+ All Categories
Home > Documents > Omron 3G3RX-V1 AC Drives Brochure · 3G3RX-V1 AC Drives Customized to your ... the inverter itself...

Omron 3G3RX-V1 AC Drives Brochure · 3G3RX-V1 AC Drives Customized to your ... the inverter itself...

Date post: 29-Jun-2018
Category:
Upload: leduong
View: 219 times
Download: 0 times
Share this document with a friend
24
» High motor-control performance » Built-in know-how functionality » Uncompromising Omron quality 3G3RX-V1 AC Drives Customized to your machine
Transcript

» H i g h m o to r - co n t ro l p e r fo r m a n ce

» Bu i l t - i n k n ow - h ow f u n c t i o n a l i ty » U n co m p ro m i s i n g O m ro n q u a l i ty

3G3RX-V1 AC DrivesCustomized to your machine

G5 Series Servo System

2

Key features include:

• Up to 132 kW (200 HP)

• Built-in EMC filter

• Sensor-less and vector closed-loop control

• High starting torque in open loop

(200% at 0.3 Hz)

• Full torque at 0 Hz in closed loop

• Built-in logic programmability

• Built-in application functionality

• Automatic energy saving

• Micro-surge voltage suppression

• Built-in Modbus RS485

(options for other networks)

High performance to match your application

Omron realizes that you need quality and reliability, plus the ability to easily and quickly customize your inverter to the application at hand. And with the 3G3RX-V1, you have the perfect tool for the job.

Naturally, it combines the same high level of quality and performance for which Omron is renowned. It also has abundant application functionality on board and you can customize it yourself to match your precise requirements.

3

Customize your inverter

CX-Drive enables you to make your own programs to suit your machine, e.g., for an unwinding application.

Positioning functionality

Simple positioning is handled bythe inverter itself without the need for an external motion controller. Functions include pulse trace position control mode, homing and position teaching.

Focused on applicationThe inverter is pre-programmed with special application functionality, e.g., brake control, by-pass motor control, orientation stop, interruption filling and switching from speed to positioning control, etc.

4

From high torque to high motor efficiency...

5

Sensor-less vector control

at 0 Hz domain

With the benefit of patented 0 Hzdomain open-loop control mode, the3G3RX-V1 can develop 150% torque at 0 Hzallowing zero speed load holding.Moreover, an improved sensor-lessvector control algorithm enables the 3G3RX-V1 to develop more than 200% starting torque at 0.3 Hz.

Cost and space saving filter

The 3G3RX-V1 has a built-in EMC filter thatsaves on cost and space comparedwith the standard external filter solution.

3 ph : EN61800-3 cat. C2

Long life design3G3RX-V1 has been designed with high quality components to guarantee a long operation life and minimize downtime. It includes a versatile maintenancefunction that warns the user in theevent of DC bus capacitor temperaturerise or cooling speed reduction.

10NO

MAINTENANCE

Y E A R S

100%

200%

Torq

ue

(per

cent

age

of ra

ting)

600 1200 1800

Rotation speed (min)

120110

1009080706050403020100

Frequency (Hz)

Leve

l (dB

V)

Conducted emission data

Integrated EMC filter

No filter

500k 1M 2M 5M 10M 20M 30M200150

Reliability with environmentalresponsibilityOmron is renowned for the reliabilityof its products. Moreover, Omron’spolicy is to offer environmentallysafe products free from any bannedsubstances.

6 Frequency Inverters

System Configuration

3G3RX-V1Customized to your machine• Upto132kW(200HP)• Highstartingtorqueinopenloop:200%at0.3Hz• Fulltorqueat0Hzinclosedloop• Sensor-lessandvectorclosed-loopcontrol• Built-inEMCfilter• Built-inlogicprogrammability• Built-inapplicationfunctionality• Positioningfunctionality• Automaticenergysaving• Micro-surgevoltagesuppression• ModbusRS485(optionsforothernetworks)• CE,cULus,RoHSRatings

• 200VClassthree-phase,0.4to55kW(1/2to75HP)• 400VClassthreephase,0.4to132kW(1/2to200HP)

Choke

Remote Operatorwith 2-line LCD display

Remote Operator Extension Cable

Output AC Reactor

Braking chopper

Braking Resistor

Option units

ACTIVEPOWER

OVERCURRENT

BUSS

BUSS

+

R R

BC...CH O P PE R

DANGERHIGH VOLTAGE !

RJ45 - USB CableSoftware:CX-Drive in CX-OneMCCB

Filter

Input AC Reactor

Motor

Ground

Power Supply

DC Reactor

C22

R52C24PE

C16

U11

U8R6

C26

C28

JP3

U6

U7

T1

U9++

R15

R15R25

R15R20R30

R7

R5C5

R21

U14

C17R14

R28

RR11

JP1

C1

U10

C3

R5R1 R2

R36R3C2

1

R35

R70

R120

R75

R78

R114C2

2+

+

U1+

C35

R99U12R9

5

R39R40R57

R56

D6

R6

U15

R54

R55

R8

TR2 11R1

1R1

10R1

07

R113

TR1

C13

U13

C10

SI-N

CODE No.

U17

73600-C0210

JP5 JP6

RT4

R10R10 R105

R102 C12

C11R94R97

R96

C20

R95

C39

R131

Y1

U10

C33

3G3RX-V1

73G3RX-V1

Type Designation

Specifications

3G3RX-V1 series

A: IP20 B: IP00

3 G 3 R X A 4 0 0 4 - V 1

Voltage:2: Three-phase 200 VAC4: Three-phase 400 VAC

Max. applicable motor output004: 0.4 kW (1/2 HP) to13K: 132 kW (200 HP)

Three-phase 3G3RX-9-V1 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A2185 A2220 A2300 A2370 A2450 A2550

Applicable motor capacity1

kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55

HP 1/2 1 2 3 5 71/2 10 15 20 25 30 40 50 60 75

Output characteristics

Inverter capacity kVA

200 V 1.0 1.7 2.5 3.6 5.7 8.3 11.0 15.9 22.1 26.3 32.9 41.9 50.2 63.0 76.2

240 V 1.2 2.0 3.1 4.3 6.8 9.9 13.3 19.1 26.6 31.5 39.4 50.2 60.2 75.6 91.4

Rated output current (A) 3.0 5.0 7.5 10.5 16.5 24 32 46 64 76 95 121 145 182 220

Max. output voltage Proportionaltoinputvoltage:0to240V

Max. output frequency 400Hz

Power supply

Rated input voltage and frequency 3-phase200to240V50/60Hz

Allowable voltage fluctuation -15%to+10%

Allowable frequency fluctuation 5%

Braking

Regenerative braking InternalBRDcircuit(externaldischargeresistor)Externalregenerativebrakingunit

