Operating Instructions
Control unit WSE2226 USA
Index 000
Original operating instructions10993031 en USA / 09.07.2012
Page 2
TYROLIT Hydrostress AGWitzbergstrasse 18CH-8330 PfäffikonSwitzerlandTel. 0041 (1) 952 18 18Fax 0041 (1) 952 18 00
Congratulations!With a Hydrostress unit from TYROLIT, you have chosen a tried and tested piece of equipment
which has been designed and built to leading technical standards. Only genuine TYROLIT Hy-
drostress replacement parts can guarantee quality and interchangeability. If maintenance work
is neglected or carried out inexpertly we will be unable to honour our warranty obligations. Any
repair work must be carried out by trained personnel only.
Our after sales service is available to help ensure that your TYROLIT Hydrostress units remain in
perfect working order.
We hope that working with your TYROLIT unit will be a satisfying and fault-free experience.
TYROLIT Hydrostress
Copyright © TYROLIT Hydrostress
TYROLIT Hydrostress AG
Page 3
Safety
DANGER Failure to comply with the safety instructions in the «Safety Manuals / System Manuals» may re-sult in serious injuries or even death.
X Make sure that the «Safety Manuals / System Descriptions» for the relevant type of saw have been fully read and understood.
DANGER Death or serious injury can be caused by sudden start-up of the machine.
X Before switching on the system, ensure that no other persons are present in the danger ar-eas.
X Switch the system off before connecting or disconnecting cables. X On leaving the system switch off and make safe so that it cannot be switched on again.
Death or serious injury as a result of the sawing machine continuing to run after an acci-dent.
X Ensure that the EMERGENCY STOP button can be reached quickly.
Electric shock from live cables and connectors. X Switch off the control unit WSE2226 before connecting or disconnecting cables. X Ensure that the power supply is earthed and fitted with a residual current operated protec-tive device (FI) with a maximum residual current of 30mA.
Risk of fire due to incorrect mains voltage. X Make sure that the mains voltage and mains frequency correspond with the mains settings of control unit WSE2226.
Action in an emergency
X Press the EMERGENCY STOP button on the remote controller.
If the EMERGENCY STOP has been activated on the radio remote controller, the LED pilot lamp flashes quickly.
In an emergency the sawing machine can be also switched off using the main switch of control unit WSE2226.
Emergency Stop
1
1.1
TYROLIT Hydrostress AG
Page 4
Description
Main components Control unit
Main components Control unit
1 Operating hours counter 8 Main motor connection2 Main switch 9 Name plate3 Feed motor connection 10 Indicator lights4 Remote controller connection 11 Mains system selection button5 Mains connector 12 Reset button6 Water nipple / water inlet 13 Radio remote controller7 Water connection / water outlet
Main components of radio remote controller
Main components of remote controller
1 Feed potentiometer 8 Pulse switch Control unit2 On / Off Main motor 9 EMERGENCY STOP3 Main motor potentiometer 10 Indicator lights4 Water On / Off 11 Warning light (radio & battery)5 Diameter selector switch 12 Position lock switch (Traverse feed)6 Traverse feed joystick 13 Casing7 Starter switch
2
2.1
2.2
TYROLIT Hydrostress AG
Page 5
Remote controller
The remote controller can be replaced by an accumulator or a battery operated radio remote controller. The remote controller can also be operated using a cable.
Radio remote controllerThe transmitter and receiver are a pair of matched units. They cannot be used with other devices.
Transmitter = radio remote controller Receiver = control unit
Remote controller
Operating modes
Rechargeable battery operation:The interchangeable rechargeable battery is inserted in the base of the casing. The operating period with a fully charged battery is approximately 12 hours. A shorter operating period can be expected at low temperatures. The reception distance is 27 yards.
Battery operation:The battery holder is included in the scope of supply and allows operation with three 1.5 V AA batteries. The reception distance is 27 yards.
Cable operation:The cable insert is included in the scope of supply and allows connection of the remote con-troller to the control unit WSE2226. The cable length is 11 yards. Cable operation makes it possible to work in areas where radio operation is not allowed (e.g. hospitals). With cable operation all control signals are transmitted via the power cable.The rechargeable/ordinary battery holders may not be inserted in the base of the casing during cable operation.
2.3
2.4
TYROLIT Hydrostress AG
Page 6
Accessories for remote controller
The battery charger is exclusively for recharging the interchangeable rechargeable battery. The battery holder must not be inserted.
Accessories
1 2x Interchangeable rechargeable batteries No. 109843062 Rechargeable battery charger No. 10984305
Rechargeable battery charger with 10-30 VDC connection
No. 10984840
3 Remote control cable No. 109913624 Battery holder No. 109843075 Key No. 109843096 Adapter No. 10993019
During cable operation no interchangeable rechargeable battery or battery holder must be in-serted into the remote controller.
