Number 1 in aggregates, number 2 in cement,and number 3 in ready-mixed concrete in World

Company Profile- HeidelbergCement India Ltd

HeidelbergCementItalcementiHeidelbergCement andItalcementi

63000 no. of employees3000 locations in more than

60 Countries

Page 3: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description
Page 4: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

MILESTONES OF JHANSI PLANT ..…

Major Equipment Capacity

Cement Mill-1 (Ball Mill) Capacity-105 TPHMake: KHD Humboldt

Cement Mill-2(VRM) Capacity-215 TPHMake: Loesche

Packer- 4 Nos. Capacity- 4* 240 TPHMake: EEL

Wagon Tippler Capacity: 1000 TPHMake: Metso

Expansion Byinstallation ofLoesche VRM

ModifiedDry fly ash

feedingsystem

Wagon Tippler Capacity: 1000 TPHMake: Metso

0.8 MTPA-19910.5MTPA 1989

Installed Capacity

1.0 MTPA-2010

2.7MTPA-2013

InstalledRollerPress

InstalledKHD Ball

Mill

ModifiedDry fly ash

feedingsystem

2006- HC Take Over

Page 5: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Integrated Management Policy

Excellent EnergyEfficient Unit

Award by CII-2016

Page 6: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

ROADMAP FOR CONTINOUS IMPROVEMENTROADMAP FOR CONTINOUS IMPROVEMENT

Page 7: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

CIP ENCON Organization StructureCIP ENCON Organization Structure

Plant HeadV.P.(Technical)

ENCON PROJETHEAD

HOD (E&I)

ENERGYMANAGER

Process In charge(Grinding & MH)

Team-4

Maintenance &Utility In charge

Team-9

Packing &Dispatch In charge

Team-4

ENCON PROJETHEAD

HOD (E&I)

ENERGYMANAGER

Page 8: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Daily EnergyMonitoring

Proposals for

ENCON

Review through

Concern Deptt.

Review byENCON CellFeasibility TestFast Track

Approval

Energy Monitoring Methodology For Evaluation of SavingEnergy Monitoring Methodology For Evaluation of Saving

CIP IDEA GENERATION PROCESS

Documentation&

Implementation

Review OfBenefits

AppreciationConcern Team

**Energy Conservation Cell meet once in a month for review of Energy ConservationProjects and their status.

IDEA IMPLEMENTATION PROCESS

Page 9: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Energy Performance ( Cement Grinding Unit)

SNo

Description Units 2014-15 2015-16

1 MTOE reduction MTOE 321.82 976.0264

2 Specific Electrical Energy – Grinding kWh/T of cement 31.86 29.74

3 Clinker factor % 60.56 61.77

4 Blended cement (*% of total cement) % 100 100

5 Specific CO2 emission Kg CO2/ kg cement 553.74 546.945 Specific CO2 emission Kg CO2/ kg cement 553.74 546.94

Page 10: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

SEC Break-up –VRM+BM

VRM+BM Specific Power Consumption Break Up Mill-wise

Section 2014-15 2015-16

Main Drive (VRM+BM) 16.75 15.91

Bag House Fan VRM 4.76 4.40Roller Press BM 0.49 0.49Mill Aux., Mill Dedusting, Silo Feed, mill feed, CementTransport (VRM+BM) 4.03 3.83Mill Aux., Mill Dedusting, Silo Feed, mill feed, CementTransport (VRM+BM) 4.03 3.83

VRM+BM Cement Grinding Power KWH/T 26.03 24.63

Raw Material Handling (VRM+BM) 2.01 1.88

VRM+BM Packing Plant 1.72 1.58

VRM+BM Power Upto packing KWH/T 29.76 28.09

VRM Utility + T&D Losses 1.76 1.42

VRM+BM Total Power KWH/T 31.52 29.51

Page 11: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Total Sp. Power Consumption - Kwh/T of Cement

6.4 %31.5229.51

Page 12: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

24.4521

Benchmark - Cement Grinding SEC -KWH/T-VRM & BM

24.95 23.75

Main Drive

Mill Aux.