Minimum connectable resistance 50 50 35 35 35 16 10 10 7.5 7.5 5

Protective structure IP20

Cooling method Forcedaircooling

Three-phase 3G3RX-9-V1 A4004 A4007 A4015 A4022 A4037 A4055 A4075 A4110 A4150 A4185 A4220 A4300 A4370 A4450 A4550 B4750 B4900 B411K B413K

Applicable motor capacity1

kW 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132

HP 1/2 1 2 3 5 71/2 10 15 20 25 30 40 50 60 75 100 125 150 200

Output characteristics

Inverter capacity kVA

400 V 1.0 1.7 2.5 3.6 6.2 9.7 13.1 17.3 22.1 26.3 33.2 40.1 51.9 63.0 77.6 103.2 121.9 150.3 180.1

480 V 1.2 2.0 3.1 4.3 7.4 11.6 15.8 20.7 26.6 31.5 39.9 48.2 62.3 75.6 93.1 123.8 146.3 180.4 216.1

Rated output current (A) 1.5 2.5 3.8 5.3 9.0 14 19 25 32 38 48 58 75 91 112 149 176 217 260

Max. output voltage Proportionaltoinputvoltage:0to480V

Max. output frequency 400Hz

Power supply

Rated input voltage and frequency 3-phase380to480V50/60Hz

Allowable voltage fluctuation -15%to+10%

Allowable frequency fluctuation 5%

Braking

Regenerative braking InternalBRDcircuit(externaldischargeresistor)ExternalregenerativebrakingunitMinimum connectable

resistance 100 100 100 100 70 70 35 35 24 24 20

Protective structure IP20 IP00

Cooling method Forcedaircooling

200 V class

400 V class

Note: 1.Basedonastandard3-Phasestandardmotor.

Note: 1.Basedonastandard3-Phasestandardmotor.

8 Frequency Inverters

Specifications

Common specifications

Model number 3G3RX-9-V1 Specifications

Controlfunctions

Controlmethods Phase-to-phasesinusoidalpulsewithmodulationPWM(Sensorlessvectorcontrol,V/F)Outputfrequencyrange 0.10..1000.00Hz(withrestrictionsabove400Hz)

FrequencyprecisionDigitalsetvalue:±0.01%ofthemax.frequencyAnalogsetvalue:±0.2%ofthemax.frequency(25±10ºC)

ResolutionoffrequencysetvalueDigitalsetvalue:0.01Hz

Analogsetvalue:1/1000ofmaximumfrequency

Resolutionofoutputfrequency 0.01HzStartingtorque 200%/0.5Hz

OverloadcapabilityDualrating:Heavyduty(CT):150%for1minuteNormalDuty(VT):120%for1minute

Frequencysetvalue 0to10VDC(10KΩ),4to20mA(100Ω),RS485Modbus,Networkoptions

V/fCharacteristics V/foptionallychangeableatbasefrequenciesof30to400Hz,V/fbrakingconstanttorque,reductiontorque,sensor-lessvectorcontrol,sensor-lessvectorcontrolat0Hz

Functionality

Inputssignals

FW(forwardruncommand),RV(reverseruncommand),CF1~CF4(multi-stagespeedsetting),JG(jogcommand),DB(externalbraking),SET(setsecondmotor),2CH(2-stageaccel./decel.command),FRS(freerunstopcommand),EXT(externaltrip),USP(startupfunction),CS(commercialpowerswitchover),SFT(softlock),AT(analoginputselection),RS(reset),PTC(thermistorthermalprotection),STA(start),STP(stop),F/R(forward/reverse),PID(PIDdisable),PIDC(PIDreset),UP(remotecontrolupfunction),DWN(remotecontroldownfunction),UDC(remotecontroldataclear),OPE(operatorcontrol),SF1~SF7(multi-stagespeedsetting;bitoperation),OLR(overloadrestriction),TL(torquelimitenable),TRQ1(torquelimitchangeover1),TRQ2(torquelimitchangeover2),BOK(Brakingconfirmation),LAC(LADcancellation),PCLR(positiondeviationclear),ADD(addfrequencyenable),F-TM(forceterminalmode),ATR(permissionoftorquecommandinput),KHC(Cumulativepowerclear),MI1~MI7(generalpurposeinputsforEzSQ),AHD(analogcommandhold),CP1~CP3(multistagepositionswitches),ORL(limitsignalofzero-return),ORC(triggersignalofzero-return),SPD(speed/positionchangeover),GS1~GS2(STOinputs,safetyrelatedsignals),485(Startingcommunicationsignal),PRG(executingEzSQprogram),HLD(retainoutputfrequency),ROK(permissionofruncommand),EB(rotationdirectiondetectionofB-phase),DISP(displaylimitation),OP(optioncontrolsignal),NO(nofunction)

Outputsignals

5opencollectoroutputterminals:NO/NCswitchable,sink/sourcelogicswitchable1relay(SPDTcontact)outputterminal:NO/NCswitchable[Terminalfunction]6functionscanbeselectedfromamong45.SignalduringRUN(RUN),Constantspeedarrivalsignal(FA1),Oversetfrequencyarrivalsignal(FA2),Overloadwarning(OL),ExcessivePIDdeviation(OD),Alarmsignal(AL),Set-frequency-onlyarrivalsignal(FA3),Overtorque(OTQ),Signalduringmomentarypowerinterruption(IP),Signalduringundervoltage(UV),Torquelimit(TRQ),RUNtimeexceeded(RNT),PowerONtimeexceeded(ONT),Thermalwarning(THM),Brakerelease(BRK),Brakeerror(BER),0-Hzsignal(ZS),Excessivespeeddeviation(DSE),Positionready(POK),Setfrequencyexceeded2(FA4),Setfrequencyonly2(FA5),Overloadwarning2(OL2),AnalogFVdisconnectiondetection(FVDc),AnalogFIdisconnectiondetection(FIDc),AnalogFEdisconnectiondetection(FEDc),PIDFBstatusoutput(FBV),Networkerror(NDc),Logicoperationoutput1(LOG1),Logicoperationoutput2(LOG2),Logicoperationoutput3(LOG3),Logicoperationoutput4(LOG4),Logicoperationoutput5(LOG5),Logicoperationoutput6(LOG6),Capacitorlifewarning(WAC),Coolingfanlifewarning(WAF),Startingcontactsignal(FR),Finoverheatwarning(OHF),Lightloaddetectionsignal(LOC),Operationready(IRDY),Forwardrun(FWR),Reverserun(RVR),Fatalfault(MJA),WindowcomparatorFV(WCFV),WindowcomparatorFI(WCFI),WindowcomparatorFE(WCFE),Alarmcodes0to3(AC0toAC3)

Standardfunctions

V/ffreesetting(7),Upper/lowerfrequencylimit,Frequencyjump,Curveacceleration/deceleration,Manualtorqueboostlevel/break,Energy-savingoperation,Analogmeteradjustment,Startingfrequency,Carrierfrequencyadjustment,Electronicthermalfunction,(freesettingavailable),Externalstart/end(frequency/rate),Analoginputselection,Tripretry,Restartduringmomentarypowerinterruption,Varioussignaloutputs,Reducedvoltagestartup,Overloadlimit,Initializationvaluesetting,Automaticdecelerationatpower-off,AVRfunction,Automaticacceleration/deceleration,Autotuning(Online/Offline),Hightorquemulti-motoroperationcontrol(sensor-lessvectorcontroloftwomonitorswithoneInverter)

Analoginputs Analoginputs0to10Vand-10to10V(10KΩ),4to20mA(100Ω)Analogoutputs Analogvoltageoutput,Analogcurrentoutput,PulsetrainoutputAccel/Deceltimes 0.01to3600.0s(line/curveselection)

DisplayStatusindicatorLED’sRun,Program,Power,Alarm,Hz,Amps,Volts,%Digitaloperator:Availabletomonitor23items,outputcurrent,outputfrequency,etc.

