22
Rev. 00 1011 512 En Pos: 2 /Titelseite ++++ Für alle Anleitungen ++++/Titelseite @ 1\mod_1452682577434_170.docx @ 22973 @ @ 1 Operating instructions and Spare parts list Pneumatic-fluidizing unit OptiAir CA12 Translation of the original operating instructions === Ende der Liste für Textmarke Titelblatt ===
Transcript
Page 1: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 1011 512 En

Pos: 2 /Titelseite ++++ Für alle Anleitungen ++++/Titelseite @ 1\mod_1452682577434_170.docx @ 22973 @ @ 1

Operating instructions and Spare parts list

Pneumatic-fluidizing unit OptiAir CA12

Translation of the original operating instructions === Ende der Liste für Textmarke Titelblatt ===

Page 2: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

Pos: 4 /Copyright ++++ Für alle Anleitungen ++++/Copyright @ 1\mod_1452682618687_170.docx @ 22999 @ @ 1

Documentation OptiAir CA12

© Copyright 2016 Gema Switzerland GmbH

All rights reserved.

This publication is protected by copyright. Unauthorized copying is prohibited by law. No part of this publication may be reproduced, photocopied, translated, stored on a retrieval system or transmitted in any form or by any means for any purpose, neither as a whole nor partially, without the express written consent of Gema Switzerland GmbH.

MagicCompact, MagicCylinder, MagicPlus, MagicControl, OptiFlex, OptiControl, OptiGun, OptiSelect, OptiStar and SuperCorona are registered trademarks of Gema Switzerland GmbH.

OptiFlow, OptiCenter, OptiMove, OptiSpeeder, OptiFeed, OptiSpray, OptiSieve, OptiAir, OptiPlus, OptiMaster, MultiTronic, EquiFlow, Precise Charge Control (PCC), Smart Inline Technology (SIT) and Digital Valve Control (DVC) are trademarks of Gema Switzerland GmbH.

All other product names are trademarks or registered trademarks of their respective holders.

Reference is made in this manual to different trademarks or registered trademarks. Such references do not mean that the manufacturers concerned approve of or are bound in any form by this manual. We have endeavored to retain the preferred spelling of the trademarks, and registered trademarks of the copyright holders.

To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of publication. Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice.

For the latest information about Gema products, visit www.gemapowdercoating.com.

For patent information, see www.gemapowdercoating.com/patents or www.gemapowdercoating.us/patents.

Printed in Switzerland

Gema Switzerland GmbH Mövenstrasse 17 9015 St.Gallen Switzerland

Phone: +41-71-313 83 00 Fax.: +41-71-313 83 83

E-mail: [email protected]

=== Ende der Liste für Textmarke Copyright ===

Page 3: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Table of contents 3

Pos: 6 /Inhaltsverzeichnis ++++ Für alle Anleitungen ++++/Inhaltsverzeichnis @ 1\mod_1452682645125_170.docx @ 23026 @ @ 1

Table of contents

About this instructions 5

General information ................................................................................................ 5 Keeping the Manual ................................................................................................ 5 Safety symbols (pictograms) ................................................................................... 5 Presentation of the contents ................................................................................... 6

Figure references in the text ...................................................................... 6

Safety 7

Intended use ........................................................................................................... 7 Product specific security regulations ...................................................................... 7

Product description 9

Field of application .................................................................................................. 9 Reasonably foreseeable misuse ................................................................ 9

Technical data ......................................................................................................... 9 Pneumatic data .......................................................................................... 9 Dimensions ................................................................................................ 9

Structure ................................................................................................................ 10 Principle of operation ............................................................................................ 10

Assembly / Connection 11

Connecting the Pneumatic-fluidizing unit .............................................................. 11

Operation 11

Setting the fluidization ........................................................................................... 12 Setting the Airmover air ........................................................................................ 13