Mill FanMain Drive

Mill Aux.RPGS

** Bench Mark data taken by CII Analysis Report

Page 13: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description
Page 14: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

SI.NO. Description Of Project

AnnualSaving in

Units

Total AnnualSaving ( Rs. In

Lakhs)

1 Diesel saving by process optimisation 246

2 Optimization of wagon tippler compressor 21500 1.6

3 Optimisation of Bag filter & rotary air lock – (de-dusting systemof Bag Filter) 100676 7.1

4 Optimisation of air slide blower - ( feeding to VRM silo feedelevator & fly ash feeding circuit) 100021 7.2

Saving from major ENCON ProjectsWithout/Marginal investment 2015-16 financial year

Optimisation of air slide blower - ( feeding to VRM silo feedelevator & fly ash feeding circuit)

5 Hardwired interlock of LT capacitor banks done with drivestarting sequence 388000 29.1

6 Power saving by Mill optimisation & new support ring of VRM 3001333 225.1

7 Installed flap gate in place of rotary airlock of Bag filters of silotop 15540 1.1

8 Stopped one Bag filter fan with RAL of VRM clinker hopper topby connecting venting line from other Bag filter 88320 6.3

TOTAL 3715390 523.5

Page 15: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

SI.No. Description Of Project

InvestmentAmount(In lacs)

Total AnnualSaving ( Rs. In

Lacs)

1 Installation of solar street lights in colony in place of 150 wattHPSV fittings 16.15 2.50

2 Installation of delta to star energy saver kit in compressor 1.00 0.90

3 Installation of refrigerated air dryer 10 16

4 Installation of High Efficiency Motor 3.00 1.50

Saving from ENCON ProjectsWith investment 2015-16 financial year

4 Installation of High Efficiency Motor 3.00 1.50

5 Installation of VFD drives 6.5 18.0

TOTAL 36.65 38.9

Page 16: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description
Page 17: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Innovative Projects- 1Modification in Support Ring of VRM

Innovation: Modification in support ring has been done to reduce Gapbetween roller & table support ring to accommodate the surface loss insinter cast tyre face. This helped to bridge the gap between dam ring andtyre & resulted in increase of grinding efficiency.

Figure 3: Support Ring welding

Page 18: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Innovative Projects- 1Benefits by Modification in Support Ring of VRM

Page 19: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

• Stopped the Hot air generator oncontinuous basis.

• HAG is being used for only 2-3 Hrsin starting of VRM.

• Reduced the water sprays.• Storage of inbound materials in

covered storage yard.

Innovation: Utilization of exit gases from Stack by forced Recirculation ofgases back to the VRM Inlet.

Innovative Projects- 2Reduction of fuel consumption in VRM

Figure 2: Gas Flow Circuit

• Stopped the Hot air generator oncontinuous basis.

• HAG is being used for only 2-3 Hrsin starting of VRM.

• Reduced the water sprays.• Storage of inbound materials in

covered storage yard.

Page 20: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Innovative Projects- 2Reduction of fuel consumption in VRM

Fuel Saving in VRM by Hot gas Optimization

Description UOMAs per

LoeschePG Test

AfterOptimization-March13 toDec13

AfterOptimization-Jan14 toDec14

Design 1st Step 2nd Step 3rd StepFEED RATE TPH 215 235 242 243FEED RATE TPH 215 235 242 243

Fuelconsumption perton of cement

Lit/ton 3.22 2.11 0.38 0.32

ProductionPeriod

Months

Jan- Feb13 March-Dec13 Jan-Dec14

Page 21: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Innovative Projects- 2Reduction of fuel consumption in VRMInnovation: Utilization of exit gases from Stack by forced Recirculation ofgases back to the VRM Inlet.

Saving: Rs. 847 Lacs in three years

Page 22: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Renewable Energy Project

Installation of 20 Solar Water HeatingSystem for Guest House and colony .Size of the solar water heating system is200 ltr & 100 ltr.Annual Energy Savings = 36000 KWh Total Investment : 4.08 Lakhs Annual Savings in : 3.0 Lakhs

Installation of Solar Light

60 Nos. of solar lights were installed inPlant as well as colony area for streetlighting purpose.

Annual Energy Savings = 32400 KWh Total Investment : 42 Lakhs Annual Savings : 2.5 Lakhs

Installation of Solar Geyser

Installation of 20 Solar Water HeatingSystem for Guest House and colony .Size of the solar water heating system is200 ltr & 100 ltr.Annual Energy Savings = 36000 KWh Total Investment : 4.08 Lakhs Annual Savings in : 3.0 Lakhs

60 Nos. of solar lights were installed inPlant as well as colony area for streetlighting purpose.

Annual Energy Savings = 32400 KWh Total Investment : 42 Lakhs Annual Savings : 2.5 Lakhs

Page 23: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Utilization of Renewable Energy

Uses of Renewable energy Use of Turbo Vent to Improve the Air

circulationEnergy Saving =5.23 Lakhs

Use of Day light in workshop areaEnergy Saving =11.30 Lakhs

Use of solar Energy for streetIllumination.Energy Saving=2.5 Lakhs

Use of Solar Water Geyser inPlant Colony and Guest House.Energy Saving=3.0 Lakhs

TOTAL SAVING: 22.03Lakhs

Uses of Renewable energy Use of Turbo Vent to Improve the Air

circulationEnergy Saving =5.23 Lakhs

Use of Day light in workshop areaEnergy Saving =11.30 Lakhs

Use of solar Energy for streetIllumination.Energy Saving=2.5 Lakhs

Use of Solar Water Geyser inPlant Colony and Guest House.Energy Saving=3.0 Lakhs

TOTAL SAVING: 22.03Lakhs

Page 24: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description
Page 25: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

GHG Inventorisation

Decrease in emission of CO2by reduction in clinker, diesel& Power consumptions.