Protectionfunctions

Motoroverloadprotection ElectronicThermaloverloadrelayandPTCthermistorinputInstantaneousovercurrent 200%ofratedcurrentfor3secondsOverload 150%for1minute

Overvoltage 800Vfor400Vtypeand400Vfor200Vtype

Momentarypowerloss DeceleratestostopwithDCbuscontrolled,coasttostopCoolingfinoverheat TemperaturemonitoranderrordetectionStallpreventionlevel Stallpreventionduringacceleration/decelerationandconstantspeedGroundfault Detectionatpower-onPowerchargeindication OnwhenvoltagebetweenPandNishigherthan45V

Ambientconditions

Degreeofprotection IP20/IP00Ambienthumidity 90%RHorless(withoutcondensation)

Storagetemperature -20ºCto+65ºC(short-termtemperatureduringtransportation)

Ambienttemperature -10°Cto50°C

Installation Indoor(nocorrosivegas,dust,etc.)

Installationheight Max.1000m

Vibration 3G3RX-A9004-v1toA9220,5.9m/s2(0.6G),10to55Hz3G3RX-A9300-v1toB913K,2.94m/s2(0.3G),10to55Hz

93G3RX-V1

Dimensions

W

2-φ6

W1

W2

6

D

D1

H1 H

Figure 1

W2

D1

D2

2-φ7

W1

7

H1

H

W

D

Figure 2

W1

7

W2

D2 D1

H1

H

2-φ7

W

D

Figure 3

W

10

H1

H

2-φ10

D

W1

Figure 4

Unit:mm

10 Frequency Inverters

Dimensions Unit:mm

2-φ12

2-12300390

268

700

79

670

357

Figure 5

Voltage classInverter model 3G3RX-9-V1

FigureDimensions (Unit: mm)

Weight (kg)W W1 W2 H H1 D D1 D2

Three-phase200V

A2004

1 150 130 143 255 241 140 62 – 3.5A2007A2015A2022A2037A2055

2 210 189 203 260 246 170 82 13.6 6A2075A2110A2150

3 250 229 244 390 376 190 83 9.5 14A2185A2220A2300

4

310 265 – 540 510 195 – – 20A2370

390 300 – 550 520 250 – – 30A2450A2550 480 380 – 700 670 250 – – 43

Three-phase400V

A4004

1 150 130 143 255 241 140 62 – 3.5A4007A4015A4022A4037A4055

2 210 189 203 260 246 170 82 13.6 6A4075A4110A4150

3 250 229 244 390 376 190 83 9.5 14A4185A4220A4300

4

310 265 – 540 510 195 – – 22A4370

390 300 – 550 520 250 – – 30A4450A4550B4750

5390 300 – 700 670 268 – – 60

B4900B411K

480 300 – 740 710 270 – – 80B413K

113G3RX-V1

Dimensions Unit:mm

VoltageInverter model3G3RX-9-V1

Line filterDimensions (Unit: mm) Filter

typeWeight

(kg)L W H X Y M

3x200V

A2004

3G3AX-FIR2018-RE 305 125 45 290 110 M5

Footprint

2.0A2007A2015A2022A2037A2055

3G3AX-FIR2053-RE 312 212 56 296 189 M6 2.5A2075A2110A2150

3G3AX-FIR2110-RE455 110 240 414 80 – Booktype

8.0A2185A2220A2300 3G3AX-FIR2145-RE 8.6A2370

3G3AX-FIR3250-RE386 260 135 240 235 – Blocktype

13A2450A2550 3G3AX-FIR3320-RE 13.2

3x400V

A4004

3G3AX-FIR3010-RE 305 125 45 290 110 M5

Footprint

1.9A4007A4015A4022A4037A4055

3G3AX-FIR3030-RE 312 212 50 296 189 M6 2.2A4075A4110A4150

3G3AX-FIR3053-RE 451 252 60 435 229 M6 4.5A4185A4220A4300 3G3AX-FIR3064-RE 598 310 70 578 265 M8 7.0A4370 3G3AX-FIR3100-RE

455 110 240 414 80 – Booktype8.0

A44503G3AX-FIR3130-RE 8.6

A4550B4750

3G3AX-FIR3250-RE386 260 135 240 235 – Blocktype

13.0B4900B411K

3G3AX-FIR3320-RE 13.2B413K

Rasmi Line Filters

drive mounts

WH

Y

XL

outputflexes

Footprint Dimensions

W H

Y

XL

Book Type Dimensions

Y

WH

L X

Block Type Dimensions

12 Frequency Inverters

Dimensions

Voltage class

Model 3G3AX-9Dimensions (Unit: mm) Weight

(kg)A B1 B2 C1 C2 D E F

200V

RAI02800100-DE120

80

120 80 62 5.5 2.35RAI00880200-DERAI00350335-DE

18085

190140

556

5.5RAI00180670-DERAI00091000-DE

2056.5

RAI00071550-DE 105 85 11.7RAI00042300-DE 240 130 – 210 – 200 75 16.0

400V

RAI07700050-DE120

70120 80

525.5

1.75RAI03500100-DE

80 622.35

RAI01300170-DE 2.5RAI00740335-DE

18085

190140

556

5.5RAI00360500-DE

2056.5

RAI00290780-DE 105 85 11.7RAI00191150-DE 240 110 275 200 75 16.0

Model 3G3AX-9Dimensions (Unit: mm) Weight

(kg)A B2 C2 D E F

RAO11500026-DE 120 70 120 80 52 5.5 1.78RAO07600042-DE 120 70 120 80 52 5.5 1.78RAO04100075-DE 120 80 120 80 62 5.5 2.35RAO03000105-DE 120 80 120 80 62 5.5 2.35RAO01830180-DE 180 85 190 140 55 6 5.5RAO01150220-DE 180 85 190 140 55 6 5.5RAO00950320-DE 180 85 205 140 55 6 6.5RAO00630430-DE 180 95 205 140 65 6 9.1RAO00490640-DE 180 95 205 140 65 6 9.1RAO16300038-DE 120 70 120 80 52 5.5 1.78RAO11800053-DE 120 80 120 80 52 5.5 2.35RAO07300080-DE 120 80 120 80 62 5.5 2.35RAO04600110-DE 180 85 190 140 55 6 5.5RAO03600160-DE 180 85 205 140 55 6 6.5RAO02500220-DE 180 95 205 140 55 6 9.1RAO02000320-DE 180 105 205 140 85 6 11.7

