+ All Categories
Home > Documents > Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management...

Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management...

Date post: 21-Jul-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
39
Opening up new perspectives for energy. PLATINUM® inverters, monitoring & energy management.
Transcript
Page 1: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

Opening up new perspectives for energy.PLATINUM® inverters, monitoring & energy management.

Page 2: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

Next Energy Solution.Welcome to PLATINUM®.

Page 3: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

54

Dear PLATINUM® customers and partners,

A lot is happening in the photovoltaics market. On the one hand, more solar electricity is being generated than ever before. On the other hand, the focus and main players in the global competition are shifting. And one of these is PLATINUM®. Launched as a premium brand in 2006, PLATINUM® has been trading since April 2013 as an autonomous company belonging to the mutares AG, Munich. So what does this mean for you, our partners and customers?

Only good things! As the premium brand and company PLATINUM®, we will be able to do even more for you in the future. For example with excellent new R3 inverters that deliver one of the highest degree of

In addition, we now also offer even

more training sessions and workshops from our new PLATINUM® PartnerCenter at our site in Wangen.

Above all, PLATINUM® stands out with new priorities in energy management – an area we focus on particu-larly in this catalogue.

But one thing remains unchanged: the exceptional quality of our solutions. Why is this? The answer is simple: the same PLATINUM® employees are working behind the scenes at the same site to deliver these solutions. And this is not going to change.

We have great plans. Please join us on our journey.

Klaus FrehnerManaging Director PLATINUM GmbH

Wangen im Allgäu, June 2013

Page 4: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

76

An independent player in the market.The company PLATINUM®

Originally set up by Diehl Controls, PLATINUM® is trad-ing since 1st April 2013 as an autonomous company belonging to the mutares AG, Munich. So the premium brand from the Allgäu, Germany can distinguish and rise even more. But the same competent, effective and highly capable team is working behind the scenes. The inverters are still manufactured in the Allgäu by Diehl Controls while PLATINUM® develops and sells the inverters.

Therefore the product quality remains at the usual high standard while the strategic new realigned PLATINUM® will set their focus even more on intense consulting, service and training. Our promise: Next energy solution.

4–5 Preface

6 Company

8 Energy management9 How energy management with PLATINUM® works

10–45 Inverters12 PHOTON seal of approval13

14 R3-S2 inverters18 R3-M inverters22 R3-M2 inverters26 R3-6PACK inverters30 TL inverters38 H inverters40 S inverters44

46 References

50–57 Monitoring52 WebMaster Pro54 IOBox55

56 SolarPortal

60–65 Energy management60 WebMaster Home64 Battery

66–74 Information and contact details66 PartnerCenter70 Environmental management72 Addresses

Page 5: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

1 .

2.3.

4.5 .

6 .

98

How energy management works.And what you need for it.

1Source: BMU; BSW; EEG / KWK-G; EEX, Photovoltaics Facts Sheet, Page 2

Standard price de elopments a comparison

How energy management works:

1. Solar modules on the roof absorb solar energy and convert it into direct current (DC).

While energy prices are constantly increasing, the costs associated with self-generated solar electricity remain constant.

Solar modules on the roof, inverters in the cellar – these are the require-ments for greater independence from electricity price developments.

Electricity supply pricebrutto in Cent / kWh

* EstimateSource: BDEW (As at March 2011)

2006 2008 2010 2012 2014* 2016* 2018* 2020* 2032*

19,420,6 21,6 23,2 23,7 24,5

25,5 26,527,4 29,1

30,832,7 34,6

36,738,9

82,9

Constant price for self-generated solar power

Energy is the topic of the future. More and more people are turning to renewable energy sources. For many, solar en-

generated more than 28 terawatt hours of electric power*. More than ever before – and on the rise.

-

All you need is just three components: a system on the roof with a high-performance inverter. A battery that will allow you to use the generated electricity during the evening and morning hours as well, when demand is at its peak. Plus a control system, which monitors and man-

In this way, photovoltaic systems pay for themselves – regardless of the status of the German Renewable Energy Sources Act or the current feed-in rebates. What is more, not only are solar electricity producers able to become independent from rising electricity prices, but they also make an active contribution to protecting the environment.

2. The PLATINUM® inverter then converts the direct energy into alternating current (AC) suitable for the grid. The converted electricity can then be directly used, stored or fed into the public grid.

3. The PLATINUM® Battery stores the electricity ready

for use during the morning or evening.

4. The PLATINUM® Webmaster Home monitors and controls the energy consumption.

5. Devices are supplied with electricity by the

PLATINUM® monitoring system as required with directly generated electricity, stored electricity or electricity supplied by the grid.

6. Via the connection to the grid, surplus solar electricity can be fed into the grid or remaining energy demands can be met.

Page 6: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

1110

eli ering exceptional ef ciency.The PLATINUM® range of inverters.

Tests have shown that PLATINUM® inverters achieve a -

verter, which is now available in two more variants. This makes them the best of their type. In addition, all PLATINUM® inverters offer outstanding quality and absolute reliability. In short, they deliver everything that counts in the world of photovoltaics.

The inverters offer comprehensive data information on the AC and DC side relating to current, voltage and current data. The yield values are recorded around the clock for the day, week, month and year and can be saved for 30 years via the integrated datalogger. Connection couldn‘t be easier thanks to our quick, fast

the entire PLATINUM® range as multi-country devices.

The PLATINUM® product range includes string inverters in the output class from 2 to 22 kW. We also offer in- verters with single and three-phase feed-in, with or with- out a transformer. With devices in the protection classes IP 65 and IP 66 and the PowerBlock system, the PLATINUM® range also covers outdoor applications. Whether for a single-family detached house, a commer-

PLATINUM® offers the right device for every requirement.

Page 7: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

1312

the Photon seal of approval with the rating “A+”. The inverter test from PHOTON supports the PV system op-

PHOTON is tested under exacerbated circumstances. Any- one who makes the grade in this test is really good – just like the PLATINUM® R3.

After testing the PLATINUM® R3 and putting the 16000 R3-M inverter through its paces, the PHOTON test labo-

high irradiation conditions for the inverter from Wangen im Allgäu.

The PHOTON test laboratory has been testing inverters -

tors, such as the input voltage range into account. That makes it comparable with other inverters. The test re-sults are published in the PHOTON magazines on a regu-lar basis.

The apparent power is made up of the effective power and the required reactive power. To date, the effective

reactive power infeed. This resulted in reduced yields.

This is now a thing of the past – the latest R3 models

-out the previous need to over-dimension the inverter.

Tested and rated “A+”. The PLATINUM® R3 receives a seal of approval from PHOTON.

Maximised ratings and 100 % yield. Thanks to the 10 % increase in apparent power.

80 %

90 %

110 %

100 %

70 %

60 %

50 %

40 %

30 %

20 %

10 %

0 %

80 %

90 %

110 %

100 %

70 %

60 %

50 %

40 %

30 %

20 %

10 %

0 %

conventional inverters

Effective power Apparent power

Reactive power

PLATINUM® R3 inverters

Effective power Apparent power

Reactive power

Page 8: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

1514

Excellent in small systems. The PLATINUM® R3-S2 inverter.

