+ All Categories
Home > Documents > ONT Product Information Manual.pdf

ONT Product Information Manual.pdf

Date post: 09-Nov-2015
Category:
Upload: hishamuddin-johari
View: 128 times
Download: 13 times
Share this document with a friend
Popular Tags:
360
Alcatel-Lucent - Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. Copyright © 2008 Alcatel-Lucent. All rights reserved. Alcatel-Lucent 7342 INTELLIGENT SERVICES ACCESS MANAGER FIBER TO THE USER ONT R04.05.00 ONT PRODUCT INFORMATION MANUAL 3FE 51455 AAAA TCZZA Edition 01
Transcript
  • Alcatel-Lucent - ProprietaryThis document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements.Copyright 2008 Alcatel-Lucent. All rights reserved.

    Alcatel-Lucent 7342INTELLIGENT SERVICES ACCESS MANAGER FIBER TO THE USERONT R04.05.00O N T P R O D U C T I N F O R M A T I O N M A N U A L

    3FE 51455 AAAA TCZZA Edition 01

  • When printed by Alcatel-Lucent, this document is printed on recycled paper.

    Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.

    Copyright 2008 Alcatel-Lucent.All rights reserved.

    Disclaimers

    Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications.This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products.However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers.This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail.

  • Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 iii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Preface

    This preface provides general information about the documentation set for the 7342 ISAM Fiber to the User (7342 ISAM FTTU) optical network terminals (ONTs).

    Scope

    This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, and software installation procedures for the current release.

    Audience

    This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7342 ISAM FTTU ONTs.

    Required knowledge

    The reader must be familiar with general telecommunications principles.

    Assistance and ordering phone numbers

    Alcatel-Lucent provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: www1.alcatel-lucent.com/comps/pages/carrier_support.jhtml. For technical assistance within North America, call 1-888-252-2832. If calling from outside North America, call 1-613-784-6100.

  • Preface

    iv January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    For ordering information, contact your Alcatel-Lucent sales representative.

    Alcatel-Lucent quality processes

    Alcatel-Lucents 7342 ISAM Fiber to the User (7342 ISAM FTTU) optical network terminals (ONTs) manufacturing, testing, and inspecting practices are in compliance with GR-1252-CORE and TL 9000 requirements. These requirements are documented in the Operations Quality Plan 8BD000234204QRZZA and the Alcatel-Lucent North American Quality Manual 8BD000010000QRZZA.The quality plans and practices adequately ensure that technical requirements and customer end-point requirements are met. The customer or its representatives may be allowed to perform on-site quality surveillance audits, as agreed upon during contract negotiations.

    Safety information

    For ETSI and ANSI safety information, see the appropriate safety guidelines chapters.

    Special information

    The following are examples of how special information is presented in this document.

    Procedures with options or substepsWhen there are options in a procedure, they are identified by letters. When there are required substeps in a procedure, they are identified by roman numerals.

    Danger Danger indicates that the described activity or situation may result in serious personal injury or death; for example, high voltage or electric shock hazards.

    Warning Warning indicates that the described activity or situation may, or will, cause equipment damage or serious performance problems.

    Caution Caution indicates that the described activity or situation may, or will, cause service interruption.

    Note A note provides information that is, or may be, of special interest.

  • Preface

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 v3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Procedure 1 Example of options in a procedure

    At step 1, you can choose option a or b. At step 2, you must do what the step indicates.

    1 This step offers two options. You must choose one of the following:

    a This is one option.

    b This is another option.

    2 You must perform this step.

    Procedure 2 Example of required substeps in a procedure

    At step 1, you must perform a series of substeps within a step. At step 2, you must do what the step indicates.

    1 This step has a series of substeps that you must perform to complete the step. You must perform the following substeps:

    i This is the first substep.

    ii This is the second substep.

    iii This is the third substep.

    2 You must perform this step.

  • Preface

    vi January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 vii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    ANSI ONT safety guidelines

    This chapter provides information about the mandatory regulations that govern the installation and operation of the 7342 ISAM FTTU optical network terminals (ONTs).

    Safety instructions

    This section describes the safety instructions that are provided in the 7342 ISAM FTTU ONT customer documentation and on the equipment.

    Safety instruction boxes

    The safety instruction boxes are provided in the 7342 ISAM FTTU ONT customer documentation. Observe the instructions to meet safety requirements.

    The following is an example of the Danger box.

    The Danger box indicates that the described activity or situation may pose a threat to personal safety. It calls attention to a situation or procedure which, if not correctly performed or adhered to, may result in death or serious physical harm.

    Do not proceed beyond a Danger box until the indicated conditions are fully understood and met.

    The following is an example of the Warning box.

    Danger Possibility of personal injury.

  • ANSI ONT safety guidelines

    viii January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    The Warning box indicates that the described activity or situation may, or will, cause equipment damage, loss of data, or serious performance problems. It identifies a possible equipment-damaging situation or provides essential information to avoid the degradation of system operations or data.

    Do not proceed beyond a warning until the indicated conditions are fully understood and met.

    The following is an example of the Caution box.

    The Caution box indicates that the described activity or situation may, or will, cause service interruption.

    Do not proceed beyond a caution until the indicated conditions are fully understood and met.

    The following is an example of the Note box.

    The Note box provides information that assists the personnel working with 7342 ISAM FTTU ONTs. It does not provide safety-related instructions.

    Safety-related labels

    The ONT equipment is labeled with specific safety compliance information and instructions that are related to a variant of the ONT. Observe the instructions on the safety labels.

    Table 1 provides examples of the text in the various ONT safety labels.

    Table 1 Safety labels

    Warning 1 Possibility of equipment damage.

    Warning 2 Possibility of data loss.

    Caution 1 Possibility of service interruption.

    Caution 2 Service interruption.

    Note Information of special interest.

    Description Label text

    UL compliance Communication service equipment US listed. Type 3R enclosure - Rainproof.

    TUV compliance Type 3R enclosure - Rainproof.

    ESD warning Caution: This assembly contains electrostatic sensitive device.

    (1 of 2)

  • ANSI ONT safety guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 ix3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Figure 1 shows a sample safety label on the ONT equipment.

    Figure 1 Safety label on the ONT equipment

    Safety standards compliance

    This section describes the ONT compliance with North American safety standards.

    Laser classification Class 1 laser product

    Laser product compliance This laser product conforms to all applicable standards of 21 CFR 1040.10 at date of manufacture.

    Laser product compliance Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice no. 50, dated July 26, 2001.

    FCC standards compliance Tested to comply with FCC standards for home or office use.

    Operation conditions This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

    Canadian standard compliance (modular ONT)

    This Class A digital apparatus complies with Canadian ICES-003.

    Canadian standard compliance (outdoor ONT)

    This Class B digital apparatus complies with Canadian ICES-003.

    CE marking There are various CE symbols for CE compliance.

    Description Label text

    (2 of 2)

    18533

    This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation.

