+ All Categories
Home > Documents > Operating instructions - ifm · LR DEVICE 3 1 Preliminary note This document serves for setup and...

Operating instructions - ifm · LR DEVICE 3 1 Preliminary note This document serves for setup and...

Date post: 15-Feb-2019
Category:
Upload: vudung
View: 221 times
Download: 0 times
Share this document with a friend
21
Operating instructions LR DEVICE Version 1.1 706434 / 01 04 / 2017 UK
Transcript

Operating instructions

LR DEVICE Version 1.1

7064

34 /

01

04 /

2017

UK

LR DEVICE

2

Contents1 Preliminary note � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3

1�1 Symbols used� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 32 Safety instructions � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 33 System requirements � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3

3�1 PC hardware � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 33�2 PC software � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 43�3 Hardware accessories � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4

4 Functions and features � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 45 Software � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4

5�1 Install program on the hard disk � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 55�2 Software upgrade � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 55�3 Language selection � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5

6 Program start � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 66�1 Limited software � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 66�2 Licensing procedures � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 66�3 Functions depending on the licence keys used � � � � � � � � � � � � � � � � � � � � � 76�4 Connection of the hardware � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 76�5 Start screen � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8

7 Online setup by network � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 98 Online setup by USB IO-Link Master � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �11

8�1 Memory plug parameter setting � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 128�2 Display of the data stored on the memory plug � � � � � � � � � � � � � � � � � � � � 13

9 Cockpit � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 159�1 Symbols used for measurement locations / data sources � � � � � � � � � � � � 16

10 Offline setup� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 1711 Update IODD / device catalogue � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 1812 Fault correction� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 20

Licences and trademarksMicrosoft®, Windows®, Windows XP® and Windows Vista® are registered trademarks of Microsoft Corporation�All trademarks and company names used are subject to the copyright of the respective companies�

UK

LR DEVICE

3

1 Preliminary noteThis document serves for setup and use of the LR DEVICE software from ifm�

1.1 Symbols used► Instructions> Reaction, result[…] Designation of keys, buttons or indications→ Cross-reference

Important note Non-compliance may result in malfunction or interference�Information Supplementary note

2 Safety instructionsPlease read the operating instructions before using the software�Ensure that the software is suitable for your application / sensors without any restrictions�If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur� That is why installation, set-up and maintenance of the article must only be carried out by qualified personnel authorised by the machine operator�Non-observance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can affect the safety of operators and machinery�The installation and connection must comply with the applicable national and international standards� Responsibility lies with the person installing the software�Changes to the source code or to individual components of the software which are not explicitly described in the instructions lead to the loss of the right to benefit from the support provided by ifm electronic gmbh�

3 System requirements3.1 PC hardware

– Min� 2 GB working memory – Min� 5 GB freely available hard disc memory – 1 free USB 2�0 port – CPU Intel dual core 2�0 GHz

LR DEVICE

4

3.2 PC software – Operating system Microsoft Windows 7 SP1, Windows 8�1 und Windows

10, Windows Server 2008 R2 SP1, Windows Server 2012, Windows Server 2012 R2, Windows Server 2016�

– Webbrowser Chrome, Firefox, Internet Explorer 11, Microsoft Edge�

3.3 Hardware accessories – Network accessories to connect computer with network� – Optional USB IO-Link master (incl� plug-in power supply and M12

connection cable)�

Hardware accessories are not included in scope of delivery�

4 Functions and featuresUse of the LR DEVICE software offers the following possibilities:

● Parameter setting of IO-Link master und devices – By network – Devices "point-to-point" by USB IO-Link master

● Online and offline setup of ifm IO-Link master and devices – Parameter setting – Loading of parameters from an IO-Link sensor – Saving and loading of sets of parameters in / from a file – Writing of parameters to IO-Link devices – Support of IO-Link actuators

● Graphic representation of process values – Evaluation of measured values – Export of displayed measured values

The LR DEVICE software can be used for simple and efficient parameter setting of IO-Link sensors� Use of the software is to reduce set-up costs, increase the uptime of systems and ensure an easy display / evaluation of measured value curves during set-up or maintenance interventions�

