Date post: | 08-May-2015 |
Category: |
Technology |
Upload: | schneider-electric |
View: | 31,234 times |
Download: | 3 times |
Schneider Electric 1- Industry- Russell Hall – June 17, 2013
Oil and Gas Upstream Solutions
Russell Hall
Regional Sales Manager, Telemetry and Remote SCADA Solutions
Tweet Live!#SchneiderXE
Schneider Electric 2- Industry- Russell Hall – June 17, 2013
Xperience Efficiency 2013Dallas Texas June 18-20, 2013
Oil and Gas Upstream Solutions● Discussing ways to save money, increase efficiency and improve
competitiveness
Schneider Electric 3- Industry- Russell Hall – June 17, 2013
Wireless Instruments – Well Head
Schneider Electric 4- Industry- Russell Hall – June 17, 2013
• Self-contained, battery-powered, Class 1 Div 1 Accutech wireless sensors eliminate the need for wiring and trenching
• Operates in 900 MHz unlicensed band
• Pushbutton LCD interface on the sensor
• -40 to +85°C (-40 to +185°F)
• Base radio supports up to 100 field sensors
• 1500 ft (450 meters) typical with standard antenna
• Optional high gain antenna for extended range
• Long battery life
Base Radio, Class 1 Div 2
Accutech Wireless
Wireless Instruments
Schneider Electric 5- Industry- Russell Hall – June 17, 2013
Efficiency and Serious Cost Savings
• Zero Trenching to Well Head
• Labor Time Required Until Operational
• Engineering and Materials
• Less Damaged During Workover
• Add Up to Improving Cost of Ownership
Schneider Electric 6- Industry- Russell Hall – June 17, 2013
Wireless Real World Economics
When ALL true installed costs are included in a cost evaluation:TRUE Wireless is the lowest cost option.
Schneider Electric 7- Industry- Russell Hall – June 17, 2013
Accutech Field Units
Typical Applications
Tubing pressureCasing pressureCasing ventArrival sensorTank LevelTank interface levelFrac pond levelSeparator levelSeparator pressureSeparator temperatureTurbine metersIntrusion detectionPressure relief valveOn / Off control valvePushbutton ESD
Schneider Electric 8- Industry- Russell Hall – June 17, 2013
SCADAPackSmart RTU
Modbus Centric Smart RTUSCADAPack 300
Series, SCADAPack 32 & 4203
DNP3/IEC60870 Centric
Smart RTUsSCADAPack 300E
Series, SCADAPack ES
• Core database is Modbus with DNP3 level 2 wrapper layer. Also supports A-B DF1
• Programmed and configured using Telepace Studio, as well as IEC61131 and C/C++
• O&G focused apps including Realflo Gas Flow Computer and PadPro Well Optimisation (NA only)
• Core database is DNP3 Level 4 with Modbus wrapper layer. Also supports IEC 60870-101/103/104 and A-B DF1
• Configured using E-Series Configurator tool and programmed using IEC61131 ONLY.
• Supports DNP3 Secure Authentication & IEEE 1711 (AGA12)
SCADAPack – Smart RTUs
Schneider Electric 9- Industry- Russell Hall – June 17, 2013
SCADAPack DNP3 Centric – Value Proposition
Wide range of connectivityEthernet IP/Series, integration with long range radios, public networks and satellite systems
Versatile and Flexible controllers Cost-efficient maintenance
Secure and Reliable Operations
Enhanced security suiteIEEE1711 encryption & IEC62351 authenticationSupport of DNP3 level 4
Event logging of critical dataUp 20,000 events (40,000 in case of SP ES) can be logged in the controller’s memory and backfilled once communications is re-established
Un-solicited alarms
Report by exception
All saving bandwidth
Remote configurationRemote programming, configuration and diagnostics
Schneider Electric 10- Industry- Russell Hall – June 17, 2013
Lower I/O Board Providing easy accessfor wiring on both sidesof the controller
Metal enclosure for increased ruggedness
Conformal coated 32 bit CPU board providing I/O scan rate of 150 msec; up to 4 gas flow runs
Ethernet & 3 Serial communication ports, independently configured, supporting Modbus RTU/ASCI, Modbus TCP, DNP3 Level 2 & DNP3 over IP protocols
USB local programmingport
External I/O modules can be added to the controller for easy expansion
Routing capabilities between all communication ports
Extensive data logging with time stamps for all data points in the controller’s memory
Military grade electroniccomponents supporting widetemperature range
Extended data logging using Flash drive (2Gb)
SCADAPack 300 range – Key Features
Schneider Electric 11- Industry- Russell Hall – June 17, 2013
• 4203 combines Gas Flow Computer and integrated Modbus Multivariable Transmitter in one device
• Built-in high performance SCADAPack 32-bit controller
• Integrated DP/P/T measurement with 0.05% accuracy, 15 bit A/D resolution
• Orifice, V-cone, wafer-cone and linear type meters
• Up to 2 flow runs
• API21.1 custody transfer compliant audit trail
• Two Modbus RS-232/RS-485 up to 115Kbps
• DR model: One 0-20mA AO, one turbine meter and one Counter Input/DI/DO (shared)
• DS model: Two 0-5V AI, one turbine meter/DO (shared) and one Counter Input/DI/DO (shared)
• Ultra low power consumption for solar applications (300mW)
• Hazardous locations: cCSAus Class 1 Div 1 (similar ATEX and IECEx ratings)
SCADAPack 4203 – Key Features
Schneider Electric 12- Industry- Russell Hall – June 17, 2013
SCADAPack50 Coming in September 2013
SCADAPack50: Baseline offer
• Binary data files over GSM through SMS messages
• Battery-powered, 5+ years
• IP68 packaging
4 analog Inputs:- Sensor interface- 0-100mV, 0-1V- 0-20mA, 4-20mA
4 digital Inputs:- Discreet input monitoring- Pulse counting (meters)
1 RS485 Modbus port:- Modbus instruments or RTU
Flexible input options
Direct support in StruxureWare SCADA Expert ClearSCADA
OPC gateway for use with any host platform or SCADA.
