3AL 74401 AAAA1
TM
Alcatel 1641 SX4/1 MultiService Metro Gateway
Release 6.31
Subracks
Operating Instructions
3AL 74401 AAAA − Edition 02 / April 2001
Alcatel Terrestrial Networks Division
3AL 74401 AAAA1
Operating InstructionsSubracks
Contents
Customer Documentation 4/1 MultiService Metro Gateway Alcatel"OptinexTM
1641 SX (4/1 OMSG) Release 6.3*1Preliminary remarks on Page 3 and followingAbbreviations on Page 9 and following
Registers
Product Safety Instructions 1
Computer Subracks 2
Matrix Subracks ESS/CSS, HESS/HCSS 3
I/O STM04 via ADM Alcatel 1651 SM see next side
Common I/O Shelf 4
SDH dedicated Input/Output Subracks 5
PDH dedicated Input/Output Subracks 6
Ordering Information 7
NOTICERead the section ’Product Safety Instructions’ (Register 1)before operating the system for the first time. It is alsorecommended to re0read this section at certain intervals inorder to refresh your knowledge about safety.
Please find the translation of these instructions in differentlanguages in the Appendix of the Hardware InstallationManual.
3AL 74401 AAAA2
Add/Drop Multiplexer System (ADM) Alcatel 1651 SM
I/O STM�4 access is performed by an Add/Drop Multiplexersystem Alcatel�1651�SM integrated in a separate 4/1 OMSGrack which has been specially modified. The ADM systemis controlled by a network management system or a localcraft terminal directly connected to the ADM equipment onopening the rack doors. The management of the ADM is in'dependent from the partsystem Control of the 4/1 OMSG.The alarms Urgent and Non'urgent, indicated by LEDs onthe ADM equipment, are forwarded to the lamps in the TopRack Unit TRU of the ADM modified rack (see Section 2.9in the Hardware Installation Manual). For a description ofthe ADM and information on how it is operated refer to theaccompanying Alcatel�1651�SM documentation TechnicalHandbook and Operator’s Handbook.
NOTICEThe alarm Attended indicated by an LED on the ADMequipment is not forwarded to the lamps in the TRU of theADM modified rack.
In general, the feature ’Attended Alarm’ is not presentlysupported by the 4/1 OMSG hardware. Therefore, theoccurrence of an attended alarm is only visible on the ADMequipment after opening the rack doors.
3AL 74401 AAAA3
Customer DocumentationAlcatel OptinexTM 1641 SX Release"6.3*1
Organization of the Documentation
The 4/1 MultiService Metro Gateway Alcatel�OptinexTM
1641888SX (4/1 OMSG) customer documentation consists ofthe following manuals (the manual on hand is printed inbold):
− Functional Description Partsystems
− Operating Instructions Subracks
− Hardware Installation Manual
− Operation Manual Craft Terminal Software
− Alcatel�1651�SM Technical Handbook and Operator’sHandbook (if equipped)
Apart from this documentation, especially created forcustomers, Alcatel SEL supplies manufacturer documentsas well. The manufacturer documents are only supplied todepartments which are responsible for maintaining andmodifying the system. These documents are not describedhere.
3AL 74401 AAAA4
Contents of the Manuals
The manual Functional Descriptions Partsystems de'scribes the way the 4/1 OMSG works. The logical subdivi'sion of the system in partsystems does not correspond to itsmechanical construction. The partsystems are:
− Control
− Clock Generation and Distribution
− Matrix
− Common I/O shelf
− Input/Output of synchronous and plesiochronous signals.
The manual Operating Instructions Subracks de'scribes their mechanical features and the use of the operat'ing elements. Not all boards contained in the subrack be'long to the partsystem corresponding to this subrack. AnOperating Instruction consists of:
− the subrack equipment
− the assignment of the connector strips
− Common I/O shelf
− the subrack cabling
− test sockets, switches, alarm indicators on the frontpanel of the boards and their function.