Spare parts list 15

Ordering spare parts ............................................................................................. 15 OptiAir CA12-A (for use with HF50/HF100 powder hopper) – spare parts list ..... 16 OptiAir CA12-A (for use with HF50/HF100 powder hopper) – spare parts .......... 17 OptiAir CA12-B (for use with HF150/HF200 powder hopper) – spare parts list ... 18 OptiAir CA12-B (for use with HF150/HF200 powder hopper) – spare parts ........ 19

=== Ende der Liste für Textmarke Inhaltsverzeichnis ===

Pos: 8 /Steuermodule ++++ Für alle Anleitungen ++++/++++++++ Seitenumbruch ++++++++ @ 1\mod_1452608869481_0.docx @ 22162 @ @ 1

Page 4: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

4 About this instructions OptiAir CA12

Pos: 10 /Überschriften ++++ Für alle Anleitungen ++++/1. Ebene/Über diese Anleitung @ 1\mod_1452608729182_170.docx @ 22133 @ 1 @ 1

Page 5: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 About this instructions 5

About this instructions

Pos: 11 /Kapitel/Über diese Anleitung ++++ Für alle Anleitungen ++++/Allgemeines @ 1\mod_1452610204952_170.docx @ 22326 @ 2 @ 1

General information This operating manual contains all important information which you require for the working with the OptiAir CA12. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system.

Information about the functional mode of the individual system components should be referenced in the respective enclosed documents.

Pos: 12 /Kapitel/Über diese Anleitung ++++ Für alle Anleitungen ++++/Anleitung aufbewahren @ 1\mod_1452679788745_170.docx @ 22537 @ 2 @ 1

Keeping the Manual Please keep this Manual ready for later use or if there should be any queries.

Pos: 13 /Kapitel/Über diese Anleitung ++++ Für alle Anleitungen ++++/Sicherheitssymbole (Piktogramme) @ 1\mod_1452781244678_170.docx @ 23723 @ 2 @ 1

Safety symbols (pictograms)

The following warnings with their meanings can be found in the Gema operating instructions. The general safety precautions must also be followed as well as the regulations in the relevant operating instructions.

DANGER

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

Page 6: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

6 About this instructions OptiAir CA12

ATTENTION

Indicates a potentially harmful situation. If not avoided, the equipment or something in its surrounding may be damaged.

ENVIRONMENT

Indicates a potentially harmful situation which, if not avoided, may have harmful consequences for the environment.

Notice

<Useful information, tips, etc.>

Pos: 14 /Kapitel/Über diese Anleitung ++++ Für alle Anleitungen ++++/Darstellung des Inhalts @ 1\mod_1452784296568_170.docx @ 23802 @ 23 @ 1

Presentation of the contents

Figure references in the text

Figure references are used as cross references in the descriptive text.

Example:

"The high voltage (H) created in the gun cascade is guided through the center electrode."

Pos: 16 /Überschriften ++++ Für alle Anleitungen ++++/1. Ebene/Sicherheit @ 1\mod_1452680111994_170.docx @ 22563 @ 1 @ 1

Page 7: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Safety 7

Safety

Pos: 17 /Kapitel/Sicherheit/Bestimmungsgemässe Verwendung/Bestimmungsgemässe Verwendung @ 1\mod_1452781705430_170.docx @ 23749 @ 2 @ 1

Intended use

– This product is built to the latest specification and conforms to the recognized technical safety regulations and is designed for the normal application of powder coating.

– Any other use is considered non-compliant. The manufacturer shall not be liable for damage resulting from such use; the user bears sole responsibility for such actions. If this product is to be used for other purposes or other substances outside of our guidelines then Gema Switzerland GmbH should be consulted.

– Observance of the operating, service and maintenance instructions specified by the manufacturer is also part of conformity of use. This product should only be used, maintained and started up by trained personnel, who are informed about and are familiar with the possible hazards involved.