    This Class A digital apparatus complies with Canadian ICES-003. Cet appareilnumerique de la class A est conforme a la norme NMB-003 du Canada

    Tested to Complywith FCC Standards

    FOR HOME OR OFFICE USECOMMUNICATION SERVICE EQUIPMENTUS LISTED27FYType 3R Enclosure - Rainproof

    CAUTIONThis Assembly Contains Electrostatic Sensitive Devices

    c

  • ANSI ONT safety guidelines

    x January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    EMC, EMI, and ESD standards compliance

    The ONT equipment complies with the following requirements:

    Federal Communications Commission (FCC) CFR 47, Part 15, Subpart B, Class A requirements for OLT equipment

    GR-1089-CORE requirements, including: Section 3 Electromagnetic Interference, Emissions Radiated and Conducted Section 3 Immunity, Radiated and Conducted Section 2 ESD Discharge Immunity: System Level Electrostatic Discharge and EFT

    Immunity: Electrically Fast Transients

    Equipment safety standard compliance

    The ONT equipment complies with the requirements of UL60950-1, Safety of Information Technology Equipment.

    Environmental standards compliance

    The ONT equipment complies with the following standards:

    GR-63-CORE (NEBS): requirements related to operating, storage, humidity, altitude, earthquake, office vibration, transportation and handling, fire resistance and spread, airborne contaminants, illumination, and acoustic noise

    GR-487-CORE: requirements related to rain, chemical, sand, and dust GR-487 R3-82: requirements related to condensation GR-3108: Requirements for Network Equipment in the Outside Plant (OSP) TP76200: Common Systems Equipment Interconnections Standards

    Laser product standards compliance

    The ONT equipment complies with 21 CFR 1040.10 and 21 CFR 1040.11, Laser Notice No. 50, the regulations for lasers and laser products by the U.S. Center for Devices and Radiological Health (CDRH) of the Food and Drug Administration (FDA).

    Resistibility requirements compliance

    The ONT equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to overvoltage and overcurrents.

    Electrical safety guidelines

    This section provides the electrical safety guidelines for the ONT equipment.

  • ANSI ONT safety guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xi3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Power supplies

    The use of any non-Alcatel-Lucent approved power supplies or power adaptors is not supported or endorsed by Alcatel-Lucent. Such use will void any warranty or support contract with Alcatel-Lucent. Such use greatly increases the danger of damage to equipment or property.

    Cabling

    The following are the guidelines regarding cables used for the ONT equipment:

    Use only cables approved by the relevant national electrical code. Use cables suitable for outdoor use for outdoor installation of ONTs. The ONTs have been evaluated for use with external wiring that may not exceed

    140 ft (43 m) in reach. However, the power cable must not exceed 100 ft (31 m).

    Protective earth

    Earthing and bonding of the ONTs must comply with the requirements of NEC article 250 or local electrical codes.

    ESD safety guidelines

    The ONT equipment is sensitive to ESD. Operations personnel must observe the following ESD instructions when they handle the ONT equipment.

    During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD.

    Alcatel-Lucent recommends that you prepare the site before you install the ONT equipment. In addition, you must control relative humidity, use static dissipating material for furniture or flooring, and restrict the use of air conditioning.

    Laser safety guidelines

    Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system.

    Observe the following warnings when you perform installation, operations, and maintenance tasks on the ONT equipment.

    Note The ONTs comply with the U.S. National Electrical Code. However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards.

    Caution This equipment is ESD sensitive. Proper ESD protections should be used when entering the TELCO Access portion of the ONT.

  • ANSI ONT safety guidelines

    xii January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    Observe the following danger for a laser hazard. Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules.

    Laser warning labels

    The following figures show the labels related to laser product, classification and warning.

    Figure 2 shows the laser product label.

    Figure 2 Laser product label

    Figure 3 shows the laser classification label.

    Figure 3 Laser classification label

    Danger There may be laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to beam.

    Danger Possibility of equipment damage. Risk of eye damage by laser radiation.

    18455

    LASER CLASSE 1CLASE 1 DEL LASER

    CLASS 1 LASER PRODUCT

    18992

  • ANSI ONT safety guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xiii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Figure 4 shows the laser warning label and an explanatory label for laser products. The explanatory label provides the following information:

    a warning that calls attention to the invisible laser radiation an instruction against staring into the beam or view directly with optical

    instruments wavelength normal output power maximum output power

    Figure 4 Laser warning labels

    Laser classification

    The ONT is classified as a Class 1 laser product based on its transmit optical output.

    For Class 1 laser products, lasers are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing.

    Figure 5 shows a sample laser product safety label on the ONT equipment.

    INVISIBLE LASER RADIATIONDO NOT STARE INTO BEAMOR VIEW DIRECTLY WITHOPTICAL INSTRUMENTSWavelength(s): xxxx nmNormal output power: xx m WMax output power: yyy m W

    Laser Warning Label Laser Warning Label

    CLASS 1 LASER PRODUCT

    INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLEWHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM.

    RAYONNEMENT LASER CLASSE 1RAYONNEMENT LASER INVISIBLE

    EVITER TOUTE EXPOSITION AU FAISCEAUNE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE

    CLASE 1 DEL LASERRADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION ALRAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO

    Laser Warning Label18993

    '

  • ANSI ONT safety guidelines

    xiv January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    Figure 5 Laser product safety label on the ONT equipment

    Transmit optical output

    The maximum transmit optical output of an ONT is +5 dBm.

    Normal laser operation

    In normal operation, fiber cable laser radiation is always off until it receives signal from the line terminal card.

    Operating personnel must observe the instructions on the laser explanatory label before plugging in the optical module.

    Location class

    Use cable supports and guides to protect the receptacles from strain.

    Environmental requirements

    The outdoor and modular ONTs must not be installed at a location where the maximum ambient temperature exceeds 60C (140F), with no solar loading, and the minimum ambient temperature does not go below -40C (-40F).The indoor ONT must not be installed at a location where the ambient temperature range exceeds 0C (32F) to 40C (104F) with no solar loading.

    CLASS 1 LASER PRODUCTTHIS LASER PRODUCT CONFORMS TO ALL APPLICABLE

    STANDARDS OF 21 CFR 1040.10 AT DATE OF MANUFACTURE.MANUFACTURED:

    MONTH YEAR

    18532

    Danger Risk of eye damage by laser radiation.

  • ANSI ONT safety guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xv3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    During operation in the supported temperature range, condensation inside the ONT caused by humidity is not an issue. To avoid condensation caused by rapid changes in temperature and humidity, Alcatel-Lucent recommends:

    The door of the ONT not be opened until temperature inside and outside the enclosure has stabilized.

    If the door of the ONT must be opened after a rapid change in temperature or humidity, use a dry cloth to wipe down the metal interior to prevent the risk of condensation.

    When high humidity is present, installation of a cover or tent over the ONT helps prevent condensation when the door is opened.

