    GSM Switching Subsystem

    SSS SR13.0/UCR5.0cs

    OMN:TE-AD

    A30828-Y1160-U3-1-7620

  • 8/13/2019 Omn Te Ad Mobile

    2/46

  • 8/13/2019 Omn Te Ad Mobile

    3/46

    A30828-Y1160-U3-1-7620

    3

    OMN:TE-AD

    Id:0900d8058018c604

    Table of ContentsThis document has 46 pages.

    1 Introduction (IN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    1.2 Test Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    1.2.1 Assignment of Test Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    1.2.2 Operating States of the Exchange. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    1.2.3 Test Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    1.2.4 Test Equipment Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    1.2.5 Test Points for Test Traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    1.2.6 Thresholds for ATE and TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    1.2.7 Test Schedules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    1.2.8 Test Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    1.2.9 Workstations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    1.2.10 Workstation Test Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    1.2.11 Workstation Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    1.3 Administration of Test Objects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    1.3.1 Subscriber Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    1.3.2 Administration of Thresholds for Line Testing . . . . . . . . . . . . . . . . . . . . 17

    1.3.3 Test Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    1.3.4 Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    1.3.5 Trunk Group Test Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    1.4 Line Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    1.4.1 Testing with the Line Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181.4.2 Tests with the ATE:T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    1.4.3 Automatic Tests with the TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    1.4.4 Tests with the Ringback Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    1.4.5 ISDN Line Tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    1.4.6 SULIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    1.5 Trunk Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    1.5.1 Testing with the Trunk Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    1.5.2 Tests with the ATE:T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    1.5.3 Tests with the ATE:TM / ATE:N/ ATCO. . . . . . . . . . . . . . . . . . . . . . . . . 20

    1.5.4 Tests with the Testset (Test Phone) . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    1.6 Safeguarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    2 Tasklist (TL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    2.1 Test Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    2.1.1 Operating states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    2.1.2 Display operating states of test equipment . . . . . . . . . . . . . . . . . . . . . . 22

    2.1.3 Test equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    2.1.4 Test equipment data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    2.1.5 Thresholds for ATE/TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    2.1.6 Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    2.1.7 Workstation group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    2.1.8 Workstation test port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

  • 8/13/2019 Omn Te Ad Mobile

    4/46

    4 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d8058018c604

    2.1.9 Test schedules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    2.1.10 Test jobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    2.1.11 Test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    2.2 Administration of Test Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.2.1 Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    2.2.2 Administration of thresholds for line testing . . . . . . . . . . . . . . . . . . . . . . 25

    2.2.3 Test classes for subscriber lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    2.2.4 Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    2.2.5 Trunk data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    2.2.6 Trunk group test data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    2.2.7 Administration of thresholds for international trunk testing . . . . . . . . . . . 25

    3 Procedures (TP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    4 TP-002 - Create testset at DLU port . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    5 TP-003 - Cancel testset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    6 TP-004 - Create ringback service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    7 TP-011 - Create SMC as TLWS workstation connected via NetM . . . . . 32

    8 TP-012 - Create OMT as TLWS workstation . . . . . . . . . . . . . . . . . . . . . 34

    9 TP-015 - Cancel workstation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    10 TP-016 - Modify worktstation data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    11 TP-017 - Modify workstation group data. . . . . . . . . . . . . . . . . . . . . . . . . 39

    12 TP-018 - Cancel workstation group . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

    13 TP-019 - Cancel workstation test port. . . . . . . . . . . . . . . . . . . . . . . . . . . 42

    14 TP-021 - Display intermediate test results . . . . . . . . . . . . . . . . . . . . . . . 43

    15 TP-022 - Display test job. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

    16 TP-030 - Display test results from archive fi le . . . . . . . . . . . . . . . . . . . . 45

  • 8/13/2019 Omn Te Ad Mobile

    5/46

    A30828-Y1160-U3-1-7620

    5

    OMN:TE-AD

    Id:0900d8058018c604

    List of FiguresFigure 1 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

  • 8/13/2019 Omn Te Ad Mobile

    6/46

  • 8/13/2019 Omn Te Ad Mobile

    7/46

    A30828-Y1160-U3-1-7620

    7

    OMN:TE-AD Introduction (IN)

    Id:0900d805800a677b

    1 Introduction (IN)

    gDepending on the scope of your project, this manual may contain more information-

    than you require.

  • 8/13/2019 Omn Te Ad Mobile

    8/46

    8 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a677b

    Introduction (IN)

    1.1 Interfaces

    Figure 1 Interfaces

    EXIT

    U M N : T E

    ENTRY:

    EXIT:

    (from cross-refer-

    ence) AD

    Administration

    SUB

    Subscribers

    TRK

    Trunks

    MaintenanceIntroduction

    INFC:SUB, INFC:TRK

    Task List for Maintenance

    TLFC:SUB, TLFC:TRKMMN:TESUBTLFC

    MMN:TETRKTLFC

    Output masks

    TEST RESULTS

    Fault clearance pro

    cedure no: FCxx

    Fault Clearance Procedures FCxx

    Tables TABxx

    MMN:xxx

    (continuation after

    cross-reference)

    Nonst. maintenance

    OA&M center

    (from test order)

    Test Procedures

    TPxxx

    Administration and OperationIntroduction

    IN:AD, IN:SUB, IN:TRK

    Task List for Operation

    TL:AD, TL:SUB, TL:TRK

    Tables

    TABxx

  • 8/13/2019 Omn Te Ad Mobile

    9/46

    A30828-Y1160-U3-1-7620

    9

    OMN:TE-AD Introduction (IN)

    Id:0900d805800a677b

    Key to interface diagram

    MMN:xxx: Fault clearance procedures MMN:LTGx or MMN:DLU

    OA&M: center Operation administration and maintenance center

    Figure 1shows an overview of the UMN:TE interfaces. It contains the links to other

    manuals. In addition to this, the overview shows where you can find task lists or fault

    clearance procedures to match output masks or test results..

    This manual is used in the system for the administration of tests and test objects.

    1.2 Test Administration

    1.2.1 Assignment of Test Commands

    Table 1shows how test objects are assigned to test commands.