Prohibition of LMV vehiclesinside plant area to decreaseCO2 emission.

19.79 19.64

18.81

18

19

20

2013 - 14 2014 - 15 2015 -16

Reduction in CO2 Emissionby reduction in Power Cons.

(CO2 Kg/Ton of cement)

Page 26: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

1. Optimization of VRM CompressorCurrent Condition:- 2 Compressors (132KW Each) were in use for VRM compressed air

requirement. One was running on Load for 24 Hrs. whereas another one was on load

for 2-3 Hrs.

Action plan:- Adjusted Sump air pressure to reduce the unloading power consumption. Use of Auto start mode of compressors were taken in line for operation. Air pressure interlocking has been done for the start up of 2nd

compressor in case of pressure drop less than 5 Kg/cm2.

Result During Trial:- Power Units (Before)– 6729KWH/Day, Power Units (After) –

4278KWH/Day Saving in Power Units – 2451/Day. Total Annual Saving – 808830 KWH @ Rs. 7.5 / KWH Net Saving in INR: 60 Lacs/Annum

Innovative Projects Under ImplementationInnovative Projects Under Implementation

Current Condition:- 2 Compressors (132KW Each) were in use for VRM compressed air

requirement. One was running on Load for 24 Hrs. whereas another one was on load

for 2-3 Hrs.

Action plan:- Adjusted Sump air pressure to reduce the unloading power consumption. Use of Auto start mode of compressors were taken in line for operation. Air pressure interlocking has been done for the start up of 2nd

compressor in case of pressure drop less than 5 Kg/cm2.

Result During Trial:- Power Units (Before)– 6729KWH/Day, Power Units (After) –

4278KWH/Day Saving in Power Units – 2451/Day. Total Annual Saving – 808830 KWH @ Rs. 7.5 / KWH Net Saving in INR: 60 Lacs/Annum

Page 27: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

2. Saving By Installation of VFD in 75 KW Motor of Dust Collector Fan.Current Condition:- Bag filter fan (75 kw) are running with DOL starter in 50 % damper open

condition always. Consumption of Unit when Motor run in DOL is approx. 42 U / Hr.

Action plan:- After installation of VFD, we have opened damper 100% and control flow

by reducing RPM of Motor. It is taking approx. 12 U / Hr power, which is less than 75% of previous

power load.

Result:- Power Units (Before)– 1008KWH/Day, Power Units ( After)– 288KWH

/Day Saving in Power Units – 720 KWH/Day. Total Annual Saving – 237600 KWH @ Rs. 7.5 / KWH Net Saving in INR: 18 Lacs Approx.

2. Saving By Installation of VFD in 75 KW Motor of Dust Collector Fan.Current Condition:- Bag filter fan (75 kw) are running with DOL starter in 50 % damper open

condition always. Consumption of Unit when Motor run in DOL is approx. 42 U / Hr.

Action plan:- After installation of VFD, we have opened damper 100% and control flow

by reducing RPM of Motor. It is taking approx. 12 U / Hr power, which is less than 75% of previous

power load.

Result:- Power Units (Before)– 1008KWH/Day, Power Units ( After)– 288KWH

/Day Saving in Power Units – 720 KWH/Day. Total Annual Saving – 237600 KWH @ Rs. 7.5 / KWH Net Saving in INR: 18 Lacs Approx.

Page 28: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

4. Removal of Bag House Fan inlet damper in VRM

5. Installation of high efficiency Separator in Ball Mill.

6. Installation of VFD in Bag filter fan motor.

7. Changing angle of Armour ring in VRM.

8. Minimize False Air Intake.8. Minimize False Air Intake.

9. Manage Equipment Ideal Running

10.Instalation of Smart Solar Panel for Day time Office Operation

11. Replacement of HPSV light by LED light .

Page 29: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Energy monitoring & Methodology used for quantificationDaily Power Report

Annual Plan & monitoringAnnual Plan & monitoring

Page 30: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description
Page 31: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

BEST PRACTICES

Use of turbo- Ventilator No Need of Electrical Energy . Zero Maintenance. Cost Effective.