The Hardware Installation Manual summarizes themechanical construction details of racks, Common I/O shelfand subracks. It provides information on hardware start'upand upgrade procedures for the entire 4/1 OMSG.
The Operation Manual Craft Terminal/Craft Termi�nal for Multiple NE/Users describes the operation of the4/1 OMSG using the CT or SH'DXC, performing adminis'trative and maintenance tasks and alarm handling.
3AL 74401 AAAA5
The manual consists of
− the Operation Manual CT/SH'DXC Introductiondescribing the main features of the graphicalinterface and providing a general overview of thesystem architecture, the managed equipment and thedifferent functionalities provided by the SDHManager.
− the Operation Manual CT/SH'DXC Constructiondescribing the operations related to the managementof Maps, Submaps and symbols within the SDHManager and indicating the actions leading to thecreation, edition, deletion, storage and listing ofMaps.
− the Operation Manual CT/SH'DXC Error Messagesreporting any error that is propagated to theoperator interface, as well as an explanation andsome possible actions whenever appropriate.
− the Operation Manual CT/SH'DXC Administrationdescribing administrative and maintenance tasksprovided by the System Maintenance Features suchas creating users and installing the AU application.
− the Alarm Reference Guideproviding information of all possible alarms on theCT concerning cause, effect on service and ways toget out of the alarm situation.
− the Operation Manual Alarm Manager ALMAP ASproviding information concerning alarm surveillanceand alarm management such as displaying alarmlists, acknowledging alarms.
− the Operation Manual Security Management ALMAPSECdescribing the operation of the SEC Access ControlInformation Administration (ACA) tool. It introducesthe different access control concepts, such asfunctions, objects and combinations, FunctionalAccess Domains (FADs), and Object Access Domains(OADs), operators groups, initiators, targets, anduser profiles.
− the Operation Manual Log Management ALMAP ELMdescribing the operation of the ELM (Element LogManager) generic component, which deals with the
3AL 74401 AAAA6
management of Event Forward Discriminators(EFDs) together with the management and thebrowsing of logs.
The Alcatel 1651 SM system handbooks comprise allinformation concerning the ADM extension of the4/1�OMSG for STM'4 access. These handbooks are suppliedonly if an ADM equipment is contained in the system sup'plied.
SymbolsThe manual at hand contains the following symbols:
ATTENTIONis used to mark information provided to prevent materialdamages or operation errors.
NOTICEis used to emphasize particularly important information.
3AL 74401 AAAA7
Registered Trademarks
− HP is a registered trademark of the Hewlett'PackardCorporation
− HP OpenView is a registered trademark of theHewlett'Packard Corporation
− Sun, SunOS, SPARC, NeWSprint and Solaris areregistered Trademarks of Sun Microsystems, Inc.
− UNIX is a registered trademark of UNIX SystemLaboratories, AT&T.
− DEC VT is a registered trademark of DigitalEquipment Corp.
− Seagate is a registered trademark of SeagateTechnology, Inc.
− Motorola, VMEexec and UNIX SYSTEM V/88 areregistered trademarks of Motorola, Inc.
− All other names, products and services mentionedare trademarks of their respective holders.
3AL 74401 AAAA8
CE Conformity
The 4/1 MultiService Metro Gateway Alcatel�OptinexTM
1641�SX (4/1 OMSG) meets the EU Directives
− 73/23/EEC Low voltage
− 89/336/EEC Electro'MagneticCompatibility.
The 4/1 OMSG complies with the standards or normativedocuments
− EN60950 Safety of information FEd. 08.1992 technology equipment with A3 FEd. 01.1996and A4FEd. 03.1997
− EN55022 EMC (Electro'Magnetic FEd. 04.1987 Compatibility; Emission)
− EN50082'2 EMC (Electro'Magnetic FEd. 03.1995 Compatibility; Immunity)
− ETS300386'2 EMC (Electro'Magnetic FEd. 12.1997 Compatibility)
and can therefore carry the CE marking.
Service Information
In case of problems with the 4/1 OMSG, please contact yourCustomer Support Center for any information.