  • ANSI ONT safety guidelines

    xvi January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xvii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    ETSI ONT safety guidelines

    This chapter provides information about the mandatory regulations that govern the installation and operation of the 7342 ISAM FTTU optical network terminals (ONTs).

    Safety instructions

    This section describes the safety instructions that are provided in the 7342 ISAM FTTU ONT customer documentation and on the equipment.

    Safety instruction boxes

    The safety instruction boxes are provided in the 7342 ISAM FTTU ONT customer documentation. Observe the instructions to meet safety requirements.

    The following is an example of the Danger box.

    The Danger box indicates that the described activity or situation may pose a threat to personal safety. It calls attention to a situation or procedure which, if not correctly performed or adhered to, may result in death or serious physical harm.

    Do not proceed beyond a Danger box until the indicated conditions are fully understood and met.

    The following is an example of the Warning box.

    Danger Possibility of personal injury.

  • ETSI ONT safety guidelines

    xviii January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    The Warning box indicates that the described activity or situation may, or will, cause equipment damage, loss of data, or serious performance problems. It identifies a possible equipment-damaging situation or provides essential information to avoid the degradation of system operations or data.

    Do not proceed beyond a warning until the indicated conditions are fully understood and met.

    The following is an example of the Caution box.

    The Caution box indicates that the described activity or situation may, or will, cause service interruption.

    Do not proceed beyond a caution until the indicated conditions are fully understood and met.

    The following is an example of the Note box.

    The Note box provides information that assists the personnel working with 7342 ISAM FTTU ONTs. It does not provide safety-related instructions.

    Safety-related labels

    The ONT equipment is labeled with the specific safety instructions and compliance information that is related to a variant of the ONT. Observe the instructions on the safety labels.

    Table 2 provides sample safety labels on the ONT equipment.

    Table 2 Safety labels

    Figure 6 shows the CE declaration of conformity for the ONT equipment.

    Warning 1 Possibility of equipment damage.

    Warning 2 Possibility of data loss.

    Caution 1 Possibility of service interruption.

    Caution 2 Service interruption.

    Note Information of special interest.

    Description Label text

    ESD warning Caution: This assembly contains an electrostatic sensitive device.

    Laser classification Class 1 laser product

    CE marking CE declaration of conformity

  • ETSI ONT safety guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xix3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Figure 6 CE declaration of conformity on the ONT equipment

    No1013

  • ETSI ONT safety guidelines

    xx January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    Safety standards compliance

    This section describes the ONT compliance with the European safety standards.

    EMC, EMI, and ESD compliance

    The ONT equipment complies with the following EMC, EMI, and ESD requirements:

    EN 300 386 V1.3.2 (2003-05): Electromagnetic Compatibility and Radio Spectrum Matters (ERM): Telecommunications Network Equipment; Electromagnetic Compatibility (EMC) requirements; Electrostatic Discharge (ESD) requirements

    EN 55022 (1998): Class B, Information Technology Equipment, Radio Disturbance Characteristics, limits and methods of measurement

    EN 55024 (1998): Information Technology Equipment, Immunity Characteristics, limits and methods of measurement

    Equipment safety standard compliance

    The ONT equipment complies with the requirements of EN 60950-1, Safety of Information Technology Equipment.

    Environmental standard compliance

    The ONT equipment complies with the EN 300 019 European environmental standards.

    Laser product standard compliance

    The ONT equipment complies with EN 60825-1 for laser products.

    Resistibility requirements compliance

    The ONT equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to overvoltage and overcurrents.

    Acoustic noise emission standard compliance

    The ONT equipment complies with EN 300 753 acoustic noise emission limit and test methods.

    Electrical safety guidelines

    This section provides the electrical safety guidelines for the ONT equipment.

  • ETSI ONT safety guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxi3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Power supplies

    The use of any non-Alcatel-Lucent approved power supplies or power adaptors is not supported or endorsed by Alcatel-Lucent. Such use will void any warranty or support contract with Alcatel-Lucent. Such use greatly increases the danger of damage to equipment or property.

    Cabling

    The following are the guidelines regarding cables used for the ONT equipment:

    All cables must be approved by the relevant national electrical code. The cables for outdoor installation of ONTs must be suitable for outdoor use. The ONTs must be evaluated for use with external wiring that may not exceed

    140 ft (43 m) in reach. However, the power cable must not exceed 100 ft (31 m).

    Protective earth

    Earthing and bonding of the ONTs must comply with the requirements of local electrical codes.

    ESD safety guidelines

    The ONT equipment is sensitive to ESD. Operations personnel must observe the following ESD instructions when they handle the ONT equipment.

    During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD.

    Laser safety guidelines

    Observe the following instructions when you perform installation, operations, and maintenance tasks on the ONT equipment.

    Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system.

    Note The ONTs comply with the U.S. National Electrical Code. However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards.

    Caution This equipment is ESD sensitive. Proper ESD protections should be used when you enter the TELCO Access portion of the ONT.

  • ETSI ONT safety guidelines

    xxii January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    Observe the following danger for laser hazard. Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules.

    Laser classification

    The ONT is classified as a Class 1 laser product based on its transmit optical output.

    Transmit optical output

    The maximum transmit optical output of an ONT is +5 dBm.

    Normal laser operation

    In normal operation, fiber cable laser radiation is always off until it receives signal from the line terminal card.

    Eyes can be damaged when they exposed to a laser beam. Operating personnel must observe the instructions on the laser explanatory label before plugging in the optical module.

    Location class

    Use cable supports and guides to protect the receptacles from strain.

    Environmental requirements

    The outdoor and modular ONTs must not be installed at a location where the maximum ambient temperature exceeds 60C (140F), with no solar loading.The indoor ONT must not be installed in a location where the ambient temperature range exceeds 0C (32F) to 40C (104F) with no solar loading.

    Danger There may be laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to the laser beam.

    Danger Possibility of equipment damage. Risk of eye damage by laser radiation.

    Danger Risk of eye damage by laser radiation.

  • ETSI ONT safety guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxiii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    During operation in the supported temperature range, condensation inside the ONT caused by humidity is not an issue. To avoid condensation caused by rapid changes in temperature and humidity, Alcatel-Lucent recommends:

    The door of the ONT not be opened until temperature inside and outside the enclosure has stabilized.

    If the door of the ONT must be opened after a rapid change in temperature or humidity, use a dry cloth to wipe down the metal interior to prevent the risk of condensation.

    When high humidity is present, installation of a cover or tent over the ONT helps prevent condensation when the door is opened.

  • ETSI ONT safety guidelines

    xxiv January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxv3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    ETSI environmental and CRoHS guidelines

    This chapter provides information about the ETSI environmental China Restriction of Hazardous Substances (CRoHS) regulations that govern the installation and operation of the 7342 ISAM FTTU packet optical line termination (P-OLT) and Optical Network Termination (ONT) systems. This chapter also includes environmental operation parameters of general interest.