    Test object Hardwar

    e

    Test

    equip-

    ment

    Test command

    Special circuit (ATE:T, TOG,

    RESP)

    LTG ATE:T TEST CTYPE, TEST LIC,

    TEST LTGPOS

    Special circuit (ATE:TM /

    ATE:N /ATCO)

    LTG ATE:TM

    ATE:N

    ATCO

    TEST CTYPE

    Analog subscriber line circuit DLU TU /DLUG

    TEST SLC, TEST DLULC

    Special circuit (TU) DLU TU TEST DLULC

    Analog PBXline, trunk-

    scriber

    LTGB/C ATE:T TEST PBXLN

    Analog PBX line DLU ATE:T TEST PBXLN

    Routine test of analog sub-

    scriber line

    DLU TU /

    DLUG

    TEST SUB

    Routine test of BA DLU TU /

    DLUG

    TEST SUB, TEST ISUB

    ISDNmeasurements DLU START RDSMEAS,

    ACT BAPERF

    Manual test of subscriber line

    and terminal connected to

    SLMA

    DLU TU /

    DLUG,

    LWS

    ACT WST, START LTEST,

    TEST LINE

    Manual test of subscriber line

    and terminal connected to

    BA

    DLU TU /

    DLUG,

    LWS

    ACT WST, START LTEST,

    TEST LINE

    Table 1 Assignment of test commands

    http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    10/46

  • 8/13/2019 Omn Te Ad Mobile

    11/46

    A30828-Y1160-U3-1-7620

    11

    OMN:TE-AD Introduction (IN)

    Id:0900d805800a677b

    TEST SUB

    digital TEST

    ISUB

    ACT ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    - NOTST

    SUL

    ACT -

    TEST LOOPBA ACT ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    ADMIN/

    1/2/3

    ACCSU

    SP

    NOTST

    SUL _

    -

    TEST PA - - MBL ACT

    CBL

    - - - - -

    Running digital

    sum measure-

    ment

    ACT ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    ADMIN/

    1/2/3

    ACCSU

    SP

    _

    -

    BA perfor-

    mance mea-

    surement

    ACT ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    ADMIN/

    1/2/3

    ACCSU

    SP

    - - -

    BLOCKING refers to ADMIN /ADMIN1, 2, 3, account suspension and trunk state

    BMNT

    LNATT refers to NOTSTSUL

    NO Testing not possible in any of the listed states

    ATE refers to ATE not blocked / CBL / MBL

    Port Mod

    ule

    DIU LTG DLU BLOCK

    ING

    LNATT TU

    mod

    ule/

    port

    ATE ATE

    :TM

    ATE

    :N

    AT

    CO

    RBS

    analog

    DLU

    ACT ACT - ACT ACT ADMIN/

    1/2/3

    ACCSU

    SP

    NO ACT - -

    Table 3 Operating states that permit testing, 2

    Port Mod

    ule

    DIU LTG DLU BLOCK

    ING

    LNATT TU

    mod

    ule/

    port

    ATE

    Table 2 Operating states that permit testing, 1 (Cont.)

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    12/46

    12 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a677b

    Introduction (IN)

    1.2.3 Test Equipment

    The different types of test equipment are used to test trunks, lines, line circuits, PBX

    lines, terminals, tone generators, announcements and for self-testing of the test equip-

    ment itself.

    The following types of test equipment can be created with command CR TEQ

    RBS

    digital

    ACT ACT - ACT ACT ADMIN/

    1/2/3

    ACCSU

    SP

    NOTST

    SUL

    - - -

    LWS

    analog

    DLU

    ACT ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    ADMIN/

    1/2/3

    ACCSUSP

    NO ACT - -

    LWS

    digital

    ACT ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    ADMIN/

    1/2/3

    ACCSU

    SP

    NO ACT - -

    TWS ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    - BMNT

    ADMIN

    - - - ACT

    TEST

    TRUNK

    ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    - BMNT - - ACT -

    TEST

    INTLTRK

    ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    - BMNT - - - ACT

    ACT

    BERM

    ACT

    CBL

    - ACT

    CBL

    ACT

    CBL

    - BMNT - - - ACT

    BLOCKING refers to ADMIN /ADMIN1, 2, 3, account suspension and trunk state

    BMNT

    LNATT refers to NOTSTSUL

    NO Testing not possible in any of the listed states

    ATE refers to ATE not blocked / CBL / MBL

    Port Mod

    ule

    DIU LTG DLU BLOCK

    ING

    LNATT TU

    mod

    ule/

    port

    ATE ATE

    :TM

    ATE

    :N

    AT

    CO

    Table 3 Operating states that permit testing, 2 (Cont.)

    http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    13/46

  • 8/13/2019 Omn Te Ad Mobile

    14/46

    14 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a677b

    Introduction (IN)

    Table Table 5shows the correlation between test equipment type, circuit type and LTU

    type for test equipment connected to DLU.

    1.2.4 Test Equipment Data

    Additional data can be assigned to test equipment with command ENTR TEQDAT.

    Parameter LAC must be specified whenever it is possible that subscriber directory

    numbers without local area code or traffic discrimination code could arrive via the testequipment.

    The value entered for parameter DLU defines which range of DLU the interfaces

    MAOGT and MANTT are responsible for.

    The value for the unlocking number UNLNO used by the responder TEMLE, DIGLP,

    TESTSET and ETEAE is entered with command CR TEQ.. It can be modified with

    command MOD TEQ.

    1.2.5 Test Points for Test Traffic

    Test equipment types TEMLE, TLFB, RBSI, WSTGRP and ETEAE are accessed

    through the digit translator by means of test points rather than by means of code points.

    ATEBRESP ATETM ATM

    ATESELF ATETM ATM

    CE TECONF V08, V10, V22, V23,

    V31

    DIGLP DIGLPBKT V04, V05

    ETEAE ETEAE E02, F02, F03, N05,

    V04

    MACL CTEIC, CTEOG C07

    RBSI RBS V09, V22, V31, V32

    TEMLE TEMLEPRT, TETRR2, TETRL,TETRWL C03, C06, N07, N08,

    V05

    TLFB TLFBIC V03, V23

    TLFI TLFIC, TLFOG V09, V22, V31, V32

    Test equipment

    at DLU port

    Circuit type in DISP DLUPORT LTU type in DISP LTU

    MANTT MTAC D30

    MAOGT MTAC D30

    MACONN MTAC D30

    TESTSET SLCA D30

    Table 5 Permitted circuit types and LTU types (DLU)

    Table 4 Permitted circuit types and LTU types (LTG) (Cont.)

    http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    15/46

    A30828-Y1160-U3-1-7620

    15

    OMN:TE-AD Introduction (IN)

    Id:0900d805800a677b

    Directory numbers are assigned to these types of test equipment with the command CR

    TEPT.