Warranty 2 MPP trackers Reactive power

Outdoor IP 66 Efficiency

98,5 %< 25 kW 10 –100 kWShading Three-phase

The transformerless high-performance inverter PLATINUM® R3-S2 is the ideal solution for privately owned photovoltaic systems. The little brother of the

Thanks to its two boost trackers, it has a particularly advantageous MPP voltage range and offers maximum

roofs, dormer windows or garages. Just like all of the other R3 inverters, it offers IP 66 protection for use outdoors. Its passive ventilation reduces noise levels and maintenance requirements. The unit is easy to install, and master programming is performed automatically via the PLATINUM® network EIA 485. The graphics display shows all important operating data in a clearly legible display – even during the night. The range in-cludes four models from 5 to 9 kW.

2 MPP trackers for the utmost

in the lower power output range

RAC-MPP® technology for rapid MPP tracking

Pure convection cooling reduces main- tenance requirements and noise levels

Integrated datalogger provides storage capacity for 30 years worth of operating data

Suitable for universal use thanks to

Maximised ratings in medium-voltage plants

Free 10-year manufacturer‘s warranty

Whether east-west, garage or dormer roof.The R3-S2 inverter is the perfect solution for tricky challenges.

It will be available from Q4/2013.

East-west roof With garage With dormer roof

Boost MPP

Power Generating Plants Connected to the Medium Voltage Grid” and the “Low-voltage Directive AR-N-4105” as of its coming into effect as the successor directive of VDE 0126-1-1.

Even in non-standard irradiation scenarios like shading, inclined roofs and roofs facing different directions, the R3-S2 secures optimised yields due to its

Page 9: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

1716

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com

Speci cationsR3 inverter 5500 R3-S2 7000 R3-S2

DC Input

Max. PV power 5,700 Wp 6,900 Wp

Max. DC power (@ cos phi = 1) 5,200 W 6,250 W

MPPT voltage range 150 ... 720 V

Max. input voltage 900 V

Max. MPPT inout current 2 x 9.5 A

Number of string inputs 2

Number of MPP trackers 2

DC disconnector

DC short circuit current 2 x 14 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 5,000 W 6,000 W

Rated current 3 x 7.2 A 3 x 8.7 A

Max. apparent power 5,600 VA 6,700 VA

Max. AC current 3 x 9.9 A 3 x 11.9 A

Power feed starts at 20 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 37 kg

Dimensions (H x W x D in mm) 626 x 547 x 290

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 5500 R3-S2B 7000 R3-S2B

Speci cationsR3 inverter 8000 R3-S2 9000 R3-S2

DC Input

Max. PV power 8,000 Wp 9,100 Wp

Max. DC power (@ cos phi = 1) 7,300 W 8,.300 W

MPPT voltage range 150 ... 720 V

Max. input voltage 900 V

Max. MPPT inout current 2 x 9.5 A

Number of string inputs 2

Number of MPP trackers 2

DC disconnector

DC short circuit current 2 x 14 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 7,000 W 8,000 W

Rated current 3 x 10.1 A 3 x 11.6 A

Max. apparent power 7,800 VA 8,900 VA

Max. AC current 3 x 13 A 3 x 13.1 A

Power feed starts at 20 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 37 kg

Dimensions (H x W x D in mm) 626 x 547 x 290

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 8000 R3-S2B 9000 R3-S2B

Standard Optional – Not available Standard Optional – Not available

Page 10: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

1918

Pulls out a cool 98 6 %. The PLATINUM® R3-M inverter.

Power Generating Plants Connected to the Medium Voltage Grid” and the “Low-voltage Directive AR-N-4105” as of its coming into effect as the successor directive of VDE 0126-1-1.

Warranty Outdoor IP 66

Efficiency < 25 kW 10 –100 kW > 100 kWShading Three-phase

The transformerless, three-phase high-performance -

uct family. It is smaller, more compact, more light-

ratings of medium-voltage systems to be maximised. The pure convection cooling reduces noise levels and maintenance requirements. Furthermore, ease of installation and comissioning are assured by the low weight and automatic master programming via the PLATINUM® network EIA 485. The graphics display shows all important operating data in a clearly legible display – even during the night. The range contains

Maximised ratings in medium-voltage

apparent power

in the lower power output range

RAC-MPP® technology for rapid MPP tracking

Pure convection cooling reduces maintenance requirements and noise levels

Integrated datalogger provides storage capacity for 30 years worth of operating data

Suitable for universal use thanks to

Free 10-year manufacturer‘s warranty

Stronger than the competition.Thanks to D -X®.

Reactive powerDUAL-X®

98,4 %

98,6 %

98,8 %

98,2 %

98,0 %

97,8 %

97,6 %

97,4 %

97,2 %

97,0 %

350 400 450 500 550 600 650 700

eta [%]

U [DC]

PLATINUM 16000 R3-M Competitor 1 Competitor 2 Competitor 3

Page 11: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

2120

Speci cationsR3 inverter 7000 R3-M 9000 R3-M 11000 R3-M

DC Input

Max. PV power 6,700 Wp 9,000 Wp 11,200 Wp

Max. DC power (@ cos phi = 1) 6,150 W 8,200 W 10,250 W

MPPT voltage range 350 ... 720 V

Max. input voltage 900 V

Max. MPPT inout current 2 x 10 A 2 x 13 A 2 x 16 A

Number of string inputs 1 + 1 2 + 2

Number of MPP trackers 1

DC disconnector

DC short circuit current 14 A 18 A 22 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 6,000 W 8,000 W 10,000 W

Rated current 3 x 8.7 A 3 x 11.6 A 3 x 14.5 A

Max. apparent power 6,700 VA 8,900 VA 11,200 VA

Max. AC current 3 x 11.9 A 3 x 13.1 A 3 x 20 A

Power feed starts at 20 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 36 kg 44 kg

Dimensions (H x W x D in mm) 626 x 547 x 290

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 7000 R3-MDX-10 9000 R3-MDX-10 11000 R3-MDX-10

Speci cationsR3 inverter 14000 R3-M 16000 R3-M

DC Input

Max. PV power 15,200 Wp 16,900 Wp

Max. DC power (@ cos phi = 1) 13,800 W 15,350 W

MPPT voltage range 350 ... 720 V

Max. input voltage 900 V

Max. MPPT inout current 2 x 21 A 2 x 24 A

Number of string inputs 2 + 2

Number of MPP trackers 1

DC disconnector

DC short circuit current 29 A 33 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 13,500 W 15,000 W

Rated current 3 x 19.6 A 3 x 21.7 A

Max. apparent power 15,000 VA 16,700 VA

Max. AC current 3 x 24.2 A

Power feed starts at 20 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 44 kg

Dimensions (H x W x D in mm) 626 x 547 x 290

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 14000 R3-MDX-10 16000 R3-MDX-10

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com

Standard Optional – Not available Standard Optional – Not available

Page 12: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

2322

Brings an extra tracker into the game.The PLATINUM® R3-M2 inverter.

Power Generating Plants Connected to the Medium Voltage Grid” and the “Low-voltage Directive AR-N-4105” as of its coming into effect as the successor directive of VDE 0126-1-1.

Efficiency < 25 kW 10 –100 kW > 100 kWShading Three-phase

With its additional MPP tracker, this transformerless, three-phase high-performance inverter R3-M2 increases

ideal for partially shaded roofs, east-west facing roofs or roof/garage combinations. Thanks to the innovative

-fective power enables the ratings of medium-voltage systems to be maximised. The pure convection cooling reduces maintenance requirements and noise levels.The ease of installation and commissioning are assured by the low weight and automatic master programming via the PLATINUM® network EIA 485. The graphics display shows all important operating data in a clearly legible display – even during the night. Four models from 9 to 16 kW are available.