2.5
TYROLIT Hydrostress AG
Page 7
Connections
Connecting remote controller and motor connections 9 The control unit is isolated from the power supply 9 Connectors/plugs are clean 9 Cables are undamaged
X
Connecting the mains and water supply 9 The power supply is earthed and fitted with a residual current operated protective device
(max. residual current 30mA) 9 Cable cross-section is sufficient: for up to 27 yards long 5 x AWG 9, more than 27 yards long
5 x AWG7
3
3.1
3.2
TYROLIT Hydrostress AG
Page 8
Operation
Overview of operating elements
Controls
1 Position lock switch (Traverse feed) 8 Main motor potentiometer2 Water On / Off 9 Diameter selector switch3 EMERGENCY STOP 10 Feed joystick4 Pulse switch control unit 11 Main switch Control unit5 Starter switch 12 Reset button6 Feed potentiometer 13 Mains system selection button7 On / Off, main motor
4
4.1
TYROLIT Hydrostress AG
Page 9
Starting the control unit WSE2226 CAUTIONThe control unit WSE2226 can be damaged if it slips or overturns!
X Make sure that the control unit WSE2226 stands horizontally (handle at top).
9 Control unit WSE2226 is connected to the mains and the water supply. 9 The sawing machine is connected to the control unit WSE2226. 9 The remote controller EMERGENCY STOP has been deactivated. 9 The control unit WSE2226 is not exposed to direct sunlight.
Starting the control unit WSE2226
X Move the controls shown below on the remote controller to the 0 position.
Feed potentiometer (6)Starter switch (5)Feed joy stick (10)Main motor On/Off (7)
X Switch on the control unit WSE2226 using the main switch (11). X Switch on the radio remote controller using the starter switch (5).
– Warning lights (radio and battery) at first show red – An audible signal sounds simultaneously – Indicators flash coloured – Second audible signal sounds – Indicators show coloured – Warning light flashes green
X Press the pulse switch (4) on the radio remote controller briefly to the ON-position. All indicator lights except the warning light and the group alarm on the radio remote con-troller go off.
X Press the reset button (12) on the control unit. X Press the remote control pulse switch (4) briefly in the ON-position. The the control unit 'ready' lights show green.
X Open the water valve on the system supply line. X Press the Water On/Off switch (2) on the remote control unit to I.
– Water flows from the cutting tool X Press the main motor On/Off switch (7) on the remote controller to position I.
– The electric motor starts when the main motor potentiometer is in the max. position. X The control unit WSE2226 has started up and is ready for operation.
4.2
TYROLIT Hydrostress AG
Page 10
Selecting mains networkThe control unit WSE2226 is preset for a 63A power supply network (63A button lights up). It is possible to switch over to a 32A power supply network. The system automatically returns to the 63A settings when it is restarted.
X To set the power supply network to 32A press the power network selector (13), the button light goes out. Resetting must take place directly after switching on the control unit WSE2226.
Tool soft startThe control unit WSE2226 provides a facility for a tool soft start.
Proceed as follows:
X Starting the control unit WSE2226, see 4.2. X Turn the main motor (8) potentiometer to the 0 position. X Press the switch main motor (7) to I. X Select the desired output level, see 4.5. X Turn the main motor (8) potentiometer slowly to 100% power.
Selecting tool stationAfter the control unit WSE2226 has been started correctly the tool station can be selected.
Selecting the power level
Proceed as follows:
X Set the diameter selector switch to the desired tool and turn the main motor potentiometer from 0 to 100%.
X Check gear at gearbox of drive motor.
The tool stations may not be changed during operation. The tool stations are set with reference to the tool diameter for the optimum rotational speed and cutting performance.The rotational speed can be reduced using the main motor potentiometer but at the same time the power is reduced.
4.3
4.4
4.5
TYROLIT Hydrostress AG
Page 11
Power controlThe main motor and the feed motor power are controlled via the potentiometers.
Power control
Feed motor potentiometer (6)Main motor potentiometer (8)
Adjusting the feedThe feed movements are selected with the joystick.
Adjusting the feed
During the cutting process the feed speed is automatically assisted by a feed facility.
4.6
4.7
TYROLIT Hydrostress AG
Page 12
Manually adjusting the feed speed
9 Control unit WSE2226 has started
X Select the required feed speed via the feed potentiometer (6).
Feed stop So that the joystick does not have to be held in position during the travel feed motion the travel feed can be locked.
Proceed as follows:
X Push the joystick in the desired travel direction and at the same time press the locking switch (1).
X When the joystick and the locking switch are released the feed is locked.
In order to release the feed lock, move the joystick slightly in any desired direction.