3AL 74401 AAAA9
Abbreviations
A21E1 Access board 21x2 Mbit/s
A4ES1 Access board 4xSTM'1 Electrical
ADB Adapter Board (IOS45, IOS2D)
ADM Add/Drop Multiplexer
AD.. Adapter GTI to LMC960/480FADIS Adapter Input SignalsFADOS Adapter Output Signals
AIS Alarm Indication Signal
AS Adaptation (double) Subrack
ASIC Application Specific IC
AU Administrative Unit
BER Bit Error Ratio
BIP Bit Interleaved Parity
BP Backpanel FBPF BP Format
BSB Battery Supervision Board (TRU)
C Container (SDH) for plesiochronous signalsFC'12 Container C'12 (2 Mbit/s)FC'3 Container C'3 (34 Mbit/s)FC'4 Container C'4 (140 Mbit/s)
CDB Clock Distribution BoardFCDBE CDB for LVDS signals (ESSD)FCDBF CDB for LVDS signals (HESS)FCDBC/D CDB for ECL signals (Dedicated I/O)
CDC Clock Distribution Circuit
CEPT Conférence Européenne des Administration des Postes et des Télécommunications
CFC Clock + Frame receive Circuit
3AL 74401 AAAA10
CIB Clock Interface Board
CK, Cl Clock
CKD Clock Dominator
CMI Coded Mark Inversion
CONGI Control and General Interface
CONV Converter unitFCONV3 Converter −5.1/+5.6 V, 30 AFCONV3A Converter −5.1/+5.6/+3.7 V, 30 AFCONV3B Converter −5.1/+5.6, 30 AFCONV4A Converter −3.7/+3.7/+12 V
CP Communication Processor
CPU Central Processing Unit
CRC Cyclic Redundancy Check
CRU Clock Reference Unit
CS'Byte Connection Supervision Byte in the SOH
CSIFA Control System Interface ASIC
CSSD Center Stage Double Subrack
CT Craft Terminal
CXB Center'stage Matrix BoardFCXB32 CXB 32x32 portsFCXB40 CXB 40x40 ports
D'Bit Urgent alarm message from the remote station
DCE Data Communication Equipment (modem)
DCC Data Communication Channel
DM Demapping (of the GTI signal / transmit direction)
DMA Direct Memory Access
DRAM Dynamic RAM
DSB DCC Server Board
3AL 74401 AAAA11
DTE Data Terminal Equipment
DTSCA Duplex To Simplex Converter ASIC
DU Domestic Unit
EC Equipment Controller
ECC Embedded Control Channel
ECL Emitter Coupled Logic
EEPROM Electrically Erasable Programmable ReadOnly Memory
EM Electro'MagneticFEMC Electro'Magnetic CompatibilityFEMI Electro'Magnetic Interference
EPB External Protection Board
EPS Equipment Protection Switching
EQUICO Equipment Controller
ESS End Stage SubrackFESSD End Stage Double Subrack
ETB Extension Board
ETSI European Telecommunications Standardization Institute
EXB End stage Matrix Board FEXBA EXB 16x16 STM'1 equivalents, LMC448FEXBB EXB 16x16 STM'1 equivalents, LMC480FEXB32 EXB 32x32 STM'1 equivalents, LMC960F
EXT Extraction ASICFEXT'DM EXT Demapping on IOB140FEXT'MP EXT Mapping ASIC on IOB140
3AL 74401 AAAA12
FAW Frame Alignment Word
FPE Functional Protection Earth
FPGA Free Programmable Gate Array
FRCL Frame Clock
GND Ground
GTI Generic Transfer Interface, internal interfaceI/O−Matrix, STM'1 modified
FGTIP Parallel GTI signal
FGTIS Serial GTI signal
HCMOS High'speed Complementary Metal OxideSemiconductor
HDB3 High Density Bipolar code, level 3
HDLC High'level Data Link Control, P'bus