2 MPP trackers for the utmost

Maximised ratings in medium-voltage plants

in the lower power output range

RAC-MPP® technology for rapid MPP tracking.

Pure convection cooling reduces maintenance requirements and noise levels

Integrated datalogger provides storage capacity for 30 years worth of operating data

Suitable for universal use thanks to

Free 10-year manufacturer‘s warranty

Impresses in direct comparisons also in terms of design exi ility.

98,4 %

98,6 %

98,8 %

98,2 %

98,0 %

97,8 %

97,6 %

97,4 %

97,2 %

97,0 %

350 400 450 500 550 600 650 700

eta [%]

U [DC]

PLATINUM 16000 R3-M Competitor 1 Competitor 2 Competitor 3

Warranty 2 MPP trackers Outdoor IP 66Reactive powerBoost MPPDUAL-X®

Page 13: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

2524

Speci cationsR3 inverter 9000 R3-M2 11000 R3-M2

DC Input

Max. PV power 9,000 Wp 11,200 Wp

Max. DC power (@ cos phi = 1) 8,200 W 10,250 W

MPPT voltage range 350 V / 150 ... 720 V

Max. input voltage 900 V

Max. MPPT inout current 2 x 13 A / 9.5 A 2 x 16 A / 9.5 A

Number of string inputs 1 + 1 / 1 2 + 2 / 1

Number of MPP trackers 2

DC disconnector

DC short circuit current 18 A / 14 A 22 A / 14 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 8,000 W 10,000 W

Rated current 3 x 11.6 A 3 x 14.5 A

Max. apparent power 8,900 VA 11,200 VA

Max. AC current 3 x 13.1 A 3 x 20 A

Power feed starts at 20 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 37 kg 45 kg

Dimensions (H x W x D in mm) 626 x 547 x 290

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 9000 R3-M2DXB 11000 R3-M2DXB

Speci cationsR3 inverter 14000 R3-M2 16000 R3-M2

DC Input

Max. PV power 15,200 Wp 16,900 Wp

Max. DC power (@ cos phi = 1) 13,800 W 15,350 W

MPPT voltage range 350 V / 150 ... 720 V

Max. input voltage 900 V

Max. MPPT inout current 2 x 21 A / 9.5 A 2 x 24 A / 9.5 A

Number of string inputs 2 + 2 / 1

Number of MPP trackers 2

DC disconnector

DC short circuit current 29 A / 14 A 33 A / 14 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 13,500 W 15,000 W

Rated current 3 x 19.6 A 3 x 21.7 A

Max. apparent power 15,000 VA 16,700 VA

Max. AC current 3 x 24.2 A

Power feed starts at 20 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 45 kg

Dimensions (H x W x D in mm) 626 x 547 x 290

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 14000 R3-M2DXB 16000 R3-M2DXB

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com

Standard Optional – Not available Standard Optional – Not available

Page 14: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

2726

the “Technical Guideline for Local Power Plants in Medium-voltage Power Grids” and the “Low Voltage Directive AR-N-4105”.

harge, deliver, perform and this at sunny, afforda le prices.The PLATINUM® R3-6PACK.

Warranty Outdoor IP 66

Efficiency 10 –100 kW > 100 kWShading

DUAL-X®

Three-phase

R3 inverters on one pallet, ready for delivery and quick installation. First order the mounting plates and prepare everything for installation of the PLATINUM® R3-6PACK – then simply unpack, install and connect. Done.

Cost optimised

Unrivalled performance.DUAL-X® power times six.

98,4 %

98,6 %

98,8 %

98,2 %

98,0 %

97,8 %

97,6 %

97,4 %

97,2 %

97,0 %

350 400 450 500 550 600 650 700

eta [%]

U [DC]

PLATINUM 16000 R3-M Competitor 1 Competitor 2 Competitor 3

No individual packaging means fewer packaging materials overall

Carefully coordinated with the installation process – the retaining plates are delivered separately in advance

Maximised ratings in medium-voltage

apparent power

cables via a reduction in the number of work steps

Suitable for universal use thanks to

Advantages: thanks to cost-optimised features, large-scale systems can be realised at low prices. Delivery is coordinated with the installation. So there is no need for interim storage of the inverters. The omission of individual packaging saves time during unpacking and also minimises the packaging materials that need to be disposed of. This is handy for the user and great for the environment.

Most important of all, installation and commissioning are easy and uncomplicated. The DC connection to the inverter is tailored to the requirements of large-scale systems. The communication cables are connected via a screwed cable gland with double feedthrough in just one work step.

Reactive power

Page 15: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

1 .

2.

2928

Speci cationsR3 inverter 16000 R3-M-6PACK

DC Input

Max. PV power 16,900 Wp

Max. DC power (@ cos phi = 1) 15,350 W

MPPT voltage range 350 ... 720 V

Max. input voltage 900 V

Max. MPPT inout current 2 x 24 A

Number of string inputs 1 + 1

Number of MPP trackers 1

DC disconnector

DC short circuit current 33 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 15,000 W

Rated current 3 x 21.7 A

Max. apparent power 16,700 VA

Max. AC current 3 x 24.2 A

Power feed starts at 20 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 44 kg

Dimensions (H x W x D in mm) 626 x 547 x 290

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 16000 R3-MDX-10-6PACK

Six on one pallet: the PLATINUM® R3-6PACK offers

quickly delivered.

First we deliver the mounting plates, then the R3-6PACK. Ordered and delivered in advance, you can get everything ready for immediate installation.

Always well received.The R3-6PACK.

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com

Standard Optional – Not available

Page 16: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

3130

Delivering an impressive ef ciency of 98 %.The three-phase PLATINUM® TL inverter.

Power Generating Plants Connected to the Medium Voltage Grid” and the “Low-voltage Directive AR-N-4105” as of its coming into effect as the successor directive of VDE 0126-1-1.

Warranty

Three-phase 10 –100 kWEfficiency

3 MPP-Tracker

> 100 kW

Graphics display

Outdoor IP 65 Shading

This three-phase TL inverter impresses with a peak ef-

achieved by the use of state-of-the-art SiC components in conjunction with the innovative DIVE® technology. The three-phase TL series is designed and constructed to meet the requirements of protection class IP 65 and is therefore suitable for outdoor applications. One main advantage for users is the ease with which the system can be taken into operation via the PLATINUM® network EIA 485: the inputs that are programmed at an inverter are transmitted to all networked devices. All of the key operating data can be clearly read off from the graphics

phase models ranging from 13 to 22 kW.

3 independent MPP trackers

Integrated datalogger provides storage capacity for 30 years worth of operating data

Exceptionally wide DC input voltage range

in the lower power output range

RAC-MPP® technology for rapid MPP tracking

Suitable for universal use thanks to

Free 10-year manufacturer‘s warranty

SiC (silicon carbide semiconductor technology) DIVE® (Dynamic Input Value Enhancement)

Maximised ef ciency thanks to SiC and DIVE® technology.

Specially developed for extreme outdoor weather conditions, the PLATINUM® PowerBlock system is a genuine alternative to central inverters. The compact

and robust housing offers optimum protection against rain, hail, sunshine etc.

Intelligent power undling for outdoor applications.The PLATINUM® PowerBlock.