    Environmental labels

    This section describes the environmental instructions that are provided in the 7342 ISAM FTTU customer documentation, equipment, and location where the equipment resides.

    Overview

    CRoHS is applicable to Electronic Information Products (EIP) manufactured or sold and imported in the territory of the mainland of the Peoples Republic of China. EIP refers to products and their accessories manufactured by using electronic information technology, including electronic communications products and such subcomponents as batteries and cables.

    Environmental related labels

    Environmental labels are located on appropriate equipment. The following are sample labels.

  • ETSI environmental and CRoHS guidelines

    xxvi January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    Products below Maximum Concentration Value (MCV) label

    Figure 7 shows the label that indicates a product is below the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products). Products with this label are recyclable. The label may be found in this documentation or on the product.

    Figure 7 Products below MCV value label

    Products containing hazardous substances above Maximum Concentration Value (MCV) label

    Figure 8 shows the label that indicates a product is above the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products). The number contained inside the label indicates the Environment-Friendly User Period (EFUP) value. The label may be found in this documentation or on the product.

    18986

  • ETSI environmental and CRoHS guidelines

    Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxvii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Figure 8 Products above MCV value label

    Together with major international telecommunications equipment companies, Alcatel-Lucent has determined it is appropriate to use an EFUP of 50 years for network infrastructure equipment and EFUP of 20 years for handsets and accessories. These values are based on manufacturers' extensive practical experience of the design, manufacturing, maintenance, usage conditions, operating environments and physical condition of infrastructure and handsets after years of service. The values reflect minimum values and refer to products operated according to the intended use conditions. See Hazardous Substances Table (HST) for more information.

    Hazardous Substances Table (HST)

    This section describes the compliance of the P-OLT and ONT equipment to the CRoHS standard when the product and subassemblies contain hazardous substances beyond the MCV value. This information is found in this user documentation where part numbers for the product and subassemblies are listed. It may be referenced from ordering information in other P-OLT and ONT documentation.

    The HST document for P-OLT and ONT equipment is available from the following locations.

    http://www.alcatel-lucent.com/cn http://www.alcatel.com.cn/product_solution/in4.asp http://www.rfsworld.com/userfiles/pdf/china_rohs_hst_rfs_ch_ed3.2.pdf

    Other environmental requirements

    Observe the following requirements when handling the P-OLT or ONT equipment.

    18985

  • ETSI environmental and CRoHS guidelines

    xxviii January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

    ONT environmental requirements

    The outdoor and modular ONTs must not be installed at a location where the maximum ambient temperature exceeds 60C (140F), with no solar loading.The indoor ONT must not be installed in a location where the ambient temperature range exceeds 0C (32F) to 40C (104F) with no solar loading.

    Storage

    According to ETS 300-019-1-1, storage of P-OLT equipment must be in Class 1.1, weather-protected, not temperature-controlled storage locations.

    Transportation

    According to EN 300 019-1-2 - Class 2.3, transportation of the P-OLT equipment must be packed, public transportation with no rain on packing allowed.

    Stationary use

    According to EN 300 019-1-3 - Class 3.1/3.E, stationary use of P-OLT equipment must be in a temperature-controlled location with no condensation allowed.

    Thermal limitations

    When the P-OLT is installed in the CO or CEV, install air filters on the P-OLT. The thermal limitations for P-OLT operation in a CO or CEV are:

    operating temperature: 5C (41F) to 40C (104F) short-term temperature: 5C (23F) to 50C (122F) operating relative humidity: 5% to 85% short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg

    End-of-life collection and treatment

    At the end of life, the P-OLT products are subject to the applicable local legislations that implement the European Directive 2002/96EC on waste electrical and electronic equipment (WEEE).There can be different requirements for collection and treatment in different member states of the European Union.

  • Contents

    Preface iiiScope ............................................................................................... iiiAudience ............................................................................................... iiiRequired knowledge................................................................................... iiiAssistance and ordering phone numbers ........................................................... iiiAlcatel-Lucent quality processes .................................................................... ivSafety information..................................................................................... ivSpecial information.................................................................................... iv

    Procedures with options or substeps ................................................ ivProcedure 1 Example of options in a procedure...................................vProcedure 2 Example of required substeps in a procedure ......................v

    ANSI ONT safety guidelines viiSafety instructions.................................................................................... vii

    Safety instruction boxes ............................................................. viiAlcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxix3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

    Safety-related labels .................................................................viiiSafety standards compliance......................................................................... ix

    EMC, EMI, and ESD standards compliance ...........................................xEquipment safety standard compliance .............................................xEnvironmental standards compliance ................................................xLaser product standards compliance.................................................xResistibility requirements compliance...............................................x

    Electrical safety guidelines............................................................................xPower supplies.......................................................................... xiCabling................................................................................... xiProtective earth ........................................................................ xi

    ESD safety guidelines.................................................................................. xi

  • ContentsLaser safety guidelines................................................................................ xiLaser warning labels .................................................................. xiiLaser classification................................................................... xiiiTransmit optical output ..............................................................xivNormal laser operation...............................................................xivLocation class..........................................................................xiv

    Environmental requirements........................................................................xiv

    ETSI ONT safety guidelines xviiSafety instructions................................................................................... xvii

    Safety instruction boxes ............................................................ xviiSafety-related labels ............................................................... xviii

    Safety standards compliance........................................................................ xxEMC, EMI, and ESD compliance...................................................... xxEquipment safety standard compliance ........................................... xxEnvironmental standard compliance ............................................... xxLaser product standard compliance ................................................ xxResistibility requirements compliance............................................. xxAcoustic noise emission standard compliance .................................... xx

    Electrical safety guidelines.......................................................................... xxPower supplies.........................................................................xxiCabling..................................................................................xxiProtective earth .......................................................................xxi

    ESD safety guidelines.................................................................................xxiLaser safety guidelines...............................................................................xxi

    Laser classification................................................................... xxiiTransmit optical output ............................................................. xxiiNormal laser operation.............................................................. xxiiLocation class......................................................................... xxii

    Environmental requirements....................................................................... xxii

    ETSI environmental and CRoHS guidelines xxvEnvironmental labels ................................................................................ xxv

    Overview .............................................................................. xxvEnvironmental related labels....................................................... xxv

    Hazardous Substances Table (HST)...............................................................xxviiOther environmental requirements ..............................................................xxvii

    ONT environmental requirements ...............................................xxviiiStorage...............................................................................xxviiiTransportation......................................................................xxviiiStationary use ......................................................................xxviiiThermal limitations ................................................................xxviiiEnd-of-life collection and treatment ...........................................xxviiixxx January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • ContentsGeneral system description

    1 ONT overview 1-11.1 About this document ................................................................... 1-21.2 ONT general description ............................................................... 1-2

    P-OLTs and V-OLTs................................................................... 1-3ONTs.................................................................................... 1-3EMS ..................................................................................... 1-9