– Start-up (i.e. the execution of intended operational tasks) is forbidden until it has been established that this product has been set up and wired according to the guidelines for machinery. The standard "Machine safety" must also be observed.

– Unauthorized modifications to the product exempt the manufacturer from any liability from resulting damage.

– The relevant accident prevention regulations, as well as other generally recognized safety regulations, occupational health and structural regulations are to be observed.

– Furthermore, the country-specific safety regulations also must be observed.

Pos: 18 /Kapitel/Sicherheit/Produktspezifische Sicherheitshinweise/Produktspezifische Sicherheitshinweise @ 1\mod_1452782586999_170.docx @ 23776 @ 2 @ 1

Product specific security regulations

– This product is a constituent part of the equipment and is therefore integrated in the system's safety concept.

– If it is to be used in a manner outside the scope of the safety concept, then corresponding measures must be taken.

– The installation work to be done by the customer must be carried out according to local regulations.

Page 8: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

8 Safety OptiAir CA12

– It must be ensured, that all components are earthed according to the local regulations before start-up.

Notice

For further security information, see the more detailed Gema safety regulations!

Pos: 19 /Warnhinweise ++++ Für alle Anleitungen ++++/WARNUNG/Arbeiten ohne Betriebsanleitung @ 1\mod_1452779639975_170.docx @ 23690 @ @ 1

WARNING

Working without operating instructions

Working without operating instructions or with individual pages from the operating instructions may result in damage to property and personal injury if relevant safety information is not observed.

– Before working with the device, organize the required documents and read the section "Safety regulations".

– Work should only be carried out in accordance with the instructions of the relevant documents.

– Always work with the complete original document.

Pos: 21 /Überschriften ++++ Für alle Anleitungen ++++/1. Ebene/Produktbeschreibung @ 1\mod_1452609707048_170.docx @ 22297 @ 1 @ 1

Page 9: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Product description 9

Product description

Pos: 22 /Kapitel/Produktbeschreibung/Equipment and Controls/Air Controls/Anwendungsgebiet CA12 @ 1\mod_1461239846679_170.docx @ 27598 @ 2 @ 1

Field of application The Pneumatic-fluidizing unit distributes the compressed air to the gun control units and regulates the fluidizing air and Airmover pressure.

Pos: 23 /Kapitel/Produktbeschreibung/Equipment and Controls/Air Controls/vorhersehbare Fehlanwendung-CA12 @ 1\mod_1461574020294_170.docx @ 29348 @ 3 @ 1

Reasonably foreseeable misuse

– Use with insufficient compressed air quality

– Input pressure too low Pos: 24 /Kapitel/Produktbeschreibung/Equipment and Controls/Air Controls/Technische Daten CA12 @ 1\mod_1461240247601_170.docx @ 27624 @ 233 @ 1

Technical data

Pneumatic data

OptiAir CA12

Input pressure 7-10 bar / 101-145 psi

Compressed air consumption dependent on the number of connected guns

Water vapor content max. 1.3 g/m³

Oil content max. 0.1 mg/m³

Protection type IP54

Approvals II 3D

Dimensions

OptiAir CA12

Width 173 mm

Height 177 mm

Depth 290 mm

Weight 2.2 kg (CA12-A)

2.8 kg (CA12-B)

Pos: 25 /Kapitel/Produktbeschreibung/Equipment and Controls/Air Controls/Aufbau CA12 @ 1\mod_1461240624493_170.docx @ 27734 @ 2 @ 1

Page 10: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

10 Product description OptiAir CA12

Structure

fig. 1: Structure

1 Pressure indicator for fluidizing air

2 Prefluidization press button

3 Pressure indicator for Airmover

4 Pressure regulator for Airmover

5 Pressure regulator for fluidizing air

Pos: 26 /Kapitel/Produktbeschreibung/Equipment and Controls/Air Controls/Funktionsprinzip CA12 @ 1\mod_1461243031932_170.docx @ 27760 @ 2 @ 1

Principle of operation The prefluidization is switched on manually by pressing the Prefluidization key. The fluidization operates directly by connecting the Pneumatic-fluidizing unit to the compressed air.

