULK IN THE RIB AREA AS SHOWN. (FEMALE SHOWN, MALE SIMILAR)

FEMALE RIB

FEMALE RIB

MALE RIB

UPSLOPE ENDUSE FACTORY DIMPLES FOREND LAP FASTENER GUIDE

FASTENERS

Page 19: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof
Page 20: Nucor CFR Standing Seam Roof System - Nucor Building … · The Nucor Building Systems CFR Standing Seam Roof System presents the ... Nucor Vise Lock ... Nucor CFR Standing Seam Roof

www.NucorBuildingSystems.com

Nucor Building Systems has plants strategically located with full-service capacity to meet your needs. Our plants are located in Indiana, South Carolina, Texas and Utah

NBS10971

Indiana Plant Northeast Sales Office South Carolina Plant305 Industrial Parkway 201 Granite Drive P. O. Box 1006

Waterloo, IN 46793 Suite 280 200 Whetstone Rd.

Ph: 260.837.7891 Lancaster, PA 17601 Swansea, SC 29160