    1.3 ONT product identification ............................................................ 1-9

    2 Feature descriptions 2-12.1 Overview ................................................................................. 2-22.2 ONT Release 04.05.00 features ....................................................... 2-22.3 ONT Release 04.04.10 features ....................................................... 2-32.4 ONT Release 04.04.00 features ....................................................... 2-42.5 ONT Release 04.03.07 features ....................................................... 2-62.6 ONT Release 4.3.5 features ........................................................... 2-72.7 ONT Release 3.0 features.............................................................. 2-82.8 ONT Release 2.0 features.............................................................. 2-92.9 ONT Release 1.0 features............................................................. 2-102.10 ONT initial release features .......................................................... 2-10

    3 Application notes 3-13.1 Overview ................................................................................. 3-23.2 ONT Release 04.04.xx application notes ............................................ 3-23.3 ONT Release 4.3.5 application notes ................................................ 3-23.4 ONT Release 2.0 application notes ................................................... 3-3

    4 ONT software and security features 4-14.1 Overview ................................................................................. 4-2

    Software architecture levels ....................................................... 4-24.2 GPON transmission support ............................................................ 4-3

    FEC ..................................................................................... 4-3Fragmentation ........................................................................ 4-3AES ..................................................................................... 4-4

    4.3 ONT activation methods ............................................................... 4-4SLID entry via craft terminal ....................................................... 4-4SLID entry via Ethernet port........................................................ 4-4SLID entry via first POTS port ...................................................... 4-4

    4.4 NTP server authentication ............................................................. 4-54.5 Physical ONT security .................................................................. 4-54.6 Rogue ONT defence..................................................................... 4-5

    Laser stuck on ........................................................................ 4-6Duplicate serial numbers............................................................ 4-6Receive and transmit errors ........................................................ 4-6Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxxi3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

  • Contents4.7 802.1x authentication .................................................................. 4-7Port-based authentication .......................................................... 4-7802.1x support assumptions ........................................................ 4-8User session disconnection by system............................................. 4-8Re-authentication .................................................................... 4-8

    4.8 Anti-spoofing mechanism .............................................................. 4-9

    5 SoC based ONT functional blocks 5-15.1 Overview ................................................................................. 5-25.2 System on a Chip (SoC) technology................................................... 5-25.3 SoC functional blocks................................................................... 5-3

    SoC functionality and service connections ....................................... 5-3Voice subsystem...................................................................... 5-4Data and IP video subsystems over Ethernet interface ........................ 5-4Time calibration...................................................................... 5-5

    5.4 SoC ONTs with RF video subsystem................................................... 5-55.5 SoC ONTs with MoCA subsystem ...................................................... 5-65.6 SoC ONTs with eight POTS ports ...................................................... 5-85.7 SoC ONTs with CES DS1/E1 interfaces ............................................... 5-8

    Clocking, network synchronization, and time calibration for CES............ 5-9

    6 LP MDU and modular ONT hardware functional blocks 6-16.1 Overview ................................................................................. 6-26.2 LP MDU ONT functional blocks ........................................................ 6-2

    Optical functional block............................................................. 6-4GPON MAC FPGA...................................................................... 6-4Gigabit Ethernet multilayer switch................................................ 6-5On-board controller.................................................................. 6-5Test and diagnostic functions ...................................................... 6-6Complex programmable logic device ............................................. 6-7Network synchronization............................................................ 6-7Time calibration...................................................................... 6-7Alexandria FPGA...................................................................... 6-7VDSL2 subsystem ..................................................................... 6-7Voice subsystem...................................................................... 6-8Ethernet subsystem .................................................................. 6-8RF video amplifier ................................................................... 6-9

    6.3 Modular ONT and plug-in unit functional blocks ................................... 6-9Local switching ...................................................................... 6-10Control and management .......................................................... 6-11Plug-in service units ................................................................ 6-12Network synchronization........................................................... 6-13Connections .......................................................................... 6-14Time calibration..................................................................... 6-14

    7 ONT equipment layout 7-17.1 Overview ................................................................................. 7-27.2 Equipment options ...................................................................... 7-27.3 Connections .............................................................................. 7-2xxxii January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • Contents7.4 Indoor ONT connections and physical components ................................ 7-4I-020E-B, I-020E-H, and I-020G-F connections and components .............. 7-4I-221E-A and I-220E-A connections and components ........................... 7-5I-211M-E connections and components ........................................... 7-7I-211M-D connections and components ........................................... 7-8

    7.5 Outdoor ONT connections and components........................................ 7-107.6 LP MDU outdoor ONT connections and components .............................. 7-13

    O-24121V-A and O-24120V-A connections and components .................. 7-13O-24121G-A and O-24120G-A connections and components.................. 7-14

    7.7 Modular ONT and plug-in unit connections and components.................... 7-157.8 Business and SOHO ONT connections and components........................... 7-20

    B-8112-A and B-8102-A connections.............................................. 7-22O-821G-D and O-820G-D connections ............................................ 7-24

    7.9 Cable storage compartments......................................................... 7-263EM 17661 AB compartment....................................................... 7-263EM 17661 AC compartment....................................................... 7-273EM 20293 AA compartment....................................................... 7-28

    7.10 Location options........................................................................ 7-30

    8 UPS LEDs 8-18.1 Overview ................................................................................. 8-28.2 UPS LEDs.................................................................................. 8-2

    9 ONT LEDs 9-19.1 Overview ................................................................................. 9-29.2 Outdoor ONT LEDs ...................................................................... 9-39.3 Indoor ONT LEDs......................................................................... 9-99.4 Modular ONT and service unit LEDs ................................................. 9-139.5 Business ONT LEDs ..................................................................... 9-16

    10 ONT technical specifications 10-110.1 Overview ................................................................................ 10-210.2 Physical specifications ................................................................ 10-2

    LP MDU ONT.......................................................................... 10-2Outdoor ONT ......................................................................... 10-3Indoor ONT (I-221E-A and I-220E-A) .............................................. 10-3Indoor ONT (I-020E-B, I-020G-F, and I-020E-H)................................. 10-4Indoor ONT (I-211M-E) .............................................................. 10-4Indoor ONT (I-211M-D).............................................................. 10-4Modular ONTs ........................................................................ 10-5Business and SOHO ONTs........................................................... 10-5

    10.3 Environmental requirements ......................................................... 10-6Temperature and humidity range ................................................ 10-6Environmental considerations for rack installed ONTs ........................ 10-8

    10.4 Ethernet interface specifications.................................................... 10-810.5 POTS interface specifications ........................................................ 10-810.6 VDSL1 and VDSL2 interface specifications ......................................... 10-910.7 DS1/E1 interface specifications.................................................... 10-10Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxxiii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

  • Contents10.8 RF video interface specifications .................................................. 10-10Coaxial connectivity in the home and design guidelines.................... 10-11Configuration recommendations................................................ 10-1214 dBmV RF video receivers ..................................................... 10-1318 dBmV RF video receivers ..................................................... 10-1432 dBmV RF video receivers ..................................................... 10-14