    For each directory number, a destination (command CR DEST) and a route (command

    CR ROUTE) and a zone point (command CR ZOPT)must be created.

    1.2.6 Thresholds for ATE and TU

    The number of times that an automatic test will be repeated if a fault is found can be

    interrogated with command DISP THR; (output parameter: TEREP). The default value

    is 2, and it can be modified with ENTR THR:THRESH=TEREP, VALUE=.

    If the ATEor TUreports a fault in a test object several times in succession, the self-test

    is started automatically. The threshold at which the self-test is triggered can be defined

    by the system operator and displayed with DISP THR; (output parameter FAILATE). The

    default value is 10, and it can be modified with ENTR THR:

    THRESH=FAILATE, VALUE=;.

    1.2.7 Test Schedules

    Schedules can be assigned to automatic test commands with parameter SCHED. The

    schedules can be created with command ENTR TSTSCHEDand can be shared by

    several test jobs. The schedules can be deleted with DEL TSTSCHED.

    1.2.8 Test Results

    The results of an automatic test job without schedule are output at the end of the test.

    Intermediate results (not for a single test) during the test process are only output onrequest, using command DISP TSTRES.

    The results of automatic test jobs with schedule are written to a cyclic history file or

    archive file. This file is large enough to store the test results accumulated over one week

    The commands DISP AENTRYand SEL AENTRYare used to read out the test results

    from the archive file.

    1.2.9 Workstations

    Command CR WSTis used to create a workstation for the manual testing of trunks and

    lines.

    A workstation can be connected to the system at an LTGof type LTGB: Only one workstation can be connected in the exchange as PT0X. Its name is

    specified in the 1st information unit of parameter TERMID. No other information

    units may be entered for parameter TERMID.

    If a workstation is connected via SMC, both information units of parameter TERMID

    (processor and terminal number) must be entered.

    The processor name must be created in the system (DISP PRO/CR PRO), other-

    wise the command will be rejected.

    Parameter WSTSN is used to assign a directory number to the workstation for use

    in tests. An additional directory number can be assigned to the workstation for a

    service handset with parameter DN. Both directory numbers must be pre-engi-

    neered in the exchange and belong to the same local area (LAC).

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    16/46

    16 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a677b

    Introduction (IN)

    An originating mark can be specified with parameter ORIG1.

    The command will be rejected if

    the LTU specified as part of the LTG and LC is not created or

    the LTG port data are implausible. To find out what circuit type was created with CRLTU, command DISP PORTcan be entered. The circuit type for a workstation must

    be TPCPRT.

    1.2.10 Workstation Test Port

    Up to 8 test ports can be assigned to a workstation. The directory numbers DN of the

    test ports must be defined in such a way that they cannot be accessed by ordinary sub-

    scribers. The circuit type for a workstation test port must be TETPCPRT. This informa-

    tion can be displayed with command DISP PORT.

    1.2.11 Workstation GroupIn centers with numerous workstations, it is possible to form workstation groups dedi-

    cated to different tasks (line testing/trunk testing).

    A group can consist of a maximum of 6 workstations. A workstation can belong to

    several groups at the same time (even all groups).

    The parameter DIR defines the direction in which outputs will be routed, e.g. to a work-

    station group in the exchange under test or to a workstation group in a maintenance

    center.

    Parameter FUNC defines the type of test for which the workstation group is responsible.

    Parameter PRONAM specifies the processor via which the group can be accessed

    (command DISP PRO/CR PRO).It must be ensured that the access to the group (CR

    WSTGRP, parameter PRONAM) matches the access to the workstations in the group

    (CR WSTparameter TERMID), otherwise the command will be rejected.

    Connections to remote workstation groups are controlled by means of unsolicited mes-

    sages. The assignment to workstation group and direction is made in accordance with

    the function (18) and direction (13) by means of an individual data type. The values

    of FUNC and DIR are defined in the parameters entered with MMLcommand CR

    WSTGRP. Queues are provided for cases where a specific TLWSor the entire worksta-

    tion group is busy. Incoming calls are rerouted to an announcement while waiting in the

    queue. Parameter WP (waiting places) defines the maximum number of calls that are

    allowed to wait be served per group. Calls in the queue that have not yet been presented

    wait for a maximum of 5 minutes in the queue before being released automatically. If aqueue is full, all further calls to this workstation or the workstation group are rejected.

    Commands are rejected if the specified workstation(s) has (have) not been created.

    1.3 Administration of Test Objects

    1.3.1 Subscriber Lines

    Before testing, state-interrogation and display commands should be entered to verify

    that the intended test object is in its normal configuration (ACT).

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    17/46

    A30828-Y1160-U3-1-7620

    17

    OMN:TE-AD Introduction (IN)

    Id:0900d805800a677b

    1.3.2 Administration of Thresholds for Line Testing

    Command MOD LTESTTHRis used to define thresholds for the resistance, capaci-

    tance, external voltage, loop resistance and pulse frequency and pulse duty ratio in sub-

    scriber line and station testing.

    Before a test is performed for the first time, the thresholds in the classes for SLMA:FPB,

    SLMA:FPS, SLMD,... must be modified.

    When a subscriber is created, threshold class 0 is automatically assigned.

    The thresholds defined for each threshold class can be displayed with command

    DISP LTESTTHR:THRCLA=x;.

    Command DISP LTESTTHR:SPCVAL=Y; is used to display threshold classes for which

    special values are entered.

    1.3.3 Test ClassesA threshold class is assigned to a subscriber with command

    MOD SLNACC:EQN=eqn, TESTCL=xx.

    1.3.4 Trunks

    Test data, test types and blockings are assigned to trunks with command ENTR TRDAT.

    A test path number is assigned to incoming trunks with parameter TSTDAT. The test

    path number is used to access the responder in remote-controlled trunk tests.

    Parameter TSTTYP is used to assign trunk group test data to the trunk that were entered

    with command ENTR TGTSTDAT. Up to 8 different test types can be entered for a trunk

    group.

    These data can be displayed with command DISP TRUNK.

    1.3.5 Trunk Group Test Data

    Test data are entered for national and international trunk groups with command ENTR

    TGTSTDAT.

    Parameter TSTCL defines a test class for the trunk. The test class represents the test

    method and the type of responder in the distant exchange.