Voltage class

Model 3G3AX-RC FigureDimensions (Unit: mm) Weight

(kg)A B C D E F G H

3-Phase200VAC

21400016-DE

1

84 113

96

101 66 5 7.5 2

1.2210700032-DE06750061-DE

105 1.6003510093-DE02510138-DE 116 1.9501600223-DE 108 135 124 120 82 6.5

9.59.5 3.20

01110309-DE120 152

136135 94

7 –

5.2000840437-DE 146 6.0000590614-DE

150 177160

160 115 211.4

00440859-DE 182.6 14.300301275-DE

2

195 161 162.5 185 88 10

– –

17.000231662-DE 196 123 25.500192015-DE

240188

200 228109

1234.0

00162500-DE 198 119 38.000133057-DE 228 149 42.0

3-Phase400VAC

43000020-DE

1

84 113

96

101 66 5 7.5 2

1.2227000030-DE 105 1.6014000047-DE10100069-DE 116 1.9506400116-DE 108 135 133 120 82 6.5

9.59.5 3.70

04410167-DE 120 152 136 135 947 –

5.2003350219-DE 146 6.0002330307-DE 150 177 160 160 115 2 11.401750430-DE 182.6 14.301200644-DE

2

195 161 162.5 185 88 10

– –

17.000920797-DE 196 123 25.500741042-DE

240188

200 228109

1234.0

00611236-DE 198 119 38.000501529-DE 228 149 42.0

Input AC Reactor

Output AC Reactor

DC Reactor

C

D

A

F

E

B

Figure 2

Unit:mm

Figure 1

Figure 2

133G3RX-V1

H

M T I L

LI

H

MT

LH

M

3G3AX-REM00K1��� Figure 1

Figure 4 Figure 5

Figure 2 Figure 3

H

M

L

I

11.5

46

20

106

89

Dimensions

Model 3G3AX-9Dimensions (Unit: mm)

B B1 H H1 T S

BCR4015045-TE82.5 40.5 150 138 220 6

BCR4017068-TEBCR2035090-TE

130 64.5 205 193 208 6BCR2070130-TEBCR4035090-TEBCR4070130-TEBCR4090240-TE 131 64.5 298 280 300 9

Chokes

Braking Unit Dimensions

X

H

YW Ø m

L

Ø d

Unit:mm

SB

H1

T1B

H

ACTIVEPOWER

OVERCURRENT

BU

SS

BU

SS

+

R R

BC...C H O PP ER

DANGERHIGH VOLTAGE !

Model FigureDimensions (Unit: mm) Weight

(kg)L H M I T

3G3AX-REM00K2070-IE

1

105 27 36 94 – 0.23G3AX-REM00K2120-IE

3G3AX-REM00K2200-IE

3G3AX-REM00K4075-IE

200 27 36 189 – 0.4253G3AX-REM00K4035-IE

3G3AX-REM00K4030-IE

3G3AX-REM00K5120-IE 260 27 36 249 – 0.58

3G3AX-REM00K6100-IE320 27 36 309 – 0.73

3G3AX-REM00K6035-IE

3G3AX-REM00K9070-IE

2 200 62 100 74 – 1.413G3AX-REM00K9020-IE

3G3AX-REM00K9017-IE

3G3AX-REM01K9070-IE3 365 73 105 350 70 4

3G3AX-REM01K9017-IE

3G3AX-REM02K1070-IE

4

310 100 240 295 210 73G3AX-REM02K1017-IE

3G3AX-REM03K5035-IE365 100 240 350 210 8

3G3AX-REM03K5010-IE

3G3AX-REM19K0006-IE

5140 350 180 100 160 6

3G3AX-REM19K0008-IE

3G3AX-REM19K0020-IE

3G3AX-REM19K0030-IE

3G3AX-REM38K0012-IE 240 350 180 200 160 11

Resistor

Model 3G3AX-Diameter Motor Dimensions (Unit: mm) Weight

(kg)d kW HP L W H X Y m

FER2102-RE 21 < 2.2 < 3 85 22 46 70 - 5 0.1

FER2515-RE 25 < 15 < 20 105 25 62 90 - 5 0.2

FER5045-RE 50 < 45 < 60 150 50 110 125 30 5 0.7

FER6055-RE 60 > 45 > 60 200 65 170 180 45 6 1.7

14 Frequency Inverters

Standard Connections

Main Circuit Terminals

Terminal symbol Terminal name Description

R/L1, S/L2, T/L3 Main power supply input terminal Connect the input AC power supply.

U/T1, V/T2, W/T3 Inverter output terminal Used to connect a 3-phase motor.

+1, P/+2 DC Reactor connection terminal Remove the shorting bar between terminals +1 and P/+2, and connect the optional DC reactor.

P/+2, RB Braking Resistor connection terminalConnect optional braking resistors. (If a braking torque is required.) The RB terminal is provided for the Inverters with 22 kW (30 HP) or lower capacity.

P/+2, N/- Regenerative Braking unit connection terminal

Ground terminalThis a ground terminal. Connect this terminal to the ground. Provide Class D grounding for 200 V class models, and class C grounding for 400 V class models.

153G3RX-V1

Control Circuit TerminalsAn

alog

Frequencyreferenceinput

FS Frequencyreferencepowersupplyoutput +10VDCpowersupplyfortheFVterminal. Allowableloadcurrent:20mAmax.

FV Frequencyreferenceinput(Voltagedirective)

Witha0to10VDCvoltageinput,thefrequencyreachesthemaximumat10V.SetatA014ifthemaximumfrequencyneedstobeachievedatlowerthan10V.

Inputimpedance10kΩAllowableinputvoltagerange:-0.3to+12VDC

FE Auxiliaryfrequencyreferenceinput(Voltagedirective)

Witha0to±10VDCvoltageinput,theFEsignalisaddedtothefrequencyreferencesignaloftheFVorFIterminal.Bychangingthesetting,thefrequencyreferencecanbeinputevenwiththeFEterminalindependently.

Inputimpedance10kΩAllowableinputvoltagerange:0to±12VDC

FI Frequencyreferenceinput(Currentdirective)

Witha4to20mADCcurrentinput,themaximumfrequencyissetat20mA.TheFIsignalisonlyactivewhentheATterminalisON.AllocatetheATfunctiontothemultifunctioninputterminal.

Inputimpedance100ΩAllowablemax.current:24mA

FC FrequencyreferencecommonCommonterminalforthefrequencysettingsignals(FV,FEandFI)andtheanalogoutputterminals(AMandAMI).Donotconnectthisterminaltotheground.