    10.9 ONT optical budget .................................................................. 10-1510.10 Power consumption .................................................................. 10-16

    Outdoor ONTs ...................................................................... 10-16Indoor ONT (I-020E-H) ............................................................ 10-17Indoor ONT (I-020G-F) ............................................................ 10-18Indoor ONT (I-240G-A and I-241G-A) ........................................... 10-18Indoor ONT (I-220E-A and I-221E-A) ............................................ 10-18Indoor ONT (in-wall MoCA)....................................................... 10-19Indoor ONT (I-211M-D)............................................................ 10-19Indoor ONT (I-211M-G) ........................................................... 10-20SOHO outdoor ONT................................................................ 10-20Business ONT....................................................................... 10-22LP MDU ONT........................................................................ 10-22Modular ONT and plug in unit ................................................... 10-23

    11 ONT statistics and performance monitoring 11-111.1 Overview ................................................................................ 11-211.2 ONT performance monitoring ........................................................ 11-211.3 ONT performance monitoring functions ............................................ 11-211.4 ONT performance monitoring data .................................................. 11-3

    Counters .............................................................................. 11-3Supported ONT counters ........................................................... 11-4

    11.5 ONT performance reporting .......................................................... 11-9ONT statistical viewing............................................................. 11-9TCA counters and alarms......................................................... 11-10Status reporting ................................................................... 11-11Diagnostic data capturing........................................................ 11-12

    ONT unit data sheets

    12 Index of ONT unit data sheets 12-112.1 Overview ................................................................................ 12-212.2 Unit data sheet overview ............................................................. 12-2

    13 B-8102G-A and B-8112G-A unit data sheet 13-113.1 Identification ........................................................................... 13-213.2 General description.................................................................... 13-213.3 Hardware and software features .................................................... 13-213.4 Special considerations................................................................. 13-4xxxiv January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • Contents14 I-020E-B and I-020E-H unit data sheet 14-114.1 Identification ........................................................................... 14-214.2 General description.................................................................... 14-214.3 ONT hardware and software features............................................... 14-214.4 Special considerations................................................................. 14-4

    15 I-020G-F unit data sheet 15-115.1 Identification ........................................................................... 15-215.2 General description.................................................................... 15-215.3 ONT hardware and software features............................................... 15-215.4 Special considerations................................................................. 15-4

    16 I-211M-D unit data sheet 16-116.1 Identification ........................................................................... 16-216.2 General description.................................................................... 16-216.3 ONT hardware and software features............................................... 16-316.4 Special considerations................................................................. 16-4

    17 I-211M-E unit data sheet 17-117.1 Identification ........................................................................... 17-217.2 General description.................................................................... 17-217.3 ONT hardware and software features............................................... 17-217.4 Special considerations................................................................. 17-4

    18 I-221E-A and I-220E-A unit data sheet 18-118.1 Identification ........................................................................... 18-218.2 General description.................................................................... 18-218.3 ONT hardware and software features............................................... 18-218.4 Special considerations................................................................. 18-4

    19 M-300-A and S-840V-A unit data sheet 19-119.1 Identification ........................................................................... 19-219.2 General description.................................................................... 19-219.3 ONT hardware and software features............................................... 19-219.4 Special considerations................................................................. 19-4

    20 O-210E-B and O-211E-B unit data sheet 20-120.1 Identification ........................................................................... 20-220.2 General description.................................................................... 20-220.3 ONT hardware and software feature................................................ 20-320.4 Special considerations................................................................. 20-4

    21 O-211M-C and O-211M-E unit data sheet 21-121.1 Identification ........................................................................... 21-221.2 General description.................................................................... 21-2Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxxv3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

  • Contents21.3 ONT hardware and software features............................................... 21-221.4 Special considerations................................................................. 21-4

    22 O-420E-B and O-421E-B unit data sheet 22-122.1 Identification ........................................................................... 22-222.2 General description.................................................................... 22-222.3 ONT hardware and software features............................................... 22-322.4 Special considerations................................................................. 22-4

    23 O-820G-D and O-821G-D unit data sheet 23-123.1 Identification ........................................................................... 23-223.2 General description.................................................................... 23-223.3 ONT hardware and software features............................................... 23-223.4 Special considerations................................................................. 23-4

    24 O-821M-E unit data sheet 24-124.1 Identification ........................................................................... 24-224.2 General description.................................................................... 24-224.3 ONT hardware and software features............................................... 24-224.4 Special considerations................................................................. 24-4

    25 O-24121G-A and O-24120G-A unit data sheet 25-125.1 Identification ........................................................................... 25-225.2 General description.................................................................... 25-225.3 Features and application notes ...................................................... 25-225.4 Special considerations................................................................. 25-4

    26 O-24121V-A and O-24120V-A unit data sheet 26-126.1 Identification ........................................................................... 26-226.2 General description.................................................................... 26-226.3 Features and application notes ...................................................... 26-226.4 Special considerations................................................................. 26-4

    UPS unit data sheets

    27 Index of unit data sheets for UPSs 27-127.1 Overview ................................................................................ 27-227.2 Unit data sheet overview ............................................................. 27-227.3 UPS functional comparison ........................................................... 27-2xxxvi January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • Contents28 APC 24 W 12 V dc UPS unit data sheet 28-128.1 Identification ........................................................................... 28-228.2 Features and application notes ...................................................... 28-228.3 General description.................................................................... 28-228.4 Operating modes and LEDs ........................................................... 28-3

    Current UPS model (ANSI).......................................................... 28-3UPS model prior to FGH 1.0.5 (ANSI)............................................. 28-4

    28.5 Alarms.................................................................................... 28-528.6 Connectors .............................................................................. 28-528.7 Environmental requirements ......................................................... 28-628.8 Physical measurements ............................................................... 28-6

    29 PowerShield CP50B48 UPS unit data sheet 29-129.1 Identification ........................................................................... 29-229.2 Features and application notes ...................................................... 29-229.3 General description.................................................................... 29-329.4 Operating modes ....................................................................... 29-329.5 Status LEDs .............................................................................. 29-329.6 Alarms.................................................................................... 29-429.7 Connections ............................................................................. 29-429.8 Specifications ........................................................................... 29-5

    Physical description................................................................. 29-6Power ................................................................................. 29-6Environmental ....................................................................... 29-6

    30 APC 150 W 48 V dc UPS unit data sheet 30-130.1 Identification ........................................................................... 30-230.2 Features and application notes ...................................................... 30-230.3 General description.................................................................... 30-230.4 Operating modes ....................................................................... 30-330.5 Status LEDs .............................................................................. 30-330.6 Alarms.................................................................................... 30-430.7 Connections ............................................................................. 30-430.8 Specifications ........................................................................... 30-5

    Physical description................................................................. 30-5Power ................................................................................. 30-5Environmental ....................................................................... 30-6