    Test class 127 must be created for analog measurements on international trunks.

    Test class 128 must be created for analog measurements and bit error ratio measure-ments on international trunks.

    Test class 129 must be created for bit error ratio measurements (BERM) on international

    trunks.

    Parameter TSTMOD defines whether the trunks in the trunk group are to be tested

    directly or by remote access.

    If testing international trunks, the direct test option must be created.

    Parameter TSTVAL is used to enter an index for overall loss on the trunk for test classes

    1 to 126.

    In the case of test classes 127 and 128, parameter TSTVAL assigns templates for level

    and noise measurements. These templates are created with command CR TESTTHR.Parameter TSTVAL is not needed for test class 129.

    http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    18/46

  • 8/13/2019 Omn Te Ad Mobile

    19/46

    A30828-Y1160-U3-1-7620

    19

    OMN:TE-AD Introduction (IN)

    Id:0900d805800a677b

    send identification tone

    line supervision

    1.4.2 Tests with the ATE:T

    The automatic test equipment for trunks (ATE:T) is used to test analog PBXlines and

    the tones and signals generated by the tone generator, and responders and special cir-

    cuits.

    To safeguard test results, the ATE:T has a self-test facility and an automatic calibration.

    1.4.3 Automatic Tests with the TU

    The test unit (TU) is used to test circuit modules, subscriber lines and terminals in the

    DLU.

    To perform tests, one TU must be created for each DLU. In addition, a translationfunction (TLFI) must be created in the LTGBto which the DLU is connected.

    To safeguard test results, the TU has a self-test facility.

    1.4.4 Tests with the Ringback Service

    The ringback service (RBS) is used for the manual testing of analog and digital sub-

    scriber lines and terminals. The tests are controlled from the remote end by a mainte-

    nance technician at the customers premises. Tests of digital subscriber lines at BA and

    PA ports are controlled by ringback service integrated (RBSI) programs.

    1.4.5 ISDN Line TestsThe following functions are available for the automatic testing and fault clearance of

    ISDNsubscriber lines:

    1.4.6 SULIM

    The subscriber line measuring system (SULIM) is used for the manual and automatic

    testing of analog subscriber lines. The manual test functions are similar to those of the

    integrated line workstation (LWS). The automatic tests (routine tests) with SULIM allow

    line parameters to be checked.

    The start and end times for a routine test are determined by a test schedule. The lines

    to be tested are stored in directory number tables.

    Activate layer 1 TEST ISUB, TEST SUB

    Loop test at BA TEST LOOPBA

    Loop test at PA TEST PA

    Running digital sum (RDS) measurement START RDSMEAS

    BAperformance measurement ACT BAPERF

    PDCperformance measurement ACT PDCFEA

    http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    20/46

    20 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a677b

    Introduction (IN)

    1.5 Trunk Testing

    1.5.1 Testing with the Trunk Workstation

    The integrated trunk workstation (TWS) for the manual testing of trunks is used for fault

    location, for support in fault clearance and for testing trunks before they are placed in

    service (restored to service).

    At the trunk workstation, it is possible to set up calls, receive calls and start manually

    controlled tests and measurements. Administrative tasks and status requests for trunks

    are also possible here.

    To carry out test functions, the following must be created:

    conference equipment

    ATE:TM / ATE:N/ ATCO

    workstation test port

    headset port

    During manual trunk testing and fault clearance, the following can be measured:

    test tones

    composite level, unweighted

    composite level, weighted

    level monitoring with specified limit

    frequency spectra

    MFC or

    single frequency with tone pulse evaluation

    The announcement workstation (AWS) application provides a convenient user interface

    for connections to trunks, announcements or tone generator channels.

    1.5.2 Tests with the ATE:T

    The automatic test equipment for trunks (ATE:T) is used to test trunk circuits, incoming

    trunks and outgoing trunks in conjunction with a responder.

    The ATE:T can also be used to test analog PBXlines, the tones and signals generated

    by the tone generator, and responders and special circuits.

    To safeguard test results, the ATE:T has a self-test facility.

    1.5.3 Tests with the ATE:TM / ATE:N/ ATCOThe automatic test equipment for transmission measuring (ATE:TM/ ATE:N/ ATCO) is

    used for

    manual testing of trunks with the TWS

    automatic testing of international trunks TEST INTLTRK

    bit error ratio measurements on trunks with the assistance of a loopback at the

    remote endACT BERM

    http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    21/46

  • 8/13/2019 Omn Te Ad Mobile

    22/46

    22 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a676c

    Tasklist (TL)

    2 Tasklist (TL)

    gDisplay commands are only specified in the procedures if they are absolutely nec-essary. As a rule, display commands are not necessary to verify that a commandhas been executed. It is already obvious from the command acknowledgement

    issued by the system whether the input command was correctly executed (see also

    Operator Guidelines OGL). Should it be necessary for administrative reasons to

    receive an acknow edgement of the executed work in addition to the run listing, the

    content of the database can be displayed with the relevant commands (see CML)

    before and after, or only after, each task.In each task, only those parameters and

    identifiers are specified that are typical for the task in hand.

    2.1 Test Administration

    2.1.1 Operating statesDisplay port operating state .......................................................b STAT PORTDisplay trunk operating state ...................................................b STAT TRUNKDisplay CCGoperating state .......................................................b STAT CCGDisplay LTGoperating state .........................................................b STAT LTGDisplay DIUoperating state ...........................................................b STAT DIUDisplay MBoperating state.............................................................b STAT MBDisplay SNoperating state .............................................................b STAT SNDisplay DLUoperating state.........................................................b STAT DLUDisplay DLU module operating state ....................................b STAT DLUMODDisplay DLU port operating state........................................b STAT DLUPORTConfigure port...............................................................................b CONF PORTConfigure LTG.................................................................................b CONF LTGConfigure DIU...................................................................................b CONF DIUConfigure DLU.................................................................................b CONF DLUConfigure DLU module............................................................b CONF DLUMODConfigure DLU port................................................................b CONF DLUPORT

    2.1.2 Display operating states of test equipmentDisplay operating state of automatic test equipment ATE

    using: TGNO=x, TYPE=ATE ...........................................b STAT TEQDisplay operating state of director for bit error ratio measurementusing: TGNO=x, TYPE=ATEBDIR ...................................b STAT TEQ