Monitoroutput

AM Multi-functionanalogoutput(Voltage)

Thisterminaloutputsasignalselectedfromthe"0to10VDCVoltageOutput"monitoritems:Outputfrequency,Outputcurrent,Outputtorque(with/withoutsign),Outputvoltage,Inputpower,Electronicthermalloadrate,LADfrequency,Motortemperature,andFintemperature.

Allowablemax.current:2mA

AMI Multi-functionanalogoutput(Current)

Thisterminaloutputsasignalselectedfromthe"4to20mADCCurrentOutput"monitoritems:Outputfrequency,Outputcurrent,Outputtorque(withoutsign),Outputvoltage,Inputpower,Electronicthermalloadrate,LADfrequency,Motortemperature,andFintemperature.

Allowableloadimpedance:250Ωmax.

Digital(contact)

Monitoroutput MP Multi-functiondigitaloutput

Thisterminaloutputsasignalselectedfromthe"0to10VDCVoltageOutput(PWM)"monitoritems:Outputfrequency,Outputcurrent,Outputtorque(withoutsign),Outputvoltage,Inputpower,Electronicthermalloadrate,LADfrequency,Motortemperature,Fintemperature,Digitaloutputfrequency,andDigitalcurrentmonitor."Digitaloutputfrequency",and"Digitalcurrentmonitor"outputadigitalpulseat0/10VDCpulsevoltageand50%dutyratio.

Allowablemax.current:1.2mAMax.frequency:3.6kHz

Powersupply

P24 Internal24VDC24VDCpowersupplyforcontactinputsignal.Whenthesourcelogicisselected,thisterminalfunctionsasthecontactinputcommonterminal.

Allowablemax.outputcurrent:100mA

SC Inputcommon

CommonterminalfortheinterfacepowersupplyP24terminal,thermistorinputTHterminalanddigitalmonitorMPterminal.Whenthesinklogicisselected,thisterminalfunctionsasthecontactinputcommonterminal.Donotconnectthisterminaltotheground.

Contactinput

RUNcommand FW Forwardrotation

commandterminalWhentheFWsignalisON,themotorrunsforward.WhenitisOFF,themotordeceleratesandstops.

[ContactinputONcondition]VoltagebetweeneachinputterminalandthePSCterminal:18VDCormoreInputimpedancebetweeneachinputterminalandthePSCterminal:4.7kΩAllowablemax.voltage:VoltagebetweeneachinputterminalandthePSCterminal:27VDCLoadcurrentat27VDCpowersupplyvoltage:Approx.5.6mA

Function/Selection

S1S2S3S4S5S6S7S8

Multi-functioninput

Select8functionsfromamongthe61functionsandallocatethemtoterminalsS1toS8.Note:OnlyterminalsS1andS3canbeusedfortheemergencyshutofffunction.

PSC Multi-functioninputcommon

Thesinkandsourcelogicforcontactinputcanbeswitchedbyconnectingashort-circuitbaronthecontrolterminalblock.Short-circuitingP24andSC Sinklogic,Short-circuitingSCandPSC SourcelogicToactivatecontactinputviaanexternalpowersupply,removetheshort-circuitbarandconnectPSCterminaltotheexternalinterfacecircuit.

Opencollectoroutput

Status/Factor

P1P2P3P4P5

Multi-functionoutput

Select5functionsfromamong45,andallocatethemtoterminalsP1throughP5.IfanalarmcodeisselectedinC062,terminalsP1toP3,orterminalsP1toP4alwaysoutputanalarmfactorcode(e.g.Invertertrip).ThesignalbetweeneachterminalandPCalwayscorrespondstothesinkorsourcelogic.

BetweeneachterminalandPCVoltagedrop4Vmax.atpower-onMax.allowablevoltage:27VDCMax.allowablecurrent:50mA

PC Multi-functionoutputcommon Commonterminalsformulti-functionoutputterminalsP1toP5.

Relayoutput

Status,alarm,etc.

MAMB Relayoutput Selectthedesiredfunctionsfromamong45functions,andallocate

them.SPDTcontactoutput.Byfactorydefault,therelayoutput(MA,MB)contactselection(C036)issetatNCcontactbetweenMA-MC,andNOcontactbetweenMBMC.

Contactmax.capacityMA-MC250VAC,2A(Resistance)0.2A(Induction)MB-MC250VAC,1A(Resistance)0.2A(Induction)Contactmin.capacity100VAC,10mA5VDC,100mA

MC Relayoutputcommon

Analog Analoginput Sensor TH Externalthermistorinput

terminal

Connectanexternalthermistortothisterminal,totriptheInverterwhenatemperatureerroroccurs.TheSCterminalfunctionsasthecommonterminal.[Recommendedthermistorcharacteristics]Allowableratedpower:100mWmin.Impedanceattemperatureerror:3kΩTemperatureerrordetectionlevelisadjustablebetween0and9999Ω.

Allowableinputvoltagerange0to8VDC[Inputcircuit]

16 Frequency Inverters

Heat Loss and Braking Units

Model 3G3RX-9-V1 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150 A2185 A2220 A2300 A2370 A2450 A2550Inverter capacity kVA

200 V 1.0 1.7 2.5 3.6 5.7 8.3 11.0 15.9 22.1 26.3 32.9 41.9 50.2 63.0 76.2240 V 1.2 2.0 3.1 4.3 6.8 9.9 13.3 19.1 26.6 31.5 39.4 50.2 60.2 75.6 91.4

Rated current (A) 3.0 5.0 7.5 10.5 16.5 24 32 46 64 76 95 121 145 182 220

Heatloss W

Losses at 70% load 64 76 102 127 179 242 312 435 575 698 820 1100 1345 1625 1975Losses at 100% load 70 88 125 160 235 325 425 600 800 975 1150 1550 1900 2300 2800

Efficiency at rated output 85.1 89.5 92.3 93.2 94.0 64.4 94.6 94.8 94.9 95.0 95.0 95.0 95.1 95.1 95.1Cooling method Forced-air-cooling

Model 3G3RX-9-V1 A4004 A4007 A4015 A4022 A4037 A4055 A4075 A4110 A4150 A4185 A4220 A4300 A4370 A4450 A4550 B4750 B4900 B411K B413KInverter capacity kVA

400 V 1.0 1.7 2.5 3.6 6.2 9.7 13.1 17.3 22.1 26.3 33.2 40.1 51.9 63.0 77.6 103.2 121.9 150.3 180.1480 V 1.2 2.0 3.1 4.3 7.4 11.6 15.8 20.7 26.6 31.5 39.9 48.2 62.3 75.6 93.1 123.8 146.3 180.4 216.1

Rated current (A) 1.5 2.5 3.8 5.3 9.0 14 19 25 32 38 48 58 75 91 112 149 176 217 260