PAC

Page 17: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

3332

Speci cationsTL inverter 13000 TL 16000 TL 19000 TL

DC Input

Max. PV power 14,700 Wp 18,000 Wp 21,300 Wp

Max. DC power (@ cos phi = 1) 12,900 W 15,900 W 18,900 W

MPPT voltage range 351 ... 710 V 349 ... 710 V 350 ... 710 V

Max. input voltage 880 V

Max. MPPT inout current 3 x 13 A 3 x 16 A 3 x 18.5 A

Number of string inputs 6 9

Number of MPP trackers 3

DC disconnector

DC short circuit current 3 x 18 A 3 x 22 A 3 x 26 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 12,360 W 15,000 W 18,000 W

Rated current 3 x 17.9 A 3 x 21.7 A 3 x 26.1 A

Max. apparent power 12,360 VA 15,000 VA 18,000 VA

Max. AC current 3 x 17.9 A 3 x 21.7 A 3 x 26.1 A

Power feed starts at 21 W 24 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11)

Standby consumption 3 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay 24 VAC / 2 A

Appliance data

Max. ef ciency

European ef ciency

Weight 81 kg 84 kg 87 kg

Dimensions (H x W x D in mm) 743 x 972 x 262

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 65

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection Fan

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 13000 TLD 16000 TLD 19000 TLD

Speci cationsTL inverter 22001 TL 22000 TL

DC Input

Max. PV power 23,000 Wp 24,000 Wp

Max. DC power (@ cos phi = 1) 20,800 W 21,600 W

MPPT voltage range 351 ... 710 V

Max. input voltage 880 V

Max. MPPT inout current 3 x 20.2 A 3 x 21 A

Number of string inputs 9

Number of MPP trackers 3

DC disconnector

DC short circuit current 3 x 28 A 3 x 29 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 20,000 W 20,700 W

Rated current 3 x 29 A 3 x 30 A

Max. apparent power 20,000 VA 20,700 VA

Max. AC current 3 x 29 A 3 x 30 A

Power feed starts at 24 W

Mains output voltage

Feed in phases / connection phases 3 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11)

Standby consumption 3 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay 24 VAC / 2 A

Appliance data

Max. ef ciency

European ef ciency

Weight 87 kg

Dimensions (H x W x D in mm) 743 x 972 x 262

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 65

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Fan

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 22001 TLD 22000 TLD

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com

Standard Optional – Not available Standard Optional – Not available

Page 18: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

3534

Uncompromisingly high performance: up to 98 % ef ciency.The single-phase PLATINUM® TL inverter.

Power Generating Plants Connected to the Medium Voltage Grid” and the “Low-voltage Directive AR-N-4105” as of its coming into effect as the successor directive of VDE 0126-1-1.

output range resulting from the combination of state-of-the-art SiC components and the innovative DIVE® technology is the key factor that contributes to the

built to meet the requirements of protection class IP 66, the single-phase TL series is exceptionally well suited to outdoor installation. One particular advan- tage in use is the ease with which these units can be connected up via the PLATINUM® network EIA 485. Thanks to the automatic master programming employed in this system, all of the device settings are trans- mitted to all connected inverters. All of the key operat-ing data can be clearly read off from the graphics display – even at night. The TL series covers seven single- phase models ranging from 3.3 to 7 kW.

Integrated phase balancing function

Integrated datalogger provides storage capacity for 30 years worth of operating data

Exceptionally wide DC input voltage range

in the lower power output range

RAC-MPP® technology for rapid MPP tracking

Suitable for universal use thanks to

Free 10-year manufacturer‘s warranty

Warranty

EfficiencySingle-phase

Data logger

< 25 kW 10 –100 kWOutdoor IP 66 Shading

SiC (silicon carbide semiconductor technology) DIVE® (Dynamic Input Value Enhancement)

Maximised ef ciency thanks to SiC and DIVE® technology.

PAC

Page 19: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

3736

Speci cationsTL inverter 3801 TL 3800 TL 4300 TL 4800 TL

DC Input

Max. PV power 4,000 Wp 4,300 Wp 4,900 Wp 5,400 Wp

Max. DC power (@ cos phi = 1) 3,480 W 3,800 W 4,300 W 4,800 W

MPPT voltage range 349 ... 710 V 350 ... 710 V 351 ... 710 V 348 ... 710 V

Max. input voltage 880 V

Max. MPPT inout current 10.5 A 11.5 A 13 A 14.5 A

Number of string inputs 2

Number of MPP trackers 1

DC disconnector

DC short circuit current 15 A 16 A 18 A 20 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 3,330 W 3,680 W 4,120 W 4,600 W

Rated current 14.5 A 16 A 17.9 A 20 A

Max. apparent power 3,330 VA 3,680 VA 4,120 VA 4,600 VA

Max. AC current 14.5 A 16 A 17.9 A 20 A

Power feed starts at 7 W

Mains output voltage

Feed in phases / connection phases 1 / 1 or 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay 24 VAC / 2 A

Appliance data

Max. ef ciency

European ef ciency

Weight 27 kg 28 kg

Dimensions (H x W x D in mm) 720 x 320 x 250

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Convection Fan

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 3801 TLD 3800 TLD 4300 TLD 4800 TLD

Speci cationsTL inverter 5300 TL 6300 TL 7200 TL

DC Input

Max. PV power 6,000 Wp 7,100 Wp 8,000 Wp

Max. DC power (@ cos phi = 1) 5,300 W 6,300 W 7,200 W

MPPT voltage range 349 ... 710 V 350 ... 710 V 351 ... 710 V

Max. input voltage 880 V

Max. MPPT inout current 16 A 18.5 A 21 A

Number of string inputs 2 3

Number of MPP trackers 1

DC disconnector

DC short circuit current 22 A 26 A 29 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 5,000 W 6,000 W 6,900 W

Rated current 21.7 A 26.1 A 30 A

Max. apparent power 5,000 VA 6,000 VA 6,900 VA

Max. AC current 21.7 A 26.1 A 30 A

Power feed starts at 7 W 8 W

Mains output voltage

Feed in phases / connection phases 1 / 1 or 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11)

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.7 ... 0.7

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Spring clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay 24 VAC / 2 A

Appliance data

Max. ef ciency

European ef ciency

Weight 28 kg 29 kg

Dimensions (H x W x D in mm) 720 x 320 x 250

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 66

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology Transformerless

Cooling Fan

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, BDEW 2008, CEI 0-21, C10/11, G83/2, G59/2, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, RD 1699/661, IEC 62109, AS 4777, AS 3100

Warranty 10 years

Type designation 5300 TLD 6300 TLD 7200 TLD

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com

Standard Optional – Not available Standard Optional – Not available

Page 20: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

3938

Setting the standard for isolated string inverters.The PLATINUM® H inverter.

The PLATINUM® H inverter offers safety, user-friendliness

inverter market. Thanks to the low weight of these units and the fact that all settings can be adjusted directly on the inverter, installation is made a lot easier and requires no additional software tools. Excellent information is provided by the graphics display and the integrated web server, which allows the unit to be monitored from a PC in real-time. The PLATINUM® H series includes four models ranging from 2.1 to 4.6 kW and is suitable for all module types.

Purely convection-cooled

Weight: 19 – 21 kg

Integrated web server

Graphics display

Free 10-year manufacturer‘s warranty

Suitable for universal use thanks to

and the “Low-voltage Directive VDE AR-N-4105”.