    DIsplay operating state of responder for bit error ratio measurement

    using: TGNO=x, TYPE=ATEBRESP ...............................b STAT TEQDisplayoperating state of ATE operating as director in trunk test

    using: TGNO=x, TYPE=ATEDIR .....................................b STAT TEQDisplay operating state of ATE:TM / ATE:N/ ATCO

    using: TGNO=x, TYPE=ATEMAN....................................b STAT TEQDisplayoperating state of ATE operating as responder in trunk test

    using: TGNO=x, TYPE=ATEDIR .....................................b STAT TEQDisplay operating state of ATE:TM / ATE:N/ ATCO self-test

    using: TGNO=x, TYPE=ATESELF...................................b STAT TEQ

    http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    23/46

    A30828-Y1160-U3-1-7620

    23

    OMN:TE-AD Tasklist (TL)

    Id:0900d805800a676c

    Display operating state of conference equipment

    using: TGNO=x, TYPE=CE..............................................b STAT TEQDisplay operating state of digital loopback function for bit error

    ratio measurement using: TGNO=x, TYPE=DIGLP.........b STAT TEQDisplay operating state of end-to-end answer equipment for

    trunk test using: TGNO=x, TYPE=ETEAE.......................b STAT TEQDisplay operating state of metallic test access interface from

    test equipment to test object using: TGNO=x, TYPE=MANTT ................

    b STAT TEQDisplay operating state of metallic test access interface from

    test object to test equipment using: TGNO=x, TYPE=MAOGT ...............

    b STAT TEQDisplay operating state of ringback service in LTGB

    using: TGNO=x, TYPE=RBSI ..........................................b STAT TEQDisplay operating state of testset (test phone)

    using: TGNO=x, TYPE=TESTSET ..................................b STAT TEQDisplay operating state of responder for trunk test

    using: TGNO=x, TYPE=TEMLE.......................................b STAT TEQDisplay operating state of TLFB

    using: TGNO=x, TYPE=TLFB..........................................b STAT TEQDisplay operating state of TLFI

    using: TGNO=x, TYPE=TLFI ...........................................b STAT TEQDisplayoperating state of test unit in DLU

    using: DLU=dluno, LC=0-11-0

    using: DLU=dluno, LC=0-12-0

    using: DLU=dluno, LC=0-13-0 ...............................b STAT DLUPORT

    Display operating state of MTAusing: DLU=dluno, LC=1-13-0 ...............................b STAT DLUPORTDisplay operating state of LTA

    using: DLU=dluno, LC=1-14-0 ...............................b STAT DLUPORT

    2.1.3 Test equipmentDisplay test equipment ..................................................................b DISP TEQCreate test equipment .....................................................................b CR TEQModify test equipment ..................................................................b MOD TEQCancel test equipment ...................................................................b CAN TEQCreate testset (test phone) in DLU ...........................................................TP-002

    Cancel testset (test phone) .......................................................................TP-003Create ringback service ............................................................................TP-004

    2.1.4 Test equipment dataDisplay test equipment data ...................................................b DISP TEQDATEnter test equipment data .................................................b ENTR TEQDATCancel test equipment data ...................................................b CAN TEQDAT

    2.1.5 Thresholds for ATE/TUEnter thresholds for ATE/TU ....................................................b ENTR THRDisplay thresholds for ATE/TU ......................................................

    bDISP THR

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    24/46

  • 8/13/2019 Omn Te Ad Mobile

    25/46

    A30828-Y1160-U3-1-7620

    25

    OMN:TE-AD Tasklist (TL)

    Id:0900d805800a676c

    Display PBX lines .....................................................................b DISP PBXLNDisplay operating state of layer 1 ..........................................b STAT ILAYER1Display operating state of basic access ..........................................b STAT BADisplay DLUports with circuit variants ................................b DISP DLUPORTDisplay selected DLU port data .............................................b SEL DLUPORTDisplay FCS count.........................................................................b DISP FCSDisplay RDS measurement count.......................................b DISP RDSMEASDisplay count of transmitted and errored frames at PA..........b DISP PASTATDisplay layer-2 errors and bit error ratios for subscriber lines

    and PBX lines at PA ................................................b DISP BAFAULTDisplay intermediate results of performance measurement ...b DISP BAPERFDisplay fault conditions recorded for PBXs

    with PA.....................................................................b DISP PAFAULTDisplay performance data for PDC ......................................b DISP PDCPERFDisplay activation status of the feature for collecting and

    storing PDC performance data ..................................b DISP PDCFEADisplay PA channel status.................................................b DISP PACHSTATEnter line maintenance blocking ..........................................b ENTR LMBLKCancel line maintenance blocking ............................................b CAN LMBLK

    2.2.2 Administration of thresholds for line testingDisplay thresholds for each threshold class .......................b DISP LTESTTHRModify thresholds for each threshold class .......................b MOD LTESTTHR

    2.2.3 Test classes for subscriber lines

    Modify test class ....................................................................b MOD SLNACC

    2.2.4 TrunksDisplay trunk operating state...................................................b STAT TRUNKEnter trunk maintenance blocking ........................................b ENTR TMBLKCancel trunk maintenance blocking ..........................................b CAN TMBLK

    2.2.5 Trunk dataEnter trunk data....................................................................b ENTR TRDATCancel trunk data......................................................................b CAN TRDAT

    2.2.6 Trunk group test dataDisplay trunk group test data .............................................b DISP TGTSTDATEnter trunk group test data............................................b ENTR TGTSTDATModify trunk group test data.............................................b MOD TGTSTDATCancel trunk group test data..............................................b CAN TGTSTDAT

    2.2.7 Administration of thresholds for international trunk testingDisplay test thresholds .........................................................b DISP TESTTHRCreate test threshold ..............................................................b CR TESTTHRModify test threshold ...........................................................b MOD TESTTHRCancel test threshold ............................................................b CAN TESTTHR

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    26/46

  • 8/13/2019 Omn Te Ad Mobile

    27/46

    A30828-Y1160-U3-1-7620

    27

    OMN:TE-AD TP-002 - Create testset at DLU port

    Id:0900d8058018debb

    4 TP-002 - Create testset at DLU portThe unlock number (UNLNO) is entered in command CR TEQ/ MOD TEQ.

    1 Create testsetb CR TEQ:TGNO=tgno, TYPE=TESTSET, EQN=eqn;

    A unique symbolic name must be assigned to the TESTSET in parameter TGNO.