Heatloss W

Losses at 70% load 64 76 102 127 179 242 312 435 575 698 820 1100 1345 1625 1975 2675 3375 3900 4670Losses at 100% load 70 88 125 160 235 325 425 600 800 975 1150 1550 1900 2300 2800 3800 4800 5550 6650

Efficiency at rated output 85.1 89.5 92.3 93.2 94.0 64.4 94.6 94.8 94.9 95.0 95.0 95.0 95.1 95.1 95.1 95.2 95.2 95.2 95.2Cooling method Forced-air-cooling

Three-phase 200 V class

Three-phase 400 V class

Voltage Model 3G3AX-9

Specifications

Permanent Peak (5s max) Minimumconnectable resistor (Ohms)Current (A) Brake power (KVA) Current (A) Brake power (KVA)

200VBCR2035090-TE 35 13 90 32 4BCR2070130-TE 70 25 130 47 2.8

400V

BCR4015045-TE 15 11 45 33 16BCR4017068-TE 17 13 68 51 11BCR4035090-TE 35 26 90 67 8.5BCR4070130-TE 70 52 130 97 5.5BCR4090240-TE 90 67 240 180 3.2

Braking Unit

173G3RX-V1

3-phase 200 V class 3-phase 400 V class

Max. applicable motor output Model 3G3AX-9 Current value Inductance mH Max. applicable motor output Model 3G3AX-9 Current value Inductance mH

0.4to1.5kW(1/8to2HP) RAI02800100-DE 10.0A 2.8 0.4to1.5kW(1/2to2HP) RAI07700050-DE 5.0A 7.72.2to3.7kW(3to5HP) RAI00880200-DE 20.0A 0.88 2.2to3.7kW(3to5HP) RAI03500100-DE 10.0A 3.5

5.5to7.5kW(71/2to10HP) RAI00350335-DE 33.5A 0.35 5.5to7.5kW(71/2to10HP) RAI01300170-DE 17.0A 1.311to15kW(15to20HP) RAI00180670-DE 67.0A 0.18 11to15kW(15to20HP) RAI00740335-DE 33.5A 0.7418.5to22kW(25to30HP) RAI00091000-DE 100.0A 0.09 18.5to22kW(25to30HP) RAI00360500-DE 50.0A 0.3630to37kW(40to50HP) RAI00071550-DE 155.0A 0.07 30to37kW(40to50HP) RAI00290780-DE 78.0A 0.2945to55kW(60to75HP) RAI00042300-DE 230.0A 0.04 45to55kW(60to75HP) RAI00191150-DE 115.0A 0.19

Input AC Reactor

MCCBPower supply

AC reactor 3G3RX

R/L1U

V

W

X

Y

Z

S/L2

T/L3

200 V class 400 V class

Max. applicable motor output Model 3G3AX-9 Current value Inductance mH Max. applicable motor output Model 3G3AX-9Current value

Inductance mH

0.4kW(1/2HP) RC10700032-DE 3.2A 10.7 0.4kW(1/2HP) RC43000020-DE 2.0A 430.75kW(1HP) RC06750061-DE 6.1A 6.75 0.75kW(1HP) RC27000030-DE 3.0A 271.5kW(2HP) RC03510093-DE 9.3A 3.51 1.5kW(2HP) RC14000047-DE 4.7A 142.2kW(3HP) RC02510138-DE 13.8A 2.51 2.2kW(3HP) RC10100069-DE 6.9A 10.13.7kW(5HP) RC01600223-DE 22.3A 1.6 3.7kW(5HP) RC06400116-DE 11.6A 6.4

5.5kW(71/2HP) RC01110309-DE 30.9A 1.11 5.5kW(71/2HP) RC04410167-DE 16.7A 4.417.5kW(10HP) RC00840437-DE 43.7A 0.84 7.5kW(10HP) RC03350219-DE 21.9A 3.3511.0kW(15HP) RC00590614-DE 61.4A 0.59 11.0kW(15HP) RC02330307-DE 30.7A 2.3315.0kW(20HP) RC00440859-DE 85.9A 0.44 15.0kW(20HP) RC01750430-DE 43.0A 1.75

18.5to22kW(25-30HP) RC00301275-DE 127.5A 0.3 18.5to22kW(25-30HP) RC01200644-DE 64.4A 1.230kW(40HP) RC00231662-DE 166.2A 0.23 30kW(40HP) RC00920797-DE 79.7A 0.9237kW(50HP) RC00192015-DE 201.5A 0.19 37kW(50HP) RC00741042-DE 104.2A 0.7445kW(60HP) RC00162500-DE 250.0A 0.16 45kW(60HP) RC00611236-DE 123.6A 0.6155kW(75HP) RC00133057-DE 305.7A 0.13 55kW(75HP) RC00501529-DE 152.9A 0.5

200 V class 400 V class

Max. applicable motor output Model 3G3AX-9 Current value Inductance mH Max. applicable motor output Model 3G3AX-9Current value

Inductance mH

0.4kW(1/2HP) RAO11500026-DE 2.6A 11.5 0.4to1.5kW(1/2to2HP) RAO16300038-DE 3.8A 16.30.75kW(1HP) RAO07600042-DE 4.2A 7.6 2.2kW(3HP) RAO11800053-DE 5.3A 11.81.5kW(2HP) RAO04100075-DE 7.5A 4.1 4.0kW(5HP) RAO07300080-DE 8A 7.32.2kW(3HP) RAO03000105-DE 10.5A 3 5.5kW(71/2HP) RAO04600110-DE 11A 4.63.7kW(5HP) RAO01830160-DE 16A 1.83 7.5kW(10HP) RAO03600160-DE 16A 3.6

5.5kW(71/2HP) RAO01150220-DE 22A 1.15 11kW(15HP) RAO02500220-DE 22A 2.57.5kW(10HP) RAO00950320-DE 32A 0.95 15kW(20HP) RAO02500220-DE 32A 211kW(15HP) RAO00630430-DE 34A 0.6315kW(20HP) RAO00490640-DE 64A 0.49

DC Reactor

Output AC Reactor

Powersupply

3G3RX

DC reactor

R/L1

PD/+1 P/+

MCCB

S/L2

T/L3

Reactors

18 Frequency Inverters

Choke

Remote Operatorwith 2-line LCD display

Remote Operator Extension Cable

Output AC Reactor

Braking chopper

Braking Resistor

Option units

ACTIVEPOWER

OVERCURRENT

BUSS

BUSS

+

R R

BC...CH O P PE R

DANGERHIGH VOLTAGE !

RJ45 - USB CableSoftware:CX-Drive in CX-OneMCCB

Filter

Input AC Reactor

Motor

Ground

Power Supply

DC Reactor

C22

R52C24PE

C16

U11

U8R6

C26

C28

JP3

U6

U7

T1

U9++

R15

R15R25

R15R20R30

R7

R5C5

R21

U14

C17R14

R28

RR11

JP1

C1

U10

C3

R5R1 R2

R36R3C2

1

R35

R70

R120

R75

R78

R114C2

2+

+

U1+

C35

R99U12R9

5

R39R40R57

R56

D6

R6

U15

R54

R55

R8

TR2 11R1

1R1

10R1

07

R113

TR1

C13

U13

C10

SI-N

CODE No.