HOA Higher'Order Assembler
HP Higher'order Path FHPA HP AdaptationFHPC HP ConnectionFFHCSS HPC Center Stage SubrackFFHESS HPC End Stage SubrackFHPOM HP Overhead MonitoringFHPT HP Termination
HPROT High speed PROTection
HSC Hitless Switching Circuit
HSUT Higher'order Supervised Unequipped Termination
IC Integrated Circuit
I2C, IIC Inter Integrated Circuit bus
IEC IPBB Extension Connector
3AL 74401 AAAA13
IO Input/Output
IOB Input/Output BoardFIOB140 IOB 140 Mbit/sFIOB155 IOB 155 Mbit/sFIOB2 IOB 2 Mbit/sFIOB2400 IOB 2488 Mbit/sFIOB34 IOB 34 Mbit/sFIOB45 IOB 45 Mbit/s
IOS Input/Output SubrackFIOS2400 IOS 2488 Mbit/s (STM'16)FIOS155 IOS 155 Mbit/sFIOS155D IOS 155 Mbit/s (Double Subrack)FIOS140 IOS 140 Mbit/sFIOS140D IOS 140 Mbit/s (Double Subrack)FIOS45 IOS 45 Mbit/sFIOS34 IOS 34 Mbit/sFIOS34D IOS 34 Mbit/s (Double Subrack)FIOS2 IOS 2 Mbit/sFIOS2D IOS 2 Mbit/s (Double Subrack)
IPB Internal Protection Board (IOS140D, IOS34D, IOS2D)
FIPBB Internal Protection Board type B (IOS2400, IOS155D, IOS45)
ISO International Organization for Standardization
ITU'T International Telecommunication Union ' sector Telecommunication
LAN Local Area Network
LED Light Emitting Diode
LAPD Link Access Protocol for D channel
LIF.. Low'order Interface adapterFLIFAG LIF Asymmetrical GTI/LVDS (EXBB/EXB32)FLIFAL LIF Asymmetrical LVDS/GTI (EXBB/EXB32)FLIFG LIF GTI/LVDS (EXBA/EXBB)FLIFL LIF LVDS/GTI (EXBA/EXBB)FLIF2G LIF GTI/LVDS (EXBB/EXB32)FLIF2L LIF LVDS/GTI (EXBB/EXB32)
LMC Large Matrix Configuration
3AL 74401 AAAA14
LOx Loss Of ...FLOC Loss Of ClockFLOF Loss Of FrameFLOM Loss Of MultiframeFLOP Loss Of PointerFLOS Loss Of Signal
LP Lower'order PathFLPA LP AdaptationFLPC LP ConnectionFLPOM LP Overhead MonitoringFLPT LP Termination
LSI Large Scale Integration circuit
LSUT Lower'order Supervised Unequipped Termination
LVDS Low Voltage Differential Signal
MAC Medium Access Control
MCB Master Clock Board
MDVC3 Mapping Demapping ASIC on IOB34
MDX140 140 Mbit/s Multiplexer/Demultiplexer
MP Mapping (to GTI Signal / receive direction)
MPB Main Power Block
MS'SPRINGMultiplex Section Shared Protection Ring
MPU Microprocessor Unit
MS Multiplexer SectionFMSA MS AdaptationFMSOH MS OverheadFMSP MS ProtectionFFMSPB MSP BoardFMST MS TerminationFMS'AIS MS Alarm Indication Signal
MTOS'UX Operating System of the SPBs
MUX2 Multiplexer Board (in AS)
MUX2/34 Multiplexer/Demultiplexer for 2, 8 and 34 Mbit/s signals
3AL 74401 AAAA15
NAU New Administrative Unit
NALMB New Alarm Board
N'Bit Non'urgent alarm message from the remote station
NCC New Communication ControllerFNCC'PE NCC Processing Element
NCO Numerically Controlled Oscillator
NGI New Generic transport Interface
NRZ Non Return to Zero
NUTS New Utility Subrack
NVRAM Non'Volatile RAM
OA Optical Amplifier
OBPS On Board Power Supply
ODL Overhead Data Link
OMSG OptinexTM MultiService Gateway4/1 OMSG MultiService Metro Gateway
Alcatel OptinexTM 1641 SX4/4 OMSG MultiService Core Gateway