Web server Graphics display

Outdoor IP 65 HF transformerEfficiency

*UK and Denmark: 16 A variable current limiter Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.com

Speci cationsH inverter 2100 H 3000 H 4000 H 4600 H

DC Input

Max. PV power 2,350 Wp 3,450 Wp 4,450 Wp 5,150 Wp

Max. DC power (@ cos phi = 1) 2,100 W 3,000 W 4,000 W 4,600 W

MPPT voltage range 230 ... 480 V

Max. input voltage 600 V

Max. MPPT inout current 9.5 A 13.5 A 18 A 21 A

Number of string inputs 3

Number of MPP trackers 1

DC disconnector

DC short circuit current 14.2 A 20.2 A 27 A 31.5 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 2,000 W 2,900 W 3,800 W 4,400 W

Rated current 9 A 13 A 17 A (16 A*) 20 A (16 A*)

Max. apparent power 2,000 VA 2,900 VA 3,800 VA 4,400 VA

Max. AC current 10.5 A 15.2 A 19.7 A 23 A

Power feed starts at 7 W

Mains output voltage

Feed in phases / connection phases 1 / 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 1 W

Mains frequency

Power factor (cos phi) (ind ... cap) 0.9 ... 0.9

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Screw clamp connectors

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server

Alarm relay –

Appliance data

Max. ef ciency

European ef ciency

Weight 19 kg 21 kg

Dimensions (H x W x D in mm) 610 x 353 x 154

Operating temperature -25 ... +65 °C

Storage temperature -30 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 65

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology HF transformer

Cooling Fan

Standards / grid codes VDE 0126-1-1, VDE AR-N 4105, CEI 0-21, C10/11, G83/1, EN 50438, ÖNORM E8001-4-712, UTE C15-712-1, IEC 62109

Warranty 10 years

Type designation 2100 H 3000 H 4000 H 4600 H

Warranty

Single-phase < 25 kW 10 –100 kW

Standard Optional – Not available

Page 21: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

4140

Maximum relia ility.Even under dif cult conditions.The PLATINUM® S inverter.

Based on the circuit principle of ‘galvanic isolation’, PLATINUM® S inverters offer maximum levels of safety

ciency in the class of inverters with transformers. Even

-tions, these units are temperature-resistant and operate reliably and durably. Installation is made quick and easy by the DC and AC connectors. All of the key operating data even at night. The range contains eight models with a maximum output ranging from 2.1 to 4.6 kW. Two string inputs are provided for units with an output of 3.8 kW or higher.

Important note: In order to comply with legal require-ments, this model is no longer approved for the German market.

Low-frequency transformer: suitable for

RAC-MPP® technology for rapid MPP tracking

Optimised data transfer and networking with other PLATINUM® inverters and monitoring devices via the PLATINUM® network EIA 485

Wide range of input voltages

Integrated datalogger provides storage capacity for 30 years worth of operating data

Suitable for universal use thanks to

Free 10-year manufacturer‘s warranty

Warranty

Data logger Graphics display < 25 kW 10 –100 kWSingle-phase LF transformer

Page 22: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

4342

Speci cationsS inverter 2100 S 2800 S 3100 S 3800 S

DC Input

Max. PV power 2,300 Wp 3,200 Wp 3,450 Wp 4,200 Wp

Max. DC power (@ cos phi = 1) 2,100 W 2,800 W 3,100 W 3,800 W

MPPT voltage range 206 ... 390 V 313 ... 630 V 314 ... 630 V 315 ... 630 V

Max. input voltage 480 V 780 V

Max. MPPT inout current 9 A 12 A

Number of string inputs 1 2

Number of MPP trackers 1

DC disconnector

DC short circuit current 13 A 17 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 1,750 W 2,400 W 2,550 W 3,300 W

Rated current 7.6 A 10.4 A 11.1 A 14.3 A

Max. apparent power 1,900 VA 2,600 VA 2,800 VA 3,600 VA

Max. AC current 8.3 A 11.,3 A 12.2 A 15.7 A

Power feed starts at 13 W 14 W 18 W

Mains output voltage

Feed in phases / connection phases 1 / 1 or 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 2.5 W

Mains frequency

Power factor (cos phi) (ind ... cap) 1

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Wieland RST 3i / 5i

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay 24 VAC / 2 A

Appliance data

Max. ef ciency

European ef ciency

Weight 30 kg 35 kg 42 kg

Dimensions (H x W x D in mm) 720 x 320 x 250

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 54

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology LF transformer

Cooling Convection Fan

Standards / grid codes VDE 0126-1-1, G83/1, G59/2, EN 50438, EN 50178, ÖNORM E8001-4-712, UTE C15-712-1

Warranty 10 years

Type designation 2100 S 2800 S 3100 S 3800 S

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.comIn order to comply with legal requirements, this model is no longer approved for the German market.

Speci cationsS inverter 4300 S 4301 S 4600 S 4601 S

DC Input

Max. PV power 4,800 Wp 5,100 Wp

Max. DC power (@ cos phi = 1) 4,300 W 4,600 W

MPPT voltage range 320 ... 630 V 277 ... 470 V 320 ... 630 V 278 ... 470 V

Max. input voltage 780 V 580 V 780 V 580 V

Max. MPPT inout current 12.5 A 15 A 13 A 16 A

Number of string inputs 2

Number of MPP trackers 1

DC disconnector

DC short circuit current 18 A 21 A 18 A 22 A

Reverse polarity protection / Ground fault monitoring (isolation check)

AC Output

Rated power (@ cos phi = 1) 3,680 W 3,800 W

Rated current 16 A 16.5 A

Max. apparent power 4,050 VA 4,200 VA

Max. AC current 17.6 A 18.3 A

Power feed starts at 18 W 17 W 18 W 17 W

Mains output voltage

Feed in phases / connection phases 1 / 1 or 3

Max. permitted grid impedance |Zmax| (EN 61000-3-11) –

Standby consumption 2.5 W

Mains frequency

Power factor (cos phi) (ind ... cap) 1

Short circuit resistance / Ground fault monitoring (RCD)

Interfaces

DC connection MC4

AC connection Wieland RST 3i / 5i

RS 485 (Clamps / RJ45)

Ethernet / CAN

Integrated web server –

Alarm relay 24 VAC / 2 A

Appliance data

Max. ef ciency

European ef ciency

Weight 42 kg 43 kg 42 kg 43 kg

Dimensions (H x W x D in mm) 720 x 320 x 250

Operating temperature -20 ... +60 °C

Storage temperature -25 ... +80 °C

Relative humidity

Altitude at rated power 2,000 m / 6,560 ft

Protection degree (except digital interface) IP 54

Protection class / overvoltage category I / Type 3

Full graphic display (color / monochrome)

Storage capacity data logger 30 years

System topology LF transformer

Cooling Fan

Standards / grid codes VDE 0126-1-1, G83/1, G59/2, EN 50438, EN 50178, ÖNORM E8001-4-712, UTE C15-712-1

Warranty 10 years

Type designation 4300 S 4301 S 4600 S 4601 S

Subject to alterations. Valid as of 04/2013. More than 45 countries are currently supported. The current list is available from the download area of our homepage www.platinum-nes.comIn order to comply with legal requirements, this model is no longer approved for the German market.

Standard Optional – Not available Standard Optional – Not available

Page 23: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

4544

easier. On the basis of a postcode database, this soft-ware calculates reliable irradiation and temperature data for around 50,000 locations worldwide. In addition to this, it enables users to make a reliable choice of inverter according to grid code and country approval.