Switching off the control unit WSE2226
Proceed as follows:
X Switch off electric motor (7) On / Off main motor. X Turn off cooling water, switch (2) Water On / Off. X Close water valve on control unit WSE2226. X Turn the start switch (5) on the remote controller to the 0 position. X Switch off the control unit WSE2226 using the main switch (11).
Only stop the wall saw WSE2226 using the EMERGENCY STOP function in an emergency.
CAUTIONFrost damage to control unit WSE2226!Heat damage to control unit WSE2226!
X Blow out any water if there is a risk of frost (see chapter 4.9, Blowing out water). X Direct sunlight on the WSE2226 control unit must be avoided.
Blowing out the water
9 Main switch is set to OFF
X Disconnect the mains plug. X Disconnect all water lines. X Connect blow out pump to the water nipple. X Blow out water until all of the cooling water has been removed. X Remove the pump.
4.7.1
4.7.2
4.8
4.9
TYROLIT Hydrostress AG
Page 13
Deactivating EMERGENCY STOPIf the EMERGENCY STOP is activated on the radio remote controller, the radio and battery light (8) flashes.
Deactivating EMERGENCY STOP
The following controls must be moved the 0 position:
Feed potentiometer (6).Feed joy stick (10).Main motor On/Off (7).Turn the EMERGENCY STOP button (3) clockwise. Press pulse switch control unit (4) to the ON position.
After termination of work
Proceed as follows:
X Turn the main switch on the control unit WSE2226 to the 0-position. X Withdraw the mains plug (Control unit WSE2226). X Disconnect the water hoses from control unit WSE2226. X Blow out the water from all the lines (blow out pump). X Disconnect electric cable. X Clean the control unit WSE2226, the remote controller and the cable with a damp cloth.
Cleaning using high pressure cleaning equipment is not permitted.
Products containing cleaning agent can damage parts of the control unit WSE2226, the radio remote controller and the cable.
4.10
4.11
TYROLIT Hydrostress AG
Page 14
Reacting to displays
Symbols on the control unit / remote controller
Symbols on the control unit Symbols on the remote controller
1 Service 8 Radio and battery remote control2 Control unit external fault 9 Cooling water3 Fault within the control unit 10 Group alarm4 Temperature 11 Ready for operation lights5 Mains connector6 EMERGENCY STOP7 Potentiometers
5
TYROLIT Hydrostress AG
Page 15
Power and error displays on the control unit
Symbol Response Possible cause Action
Lights up red After the first 100 operating hours, then after every 200 op-erating hours.
Carried out only by TYROLIT Hydrostress AG or an authorised representative
Lights up red Fault:- current overload- short circuit - earth fault Main motor- defective feed motor
The control unit will not start. X Check network connection. X Check cable. X Replace feed motors. X Contact TYROLIT Hydrostress AG customer service.
Lights up red Defective - main contactor- brake resistance- over current Motor- CAN fault- group fault
The control unit will not start. X Contact TYROLIT Hydrostress AG customer service. X Check network connection.
Lights up red Over heated- cooling element- control unit- main motor
The control unit will not start. X Check cooling. Wait until it can be restarted. Before starting
press the reset button. (Water cooling see page 20)
X Avoid direct contact with sun light.
Lights up red Phase missing The drive unit will not start or switches off during operation.
X Check the mains fuse in the distribution box and switch it on if necessary.
X Have the site power supply checked.
X Have the extension cables, plugs and sockets checked for faults.
Lights up red The EMERGENCY STOP has been activated- CAN fault
X Deactivate the EMERGENCY STOP. X Contact TYROLIT Hydrostress AG customer service.
Lights up red Feed potentiometer not in zero position
The control unit will not start. X Set the feed potentiometer to 0.
TYROLIT Hydrostress AG
Page 16
Power and error displays on the remote controller
Symbol Response Possible cause Action
Flashes red Rechargeable battery voltage too low
X Recharge rechargeable battery.
Flashes rapidly green
No radio connectionThe EMERGENCY STOP has been activated
X Switch on the control unit. X Defective receiver. X No receiver matched connection, see page 5.
No light shows No water flow The control unit will not start, motor does not run. X Press the cooling water button. (LED shows blue).
Lights up redor flashes
•Group alarm on the control unit
•When the pulse switch control unit is operated, the main mo-tor On/Off switch is in the po-sition On
X Observe control unit fault indicators. X Press the control unit reset button.
Lights up green The motor is ready to start
No light shows Contactor not ready X Operate control unit pulse switch.
Shows the current power rangeIdeally: At the third, orange coloured diode (In iron fourth, red diode).
TYROLIT Hydrostress AG
Page 17
Servicing and maintenance
Cleaning using high pressure cleaning equipment is not permitted.
Cleaning using high pressure cleaning equipment can damage the control unit and the remote controller.
Products containing cleaning agent can damage parts of the control unit WSE2226, the radio remote controller and the cable.