Fan Less Water Cooling System Use of Natural Draft. Reduction In Maintenance Cost

Use Of Natural Light in Electrical WorkShop Avoid the Use of electricity during

day time. Energy Saving. Improve the Working Conditions.

10-Nos. Installed in Mech.Workshop Building

Use of turbo- Ventilator No Need of Electrical Energy . Zero Maintenance. Cost Effective.

Fan Less Water Cooling System Use of Natural Draft. Reduction In Maintenance Cost

Use Of Natural Light in Electrical WorkShop Avoid the Use of electricity during

day time. Energy Saving. Improve the Working Conditions.

10-Nos. Installed in Mech.Workshop Building

Fan Less water cooling

Page 32: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

BEST PRACTICES

Energy Saving Device for Light Maximum Use of Day Light . Reduce the wastage of Electricity . Lower Maintenance Cost.

Solar Street Light Installation of 60 no’s Solar lights. Utilization of Renewable Energy.

Unity Power Factor Power Factor benefits by UPPCL Reduction in Line Losses. Increase In Efficiency of Electrical

system

Energy Saving Device for Light Maximum Use of Day Light . Reduce the wastage of Electricity . Lower Maintenance Cost.

Solar Street Light Installation of 60 no’s Solar lights. Utilization of Renewable Energy.

Unity Power Factor Power Factor benefits by UPPCL Reduction in Line Losses. Increase In Efficiency of Electrical

system

Page 33: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

BEST PRACTICES

VFD application For ENCON Project Significant Reduction In Energy

Consumption . Highly Efficient. Used In Compressor ,Electric Motor

,Pumps etc.

Electronic Ballast Improvement in PF Energy Saving of 60-70% Increase the Lamp Life

Use of Energy Efficient Motor Energy Reduction From 15%-20%. Long Life. Less Pay Back Period.

VFD application For ENCON Project Significant Reduction In Energy

Consumption . Highly Efficient. Used In Compressor ,Electric Motor

,Pumps etc.

Electronic Ballast Improvement in PF Energy Saving of 60-70% Increase the Lamp Life

Use of Energy Efficient Motor Energy Reduction From 15%-20%. Long Life. Less Pay Back Period.

Page 34: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description
Page 35: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Distribution of Portable Solar Lamps to 800 Students & VillageTemple Illumination by solar lights

To Promote use of Solar Energy& Power Saving village templeilluminated by solar light HCIL arranged for portable solar

lamp to each 800 girl student ofKasturba Gandhi Balikavidyalaya to support their studynot being interrupted by power

Distribution BY IG JHANSI

Page 36: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Awards & Appreciation'sCII National Award for Energy Efficiency-2016

Page 37: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description
Page 38: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Next Focus Areas & Improvements

Replacement of HPSV lampthrough LED In Plant Lighting

Commitment TowardsGreen Development

Utilization of RenewableEnergy Source by more using

solar light

For Energy Conservation Adoptedsmart Office automation

equipment

Page 39: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Next Focus Areas & ImprovementsInstallation of Solar panels on Roof top

Page 40: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Thank you

for better building

Energy Conservation isour Foremost priority

Page 41: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Jhansi Unit, home for manybeautiful distinct species.

Some of the birds seen in thecampus are: Grey Hornbill

Black Drongo

Little Egret

White Throated Kingfisher

Oriental Magpie Robin

Golden Oriole

BIODIVERSITY

Jhansi Unit, home for manybeautiful distinct species.

Some of the birds seen in thecampus are: Grey Hornbill

Black Drongo

Little Egret

White Throated Kingfisher

Oriental Magpie Robin

Golden Oriole

Page 42: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

Jan Jagran Rally on World Environment Day (5th June)For Awareness on Energy Saving & Tree Plantation

600 members of HCIL familyhave participated in this rally.

This rally marched (2.5Kms) inJhansi city with a motive tocreate awareness for energyconservation and greenenvironment protection.

Page 43: Number 1 in aggregates, number 2 in cement,qcfihyderabad.com/cc2016/tech-presentations/Energy/HeidelbergCe… · ** Bench Mark data taken by CII Analysis Report. SI. NO. Description

WASH Program

A small initiative taken by HCILGroup to improve Water ,sanitation & Hygienic conditions. Various awareness programs

were organised not only insidethe Plant but also in villagesassociated with plant site.

A small initiative taken by HCILGroup to improve Water ,sanitation & Hygienic conditions. Various awareness programs

were organised not only insidethe Plant but also in villagesassociated with plant site.


Recommended