The exceptionally user-friendly software offers a selec-tion of design suggestions and performs reliable yield

collected. It is suitable for all PLATINUM® inverters –

the R3 series with DUAL-X® topology.

of features. For example via the intuitive access to an extensive module library containing around 40,000 modules. Regular updates ensure that all of the site, in-verter and module databases are constantly up-to-date.

engineers, architects, professional planners and engi-neers an extremely attractive design tool that is both free and requires no licence.

energy supply companies, as well as for public utility companies, vocational training colleges or other insti-tutions of education.

Designed for your success.The free design software PLATINUM® SolarCon g Plus.

Page 24: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

4746

PLATINUM® inverters are in use across the whole of Europe, from the UK to Greece. Customers particularly value the outstanding performance, exceptional qua-lity and ease of installation and commissioning of the multi-country devices. This list of international referen-

systems and therefore for the long-term success of solar energy.

Neuhardenberg, Brandenburg, Germany. Nearly 1,000 PLATINUM® inverters in Germany’s largest solar park.

On the site of a former military airbase, Germany‘s largest solar park (featuring 600,000 modules) has been built in

One part-section with around 91,000 modules is equipped with nearly a thousand PLATINUM® inverters. The park has been feeding electricity into the grid since March 2013. Now the plant supplies clean electricity to over 48,000 households.

Equipment: 996 22000 TL inverters

Delivering the est yield across Europe.The PLATINUM® range of inverters. References.

Copyright: Sommerreich 2012

Page 25: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

4948

Gauting, Bayern, Germany. Former gravel quarry converted into a solar park.

The new solar park in Gauting is a textbook example of how converted areas of land can be transformed into

quarry – i.e. a site with only very limited potential for re-use – a solar plant was constructed as a compen-sation measure. With a feed-in output of 1.5 MW, this

can supply clean electricity to around 600 average homes. In addition, it also saves around 1,065 tons of CO

2 emissions per year in comparison to conventional energy production.

Equipment: 6,336 modules (230 W) 66 22000 TL inverters

Impressive performance oth in the east and west.The PLATINUM® range of inverters.References.

Medvode, Gorenjska, Slovenia. Seven on one roof.

The solar system installed on the roof of a production hall has been generating electricity since April 2012. With around 175,000 kWh per year, this is the largest solar power plant to date in the local community. PLATINUM® supplied seven inverters of type 22000 TL for this.

Equipment: 672 modules (245 W) 7 22000 TL inverters

Grossenegg/Diex, Kärnten, Austria. Operational since summer 2012.

In this privately owned photovoltaic system, the sun shining over the mountains of Kärnten easily generates 4.32 kWp with the aid of a PLATINUM® TL inverter.

Equipment: 3 solar trackers, 4.32 kWp 1 4300 TL inverter

Moscow, Central Russia, Russia. Two PLATINUM® 3100 S inverters for the Russian Ministry of Industry and Trade.

Two solar systems are installed on the roof of the Russian Ministry of Industry and Trade in the centre of Moscow – each delivering an output of 3 kWp. The choice of the two corresponding inverters was made in favour of the PLATINUM® 3100 S. Since August 2011 the system has been supplying the ministry with clean electricity.

Equipment: 2 3100 S inverter

Coltau/Baia Mare, Maramures County, Romania. Operational since spring 2013 with an output of 1 MWp.

Equipment: 4,200 modules 43 22000 TL inverters 2 9000 R3-M inverters

Page 26: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

5150

Keep an eye on energy.The PLATINUM® monitoring system.

How much electricity is being produced by the solar

how high is the yield? On smaller systems? On large-scale plants?

The PLATINUM® monitoring system offers a range of professional solutions for every size of plant. It enables around-the-clock monitoring of a photovoltaic plant and provides detailed data and measurements for func-

For example, the current power output, daily/monthly/

monitored and visualised at any time. And you can enjoy mobile access from a tablet or PC or even highly professional access over the Internet.

Page 27: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

5352

Analysing performance and pro ta ility.The PLATINUM® We Master Pro.

Speci cationsDimensions (H x W x D in mm) 170 x 180 x 35

Housing Plastic housing for indoor and cabinet usage

Mounting Pedestal, wall mount, DIN rack

Protection degree IP 20

Operating temperature -20 … +75 °C

Interfaces

RS 485 (Clamps / RJ45)

Ethernet 10/100 MBit/s, RJ45 connector

Electrical data

Operating voltage 230 V

Web serverData logger E-Mail 10 –100 kWEasy to install > 100 kW

Subject to alterations. Valid as of 04/2013.

In commercial photovoltaic systems, analysis of the tech- nical performance and power output is an important part of plant monitoring, as this provides vital information

the key here is to recover the high investment and op-erating costs. Thanks to the scalability of PLATINUM® WebMaster Pro, it can be used to monitor plants with up to 1,000 PLATINUM® inverters.

PLATINUM® network EIA 485

Supports plants with up to 1,000 inverters

Automatic messaging to PC or mobile phone in the event of a fault

Access via web browser; no additional PC software required

Connection of sensors via the PLATINUM® IOBox

Connection to the ripple control receiver(s) of the grid operator via the IOBox

Standard Optional – Not available

Page 28: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

5554

Expanding PLATINUM® We Master Pro.The PLATINUM® IOBox.

In order to comply with legal requirements and technical directives, plant operators are required to provide feed-in management solutions. With its large number of inputs, the PLATINUM® IOBox offers numerous options for connection to the telecontrol engineering systems of the grid operator. In addition, these inputs are also suit-able for connecting various sensors. With the aid of the integrated network interface, PLATINUM® IOBox can be easily connected to the local grid at the plant.

10 digital inputs

6 analogue inputs, switchable measuring range

10 potential-free relay outputs

Ethernet interface

S0 input for the connection of feed-in meters

Speci cationsDimensions (H x W x D in mm) 60 x 86 x 157

Housing Plastic housing for indoor and cabinet usage

Protection degree IP 20

Operating temperature 0 … +50 °C

Interfaces

RS 485 (Clamps / RJ45)

Digital inputs 10 digital inputs (5 mA at 24 V, Low: 0 – 4 V, High 15 – 30 V), S0 meter connection, screw clamp connection

Analogue inputs

Digital outputs 10 potential-free relay contacts, max. 2 A, max. 30 VDC, screw clamp connection

Ethernet 10/100 MBit/s, RJ45 connector

Electrical data

Power supply 24 VDC

Power consumption approx. 160 mA at 24 VDC

Web server 10 –100 kWE-Mail > 100 kW

The Webmaster Pro enables monitoring of up to 50 inverters in a PLATINUM® network. With the aid of an IOBox, additional sensors and a ripple control receiver for feed-in management can be connected.

For large-scale systems with more than 50 inverters, up to 20 PLATINUM® networks can be brought together in turn via a further WebMaster Pro. In this case the additional sensors and telecontrol tech-

Plant con guration with up to 50 inverters.

Plant con guration with up to 1,000 inverters.

PLATINUM®IOBox

Irradiation sensor

Thermometer

Thermometer

Ripple control receiver

Ethernet

WebMaster Pro

PLATINUM® network (EIA485)

max. 50

EthernetEthernet

Irradiation sensorIrradiation sensor

Thermometer

Thermometer

Ripple control receiverRipple control receiver

max. 50 max. 50 max. 50max. 50

Harvester 1 Harvester 2 Harvester 3max. 20Harvester

PLATINUM®IOBox

PLATINUM®IOBox

WebMaster ProWebMaster Pro

Subject to alterations. Valid as of 04/2013.