The fluidizing air produces an overpressure in the powder hopper. This overpressure prevents the powder supply and must be eliminated. For this purpose an Airmover is installed on the powder hopper, which extracts, similarly as an injector, the overpressure and the powder mixed with air.

Therefore, the Airmover produces a depression in the powder hopper. The air volume, which can be extracted by the Airmover, depends on the powder hopper size and the fluidizing air volume.

Pos: 28 /Überschriften ++++ Für alle Anleitungen ++++/1. Ebene/Montage / Anschluss @ 1\mod_1452680195484_170.docx @ 22617 @ 1 @ 1

Page 11: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Assembly / Connection 11

Assembly / Connection

Pos: 29 /Kapitel/Montage / Anschluss/Equipment and Controls/Air Controls/Anschliessen der CA12 @ 1\mod_1461243417741_170.docx @ 27786 @ 2 @ 1

Connecting the Pneumatic-fluidizing unit The Pneumatic-fluidizing unit is delivered ready-to-use by the manufacturer. Just a few hoses must be connected additionally.

NOTICE

The compressed air must be free of oil and water!

The Pneumatic-fluidizing unit is connected as follows:

1. Connect the fluidizing air hose to the output 3 and to the corresponding connection on the powder hopper

2. Connect the Airmover hose to the output 1 and to the Airmover

3. Connect the compressed air supply hose to the connection 2 (Air supply IN)

fig. 2: Connections

1 Output to the Airmover

2 Compressed air main connection

3 Fluidizing air connection to the powder hopper

Pos: 31 /Überschriften ++++ Für alle Anleitungen ++++/1. Ebene/Bedienung / Betrieb @ 1\mod_1452680450846_170.docx @ 22698 @ 1 @ 1 Operation Pos: 32 /Kapitel/Bedienung / Betrieb/Equipment and Controls/Air Controls/Fluidisierung einstellen-CA12 @ 1\mod_1461246415759_170.docx @ 27814 @ 2 @ 1

Page 12: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

12 Assembly / Connection OptiAir CA12

Setting the fluidization The powder fluidization depends on the powder type, the air humidity and the ambient temperature.

The Pneumatic-fluidizing unit contains a push button for the prefluidization, as well as a pressure regulator and a pressure gauge for fluidizing air and Airmover.

Notice

The Pneumatic-fluidizing unit is connected to a 7-10 bar compressed air circuit.

The fluidization is set as follows:

1. Connect the main compressed air supply and open it.

The compressed air flows now through the Pneumatic-fluidizing unit. The fluidization operates immediately when connecting the Pneumatic-fluidizing unit to the compressed air

2. Adjust the compressed air to 6 bar on the pressure reducing valve (5)

3. Check the powder fluidization in the powder hopper.

If the powder does not "boil" regularly, push the prefluidization button (2) several times briefly. The compressed air of the prefluidization will "loosen up" the powder.

If the powder begins to "boil", adjust the fluidizing air with the corresponding pressure regulator in such a way that the "boiling" spreads evenly on the powder surface.

The fluidizing air pressure is monitored on the pressure gauge (1).

fig. 3:

Pos: 33 /Steuermodule ++++ Für alle Anleitungen ++++/++++++++ Seitenumbruch ++++++++ @ 1\mod_1452608869481_0.docx @ 22162 @ @ 1

Page 13: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Assembly / Connection 13

Pos: 34 /Kapitel/Bedienung / Betrieb/Equipment and Controls/Air Controls/Airmover-Luft einstellen-CA12 @ 1\mod_1461249063165_170.docx @ 27843 @ 2 @ 1

Setting the Airmover air The Airmover air is to be set, when a powder cloud rises over the powder surface and flows out through the powder hopper openings.