    31 APC UPS cable assembly with beeper unit data sheet 31-131.1 Identification ........................................................................... 31-231.2 Features and application notes ...................................................... 31-231.3 General description.................................................................... 31-231.4 Output connections on the PowerShield............................................ 31-331.5 Alarm descriptions ..................................................................... 31-331.6 Interface details........................................................................ 31-4Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxxvii3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

  • Contents32 CyberPower CyberShield CS 24 UPS unit data sheet 32-132.1 Identification ........................................................................... 32-232.2 Features and application notes ...................................................... 32-232.3 General description.................................................................... 32-232.4 Status LEDs .............................................................................. 32-232.5 Alarms.................................................................................... 32-332.6 Connections ............................................................................. 32-432.7 Specifications ........................................................................... 32-4

    Physical description................................................................. 32-4Power ................................................................................. 32-5Environmental ....................................................................... 32-5

    33 CyberPower CyberShield CS 50 UPS unit data sheet 33-133.1 Identification ........................................................................... 33-233.2 Features and application notes ...................................................... 33-233.3 General description.................................................................... 33-233.4 Status LEDs .............................................................................. 33-233.5 Alarms.................................................................................... 33-333.6 Connections ............................................................................. 33-433.7 Specifications ........................................................................... 33-4

    Physical description................................................................. 33-4Power ................................................................................. 33-5Environmental ....................................................................... 33-5

    34 Delta OPSU/BBU unit data sheet 34-134.1 Identification ........................................................................... 34-234.2 Features and application notes ...................................................... 34-234.3 General description.................................................................... 34-334.4 Operating modes ....................................................................... 34-334.5 Status LEDs and user controls ........................................................ 34-334.6 Alarms.................................................................................... 34-534.7 Connections ............................................................................. 34-634.8 Specifications ........................................................................... 34-7

    Physical description................................................................. 34-7Power ................................................................................. 34-8Environmental ....................................................................... 34-9

    35 FlexNet FMPS-150W 48 V dc UPS unit data sheet 35-135.1 Identification ........................................................................... 35-235.2 Features and application notes ...................................................... 35-235.3 General description.................................................................... 35-235.4 Operating modes ....................................................................... 35-335.5 Status LEDs .............................................................................. 35-335.6 Alarms.................................................................................... 35-435.7 Connections ............................................................................. 35-535.8 Specifications ........................................................................... 35-6

    Physical description................................................................. 35-6Power ................................................................................. 35-6Environmental ....................................................................... 35-6xxxviii January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • Contents36 Flexpoint UPS unit data sheet 36-136.1 Identification ........................................................................... 36-236.2 Features and application notes ...................................................... 36-236.3 General description.................................................................... 36-336.4 Exterior power tap/power conversion assembly .................................. 36-336.5 Interior power tap/power converter................................................ 36-436.6 Operating modes and status LEDs ................................................... 36-536.7 Battery................................................................................... 36-536.8 Connectors .............................................................................. 36-636.9 Alarms.................................................................................... 36-636.10 Protective housing/battery chargers................................................ 36-636.11 Physical measurements ............................................................... 36-7

    37 PowerShield CP50B48 UPS unit data sheet 37-137.1 Identification ........................................................................... 37-237.2 Features and application notes ...................................................... 37-237.3 General description.................................................................... 37-337.4 Operating modes ....................................................................... 37-337.5 Status LEDs .............................................................................. 37-337.6 Alarms.................................................................................... 37-437.7 Connections ............................................................................. 37-437.8 Specifications ........................................................................... 37-5

    Physical description................................................................. 37-6Power ................................................................................. 37-6Environmental ....................................................................... 37-6

    Glossary

    IndexAlcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xxxix3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

  • ContentsList of figuresFigure 1 Safety label on the ONT equipment ..................................................... ixFigure 2 Laser product label ....................................................................... xiiFigure 3 Laser classification label ................................................................. xiiFigure 4 Laser warning labels ..................................................................... xiiiFigure 5 Laser product safety label on the ONT equipment...................................xivFigure 6 CE declaration of conformity on the ONT equipment ...............................xixFigure 7 Products below MCV value label ...................................................... xxviFigure 8 Products above MCV value label ......................................................xxviiFigure 1-1 7342 ISAM FTTU network.............................................................. 1-3Figure 4-1 Software architecture levels ......................................................... 4-2Figure 4-2 Rogue ONT failure conditions ........................................................ 4-5Figure 4-3 Authorization of upstream packets at the ONT ................................... 4-9Figure 5-1 SoC hardware block.................................................................... 5-2Figure 5-2 ONT with a diplexer ................................................................... 5-4Figure 5-3 ONT with a triplexer................................................................... 5-6Figure 5-4 ONT with one Ethernet port and MoCA adapter................................... 5-7Figure 5-5 SOHO ONT with two Ethernet ports and one MoCA adapter..................... 5-7Figure 5-6 SoC with external DSP for SOHO and BONT ONTs ................................. 5-8Figure 5-7 Business ONT functional block diagram ............................................ 5-9Figure 6-1 VDSL LP MDU ONT functional blocks ................................................ 6-3Figure 6-2 GE LP MDU ONT functional blocks................................................... 6-4Figure 6-3 Modular ONT functional blocks ..................................................... 6-10Figure 6-4 Service unit functional blocks....................................................... 6-12Figure 7-1 I-020E-B and I-020E-H connections .................................................. 7-4Figure 7-2 I-221E-A indoor ONT connections.................................................... 7-5Figure 7-3 Fiber storage tray...................................................................... 7-6Figure 7-4 I-211M-E with inner cover closed.................................................... 7-7Figure 7-5 I-211M-E indoor ONT connections ................................................... 7-8Figure 7-6 Connectors on an I-211M-D ........................................................... 7-9Figure 7-7 O-421E with inner cover closed..................................................... 7-10Figure 7-8 Connectors on an O-421E ............................................................ 7-11Figure 7-9 Connectors on a O-211E.............................................................. 7-12Figure 7-10 Connectors on an O-24121V-A ..................................................... 7-13Figure 7-11 Connectors on an O-24121G-A..................................................... 7-14Figure 7-12 M-300-A interfaces, connections, and LEDs ..................................... 7-16Figure 7-13 Modular ONT enclosure (external view).......................................... 7-18Figure 7-14 Modular ONT enclosure (internal view) .......................................... 7-19Figure 7-15 S-840V-A .............................................................................. 7-20Figure 7-16 Closed SOHO or business ONT ..................................................... 7-21Figure 7-17 Soho or business ONT showing inner covers ..................................... 7-22Figure 7-18 Connectors on a B-8211G-A ........................................................ 7-23Figure 7-19 Connectors on an O-821G-D SOHO outdoor ONT................................ 7-24Figure 7-20 Connectors on an O-820G-D SOHO outdoor ONT................................ 7-25Figure 7-21 Cable storage compartment (3EM 17661 AB).................................... 7-27Figure 7-22 Cable storage compartment (3EM 17661 AC).................................... 7-28Figure 7-23 Cable storage compartment (3EM 20293 AA).................................... 7-29Figure 7-24 Cable storage compartment with storage box mounting bracket............ 7-30Figure 8-1 APC UPS LED icons for Versions A, B, and C outdoor ONTs and business