Standard Optional – Not available

Page 29: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

5756

Internet- ased monitoring of large-scale systems.The PLATINUM® SolarPortal.

In the case of large-scale systems, it is particularly im-portant to safeguard the yield generated by the system. User-friendly monitoring and yield analysis systems are a key prerequisite for this.

PLATINUM® SolarPortal enables professional remote monitoring via the Internet. Via PLATINUM® WebMaster Pro, all of the relevant plant data is transmitted to the SolarPortal server, where the data is then stored and processed. This then highlights any faults and long-term

Global access

Integrated user administration enables

Performance monitoring via calculation of target values and actual values from weather data

For individual plants, virtual plants and plant parks

Displays the power output for different time periods, as well as temperature, voltages, currents etc.

E-mail dispatch

Data backup, user administration,

data download to PC

Technical and commercial reports, generation of individual reports

Also available as a smartphone app

E-Mail Weather dataW th d t AppA > 100 kW10 –100 kW10 100 kWWWWWWW

Page 30: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

5958

The PLATINUM® energy management concept offers a wide range of potential applications. This starts with roof top solar systems and direct use of clean elec- tricity. Via the PLATINUM® Webmaster Home and the PLATINUM® Battery, this opens up the full range of comforts of SmartHome.

With PLATINUM® Webmaster Home, it is really easy to control heat pumps, recharge an electric car, or control electrical storage heaters and many other components. User-friendly access is available via PC, tablet or via a smartphone for mobile access.

Compatibility of all of the components is ensured via the “Smart Eco Ready” seal.

Bringing energy to life.PLATINUM® energy management.

Page 31: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

6160

Analyses energy values, optimises consumption.The PLATINUM® We Master Home.

< 25 kWWWW Easy to install

E-Mail App Cloud

Web server Battery Smart meters

Speci cationsDimensions (H x W x D in mm) 170 x 180 x 35 mm

Housing Plastic housing for indoor and cabinet usage

Mounting Pedestal, wall mount, DIN rack

Protection degree IP 20

Operating temperature 0 … +50 °C

Interfaces

RS 485 (Clamps / RJ45)

Ethernet 10/100 MBit/s, RJ45 connector

Wireless interfaces Z-Wave® and EnOcean®PowerLine communication PLC Narrow Band

Electrical data

Operating voltage 230 V

into the world of Smart ECO System. It measures all of the key data for the photovoltaic system, provides infor-mation about output and generates alarms in the event of a fault. Thanks to the integrated wireless standards

EnOcean® and Z-Wave®, PLATINUM® WebMaster Home supports an almost unlimited number of components. Functional upgrades can be implemented at any time.

Monitoring of up to 5 PLATINUM® inverters via the PLATINUM® network EIA 485

Detailed measurement of output and consumption

limit according to EEG 2012

Integrated interface to the PLATINUM® Battery

Monitoring and closed-loop control for up to 5 storage systems

Representation and controlling of room scenarios

Recording and representation of individual

Suitable for upgrading with standard com-mercially available EnOcean® and Z-Wave® components (up to 400 units)

Smart Grid interfaces as standard

Optional remote reading of current meters

Subject to alterations. Valid as of 04/2013.

Standard Optional – Not available

Page 32: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

6362

Intelligent control for solar energy.PLATINUM® We Master Home.

Webmaster Home enables intelligent control of the elec- tricity generated from environmentally friendly photo- voltaic production. It supplies domestic appliances, controls heat pumps and increases living comfort by integrating dimmers for the lights or heating controls.

Surplus energy is either stored in the battery or can be used to recharge an electric car. The controls are ex-tremely easy and safe to use via the Smart Eco Cloud, or via PC or tablet visualisation.

Heating

Smart Meter

Cloud

Appliances

Solar Thermal

Solar

Home

Heat pump

App

Battery

E-Mobility

Page 33: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

6564

Delivers solar energy around the clock. The PLATINUM® Battery.

Three-phase Efficiency Graphics display Data loggerSmart Home Battery

Speci cationsBasic S M L XL XXL

Battery

Battery Type Lithium iron phosphate (LiFePo)

Usable capacity 3,2 kWh 5,7 kWh 7,1 kWh 14,3 kWh 14,3 kWh 28,7 kWh

Storage capacity 4,6 kWh 8,1 kWh 10,2 kWh 20,5 kWh 20,5 kWh 41,0 kWh

Power output

Continuous power in battery operation (25 °C)

1.800 W 2.800 W 4.100 W 4.600 W 3 x 3.200 W 3 x 4.600 W

Peak power in battery operation (1,5 s)

2.000 W 3.000 W 4.500 W 5.000 W 3 x 3.500 W 3 x 5.000 W

Maximum permitted connected power

2.400 W 3.500 W 5.000 W 6.000 W 3 x 4.000 W 3 x 6.000 W

Maximum charging power 1,275 W 1.800 W 2.550 W 4.635 W 6.180 W 7.725 W

Charging time 2,50 h 3,15 h 2,80 h 3,10 h 2,30 h 3,70 h

System power

Connection AC-coupled system (complete isolation from the mains grid in battery operation)

Switching time L1 / L2, L3 0–15 ms / 2–35 ms (parallel phase connection of L1 to L2 and L3) 0–15 ms / 0–15 ms

Standalone capability (depending on the inverter)

Grid connection 400 V AC

Generator connection 230 V AC; 5,3 kW 400 V AC; 3 x 5,3 kW

Three-phase supply (parallel phase connection from L1 to L2 and L3)

Three-phase AC current capability

Ef ciency

Number of cycles 5.000

Performance guarantee2 5 years (optional 7-year fair value replacement guarantee)

Mechanical systems / environment

Operating temperature +5 ... +25 °C

Storage temperature -10 ... +40 °C

Protection degree (DIN EN 60529) IP 21

Protection class 1

Relative humidity

Standards / grid codes EN62133:2003; EMV; UN38.3; VDE ARN 4105 (optional)

Display / operation

Weight 150 kg 180 kg 230 kg 310 kg 520 kg 900 kg

Dimensions (W x H x D in cm) 60 x 130 x 40 60 x 130 x 40 + 60 x 90 x 40

60 x 130 x 40 + 60 x 170 x 40

(3 x) 60 x 170 x 40

Option VDE ARN 4105 dimensions (W x H x D in mm)

64 x 130 x 50 (2 x) 64 x 130 x 50 (2 x) 64 x 130 x 50 (3 x) 64 x 170 x 50

Transport Transport category 2; hazardous substances class 9 as per UN 3481

Interfaces

LAN 10/100 Mbit Ethernet

Remote control PC, smartphone

Monitoring PC, smartphone

Type designation Battery Basic Battery S Battery M Battery L Battery XL Battery XXL

Subject to technical alterations. The values, performance gures and other technical data stated in this data sheet and any illustrations or drawings contained in it are only approximately indications unless we have expressly stated that the data are binding. 1 Rough guide value. Does not replace the design calculations and the associated analysis of the exact load pro le.2 Refer to the terms and conditions of the PLATINUM® Battery warranty.

As at 04/2013.