6
Maintenance and servicing table
Befo
re s
tart
ing
up On
finis
hing
w
ork
Wee
kly
Ann
ually
Aft
er fa
ults
Aft
er d
amag
e
Electrical system X Check the condition and cleanliness of electric cables, plugs/connectors and switches.
X X X X
X Check the condition and cleanliness of connections.
X X X X
Water economy X Check water lines for cleanliness and leaks.
X X X X
X Blow out the water if there is a risk of frost.
X X X
Entire WSE2226 control unit
X Clean with damp cloth no high pressure cleaner
X
Service X To be performed by TYROLIT Hydros-tress AG or an authorised workshop.
First service after 100 operating hoursFurther services after every further 200 operating hours
TYROLIT Hydrostress AG
Page 18
Faults7
Faults
Faults Possible cause Solution
Control unit does not run although the mains cable is connected
Control unit is switched off X Switch control unit on, see Chapter 4.
Mains cable is defective X Replace the mains cable.
No voltage at the power supply (build-ing site)
X Check the power supply.
Power supply phases incorrectly connected
X Check the power supply.
Phase missing See the chapter 5 entitled «Reacting to displays».
The control unit starts and then cuts out again
Building site power supply cut-off unit trips
X Check and if necessary adapt the cut-off protection. X If necessary change the power supply. X See chapter entitled «Reacting to displays».
No power, even though the control unit is running
Incorrect voltageDefective main motor
X Make sure that the control unit voltage and frequency match the mains supply specifications.
X Contact TYROLIT Hydrostress AG customer service.
The control unit suddenly cuts out
Over or under voltage X Check the power supply. Refer to fault indicator.
Cross section of power supply cable too small
X Check the power supply.
Defective plug connection X Check the plug connection. X Check the power supply.
Group alarm X Refer to fault indicator
Main motor is not running •Main motor potentiometer is in 0-position
•Defective main motor On / Off switch on remote controller
The remote controller 'ready to operate' light does not come on.
X Contact TYROLIT Hydrostress AG customer service. X Do not start control unit, see Chapter 4.2
EMERGENCY STOP activated X Deactivate EMERGENCY STOP, see Chapter 4.10.
Overheating X Check the water circuit and the plug-in couplings. X Refer to fault indicator.
No water X Switch on the water supply. X Refer to fault indicator.
Remote controller not working
Rechargeable battery or battery have too little charge
X Replace rechargeable battery and recharge or install cable operation.
X Replace batteries.
Feed potentiometer indi-cates no function
•Defective potentiometer in the remote controller
•Feed motors not connected•Defective feed motor• Joystick is in the zero position
X Contact TYROLIT Hydrostress AG customer service. X See Chapter 3.1 / 4.6 / 4.7
Feed motor fails to build up power
Remote controller potentiometer is de-fective or in the 0-position
X Contact TYROLIT Hydrostress AG customer service. X See Chapter 4.7.1
Defective cable X Contact TYROLIT Hydrostress AG customer service.
Motor fault X Contact TYROLIT Hydrostress AG customer service.
TYROLIT Hydrostress AG
Page 19
Faults
Faults Possible cause Solution
No water emerging Water line blocked X Clean the water line.
Water valve on the supply or water hose are closed
X Open the water valve.
Insufficient water pressure X Make sure that the water pressure is at least 2 bar.
Water filter is blocked X Remove filter and clean X Contact TYROLIT Hydrostress AG customer service.
Switch for the radio remote controller defective
X Contact TYROLIT Hydrostress AG customer service.
Uncontrolled water leak •Water valve on the control unit is defective
•Switch for the radio remote controller defective
X Stop water leaks using the hose water valve. X Contact TYROLIT Hydrostress AG customer service.
Group alarm on the remote controller X See chapter entitled «Reacting to displays».
TYROLIT Hydrostress AG
Page 20
Technical data
Dimensions in inch
Technical data
Parameter Value
Weight Control unit WSE2226 incl. remote controller
57.3 Ibs
Remote controller separate 4.4 Ibs
Protection class IP 65 (4.4X NEMA rating)
Connection values 380 to 420 VAC / 50 Hz / 60 Hz
Max. current consumption 38 A
Power With 32 A power supply net-work
17 kW
With 63 A power supply net-work
26 kW
Internal control voltages Controller / remote controller 24 VDC / 3.6 VDC
Feed drives 48 VDC
Main drive unit 400 VAC, 0...400 Hz
Water Cooling the control unit Water cooling the power semi-conductors
Cooling water flow rate min. 1.05 gmp at max 77 °F
Water connection min. 29psi / max. 87psi
Usage temperature Control unit WSE2226 incl. remote controller
+14°F to +104°F
8
TYROLIT Hydrostress AG
Page 21