1. Set the Airmover air pressure on the pressure reducing valve (4) and monitor it on the pressure gauge (3).

2. Increase the pressure so far, until no more powder flows out of the powder hopper.

Notice

If these settings are once fixed, they can be left also when work interruptions take place. A reset of the adjusted values is thereby not necessary.

3. Switch on the OptiFlex A1 control system with the main switch

4. Set and/or operate the guns (see therefore the powder gun and gun control unit operating instructions)

Pos: 36 /Überschriften ++++ Für alle Anleitungen ++++/1. Ebene/Ersatzteilliste @ 1\mod_1452680828087_170.docx @ 22833 @ 1 @ 1

Page 14: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

14 Assembly / Connection OptiAir CA12

Page 15: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Spare parts list 15

Spare parts list

Pos: 37 /Kapitel/Ersatzteilliste/Bestellen von Ersatzteilen @ 1\mod_1456410477712_170.docx @ 27363 @ 2 @ 1

Ordering spare parts When ordering spare parts for powder coating equipment, please indicate the following specifications:

– Type and serial number of your powder coating equipment

– Order number, quantity and description of each spare part

Example:

– Type OptiGun GA03 automatic powder gun

Serial number 1234 5678

– Order no. 203 386, 1 piece, Clamp – Ø 18/15 mm

When ordering cable or hose material, the required length must also be given. The spare part numbers of this bulk stock is always marked with an *.

Wearing parts are always marked with a #.

All dimensions of plastic hoses are specified with the external and internal diameter:

Example:

Ø 8/6 mm, 8 mm outside diameter (o/d) / 6 mm inside diameter (i/d)

ATTENTION

Use of non-original Gema spare parts

When using the spare parts from other manufacturers the explosion protection is no longer guaranteed. If any damage is caused by this use all guarantee claims become invalid!

– Only original Gema spare parts should be used!

Pos: 38 /Steuermodule ++++ Für alle Anleitungen ++++/++++++++ Seitenumbruch ++++++++ @ 1\mod_1452608869481_0.docx @ 22162 @ @ 1

Page 16: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

16 Spare parts list OptiAir CA12

Pos: 39 /Kapitel/Ersatzteilliste/Equipment and Controls/Air Controls/OptiAir CA12-A – Ersatzteilliste @ 1\mod_1461252532547_170.docx @ 27869 @ 2 @ 1

OptiAir CA12-A (for use with HF50/HF100 powder hopper) – spare parts list

OptiAir CA12-A Pneumatic-fluidizing unit – complete (without pos. 18) 1013 442

1 Elbow joint – 1/4", Ø 6 mm 265 691

2 Shuttle valve – 1/4" 259 217

5 Push button 1009 102

6 Connection sleeve – 1/4", Ø 6 mm 233 404

7 Pressure gauge – 0-6 bar, 1/8" 1003 300

8 Elbow joint – 1/8", Ø 6 mm 254 061

9 Pressure regulator – 0.1-4 bar, G1/4" 1009 101

10 Front frame – complete 1007 048

12 Adjusting elbow – Ø 6-4 mm 261 181

16 Adapter nipple – 3/8"-1/4" 202 550

17 Nut with kink protection for pos. 18 (not shown) 201 316

18 Plastic tube (Airmover air) – Ø 8/6 mm (not shown) 103 756*

# Wearing part

* Please indicate length Pos: 40 /Steuermodule ++++ Für alle Anleitungen ++++/++++++++ Seitenumbruch ++++++++ @ 1\mod_1452608869481_0.docx @ 22162 @ @ 1

Page 17: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Spare parts list 17

Pos: 41 /Kapitel/Ersatzteilliste/Equipment and Controls/Air Controls/OptiAir CA12-A – Ersatzteile @ 1\mod_1461253287920_170.docx @ 27896 @ 2 @ 1