5 SoftwareThe LR DEVICE program is installed on the PC by means of the "Linerecorder Device�exe" file�

UK

LR DEVICE

5

If an LR SENSOR version is installed on the PC, it will be upgraded to LR DEVICE upon approval� Installation of LR SENSOR and LR DEVICE on an operating system is not possible�

Administrator rights are required for set-up and operation of the software� Contact your administrator or responsible IT staff�

5.1 Install program on the hard disk ► Start the file "Linerecorder Device�exe" with a double click�

> The start menu opens� The licence conditions are displayed� ► Agree to the licence conditions, start the installation of the program and follow the instructions of the installation routine�

> The program is installed� ► End the installation dialogue after successful installation�

5.2 Software upgrade ► Ask your ifm contract partner for available upgrades� ► Follow the installation routine as in → 5.1�

> The licence key remains valid�Installation of LR Sensor and LR DEVICE on an operating system is not possible� The system signals an error while trying to install the LR DEVICE�

5.3 Language selectionThe interface language depends on the language selected in your browser� The following example shows how to change the language in Firefox (recommended browser):

► Click on "Open menu" in the browser bar� ► Select "Options"� ► Open the "Content" tab� ► Click on [Choose] in the "Languages" category� ► Select a language (which is then shown in blue)� ► Place the selected language in the 1st line using [Move Up]� ► Click on [OK]� ► Restart the browser�

Language versions of operating instructions → www.ifm.com

LR DEVICE

6

6 Program start6.1 Limited softwareThe LR DEVICE Software can be used in a limited environment without a licence key�Functions of the limited environment:

● IO-Link Master will be displayed including network address ● Read parameters from master ● By "point-to-point" connection read parameters from device ● Edit parameters on the LR DEVICE surface (offline) ● Write data to a master or device not possible ● Cockpit functions for monitoring devices are provided without any restrictions,

only possible using "point-to-point" connection�

6.2 Licensing proceduresThe licence key is required by click on [limited] information� The licence key consists of:

– Licence number – License

The licence key is included with the delivery� For the version QA0011, it is indicated on the inside of the packaging� The licence key of the download version QA0012 is advised by email�

UK

LR DEVICE

7

6.3 Functions depending on the licence keys used

Licence

Reading IO-Link data via USB IO-Link master or network

Writing data to network IO-Link master via network

Writing data to IO-Link device via USB IO-Link master

Writing data to IO-Link device via network IO-Link master

LIMITED YES YES NO NOLR SENSOR YES YES YES NOLR DEVICE YES YES YES YES

6.4 Connection of the hardwareBy using network connection:

► Connect the PC and the network with a suitable network cable�By using USB IO-Link master:

► Connect the USB IO-Link master to the PC and the plug-in power supply� ► Connect the USB IO-Link master to the IO-Link sensor via the M12 connection cable�

► For sensors with display or indication of the readiness for operation, check whether the unit is in operation�

The voltage supply of the respective device is established via the USB IO-Link master�

LR DEVICE

8

6.5 Start screen > The start screen is displayed according to the language settings in the browser

(language selection → 5.3)

① Parameter setting: Parameter setting of IO-Link masters and devices

② Cockpit: Display mode of all measured values available online�

③ Device catalogue: Fast access to IODD files for offline parameter setting via article no�

④< :

>:

Hide menu catalogue, ONLINE and OFFLINE

Show menu

⑤ ONLINE: Detected interface / detected device is displayed

⑥ OFFLINE: Selection list from manufacturer to article no�Activate IODD file for offline parameter setting

⑦ Read from device: Reading of parameters from master or connected device�

⑧ Write to device: Writing of set parameter values to master or device�

⑨ Write to multiple selected devices: Function like (8), additionally writing to multiple identified and selected devices in the offline mode is possible�

⑩ Load parameters from a file: Upload of stored parameter settings with the file extension "�lrp" from a directory�

⑪ Save parameters to a file: Saving of parameter values to a file in the format �lrp�

⑫ Searching for updates: When the icon is pink, new IODD files are available and can be downloaded from the internet�

⑬ Header with information and an image of the read device:

device name; manufacturer, device ID; serial no�; device type; hardware / firmware revision (internal version ID), device status (only for online setup)�

UK

LR DEVICE

9

General icons: A print preview of the displayed parameters is opened in a separate browser window� It contains the name of the parameter, the current and preset (factory set) parameter value, min and max setting value of the parameter and the short description of the parameter� In the print preview, remarks can be added and printed� Access the online user manual in a separate browser window�

7 Online setup by network > The PC is connected to network ► Click on [ ]�

> Parameters of the connected IO-Link masters are loaded into the software�

> ONLINE ① shows all detected IO-Link masters > In this case the network address ② of the detected IO-Link masters are

displayed ► Network address of the PC must be match in the in the "Network and Sharing Center" in Windows!

LR DEVICE detect all IO-Link masters in the network with divergent network addresses to the PC address� Parameter setting in this case is not possible�

► Click on [ ]�

LR DEVICE

10

> In the case [Profinet name] ③ of the IO-Link masters are displayed the network settings are O�K� �

► Click on IO-Link Master ④

> Paramter settings ⑤ of the IO-Link master are displayed� > Network address [IP address], [Profinet name] or other parameter are

adjustable� Additional information are available in the operating instructions of the IO-Link masters�

> [Port] ⑥ shows the used ports of the IO-Link master� ► Click on [Port 3] ⑦�

> The paramter list of the connected IO-Link device will be displayed�

> [All] ⑧ is always preset� > All parameters ⑨ are displayed and can be edited� ► For a targeted input of parameters, select the requested category ⑩. ► Click on [ ] for writing to the device�

UK

LR DEVICE

11

Funktion [Auto refresh] opens a new column "Device value" and dispay the stored parameter of the unit� To save data on the unit click on [ ]�

8 Online setup by USB IO-Link Master > The IO-Link device was connected to the PC via the IO-Link master� ► Click on [ ]�

> Parameters of the connected sensor are loaded into the software�

> ONLINE ① shows the used interface / the detected devices > The setting [All] ② is always preset� > All parameters ③ are displayed and can be edited� ► For a targeted input of parameters, select the requested category ④

Example: ► Select [Fault Configuration Output 1] ⑤

> Parameters in the category Fault Configuration Output 1 are shown and can be edited�

LR DEVICE

12

► Select [FOU1] parameter from the list ⑤ (other parameters are edited via input fields)�

> The pen symbol ⑥ indicates an edited parameter which has not yet been transferred onto the device�

8.1 Memory plug parameter settingA memory plug (E30398) serves for storage and transfer of parameter values of various devices� The parameter values can be directly copied from the sensor to the memory plug, or written to it by the LR DEVICE� For further details refer to the operating instructions of the memory plug�If a memory plug is connected, the following additional information is shown in the header:

No parameters are stored on the memory plug, no write protection activated� or Parameters are stored on the memory plug, they can be edited, no write protection activated�Attention! Inconsistent data may be generated!Parameters are stored on the memory plug, they cannot be edited, write protection is activated�

After reading of a memory plug which contains data, appears� By clicking on the icon, the parameters of the stored device are displayed� (→ Display of the data stored on the memory plug)

appears after clicking on � By clicking on the parameter list of the memory plug is displayed again The icon changes again to (→ 7.2)�

The memory plug only provides memory space for the parameters of one device�

UK

LR DEVICE

13

Writing to the memory plug: ► Read IO-Link parameters from a device using the LR DEVICE software or select offline setup�

► Edit parameters ► Connect the memory plug to the USB IO-Link master� ► Click on [ ] to save data on the memory plug�

The write protection is activated via the system command [Write protect]�The system command [Read Write] deactivates the write protection�

8.2 Display of the data stored on the memory plug ► Connect the memory plug to the USB IO-Link master� ► Click on [ ]�

> The parameter list of the connected memory plug is loaded into the software�

► Click on [ ]�

LR DEVICE

14

> All stored parameters are displayed and can be edited�

► Click on [ ]� > The parameter list of the connected memory plug is displayed�

UK

LR DEVICE

15

9 CockpitThe cockpit features:

– Display instruments: Measured values and switching states are displayed in the form of display instruments in the respective current condition�

– Chart: Representation of the measured values / switching states in a time diagram�

► Click on [Cockpit]� > The cockpit is displayed with current measured values and output response�

① Display instruments Simplified graphical representation of the outputs�

② Events Events are displayed with code, name and time�

③ Set the device sampling rate Setting of the transmission rate of new measured values (number of measured values detected per time unit)�

④ Export Measured values of the chart are stored in a csv file�

⑤ ChartThe measured values and switching states over a defined period of time are visualised� The legend illustrates which characteristic curve refers to which measured value�

⑥ Edit / ConfigurationEditing of the diagram labelling Definition of the time range of the X axis� Activation or deactivation of the legend�

⑦ Add / remove data sources The display of detected data sources in the chart can be activated or deactivated�

LR DEVICE

16

9.1 Symbols used for measurement locations / data sources

Type of display Description SymbolPointer instrument Display form typically used for pressure

measurements in bar / psi / MPa ���Based on measurement equipment in manometer design�

bar graph Display form for process values typically not displayed on a manometer or thermometer�

Thermometer Display form typically used for temperature measurements in °C / °F ��� � Based on measurement equipment in thermometer design�

Output status Display of digital I/O signals�Only one display mode is shown�

● Display "ON" = active / output "high"

or

● Display "OFF" = inactive / output "low"

UK

LR DEVICE

17

10 Offline setupOffline setup allows editing of a set of parameters without connecting the corresponding device� Only the IODD is required for the device to be set� For ifm units, these are stored in the LR DEVICE�

► Click on [Offline setup]� > The offline setup environment appears�

► Click on [ifm electronic gmbh] ①� > A preselection with product ID is shown in the device catalogue� ► Select [PN2] ② to get to the group of pressure sensors PN2xxx�

► Click on [PN2070] ③ � > The set of device parameters for PN2070 is displayed for editing�

LR DEVICE

18

> [All] ④ parameters are activated and can be edited�Alternatively fast access to IODD files for offline parameter setting via article no� is possible (→ 6.4)�

► Edit [SP_FH1] ⑤ ; in this case an invalid value was entered on purpose� > [ ] ⑥ - invalid - is displayed� The value must lie in the range between min

and max value� ► Correct the value [SP_FH1] ⑤ , respect the min / max limits! ► Select [ ] to save the parameters as an "�lpr" file�

> The "�lpr" file is saved in the download directory of the PC� It can be retrieved at any time�

In the offline mode reading with [ ] or writing with [ ] to a connected device is not possible� The saved file with the parameters can only be accessed in the online mode and then be written to the device�With [ ] (→ 6.4) writing to a connected and identified device in the offline mode is possible�

11 Update IODD / device catalogueThe LR DEVICE software provides an easy way to keep the IODDs / the device catalogue up to date� The symbol [ ] turns pink when there is an existing internet connection� This shows that new IODDs are available�

► Click on [ ]� > The dialogue menu "Device description files (IODD): download and install" is

opened�

► Click on [IODDs] ① which are to be installed / updated�

UK

LR DEVICE

19

► Click on [OK] ② � > A dialogue window is opened with the information that the device definitions

(IODDs) are updated� > After completion of the update, the symbol turns grey�

As an alternative, IODDs can be saved as a file on a storage medium and imported later�

► Click on [ ] ► Click on [Browsing���] ③ � ► Select the storage medium in the dialogue window and tick the file� ► Click on [Open]

> A dialogue window is opened with the information that the device definitions (IODDs) are updated�

> After completion of the update, the symbol turns grey�

LR DEVICE

20

12 Fault correctionList of frequently asked questions and their solutions (FAQ and Troubleshooting)

Question SolutionSoftware does not start ► Reboot the computerSensor is not detected� Error message "No connected device was found!" appears

► Disconnect USB connection PC / USB IO-Link master

► Reconnect after a waiting time of about 30 s

► Restart the procedure

► Enter LR DEVICE licence key� ► Check network connection� ► Check network settings�

The installation routine is not completed

A module may not have been detected correctly, or a wrong driver may have been selected�

► End the installation ► Start deinstallation ► Reboot the computer ► Restart the installation process

Poor display in the web browser� ► Test an alternative browser (→ 3.2 PC software)�

> A poor display does not have any impact on the function