and Cross Connect Alcatel OptinexTM 1664�SX
OOF Out Of Frame
OS Operation System (Network ManagementSystem)
OSI Open System Interconnection
P4ES1 Port board 4xSTM'1 Electrical
P4S1 Port board 4xSTM'1 Optical
P63E1 Port board 63x2 Mbit/s
P/S Parallel to Serial conversion
P'bus HDLC bus between SPB and UBPE
3AL 74401 AAAA16
PC Personal Computer
PCB Protection and Clock distribution Board
PCS Plesiochronous Supervision FPCS140 PCS of the 140 Mbit/s signalFPCS2 PCS of the 2 Mbit/s signalFPCS34 PCS of the 34 Mbit/s signalFPCS45 PCS of the 45 Mbit/s signalFPCS8 PCS of the 8 Mbit/s signal
PDH Plesiochronous Digital Hierarchy
PFU Power Filter Unit
PISO Parallel Input Serial Output
PLL Phase Locked Loop
PMP.. Protected Monitoring Point PMPRX Test Socket Receive Signal PMPTX Test Socket Transmission Signal
PMMF Physical Machine Management Function
POH Path Overhead
PPI Plesiochronous Physical Interface
PS Power SupplyFPSU Power Supply Unit
PSCE Physical Shelf Control Element
QDCN Connection Network Management Interface
R'bus I2C bus for RI of subracks and boards
RA Remote Alarm
RAB Rack Alarm Board
RAM Random Access Memory
RC Receive Clock
RDI Remote Defect Indication
REI Remote Error Indication
3AL 74401 AAAA17
RI Remote InventoryFRIM RI Module
RS232/485 Recommended Standard, American EIA Interface Standard
RS Regeneration SectionFRSOH RS OverheadFRST RS Termination
RTZ Return To Zero
RX Receive Side
S16 Port board STM'16
S2231 TUG22 Mapping'Demapping LSI
S4 Port board STM'4
S'bus I2C bus between SPB and CSIFA
SC System Clock (from CDB)
SCI Switch Control Interface
SCGL Signal Cable Grounding Labyrinth
SDH Synchronous Digital Hierarchy
SEC Synchronous Equipment Clock
SIO Serial Input/Output
SLM Signal Label Mismatch
SMC Switching Matrix Circuit
SMX Shelf Matrix Extender
SNC'P SubNetwork Connection Protection
SOH Section Overhead
SPB Satellite Processor BoardFSPBB SPB type B
SPC Serial'Parallel Converter
SPRING Shared Protection Ring
SPI Synchronous Physical Interface
3AL 74401 AAAA18
SSF Server Signal Failure
SSM Synchronization Status Message
SSU Synchronization Supply Unit
STM Synchronous Transport ModuleFSTM'1 STM Signal 155 Mbit/sFSTM'1E Board STM'1 electricalFSTM'1S Board STM'1 optical (short haul)FSTM'1L Board STM'1 optical (long haul)FSTM'4 STM'4 Signal 622 Mbit/sFSTM'16 STM'16 Signal 2488 Mbit/s
TC Transmit Clock
TIM Trace Identifier Mismatch
TRU Top Rack Unit
TS Trail Signal FTSD TS DegradeFTSF TS Failure
TTF Transport Termination Function
TTL Transistor'Transistor'Logic
TUG Tributary Unit GroupFTUG22 TUG level 2 (8 Mbit/s) CEPT
TX Transmit Side
UB User BoardFUBPE UB Processing Element
VC Virtual Container FVC'12 Virtual Container for C'12 (2 Mbit/s)FVC'3 Virtual Container for C'3 (34 Mbit/s)FVC'4 Virtual Container for C'4 (140 Mbit/s)
VMEbus VME'bus system
3AL 74401 AAAA19
WAN Wide Area Network
WDM Wavelength Division Multiplexer
X.25 Interface according to ITU'T X.25
3AL 74401 AAAA20