OptiAir CA12-A (for use with HF50/HF100 powder hopper) – spare parts

fig. 4:

Pos: 42 /Steuermodule ++++ Für alle Anleitungen ++++/++++++++ Seitenumbruch ++++++++ @ 1\mod_1452608869481_0.docx @ 22162 @ @ 1

Page 18: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

18 Spare parts list OptiAir CA12

Pos: 43 /Kapitel/Ersatzteilliste/Equipment and Controls/Air Controls/OptiAir CA12-B – Ersatzteilliste @ 1\mod_1461253688736_170.docx @ 27949 @ 2 @ 1

OptiAir CA12-B (for use with HF150/HF200 powder hopper) – spare parts list

OptiAir CA12-B Pneumatic-fluidizing unit – complete (without pos. 18) 1013 443

1 Elbow joint – 1/4", Ø 6 mm 265 691

2 Shuttle valve – 1/4" 259 217

3 Sealing plug – 1/8" 258 687

4 Screw-in nipple – 3/8", Ø 8 mm 259 659

5 Push button 1009 102

6 Connection sleeve – 1/4", Ø 6 mm 233 404

7 Pressure gauge – 0-6 bar, 1/8" 1003 300

8 Elbow joint – 1/8", Ø 6 mm 254 061

9 Pressure regulator – 0.1-4 bar, G1/4" 1009 101

10 Front frame – complete 1007 048

11 Elbow joint – 3/8", Ø 8 mm 240 010

12 Adjusting elbow – Ø 6-4 mm 261 181

13 Pressure regulator – 3/8", remote controlled 244 384

14 Elbow joint – 1/8"-1/8" 235 733

15 Adapter nipple – 1/8"-1/4" 202 606

17 Nut with kink protection for pos. 18 (not shown) 201 316

18 Plastic tube (Airmover air) – Ø 8/6 mm (not shown) 103 756*

# Wearing part

* Please indicate length Pos: 44 /Steuermodule ++++ Für alle Anleitungen ++++/++++++++ Seitenumbruch ++++++++ @ 1\mod_1452608869481_0.docx @ 22162 @ @ 1

Page 19: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Spare parts list 19

Pos: 45 /Kapitel/Ersatzteilliste/Equipment and Controls/Air Controls/OptiAir CA12-B – Ersatzteile @ 1\mod_1461253688536_170.docx @ 27922 @ 2 @ 1

OptiAir CA12-B (for use with HF150/HF200 powder hopper) – spare parts

fig. 5:

=== Ende der Liste für Textmarke Inhalt ===

Page 20: Operating instructions and Spare parts list Pneumatic ...
Page 21: Operating instructions and Spare parts list Pneumatic ...

Rev. 00 02/16

OptiAir CA12 Index 21

Pos: 47 /Index ++++ Für alle Anleitungen ++++/Index @ 1\mod_1452682674446_170.docx @ 23053 @ @ 1

Index

A

About this instructions ........................................ 5 Assembly .......................................................... 11

C

Connection ....................................................... 11

D

Dimensions ........................................................ 9

F

Figure references in the text .............................. 6

I

Intended use ...................................................... 7

O

Operation ......................................................... 11

P

Pictograms ......................................................... 5 Pneumatic data .................................................. 9 Presentation of the contents .............................. 6 Product description ............................................ 9 Product specific security regulations ................. 7

S

Safety ................................................................. 7 Safety symbols .................................................. 5 Spare parts list ................................................. 15

T

Technical data ................................................... 9

=== Ende der Liste für Textmarke Index ===

Page 22: Operating instructions and Spare parts list Pneumatic ...

Rev. 00

Pos: 49 /Rückseite ++++ Für alle Anleitungen ++++/Rückseite @ 1\mod_1452682695293_170.docx @ 23080 @ @ 1

=== Ende der Liste für Textmarke Rückseite ===


Recommended