    2 Create destination for testsetIf required

    b CR DEST:DEST=TESTSET;

    3 Create route for testsetIf required

    b CR ROUTE:DEST=TESTSET, TGNO=tgno, SSDI=15, EOS=SIGN,ROUTE=route;

    4 Create test point for testsetIf required

    b CR TEPT:CODE=code, DEST=TESTSET;

    5 Create zone point for testsetIf required

    b CR ZOPT:CODE=code, ZOCHA=NOPULSE;

    6 Configure DLU portb CONF DLUPORT:DLU=dlu, LC=lc, OST=MBL;

    b CONF DLUPORT:DLU=dlu, LC=lc, OST=ACT;

    7 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    28/46

    28 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a6779

    TP-003 - Cancel testset

    5 TP-003 - Cancel testsetThe cancel command will be rejected if the routing table still contains a reference to the

    testset and if this testset is the only one in the trunk group. If the route is a primary route,

    the associated test point must be canceled first.

    1 Display testsetb DISP TEQ:TGNO=X, TYPE=TESTSET;command repetition

    TEST EQUIPMENT DATA

    TGNO TYPE EQN / LTG-LC LTGMODE DIGITS LTGMIN MU UNL OR1

    BLK LAC LTGMAX OR2

    ------+--------+-------------+-------------+--------+------+---+---+----

    @##### @####### @############ @############ @####### @### @ @# @###

    2 Block testsetb MOD TEQ:TGNO=tgno, EQN=eqn, BLK=ADMIN/;

    3 Cancel zone point for testsetb CAN ZOPT:CODE=code, INCEPT=UNOBDE0;

    4 Cancel test point for testsetb CAN TEPT:CODE=code, INCEPT=incept;

    5 Cancel route for testsetb CAN ROUTE:DEST=TESTSET, TGNO=tgno, ROUTE=route;

    6 Cancel destination for testsetb CAN DEST:DEST=dest;

    7 Cancel testsetb CAN TEQ:TGNO=tgno, EQN=eqn;

    8 END

    http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    29/46

    A30828-Y1160-U3-1-7620

    29

    OMN:TE-AD TP-004 - Create ringback service

    Id:0900d805800a6778

    6 TP-004 - Create ringback serviceCreate ringback service for analog and digital DLUsubscribers.

    1 Display LTUb DISP LTU:LTG=ltg;command repetition

    LTG LTU TYPE APPLIC MODVAR

    -------+----+-----+-------+---------------------------------------

    @### @ V09 @##### @######################################

    2 Decision blockDoes this LTG contain an LTU of type V09?

    Yesh......... 4Noh ......... 3

    3 Create LTUAn LTU of TYPE V09 must be created for TLFI and RBSI. LTU 4, 5 or 6 can be selected.

    b CR LTU:LTG=ltg, LTU=ltu, TYPE=V09;

    4 Display port datab DISP PORT:LTG=ltg, LC=lc;command repetition

    LTG = @##### LC = @### LCTYPE = TLFIC LCVAR = @ TYPE = @#######

    LTG = @##### LC = @### LCTYPE = TLFOG LCVAR = @ TYPE = @#######

    5 Decision blockIs a TLFI created?

    Yesh......... 7Noh ......... 6

    6 Create TLFIb CR TEQ:TGNO=tgno, TYPE=TLFI, LTG=ltg, LC=lc;The TLFI can be created at four LTU ports: 2, 10, 18, 26. The TLFI occupies two suc-

    cessive ports. The first port must be specified, the second is assigned automatically.

    7 Create RBSIb CR TEQ:TGNO=tgno, TYPE=RBSI, LTG=ltg, LC=lc;The RBSI can be created at four LTU ports: 4,12, 20, 28.

    http://a200.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    30/46

    30 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a6778

    TP-004 - Create ringback service

    8 Display destination for RBSIb DISP DEST:DEST=dest;

    9 Decision blockIs a destination created for RBSI?

    Yesh......... 11Noh.......... 10

    10 Create destination for RBSIb CR DEST:DEST=dest;

    11 Display route for RBSIb DISP ROUTE:DEST=dest;

    12 Decision blockIs a route created for RBSI?

    Yesh......... 15Noh.......... 13

    13 Create route for RBSIb CR ROUTE:DEST=dest, TGNO=tgno, SSDI=7, EOS=SIGN, ROUTE=route;

    14 Display testpoint for RBSIb DISP TEPT:DEST=dest;

    15 Decision blockIs a test point created for RBSI ?

    Yesh......... 17Noh.......... 16

    16 Create test point for RBSIb CR TEPT:CODE=code, DEST=dest;

    17 Create exchange identifierb MOD CALLPOPT:RBSIN=rbsin;Up to 8 digits can be defined an an identifier with parameter RBSIN.

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    31/46

    A30828-Y1160-U3-1-7620

    31

    OMN:TE-AD TP-004 - Create ringback service

    Id:0900d805800a6778

    18 END

  • 8/13/2019 Omn Te Ad Mobile

    32/46

    32 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a6777

    TP-011 - Create SMC as TLWS workstation connectedvia NetM

    7 TP-011 - Create SMC as TLWS workstation

    connected via NetM

    A Subscriber Maintenance Commander (SMC) can be created as a workstation for lineand trunk testing. This workstation can be connected to an LTGof type LTGB. It is con-

    nected to the system via the NetManager (NetM).

    1 Create intercept tonesb CR INC:INCEPT=TESTWAIT, TONE=INFOTONE;

    b CR INC:INCEPT=NOTESTOP, TONE=SUBBUSY;

    2 Create directory number volume for TLWSb CR DN:DN=dn&&dn, LAC=lac;

    3 Create code point for TLWSb CR CPT:CODE=code, TRATYP=CPTDN, LAC=lac;

    4 Create zone point for TLWSb CR ZOPT:CODE=code, ZOCHA=NOPULSE;

    5 Create LTU for TLWSAn LTU of TYPE V11 or of TYPE = V02must be created for the workstation.

    b CR LTU:LTG=ltg, LTU=ltu, TYPE=type;

    6 Create workstation for TLWS userid"CSname" is the processorname created for the NetM SMC CS in CP database. sta-

    tionno is the station number which is assigned to one NT userid (via TLWS administra-

    tion program.)

    b CR WST:WST=wst, TERMID=CSname-stationno, LAC=lac, WSTSN=wstsn,DN=dn, LTG=ltg, LC=lc, WP=8, APPLID=DIALG;

