RSA Oil Fired, Chimney Vented, Steel Water Boiler 86% AFUE Steel heat exchanger, vertical firetube design Two sizes, 0.75 & 1.10 GPH Advanced base and shell design provides high level of heat transfer Turbulators provide maximum heat extraction and are removable for easy cleaning Simple quick release canopy on the top of the boiler provides easy access for servicing Tankless coil available, flange-mounted on front of boiler for easy access Lifetime limited warranty Available in select markets Primary Ignition Controls • Advanced status indicators and diagnostics – Beckett GeniSys™ HydroStat ® 3250 Three Function Hydronic Control • Easy temperature control Low water cut off – selectable auto or manual reset Fuel savings with thermal targeting or traditional outdoor reset capability Thermal pre-purge circulation uses latent heat before starting new heat cycle • Easy settings and monitoring • Primary circulator control function LED active status indicators assist contractors and consumers – High temperature, LWCO, economy operation • Dynamic digital display – Displays boiler supply temperature and outdoor temperature (if ODR installed) – Automatically displays set points during adjustments Intelligent Controls Simplify Installation and Operation
Transcript
Page 1: Oil Fired, Chimney Vented, Steel Water Boiler

RSA™

Oil Fired, Chimney Vented,Steel Water Boiler• 86% AFUE

• Steel heat exchanger, vertical firetube design

• Two sizes, 0.75 & 1.10 GPH

• Advanced base and shell design provides high level of heat transfer

• Turbulators provide maximum heat extraction and are removable for easy cleaning

• Simple quick release canopy on the top of the boiler provides easy access for servicing

• Tankless coil available, flange-mounted on front of boiler for easy access

• Lifetime limited warranty

• Available in select markets

Primary Ignition Controls• Advanced status indicators and diagnostics – Beckett GeniSys™

HydroStat® 3250 Three Function Hydronic Control• Easy temperature control

• Low water cut off – selectable auto or manual reset

• Fuel savings with thermal targeting or traditional outdoor reset capability

• Thermal pre-purge circulation uses latent heat before starting new heat cycle

• Easy settings and monitoring

• Primary circulator control function

• LED active status indicators assist contractors and consumers

– High temperature, LWCO, economy operation

• Dynamic digital display – Displays boiler supply temperature and outdoor

temperature (if ODR installed) – Automatically displays set points during

adjustments

Intelligent Controls Simplify Installation and Operation

Page 2: Oil Fired, Chimney Vented, Steel Water Boiler

© 2020 U.S. Boiler Company, Inc. - Lancaster, PAPhone: 1-888-432-8887

Printed in the U.S.A.USBL13027-5ms www.usboiler.net

RSA: Technical InformationStandard Equipment• ASME code boiler• Deluxe insulated jacket• Pressure/temperature gauge• ASME code boiler• Lightweight combustion chamber• Beckett AFG™ oil burner with flange• Beckett Genisys™ oil burner control• Hydrostat® 3250 hydronic control• Taco® circulator• Quick release canopy• Relief valve, 30 PSI

ASM

E

H

Model No.

Burner Capacity DOE Heating Capacity (MBH)2

AHRI Net Ratings(MBH)3 AFUE %GPH MBH1

RSAH111E 0.75 110 95 84 86.2

RSAH154E 1.10 154 134 117 86.0

RSA Ratings

Maximum design working pressure: 30 psi water only1. MBH refers to thousands of BTUs per hour2. Based on Standard Test prescribed by the United States Department of Energy at combustion conditions of 13.0% CO23. Net AHRI ratings shown are based on a piping and pickup allowance of 1.15

Dimensions & Specifications

ModelA

(In.)

Flue Collar (In.)

Tankless Heater GPM*

Minimum Chimney Requirements Approx.ShippingWeight(lbs.)

Round Diameter

(in.)Rectangle(in. x in.)

Height(ft.)

RSAH111E 34-9/16 6 3 6 8 x 8 15 300

RSAH154E 41 6 3-1/2 6 8 x 8 15 355

17"

TOP

1-1/4” MPTSupply Connection

3/4” MPTSafety Relief Valve Connection

1-1/4” FPTDrain Valve Connection

TanklessHeater(3/4” FPTconnections)

Temp/PressureGauge

1-1/4” FPTReturn Connection

ObservationPort

Optional Floor Shield(combustible flooring)

3-3/4"

7-1/4"

16-3/4"

A

17-1/2"

CEILING

16-3/16” MinimumClearance

16-1/2"

8-15/16"Smoke Outlet6” Diameter

BoilerControl

Oil Burnerw/PrimaryControl

FRONT

FLOORLINE

3"

SIDE11” Max22-15/16”

NOTES:1. Circulator supplied loose – may be installed on supply (recommended) or return (acceptable alternative) piping2. Return fittings and drain valve shipped loose

* Tankless heater ratings based on GAL/MIN of 100oF rise and with 200oF boiler water temperature and a 40oF heater inlet temperature (Intermittent Draw)


Recommended