GSM Modem
SP50
GSM2G or 3G
Schneider Electric 13- Industry- Russell Hall – June 17, 2013
Ready-to-installRod Pump Controller
Help me to eliminate…
• Rod parting• Fluid pound• Gas lock
… and Optimize
• Production• Energy usage• Tank Management
Schneider Electric 14- Industry- Russell Hall – June 17, 2013
We’ve got your solution!
Complete and ready to go…
• Variable speed motor drive with RPC application
• Torque only, timed, surface card & downhole
• Web-based configuration interface
• Ethernet Modbus communications
• Load cell and proximity sensor
• Ready-to-install NEMA cabinet
Schneider Electric 15- Industry- Russell Hall – June 17, 2013
How does this benefit YOU?
Flexibility – an integrated solution that reduces cost of deployment
Complete Offer – one stop shopping!
• Field sensors• Well head monitoring & Control• Field communication infrastructure• Oilfield power / electrification systems• Downhole pump control / variable speed drives / pump protection relays• Well site security • SCADA Host systems
Schneider Electric 16- Industry- Russell Hall – June 17, 2013
Trio Offer – Product Selection
Licensed UHF
Industrial Spread
Spectrum
Serial InterfaceEthernet & Serial Interfaces
J-Series
M-Series
K-Series
E-Series
• Licensed and license-free long reach Data Radios• Offering multiple connectivity and design options• Implementing smart radio technologies for optimal
network performance
Schneider Electric 17- Industry- Russell Hall – June 17, 2013
Trio Offer – Key Points• Licensed and license- free bands
• Ethernet & serial connectivity
• Point-to-Point and Multi-Point networks
• Simultaneous multiple applications/protocols on one radio system
• Network wide diagnostics from anywhere in the system including any remote radio
• ClearSCADA integration of remote diagnostics
• Remote over-the-air configuration of any radio from any location
Schneider Electric 18- Industry- Russell Hall – June 17, 2013
MultiStreamTM
Remote Radio Sites
Secondary ApplicationSite
Remote Radio withSecondary Application
MODBUSHost
Creates virtual serial channels on same radio network by routing packets to ensure protocols are not mixed on same system.
DNPHost
Licensed Trio
License-free Trio
Schneider Electric 19- Industry- Russell Hall – June 17, 2013
SmartPathTM
Master orAccess Point
Alternative
Preferred
• Enhances radio link reliability by providing mesh type connectivity between sites.
• Offers higher bandwidth and lower latency than traditional mesh network implementations as network only reconfigures when path problem occurs
License-free Trio
Schneider Electric 20- Industry- Russell Hall – June 17, 2013
Schneider Electric 21- Industry- Russell Hall – June 17, 2013
Integrated SCADA Platform
Schneider Electric 22- Industry- Russell Hall – June 17, 2013
• Create templates for duplicate assets and devices to ensures standardization, to support rapid development and lower TCO
Templates
Schneider Electric 23- Industry- Russell Hall – June 17, 2013
Reliability (through redundancy)
DualWANs
Primary / Standby Pair
Dual LAN
AlternativeChannels
ViewXHMI
ViewX HMI
Disaster Recovery Site
TripleServer
Primary Control Center
Privileged & Confidential 23
Schneider Electric 24- Industry- Russell Hall – June 17, 2013
ANY QUESTIONS?
Thank You For Attending!