The PLATINUM® Battery stores solar energy reliably and makes it available around-the-clock. PLATINUM®

power supplies and relieves the burden on the national grid. The new around-the-clock availability of self- generated electricity along with the increase in own consumption make the PLATINUM® Battery a technol-ogy for the future and for the energy turnaround.

Thanks to the innovative lithium battery technology, the easy operation of the 7“ touch display, the interactive feature for optimising own consumption

and the standby current function, the PLATINUM® Battery offers maximum user-friendliness and quality in utilising and organising your self-generated, environ-mentally friendly electricity.

The PLATINUM® Battery is compatible with all PLATINUM® photovoltaic systems; existing systems

Basic to XXL, with a battery capacity of 4.6 kWh to 41 kWh.

Innovative lithium battery with a service life of 20 years (5,000 cycles)

Compatible with existing PLATINUM® PV systems

Emergency power feature

5-year performance guarantee (optional 7-year fair value replacement guarantee)

Standard Optional – Not available

Page 34: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

6766

Helping you to take the next step.Not just with energy affairs.The PLATINUM® PartnerCenter.

At the Wangen site we have opened our new training centre for partners, customers and employees. The PLATINUM® PartnerCenter offers a wide range of train-ing courses, seminars and workshops for operators of photovoltaic plants, planners and installation engi-neers, but also for service technicians and buyers.

The PLATINUM® PartnerCenter sees itself as a meeting place for the sharing of competence and experiences. Competent instructors offer a comprehensive and easy to understand introduction into the theory and practice of the relevant subject area. The user-focussed train-ing concept is tailored to the requirements, needs and issues of the course participants.

The – as a rule – events are divided into basic training, product training and intensive courses. In addition to the scheduled programme, it is also possible to agree dates on an individual basis. Above a certain group size it is also possible to run the training courses directly on-site at our partner or customer companies.

Page 35: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

6968

For existing experts and everyone who wants to ecome an expert.The PLATINUM® range of training courses.

What do decision-makers in electronics and photovolta-ics companies need to know about standards, laws and directives? What do planners, installation engineers or plant managers need to look out for when monitoring photovoltaic systems? When is it a good idea to use a single-phase string inverter – and when would a three-phase one be better?

Questions like these and many more are answered in the training courses offered by the PLATINUM® PartnerCenter. Experienced instructors offer compe-tent and clear information to help make the most out of every photon. In the process, not only do they cover technological aspects, but they also look at sales and service issues.

Basic training courses:PLATINUM® string inverters, single-phaseFor installation engineers and service technicians, planners, specialist retailersDuration: approx. 6 hours

PLATINUM® string inverters, three-phaseFor installation engineers and service technicians, planners, sales/marketing staffDuration: approx. 6 hours

PLATINUM® BatteryDecision-makers in electrical engineering/PV compa-nies, PV plant planners, specialist retailersDuration: approx. 5 hours

PLATINUM® MonitoringFor installation engineers and service technicians, planners and plant managers of PV plantsDuration: 2 days

Product training courses:Sales – PLATINUM® photovoltaic productsFor decision-makers in electrical engineering and PV companies, purchasers and salesmenDuration: approx. 6 hours

Sales – PLATINUM® BatteryFor decision-makers in electrical engineering and PV companies, purchasers and salesmenDuration: approx. 4 hours

Intensive training courses:Service – PLATINUM® string invertersFor PLATINUM® service partners, installation engineers, service techniciansDuration: 1 day

Customer-speci c training courses:By arrangement, also available on-site for groups of 10 or moreDuration: 1 day

A detailed listing of events with information about prior knowledge, content and training methods can be found here: www.platinum-nes.com

Page 36: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

7170

RoHS directive:Our products comply with the RoHS directive. This meansthat they do not contain hazardous substances such aslead or mercury.

Regulation on packaging:To ensure that the packaging we use for our products can also be disposed of in an environmentally friendlymanner and recycled, we take part in the dual waste disposal system and comply with the requirements ofthe regulation on packaging.

Return of end-of-life electrical and electronic equipment:To ensure that returned products are disposed of in anenvironmentally friendly manner, we are registeredin accordance with the Waste Electrical and ElectronicEquipment Directive (WEEE).

PLATINUM® is compliant with all important environmental directives:

Delivers excellent values for environmental management as well. Production, packaging and return of PLATINUM® products.

For any company that develops technology promoting the sustainable use of resources, responsible practices are an essential part of the corporate culture. We carry

of the PLATINUM® brand with all relevant environmen-tal directives.

PLATINUM® inverters are manufactured by Diehl Controls to the usual quality standards. The production has an

-cording to ISO 14001.

Page 37: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

7372

Always happy to help with advice and support.PLATINUM® sales and service.

Whether for the planning of photovoltaic systems, de-signing of plant monitoring systems or commissioning of PLATINUM® products – our experts are on hand and happy to help with advice and support.

All of our products are developed and manufactured with great care. If, despite our best efforts, you still have a problem with one of our products, the relevant PLATINUM® service department will be happy to offer fast and competent help.

SalesInternationalPLATINUM GmbHPfannerstraße 7588239 Wangen im Allgäu, GermanyTel: +49 7522 9738-0Fax: +49 7522 [email protected]

ItalyPLATINUM ItaliaVia Lancia 8/A, 39100 Bozen, ItalyTel: +39 0471 910 344 Fax: +39 0471 506 [email protected]

FranceAXUN SAS5. Av. Boula De Mareuil06600 Antibes, FranceTel: +33 492 96 96 94Fax: +33 489 73 20 [email protected]

United KingdomPV Energy Solutions Ltd.The Shieling, Ings LaneBetchford Lincolnshire LN9 6LP, United KingdomMobil: +44 780 231 46 30Tel: +44 150 753 40 [email protected]

Greece and CyprusPlatina Energy Ltd.1 Iphigenia‘s Street1055 Nicosia, CyprusTel: +30 210 667 49 89Fax: +30 210 667 13 [email protected]

ServiceInternationalPLATINUM GmbHPfannerstraße 7588239 Wangen im Allgäu, GermanyTel: +49 7522 9738-400Fax: +49 7522 9738-410 [email protected]

ItalyPLATINUM Service ItaliaVia Lancia 8/A, 39100 Bozen, ItalyTel: +39 800 91 79 69 Fax: +39 800 91 79 [email protected]

FranceAXUN SAS105 route du Pin Montard,Les Bouillides06410 Biot, FranceTel: +33 4 92 96 96 94Fax: +33 4 89 73 20 [email protected]

GreeceIN MAINT S.A.Building D21 st km Peania – Markopoulo Ave.19400 Koropi, Athen, GreeceTel: +30 210 667 49 89Fax: +30 210 667 48 [email protected]

Space for your notes

Page 38: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

Imprint

PLATINUM GmbH

Pfannerstraße 75 88239 Wangen im Allgäu, GermanyTel. +49 7522 9738-0 Fax: +49 7522 9738-100

Managing Director: Dr. Wolf Cornelius

Registration court: Ulm district court HRB 728985

Page 39: Opening up new perspectives for energy. PLATINUM ... · 8 Energy management 9 How energy management with PLATINUM® works 10–45 Inverters 12 PHOTON seal of approval 13 /CZKOKUGF

CataloguePLATINUM_EN1 05_758078_A

PLATINUM GmbH

Pfannerstraße 7588239 Wangen im Allgäu, GermanyTel: +49 7522 9738-0Fax: +49 7522 9738-100 www.platinum-nes.com


Recommended