Strategic Power Solutions ® MF Series 05 / 06 / 10 / 20 / 30KVA 1:1 Phase PF: 0.9 Online UPS 1Phase Out Server and Others Networking Equipments Control Panel = True Online Double Conversion with DSP Controlled Pure Wave Sine Wave with PWM technology = IGBT, Both Inverter & Rectifier = Input Current Harmonic: <5% = Optimization Battery Group, The Quantity of Battery: 16/18/20 Pisces = High Input Power Factor 0.99 = High Output Power Factor 0.9 = Wide Input Voltage Range: 120~280V AC = Wide Input Frequency Range (50Hz: 45~55Hz/60Hz: 54~66Hz) = Generator Compatibility = Support Economic Operation (ECO) Mode = Self-Testing while UPS Startup = Optional Parallel upto 4 units = Static Bypass, Manual Bypass and Cold Start = Auto Start and cold start function = Isolation Transformer Compatible Application: Features: 1. Fan 2. Input Switch 3. Output Switch 4. Maintenance Switch 5. Terminal 6. Com Port 7. USB Port 8. Parallel Port 9. EPO 10. Intelligent Slot / SNMP(Optional) Rear Panel 1 1 1 2 2 2 3 3 5 5 5 4 4 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 4 R-85001546 IS 16242 (Part 1)/ IEC 62040-1 ISO 9001 ISO 14001 ISO 27001 OHSAS 18001
Transcript
Page 1: Online UPS 1Phase Out Series 5-30KVA Catalogue.pdf · 2020. 3. 31. · Strategic Power Solutions ® MF Series 05 / 06 / 10 / 20 / 30KVA 1:1 Phase PF: 0.9 Online UPS 1Phase Out Server

Strategic Power Solutions

®

MF Series05 / 06 / 10 / 20 / 30KVA1:1 Phase PF: 0.9

Online UPS 1Phase Out

Server and Others Networking Equipments

Control Panel

= True Online Double Conversion with DSP Controlled

Pure Wave Sine Wave with PWM technology= IGBT, Both Inverter & Rectifier

= Input Current Harmonic: <5%

= Optimization Battery Group, The Quantity of Battery:

16/18/20 Pisces

= High Input Power Factor 0.99

= High Output Power Factor 0.9

= Wide Input Voltage Range: 120~280V AC

= Wide Input Frequency Range (50Hz: 45~55Hz/60Hz:

54~66Hz)

= Generator Compatibility

= Support Economic Operation (ECO) Mode = Self-Testing while UPS Startup

= Optional Parallel upto 4 units

= Static Bypass, Manual Bypass and Cold Start

= Auto Start and cold start function

= Isolation Transformer Compatible

Application:

Features:1. Fan2. Input Switch3. Output Switch4. Maintenance Switch5. Terminal6. Com Port7. USB Port8. Parallel Port9. EPO10. Intelligent Slot / SNMP(Optional)

Rear Panel

1

11

2

2

2 3

3

55

5

44

6

6

6

7

7

7

8

8

8

9

9

9

10

10

10

4

R-85001546

IS 16242 (Part 1)/IEC 62040-1

ISO 9001 ISO 14001 ISO 27001OHSAS 18001

Page 2: Online UPS 1Phase Out Series 5-30KVA Catalogue.pdf · 2020. 3. 31. · Strategic Power Solutions ® MF Series 05 / 06 / 10 / 20 / 30KVA 1:1 Phase PF: 0.9 Online UPS 1Phase Out Server

Strategic Power Solutions

®

*Specifications are subject to change without prior notice.

Best Power Equipments (I) Pvt. Ltd.Corporate Office: G-240, Sector-63, Distt. Gautam Buddh Nagar, Noida-201307 UPRegistered Office: 812A, Shakuntala Building, 59, Nehru Place, New Delhi-110019PH: +91 120 4637000-0029 | Mobile: +91 9311995859 | Email: [email protected]@bpeeservices.com | Toll Free: 1800 103 1247 | Website: www.bpee.com

Strategic Power Solutions

®

Technical Specifications of MF Series 5~30KVA

MODEL MF1105L16 MF1106L16 MF1106B16 MF1110L16 MF1110B16 MF3110L16 MF3120L16 MF3130L16

Capacity (KVA) 05 06 10 20 30

INPUT

Nominal Voltage 220V / 230V / 240V AC (L+N+PE) 380V/400V/415V AC(3Ph+N+PE)

Operating Voltage Range 100V~300V AC Load Dependent 277V~480V AC Load Dependent

Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)

Power Factor ≥0.99

BypassVoltage ± 20% (Configurable)

Frequency ± 10% (Configurable)

ECO Range Same as the Bypass, can be configured

Generator Input Competible

OUTPUT

Rated Voltage 220V / 230V / 240V AC L+N+PE (Configurable)

Power Factor 0.8 (Standard) 0.9 (Optional)

Voltage Regulation ±1%

Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.01% Hz Battery Mode

Crest Factor 3:1

Overload ≤ 110% for 15Mins, ≤ 125% for 10 Mins, ≤ 150% for 60 Sec, ≥ 150% for 200ms

Harmonic Distortion (THDv) ≤2% with Linear Load, ≤5% with Non Linear Load

Efficiency AC-AC Mode: ≥ 90% , DC-AC Mode: ≥95%, ECO Mode: 99%

BATTERY

Battery Voltage 192V DC / 216V & 240V DC (Configurable)

Typical Recharge Time 6~8 Hours to 90% of full Capacity

Charge Current 6A 10A

SYSTEM FEATURES

IP Protection IP 20

Transfer Time Zero

EPO / ECO / CVCF/Slew Rate Shutdown UPS Immediately / ECO and CVCF Mode can be Configurable ; Slew rate: 1Hz/Sec

Alarm / ProtectionShort Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC

BUS Under / Over Voltage and Battery low, Inv Over/Under Voltage, Surge Protection

LED Display Line Mode, Backup Mode, ECO Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault

LCD DisplayInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage,

Temperature & Remaining Battery Backup Time, Load VA/W, Load and Battery Barograph

INVIRONMENTAL

Temperature Operating: 0~45°C, Storage: -10ºC ~ 55ºC

Humidity / Altitude 0~95% RH Non-condersing / <1500 M

Noise < 55dB @ 1meter distance

PHYSICAL

Dimension WxDxH (mm) 220x481x438 250x500x650 220x481x438 250x500x650 250x502x616

Net Weight (Kg) 17 18 65 20 70 35 37 40

STANDARDS

Quality ISO 9000, ISO 14001, OHSAS 18001, ISO 27001, BIS, RoHS

Safety IEC/EN62040-1

EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE

COMMUNICATION INTERFACE

Standard RS-232

Optional SNMP / ModBus / Dry Contact / USB / RS-485

Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000

< 60dB @ 1meter distance


Recommended