U17

73600-C0210

JP5 JP6

RT4

R10R10 R105

R102 C12

C11R94R97

R96

C20

R95

C39

R131

Y1

U10

C33

3G3RX-V1

Ordering Information

SpecificationsModel

3G3RX-9-V1

SpecificationsModel

3G3RX-9-V1Voltage class

Max. motor capacity Rated current Voltage class

Max. motor capacity Rated current

kW HP A kW HP A

Three-phase200V

0.4 1/2 3.0 A2004

Three-phase400V

0.4 1/2 1.5 A4004

0.75 1 5.0 A2007 0.75 1 2.5 A4007

1.5 2 7.5 A2015 1.5 2 3.8 A4015

2.2 3 10.5 A2022 2.2 3 5.3 A4022

3.7 5 16.5 A2037 4.0 5 9.0 A4037

5.5 71/2 24 A2055 5.5 71/2 14 A4055

7.5 10 32 A2075 7.5 10 19 A4075

11 15 46 A2110 11 15 25 A4110

15 20 64 A2150 15 20 32 A4150

18.5 25 76 A2185 18.5 25 38 A4185

22 30 95 A2220 22 30 48 A4220

30 40 121 A2300 30 40 58 A4300

37 50 145 A2370 37 50 75 A4370

45 60 182 A2450 45 60 91 A4450

55 75 200 A2550 55 75 112 A4550

– – – – 75 100 149 B4750

– – – – 90 125 176 B4900

– – – – 110 150 217 B411K

– – – – 132 200 260 B413K

3G3RX-V1 AC Drives

193G3RX-V1

3-Phase 200 VAC 3-Phase 400 VAC

Model 3G3RX-9-V1 Model 3G3AX-9Rated current

(A)Leakage

Nom / MaxWeight

(kg) Model 3G3RX-9-V1 Model 3G3AX-9Rated current

(A)Leakage

Nom / MaxWeight

(kg)

A2004/A2007/A2015/A2022/A2037 FIR2018-RE 18 0.7/40mA 2.0 A4004/A4007/A4015/

A4022/A4037 FIR3010-RE 10 0.3/40mA 1.9

A2055/A2075/A2110 FIR2053-RE 53 0.7/40mA 2.5 A4055/A4075/A4110 FIR3030-RE 30 0.3/40mA 2.2A2150/A2185/A2220 FIR2110-RE 110 1.2/70mA 8.0 A4150/A4185/A4220 FIR3053-RE 53 0.8/70mA 4.5

A2300 FIR2145-RE 145 1.2/70mA 8.6 A4300 FIR3064-RE 64 3/160mA 7.0

A2370/A2450 FIR3250-RE 250 6/300mA 13.0 A4370 FIR3100-RE 100 2/130mA 8.0

A2550 FIR3320-RE 320 6/300mA 13.2 A4450/A4550 FIR3130-RE 130 2/130mA 8.6

–A4750/A4900 FIR3250-RE 250 10/500mA 13.0A411K/A413K FIR3320-RE 320 10/500mA 13.2

Rasmi Line Filters

3-Phase 200 VAC 3-Phase 400 VAC

Inverter Model 3G3RX-9-V1 AC Reactor Model Inverter Model 3G3RX-9-V1 AC Reactor Model

A2004 / A2007 / A2015 3G3AX-RAI02800100-DE A4004 / A4007 / A4015 3G3AX-RAI07700050-DE

A2022 / A2037 3G3AX-RAI00880200-DE A4022 / A4037 3G3AX-RAI03500100-DE

A2055 / A2075 3G3AX-RAI00350335-DE A4055 / A4075 3G3AX-RAI01300170-DE

A2110 / A2150 3G3AX-RAI00180670-DE A4110 / A4150 3G3AX-RAI00740335-DE

A2185 / A2220 3G3AX-RAI00091000-DE A4185 / A4220 3G3AX-RAI00360500-DE

A2300 / A2370 3G3AX-RAI00071550-DE A4300 / A4370 3G3AX-RAI00290780-DE

A2450 / A2550 3G3AX-RAI00042300-DE A4450 / A4550 3G3AX-RAI00191150-DE

3-Phase 200 VAC 3-Phase 400 VAC

Inverter Model 3G3RX-9-V1 DC Reactor Model Inverter Model 3G3RX-9-V1 DC Reactor Model

A2004 3G3AX-RC10700032-DE A4004 3G3AX-RC43000020-DEA2007 3G3AX-RC06750061-DE A4007 3G3AX-RC27000030-DEA2015 3G3AX-RC03510093-DE A4015 3G3AX-RC14000047-DEA2022 3G3AX-RC02510138-DE A4022 3G3AX-RC10100069-DEA2037 3G3AX-RC01600223-DE A4037 3G3AX-RC06400116-DEA2055 3G3AX-RC01110309-DE A4055 3G3AX-RC04410167-DEA2075 3G3AX-RC00840437-DE A4075 3G3AX-RC03350219-DEA2110 3G3AX-RC00590614-DE A4110 3G3AX-RC02330307-DEA2150 3G3AX-RC00440859-DE A4150 3G3AX-RC01750430-DE

A2185/A2220 3G3AX-RC00301275-DE A4185/A4220 3G3AX-RC01200644-DEA2300 3G3AX-RC00231662-DE A4300 3G3AX-RC00920797-DEA2370 3G3AX-RC00192015-DE A4370 3G3AX-RC00741042-DEA2450 3G3AX-RC00162500-DE A4450 3G3AX-RC00611236-DEA2550 3G3AX-RC00133057-DE A4550 3G3AX-RC00501529-DE

3-Phase 200 VAC 3-Phase 400 VAC

Inverter Model 3G3RX-9-V1 Output AC Reactor Model Inverter Model 3G3RX-9-V1 Output AC Reactor Model

A2004 3G3AX-RAO11500026-DEA4004/A4007/A4015 3G3AX-RAO16300038-DEA2007 3G3AX-RAO07600042-DE

A2015 3G3AX-RAO04100075-DEA2022 3G3AX-RAO03000105-DE A4022 3G3AX-RAO11800053-DEA2037 3G3AX-RAO01830160-DE A4037 3G3AX-RAO07300080-DEA2055 3G3AX-RAO01150220-DE A4055 3G3AX-RAO04600110-DEA2075 3G3AX-RAO00950320-DE A4075 3G3AX-RAO03600160-DEA2110 3G3AX-RAO00630430-DE A4110 3G3AX-RAO02500220-DEA2150 3G3AX-RAO00490640-DE A4150 3G3AX-RAO02000320-DE

