Datasheet Apptek OdaLog ®RTx Logger Specification Certificate Number 996QM8001 026 t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: [email protected] www.a1-cbiss.com The OdaLog is specifically designed for the Wastewater Industry, primarily for locating at or close to the source of Hydrogen Sulphide emissions. The OdaLog RTx uses an in-built GSM modem to transmit logged H2S data to a dedicated Internet server that is remotely accessible to end-users by using proprietary OdaStat-G software. Wireless transmission of H2S data from within sewer network - Odour & corrosion control based on recent data - Trending, graphing and reporting H2S data • Powered by internal long-life lithium batteries (greater than 12 months) - Allows for long term deployment • Easy-to-access H2S data through using proprietary OdaStat-G software - Global access to H2S data via wireless-to-web monitoring - Remote access to H2S data reduces travel cost Web-to-RTx configuration - Parameters easily changed via bidirectional communication Specially designed for harsh wastewater environments - Unique and proven robust design based on established OdaLog Technology Features and Benefits •Long life lithium battery lasts greater than 12 months, allowing for long term deployment • Operates at ranges of 0-200ppm or 0-1000ppm • Memory capacity stores up to 42000 data points • Datalogging at intervals as low as 15 seconds and transmitted at intervals as low as 30 minutes • Large LCD making it easy to read Application Wastewater treatment • Sewers and manholes • Perimiter monitoring How It Works The OdaLog RTx uses an in-built GSM modem totransmit logged H2S data to a dedicated Internet server that is remotely accessible to endusers by using proprietary OdaStat-G software
Transcript
Page 1: Odalog RTx Datasheet

Datasheet

ApptekOdaLog ®RTx Logger

Specification

Certificate Number 996QM8001026

t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: [email protected] www.a1-cbiss.com

The OdaLog is specifically designed for the Wastewater Industry, primarily for locating at or close to the source of Hydrogen Sulphide emissions. The OdaLog RTx uses an in-built GSM modem to transmit logged H2S data to a dedicated Internet server that is remotely accessible to end-users by using proprietary OdaStat-G software. Wireless transmission of H2S data from within sewer network- Odour & corrosion control based on recent data- Trending, graphing and reporting H2S data• Powered by internal long-life lithium batteries (greater than 12 months)- Allows for long term deployment• Easy-to-access H2S data through using proprietary OdaStat-G software- Global access to H2S data via wireless-to-web monitoring- Remote access to H2S data reduces travel cost• Web-to-RTx configuration- Parameters easily changed via bidirectional communication• Specially designed for harsh wastewater environments- Unique and proven robust design based on established OdaLog Technology

Features and Benefits•Long life lithium battery lasts greater than 12 months,allowing for long term deployment• Operates at ranges of 0-200ppm or 0-1000ppm• Memory capacity stores up to 42000 data points• Datalogging at intervals as low as 15 seconds and transmitted at intervals as low as 30 minutes• Large LCD making it easy to read

Application• Wastewater treatment• Sewers and manholes• Perimiter monitoring

How It WorksThe OdaLog RTx uses an in-built GSM modem totransmit logged H2S data to a dedicated Internet server that is remotely accessible to endusers by using proprietary OdaStat-G software

Page 2: Odalog RTx Datasheet

Datasheet

ApptekOdaLog ®RTx Logger

Specification

Certificate Number 996QM8001026

t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: [email protected] www.a1-cbiss.com

Instrument Temp Range - 20OC (-4OF) to 50OC (-122OF)Sensor Temp Range -10OC to +40OC (14OF to 104OF) Instrument Relative Humidity Range 15-90% (non-condensing)Ingress Protection IP66/68External Dimensions Diameter 76mm (3”) x height 260mm (10.24”) [without antenna]Instrument Weight 980g (34.5oz) [with default battery type fitted]Power Supply(s) Replaceable D-Size 3.6 V Lithium Batteries x 2 - Li-SCO12Battery Life/Run Time Greater than 12 months (*depending on signal strength and server transmission interval)Data Logging Capacity Up to 42,000 readings in total (local memory, unlimited server memory)Logging Interval Selectable from 1 second to 1 hourTransmission interval Selectable from 30min to 24hrData Logging Capacity > logging interval of 1min=29 daysDuration Example Capacity > logging interval of 5min=6+mthsCommunication Module Internal Quad-band modem [*GPS optional]Tri-Band Antenna Water-proof (IP68) - Signal capacity (850- 900/1800/1900MHz) External dimensions:99mm high

OdaStatG Software

OdaStat software takes gas data from the OdaLog instrument and in a few

simple steps creates vital information, providing the user with a clear under-standing of gas levels and patterns in

graphical and tabular form.

OdaLog L2 H2S Loggers - Standard SensorSL-H2S-50/W OdaLog Logger H2S 0-50ppmSL-H2S-200/W OdaLog Logger H2S 0-200ppmSL-H2S-1000/W OdaLog Logger H2S 0-1000ppmSL-H2S-2000/W OdaLog Logger H2S 0-2000ppmSL-TF-H2S-200/W OdaLog FibreOptical H2S 0-200ppmSL-TF-H2S-1000/W OdaLog Fibre Optical H2S 0-1000ppmOL50 OdaLog Logger H2S 0.00-2.00ppm OdaLog L2 H2S Loggers - Long Life SensorLL-H2S-0-200/W OdaLog Logger H2S 0-200ppmLL-H2S-0-1000/W OdaLog Logger H2S 0-1000ppmLLTF-H2S-200/W OdaLog FibreOptical H2S 0-200ppmLLTF-H2S-1000/W OdaLog Fibre Optical H2S 0-1000ppm OdaLog Logger - Other GasesSL-CL2-20/W OdaLog Logger HCN 0-30ppmSL-HCN-30/W OdaLog Logger CL2 0-20ppmSL-NO2-50/W OdaLog Logger NO2 0-50ppmSL-SO2-50/W OdaLog Logger SO2 0-50ppmSL-NO-100/W OdaLog Logger N0 0-100ppmSL-CO-1000/W OdaLog Logger C0 0-1000ppmSL-NH3-100/W OdaLog Logger NH3 0-100ppm25-0013/W Weather Shield (Low Range)

OdaLog 7000 Models sold include Charger and leather case OdaLog 7000/7000ir is supplied standard with: Calibration fitting and allen tool with magnetic base.

OdaLog 700025-7000-S02/W O2, LEL, CO,H2S (General Industry) 7000Ir/W O2,CH4 (NDIR) AND H2S c/w charger & leather case 25-7001-L05/W O2, CH4/CO2, CO, H2S (Dual Sensor) Mining (IR)

OdaLog Wireless RTxRTX-H2S-200/W H2S sensor 0-200ppm rangeRTX-H2S-1000/W H2S sensor 0-1000ppm range11-0085/W OdaStat-G Software Kit11-2001/W OdaLog Surface-Mount Antenna11-0069/W Optional GPS with antenna Kit OdaLog Logger Accessories11-0000/W Allen Key with Magnetic Base11-0001/W Calibration Adaptor Fitting22-0002/W Switch Cover (Clear) Pk 1011-0020/W L2 True IRDA Communication Link11-1000/W OdaStat E Software Kit (Software and IR Link) Only available for 0-200ppm & 0-1000ppm versions25-0356/W OdaTrak Adaptor Assembly12-0008/W Fibre Optic Cable 5 metres (other lengths available)