    ONT................................................................................. 8-3xl January 2008 Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00ONT Product Information Manual Edition 01 3FE 51455 AAAA TCZZA

  • ContentsFigure 8-2 FlexNet UPS icons for Version D SOHO outdoor ONTs only ...................... 8-4Figure 9-1 Outdoor ONT LEDs (O-421E-B, O-420E-B, O-210E-B, and O-211E-B) ........... 9-4Figure 9-2 SOHO outdoor ONT LEDs .............................................................. 9-5Figure 9-3 LP MDU outdoor ONT LEDs............................................................ 9-6Figure 9-4 Indoor ONT LEDs (I-221E-A and I-220E-A) .......................................... 9-9Figure 9-5 Indoor ONT LEDs (I-020E-B and I-020E-H) ......................................... 9-10Figure 9-6 Modular ONT LEDs..................................................................... 9-14Figure 9-7 Service plug-in unit LEDs ............................................................ 9-14Figure 9-8 Business ONT LEDs .................................................................... 9-16Figure 10-1 RF video overlay design and deployment example........................... 10-11Figure 10-2 Class 1 laser product warning label............................................. 10-15Figure 28-1 UPS icons and description .......................................................... 28-4Figure 29-1 UPS icons and meanings ............................................................ 29-3Figure 29-2 APC UPS connector .................................................................. 29-5Figure 30-1 UPS icons and meanings ............................................................ 30-3Figure 30-2 APC UPS connector .................................................................. 30-5Figure 31-1 APC cable assembly with beeper.................................................. 31-2Figure 31-2 Alarm disable push button for cable beeper .................................... 31-3Figure 31-3 Schematic for typical PowerShield alarm signal ................................ 31-4Figure 34-1 OPSU/BBU LEDs and icons.......................................................... 34-4Figure 34-2 BBU power and alarm connections................................................ 34-5Figure 34-3 BBU output power and alarm connector ......................................... 34-7Figure 35-1 UPS icons and meanings ............................................................ 35-4Figure 35-2 Alarm connector and power terminals ........................................... 35-5Figure 36-1 Power-ring meter base extender.................................................. 36-3Figure 37-1 UPS icons and meanings ............................................................ 37-3Figure 37-2 APC UPS connector .................................................................. 37-5

    List of tablesTable 1 Safety labels ................................................................................viiiTable 2 Safety labels .............................................................................. xviiiTable 1-1 ONT product identification ........................................................... 1-10Table 1-2 Designation for indoor ONT, outdoor ONT, and service plug-in unit ........... 1-10Table 1-3 Designation for the modular ONTs ................................................... 1-11Table 1-4 Designation for business ONTs........................................................ 1-11Table 2-1 Features for ONT 04.05.00 ............................................................. 2-2Table 2-2 Features for ONT 04.04.10 ............................................................. 2-4Table 2-3 Features for ONT 04.04.00 ............................................................. 2-5Table 2-4 Features for ONT 04.03.07 ............................................................. 2-6Table 2-5 Features for ONT 4.3.5 ................................................................. 2-7Table 2-6 Features for ONT 3.0.................................................................... 2-8Table 2-7 Features for ONT 2.0.................................................................... 2-9Table 2-8 Features for ONT 1.0................................................................... 2-10Table 2-9 Features for initial ONT release...................................................... 2-10Table 3-1 Application notes for ONT 04.04.xx .................................................. 3-2Table 3-2 Application notes for ONT 4.3.5....................................................... 3-3Table 3-3 Application notes for ONT 2.0 ......................................................... 3-3Table 5-1 SoC based ONT interfaces .............................................................. 5-2Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.00 January 2008 xli3FE 51455 AAAA TCZZA Edition 01 ONT Product Information Manual

  • ContentsTable 6-1 ONT categories........................................................................... 6-2Table 6-2 Optical functions of the LP MDU ONT motherboard................................ 6-4Table 6-3 GPON MAC FPGA features .............................................................. 6-5Table 6-4 Gigabit Ethernet multilayer switch features ........................................ 6-5Table 6-5 OBC interfaces ........................................................................... 6-6Table 6-6 OBC functions ............................................................................ 6-6Table 6-7 Test and diagnostic functions ......................................................... 6-6Table 6-8 VDSL2 subsystem functions ............................................................ 6-8Table 6-9 Optical functions ....................................................................... 6-10Table 6-10 Modular ONT MAC FPGA and standards ............................................ 6-10Table 6-11 GE multilayer switch features....................................................... 6-11Table 6-12 OBC functions.......................................................................... 6-12Table 6-13 OBC interfaces......................................................................... 6-14Table 7-1 ONT connection capacity............................................................... 7-2Table 7-2 Maximum ONT connections per PON.................................................. 7-4Table 7-3 Indoor ONT connections ................................................................ 7-5Table 7-4 Indoor ONT connections ................................................................ 7-6Table 7-5 In-wall MoCA indoor ONT connectors................................................. 7-8Table 7-6 I-211M-D ONT connectors .............................................................. 7-9Table 7-7 Outdoor ONT connections ............................................................. 7-12Table 7-8 VDSL LP MDU ONT interfaces ......................................................... 7-14Table 7-9 GE LP MDU ONT interfaces ............................................................ 7-15Table 7-10 Modular ONT connections............................................................ 7-17Table 7-11 Business ONT connections ........................................................... 7-23Table 7-12 SOHO ONT connections............................................................... 7-25Table 8-1 Figure list ................................................................................. 8-2Table 8-2 Table list .................................................................................. 8-2Table 8-3 APC UPS LEDs for indoor, Version D SOHO outdoor, business, and

    modular ONTs..................................................................... 8-3Table 8-4 APC UPS LEDs for Versions A, B, and C outdoor ONTs and business ONT ....... 8-3Table 8-5 FlexPoint UPS LEDs for ANSI outdoor ONT deployments only..................... 8-3Table 8-6 FlexNet UPS LEDs for Version D SOHO outdoor ONTs only ........................ 8-4Table 8-7 CyberShield CS 24 UPS LEDs for indoor and outdoor ONTs ........................ 8-4Table 9-1 Figure list ................................................................................. 9-2Table 9-2 Table list .................................................................................. 9-2Table 9-3 Outdoor ONT LEDs (O-210E-B, O-211E-B, O-420E-B, O-421E-B, and

    O-211M-E) ......................................................................... 9-6Table 9-4 Outdoor ONT RJ-45 LEDs (O-210E-B, O-211E-B, O-420E-B, and

    O-421E-B).......................................................................... 9-7Table 9-5 Outdoor ONT RJ-45 LEDs (O-211M-E, O-820G-D and O-821G-D) .................. 9-7Table 9-6 LP MDU outdoor ONT LEDs ............................................................. 9-8Table 9-7 LP MDU outdoor ON


Recommended