Input AC Reactors

DC Reactors

Model Diameter (mm) Description

3G3AX-FER2102-RE 21 For 2.2 kW (3 HP) motors or below

3G3AX-FER2515-RE 25 For 15 kW (20 HP) motors or below

3G3AX-FER5045-RE 50 For 45 kW (60 HP) motors or below

3G3AX-FER6055-RE 60 For 55 kW (75 HP) motors or above

Chokes

Output AC Reactor

Ordering Information

20 Frequency Inverters

Ordering Information

Types Model Description Functions

Enc

od

er

feed

bac

k

3G3AX-PG01 PG speed controller option card

Phase A,B and Z pulse (differential pulse) inputs (RS-422)Pulse train position command input (RS-422)Pulse monitor output (RS-422)PG frequency range: 100 kHz max

Co

mm

unic

atio

no

ptio

n b

oar

d SJ-DN DeviceNet option card Used for running or stopping the inverter or give frequency reference through DeviceNet

SJ-PB Profibus option card Used for running or stopping the inverter or give frequency reference through Profibus

Digital

inpu

t

3G3AX-DI01 Digitalinputoptioncard Allowstosetfrequencyreferencefromadigitalselection

Option Boards

Single-/Three-Phase 200 V class Braking resistor unit

Model 3G3RX-9-V1

Max. motor capacity

Braking Unit Model Connectable

min. resistance Ω

Inverter mounted type(3%ED, 10 sec max) Braking

torque %

Inverter mounted type(10%ED, 10 sec max) Braking

torque %kW HP 3G3AX-BCR9 Model 3G3AX-9

Resistance Ω Model 3G3AX-9

Resistance Ω

A2004 0.4 1/2

Built-in

50 REM00K1200-IE 200180 REM00K1200-IE 200 180

A2007 0.75 1 100 REM00K2070-IE 70 200

A2015 1.5 235

REM00K2070-IE 70140 REM00K4075-IE 75 130

A2022 2.2 3 90 REM00K4035-IE 35 180

A2037 3.7 5 REM00K4075-IE 75 50 REM00K6035-IE 35 100

A2055 5.5 71/2 16REM00K4035-IE 35

75 REM00K9020-IE 20 150

A2075 7.5 1010

55 REM01K9017-IE 17 110

A2110 11 15 REM00K6035-IE 35 40 REM02K1017-IE 17 75

A2150 15 207.5

REM00K9017-IE 17 55 REM03K5010-IE 10 95

A2185 18.5 25REM03K5010-IE 10

75REM19K0008-IE 8

95

A2220 22 30 5 65 80

A2300 30 402035090-TE 4

- -REM19K0006-IE

6 80

A2370 37 50 - - 6 60

A2450 45 602070130-TE 2.8

- -2 x REM19K0006-IE

3 105

A2550 55 75 - - 3 85

Braking Unit, Braking Resistor Unit

Types Model Description Functions

Dig

ital

op

erat

or 3G3AX-OP05 LCD remote operator 2 Line LCD remote operator with copy function, cable length max. 3m.

3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator

Acc

esso

ries

3G3AX-CONV1 USB converter / USB cable RJ45 to USB connection cable

Accessories

213G3RX-V1

Ordering Information

Specifications are subject to change without notice.

Braking Unit, Braking Resistor Unit

Item Description Functions

CX-Drive AC Drive/Servo Programming softwareSet, transfer and compare parameters; perform test runs and adjustment; perform monitoring and data tracing for Omron inverters and servos included in CX-One software.

CX-One All-in-one Automation softwareProgram, configure and simulate operations for PLCs, HMIs, networks, motion control systems, temperature and process controllers.

Computer Software

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Note: Software runs on the following OS: Windows 2000 (Service Pack 3a or higher), XP, Vista or Windows 7.

Three-phase 400 V class Braking resistor unit

Model 3G3RX- -V1

Max. motor capacity

Braking Unit Model Connectable

min. resistance Ω

Inverter mounted type(3%ED, 10 sec max)

Brakingtorque %

Inverter mounted type(10%ED, 10 sec max)

Brakingtorque %

kW HP 3G3AX-BCR Model 3G3AX-Resistance

Ω Model 3G3AX-Resistance

Ω

A4004 0.4 1/2

Built-in

100

REM00K1400-IE 400200

REM00K1400-IE 400200

A4007 0.75 1 200 200

A4015 1.5 2 REM00K1200-IE 200 190 REM00K2200-IE 200 190

A4022 2.2 3 REM00K2200-IE 200 130 REM00K5120-IE 120 200

A4037 3.7 570

REM00K2120-IE 120 120 REM00K6100-IE 100 140

A4055 5.5 7 1/2REM00K4075-IE 75

140 REM00K9070-IE 70 150

A4075 7.5 1035

100 REM01K9070-IE 70 110

A4110 11 15 REM00K6100-IE 100 50 REM02K1070-IE 70 75

A4150 15 2024

REM00K9070-IE 70 55 REM03K5035-IE 35 110

A4185 18.5 25REM03K5035-IE 35

90REM19K0030-IE 30

100

A4220 22 30 20 75 85

A4300 30 40 4015045-TE 16 REM19K0020-IE 20 95

A4370 37 504017068-TE 11 REM38K0012-IE 15

125

A4450 45 60 100

A4550 55 754035090-TE 8.5

2 x REM19K0020-IE 10 100

B4750 75 100 3 x REM19K0030-IE 10 75

B4900 90 125 4070130-TE 5.5 2 x REM38K0012-IE 6 105

B411K 110 1504090240-TE 3.2 3 x REM38K0012-IE 4

125

B413K 132 200 105

22 Frequency Inverters

233G3RX-V1

OMRON CANADA, INC. • HEAD OFFICEToronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com

OMRON ELECTRONICS DE MEXICO • HEAD OFFICEMéxico DF • 52.55.59.01.43.00 • 01-800-226-6766 • [email protected]

OMRON ELECTRONICS DE MEXICO • SALES OFFICEApodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • [email protected]

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICESão Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON ARGENTINA • SALES OFFICECono Sur • 54.11.4783.5300

OMRON CHILE • SALES OFFICESantiago • 56.9.9917.3920

OTHER OMRON LATIN AMERICA SALES54.11.4783.5300

Authorized Distributor:

I29I-E-02 Note: Specifications are subject to change. © 2015 Omron Electronics LLC Printed in U.S.A.

Printed on recycled paper.

Automation Control Systems• Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software

Drives & Motion Controls • Servo & AC Drives • Motion Controllers & Encoders

Temperature & Process Controllers • Single and Multi-loop Controllers

Sensors & Vision• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors• Amplified Photomicrosensors • Measurement Sensors• Ultrasonic Sensors • Vision Sensors

Industrial Components • RFID/Code Readers • Relays • Pushbuttons & Indicators • Limit and Basic Switches • Timers • Counters • Metering Devices • Power Supplies

Safety • Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety Controllers • Light Curtains • Safety Relays • Safety Interlock Switches

OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu


Recommended