    7 Create WST test port for TLWSUp to 8 test ports can be created per workstation.

    b CR WSTPRT:WST=wst, NO=no, LTG=ltg, LC=lc, LAC=lac, DN=dn;

    8 Create destination for TLWS groupb CR DEST:DEST=dest;

    http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    33/46

    A30828-Y1160-U3-1-7620

    33

    OMN:TE-AD TP-011 - Create SMC as TLWS workstation connectedvia NetM

    Id:0900d805800a6777

    9 Create TLWS groupFor trunk test/maintenance using FUNC=TRKMNT1

    For line test/maintenance using FUNC=LNMNT1b CR WSTGRP:WSTGRP=wstgrp, DIR=DIR1, FUNC=func, WP=4, WST=PC1X;

    10 Create route for TLWS groupb CR ROUTE:TGNO=tgno, DEST=dest, ROUTE=1, SSDI=4, EOS=SIGN;

    11 Create test point for TLWS groupb CR TEPT:CODE=code, DEST=dest, LAC=lac;

    12 Create zone point for TLWS groupb CR ZOPT:CODE=code, ZOCHA=NOPULSE;

    13 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    34/46

    34 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a6776

    TP-012 - Create OMT as TLWS workstation

    8 TP-012 - Create OMT as TLWS workstationAn Operation and Maintenance Terminal (OMT) can be created as a workstation for line

    and trunk testing. This workstation can be connected to an LTGof type LTGB.

    gOnly one workstation can be created per switch for the local OMT

    1 Create intercept tonesb CR INC:INCEPT=TESTWAIT, TONE=INFOTONE;

    b CR INC:INCEPT=NOTESTOP, TONE=SUBBUSY;

    2 Create directory number volume for TLWS

    b CR DN:DN=dn&&dn, LAC=lac;

    3 Create code point for TLWSb CR CPT:CODE=code, TRATYP=CPTDN, LAC=lac;

    4 Create zone point for TLWSb CR ZOPT:CODE=code, ZOCHA=NOPULSE;

    5 Create LTU for TLWSAn LTU of TYPE V11 or of TYPE = V02must be created for the workstation.

    b CR LTU:LTG=ltg, LTU=ltu, TYPE=type;

    6 Create workstation for TLWS useridThe terminal identification (TERMID) is equal to the local processor name (PRO-

    TYP=SSP) which must already exist in the system.

    b CR WST:WST=wst, TERMID=processor name, LAC=lac, WSTSN=wstsn,DN=dn, LTG=ltg, LC=lc, WP=8;

    7 Create WST test port for TLWSUp to 8 test ports can be created per workstation.

    b CR WSTPRT:WST=wst, NO=no, LTG=ltg, LC=lc, LAC=lac, DN=dn;

    8 Create destination for TLWS groupb CR DEST:DEST=dest;

    http://a200.pdf/http://a200.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://a200.pdf/http://a200.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    35/46

    A30828-Y1160-U3-1-7620

    35

    OMN:TE-AD TP-012 - Create OMT as TLWS workstation

    Id:0900d805800a6776

    9 Create TLWS groupFor trunk test/maintenance using FUNC=TRKMNT1

    For line test/maintenance using FUNC=LNMNT1b CR WSTGRP:WSTGRP=wstgrp, DIR=DIR1, FUNC=func, WP=4, WST=PC1X;

    10 Create route for TLWS groupb CR ROUTE:TGNO=tgno, DEST=dest, ROUTE=1, SSDI=4, EOS=SIGN;

    11 Create test point for TLWS groupb CR TEPT:CODE=code, DEST=dest, LAC=lac;

    12 Create zone point for TLWS groupb CR ZOPT:CODE=code, ZOCHA=NOPULSE;

    13 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    36/46

    36 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a6775

    TP-015 - Cancel workstation

    9 TP-015 - Cancel workstationA workstation can only be canceled when the following conditions are met:

    The workstation must not be active.

    There must be no test ports assigned to the workstation.

    The workstation must not belong to a workstation group.

    1 Check status of workstationb STAT WST:WST=wst;command repetition

    STATUS OF WORK STATION

    WSTNAME:@##### HEADSET STATE:@############# INCOMING CALLS:@########

    NO OF WAITING CALLS: @#

    T E S T O B J E C T

    EQN

    NO STAT MODE DIR CALLTYPE DN TOGCH(LTG-LC) TGNO LNO CIC

    --+----+-----+---+-----------+--------+-------------+------+-----+------

    @# @### @#### @## @########## @####### @############ @##### @#### @#####

    2 Decision blockIs the headset state DEACTIVATED?

    Yesh......... 4Noh.......... 3

    3 Deactivate workstationb DACT WST;

    4 Display workstation test portb DISP WSTPRT:WST=wst;command repetition

    DATA OF WORK STATION TEST PORT

    WST NO LTG LC LAC DN BLK ORIG1

    -------+-+-------+-----+------+--------+--------+------

    @##### @ @##### @### @##### @####### @##### @###

    5 Decision blockAre workstation test ports still assigned?

    Yesh......... 6Noh.......... 7

    http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    37/46

    A30828-Y1160-U3-1-7620

    37

    OMN:TE-AD TP-015 - Cancel workstation

    Id:0900d805800a6775

    6 Cancel workstation test portb CAN WSTPRT:WST=wst, NO=no;

    7 Display workstation groupb DISP WSTGRP:WSTGRP=X;command repetition

    DATA OF WORK STATION GROUP

    WSTGRP DIR FUNC PRONAM APPLID WP BLK WST

    ------+----+-------+--------+------+--+-------+-------

    @##### @### @###### @####### @#### @# @##### @#####

    8 Decision blockIs the workstation assigned to a workstation group?

    Yesh......... 9Noh ......... 10

    9 Modify workstation groupb MOD WSTGRP:WSTGRP=wstgrp, WST= /wst;

    10 Cancel workstationb CAN WST:WST=wst;

    11 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    38/46

    38 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a6774

    TP-016 - Modify worktstation data

    10 TP-016 - Modify worktstation dataThe command MOD WSTcan be used to modify the data stored for workstations.

    1 Display workstation datab DISP WST:WST=X;command repetition

    WORK STATION DATA

    WST TERMID APPLID LTG LC WP COS BLK ORIG1

    ------+-------------+------+-------+----+--+---------+------+-----

    @##### @############ @#### @###### @### @ @######## @##### @###

    WORK STATION DATA

    WST LAC WSTSN DN TAPRT

    ------+------+--------+--------+-----------

    @##### @##### @####### @####### @##########

    2 Modify workstation datab MOD WST:WST=wst, TERMID=termid, APPLID=applid, DN=dn, WP=wp,

    ORIG1=orig1, TAPRT=taprt, BLK=blk;

    3 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    39/46

    A30828-Y1160-U3-1-7620

    39

    OMN:TE-AD TP-017 - Modify workstation group data

    Id:0900d805800a6773

    11 TP-017 - Modify workstation group dataThe command MOD WSTGRPcan be used to modify the data stored for workstation

    groups.

    1 Display workstation group datab DISP WSTGRP:WSTGRP=X;command repetition

    DATA OF WORK STATION GROUP

    WSTGRP DIR FUNC PRONAM APPLID WP BLK WST

    ------+----+-------+--------+------+--+-------+-------

    @##### @### @###### @####### @#### @# @##### @#####

    2 Modify workstation group datab MOD WSTGRP:WSTGRP=wstgrp, DIR=dir, FUNC=func, PRONAM=pronam,

    APPLID=applid, WST=wst, WP=wp, BLK=blk;

    3 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    40/46

  • 8/13/2019 Omn Te Ad Mobile

    41/46

    A30828-Y1160-U3-1-7620

    41

    OMN:TE-AD TP-018 - Cancel workstation group

    Id:0900d805800a6772

    7 Cancel workstation groupb CAN WSTGRP:WSTGRP=wstgrp;

    8 END

    http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    42/46

    42 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d805800a6771

    TP-019 - Cancel workstation test port

    13 TP-019 - Cancel workstation test portCommand CAN WSTPRTcancels a test port of a workstation. The specified test port is

    only canceled if its transient operating state allows this.

    The directory number DN of a canceled test port is redirected to NU tone (number unob-

    tainable).

    1 Display workstation test portsb STAT WST:WST=wst;command repetition

    STATUS OF WORK STATION

    WSTNAME:@##### HEADSET STATE:@############# INCOMING CALLS:@########

    NO OF WAITING CALLS: @#

    T E S T O B J E C T

    EQN

    NO STAT MODE DIR CALLTYPE DN TOGCH(LTG-LC) TGNO LNO CIC

    --+----+-----+---+-----------+--------+-------------+------+-----+------

    @# @### @#### @## @########## @####### @############ @##### @#### @#####

    2 Cancel workstation portb CAN WSTPRT:WST=wst, NO=no;

    3 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    43/46

    A30828-Y1160-U3-1-7620

    43

    OMN:TE-AD TP-021 - Display intermediate test results

    Id:0900d805800a6770

    14 TP-021 - Display intermediate test resultsIf you do not know the job number, enter command DISP JOBto obtain a list of general

    job data.

    Look for the command code of the test job in this list. The job number listed for the

    command code must be specified in command DISP TSTRES.

    1 Display general job dataIf required

    b DISP JOB:JN=X;

    2 Display intermediate test resultsb DISP TSTRES:JN=jn;

    3 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    44/46

    44 A30828-Y1160-U3-1-7620

    OMN:TE-AD

    Id:0900d8058018dee5

    TP-022 - Display test job

    15 TP-022 - Display test jobIf you do not know the job number, enter command DISP JOBto obtain a list of general

    job data.

    Look for the command code of the test job in this list. The job number listed for the

    command code must be specified in command DISP TSTJOB.

    1 Display general job dataIf required

    b DISP JOB:JN=X;

    2 Display test jobb DISP TSTJOB:JN=jn;

    3 END

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    45/46

    A30828-Y1160-U3-1-7620

    45

    OMN:TE-AD TP-030 - Display test results from archive file

    Id:0900d8058018df0c

    16 TP-030 - Display test results from archive file

    1 Decision blockDo you know the name of the archive file containing the test results?

    Yesh......... 3Noh ......... 2

    2 Display archive filesb DISP AFILE:AFILE=X;command repetition

    AFILE SIZE TYPE THRU THRD THRF COMMENT------------------+--------+-------+-----+-----+---------+--------------

    @################ @###### @##### @## @## @###### @#############

    Archive files (AFILE) containing test results are usually named TESTRES or RT.TES-

    TRES.

    3 Display archive file entriesb DISP AENTRY:AFILE=afile, TOC=YES;command repetition

    AENTRY DATE TIME JOBNO CONTEXT FORMAT ALPRIO

    ------------------------------------------------------------------------

    @#### @####### @####### @### @################## @#######

    4 Select test results from the archive fileb SEL AENTRY:AFILE=afile, DATE=date, JN=jn, MSG=msg;

    By entering parameter DATE, you can define the dates for which test results are

    output.

    By entering parameter JN, you can output test results of a specific test job.

    A By entering parameter MSG (combination of test command and output masknumber) you can output individual results of a test job.

    h ......... 5

    5 Inputs for parameter MSGTest results Statistical

    report

    Busy and

    inacces-

    sible test

    objects

    Error

    messages

    Command

    repetition

    TEST LIC -6524 -6540 -6194 -6513

    TEST LTGPOS -6529 -6540 -6194 -6513

    TEST CTYPE -6529 -6540 -6194 -6513

    http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/http://omlexch.pdf/http://cmlexch.pdf/
  • 8/13/2019 Omn Te Ad Mobile

    46/46

    OMN:TE-ADTP-030 - Display test results from archive file

    6 END

    TEST TC -6538 -6540 -6535 -6194 -6513

    TEST DLULC -6491 -4027 -3891 -4010 -2795

    TEST ISUB -6511 -4024 -3893 -4010 -2795

    TEST SLC -6493 (DLU) -4027 -3891 -4010

    (DLU)

    TEST SUB -6495 -6511 -3893

    (DLU)

    -4010

    Test

    results

    Statistical

    report

    List of faulty

    responders

    List of

    responder

    faults

    Error

    messa

    ges

    Comma

    nd repe-

    tition

    TEST PBXLN -6516 -6540 -6474 -6112 -6194 -6513

    TEST TRUNK -6482 -6540 -6474 -6112 -6194 -6513

    TEST INTLTRK -6477 -6540 -6474 -6112 -6194 -6513

    http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/http://cmlexch.pdf/

Recommended