+ All Categories
Home > Documents > Optically Amplified Multigigabit Links in CESNET2 network

Optically Amplified Multigigabit Links in CESNET2 network

Date post: 21-Jan-2016
Category:
Upload: leanne
View: 32 times
Download: 0 times
Share this document with a friend
Description:
Optically Amplified Multigigabit Links in CESNET2 network. Jan Radil Leoš Boháč Miroslav Karásek. www.cesnet.cz. Optically Amplified Multigigabit Links in CESNET2 network Outline. Motivation for extending the span length Numerical simulations @10 G Practical results (single channel, DWDM) - PowerPoint PPT Presentation
26
May 19-22, 2003 TERENA Networking Conference Zagreb, Croatia 1 Optically Amplified Multigigabit Links in CESNET2 network Jan Radil Leoš Boháč Miroslav Karásek www.cesnet. cz
Transcript
Page 1: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 1

Optically Amplified Multigigabit Links in CESNET2 network

Jan RadilLeoš Boháč

Miroslav Karásek

www.cesnet.cz

Page 2: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 2

Optically Amplified Multigigabit Links in CESNET2 network

OutlineMotivation for extending the span lengthNumerical simulations @10 GPractical results (single channel, DWDM) Conclusions

Page 3: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 3

Experimental and theoretical results on extending the span length Repeaters for 1 GE, 10 GE or 10 G POS ?Repeater-less or nothing-in-line transmissions at 1 Gbit/s, 2.5 Gbit/s and 10 Gbit/s over standard G.652 SMFFibre on the top of high-voltage poles, coast-island links, power supplies, maintenance ? Using optical amplifiers (EDFA, Raman)

Optically Amplified Multigigabit Links in CESNET2 network

Motivations

Page 4: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 4

To estimate the maximum span length @10Gb/s for single channel transmissionsCompensation of chromatic dispersion - DCFPost- and pre-compensation schemes Effect of self-phase modulation (SPM)For 1 G and 2.5 G - these effects negligibleTo keep the BER better than 10-12 (or Q > 7)

Optically Amplified Multigigabit Links in CESNET2 network

Numerical simulations

Page 5: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 5

Different wavelengths propagate at different speedsIncreases as the square of the bit rate

Optically Amplified Multigigabit Links in CESNET2 network

Chromatic dispersion

100 km of SMF G.652, without compensation

100 km of SMF G.652, with compensation

Page 6: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 6

Optically Amplified Multigigabit Links in CESNET2 network

Self-phase modulation

Signal modulates its own phase (Kerr effect) The effect increases with spectral density and the bit rate

Page 7: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 7

Optically Amplified Multigigabit Links in CESNET2 network

Post and pre-compensation schemes, SMF 0,22 dB/km, DCF 0,55 dB/km

Post-compensation scheme

Pre-compensation scheme

High quality parameters for fibres and lasers Possible problems with „real“ componentsBetter - post-compensation

Page 8: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 8

Optically Amplified Multigigabit Links in CESNET2 network

Post-compensation, optimalization of the degree of compensation

0.6 0.7 0.8 0.9 1.04

5

6

7

8

9

LSMF

= 270 km, PDCF

= 0 dBm

Q,

dB

DCR

PSMF

= 16 dBm

17dBm 18dBm 19dBm 20dBm 21dBm

DCR = |LDCF*DDCF|/(LSMF*DSMF), LSMF = 270 km, PDCF = 0 dBm

5.8

5.83.8

3.81.7

7.9

0.6 0.7 0.8 0.9 1.016

17

18

19

20

21

SM

F in

put

pow

er,

dBm

DCR

LSMF

= 270 km, PDCF

= 0 dBm

Q

Page 9: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 9

Optically Amplified Multigigabit Links in CESNET2 network

Post-compensation, optimalization of input powers PSMF and PDCF

-15 -10 -5 0 5 10

-25

-20

-15

-10

-5

log

BE

R

DCF input power, dBm

PSMF

=16 dBm

17 dBm 18 dBm 19 dBm 20 dBm 21 dBm

LSMF

= 270 km, LDCF

= 45 km

DCR = 0.83, LSMF= 270 km, LDCF= 45 km

-6.3

-13

-6.3

-20

16 17 18 19 20 21

-15

-10

-5

0

5

10

DC

F in

put

pow

er,

dBm

SMF input power, dBm

LSMF

= 270 km, LDCF

= 45 km

BER

Page 10: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 10

Optically Amplified Multigigabit Links in CESNET2 network

Post-compensation, 270 km SMF +45 km DCF, PSMF=19 dBm, PDCF=0 dBm

17 18 190

1

2

3

4

after SMF

pow

er, W

time, ns

17 18 190

5

10

15

20

25

after DCF

optic

al p

ower

, W

time, ns

17 18 190

5

10

15

20

25

after OBPF

optic

al p

ower

, W

time, ns17 18 19

0.0

0.2

0.4

0.6

0.8

1.0

after ELP

PD

vol

tage

, a.

u.

time, ns

Page 11: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 11

BER as a function of input power: post-compensation scheme

Eye diagram post-compensation

270 km SMF + 45 km DCF

PSMF= 19 dBm, PDCF = 0dBm

Optically Amplified Multigigabit Links in CESNET2 network

Page 12: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 12

1 GE, 2.5 G POS and 10 GE with NILThree different configurations Booster, + preamp, + RamanFiber field test-beds 25, 50, 100, 200 kmTwo GE backbone lines (189 km and 170 km) are currently in use in CESNET2 network [1]

Optically Amplified Multigigabit Links in CESNET2 network

Practical results

Page 13: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 13

Cisco Catalyst 6503 with 1 port 10 GE 1550 nm linecards, GSR 12008 for POSKeopsys High power booster 30 dBm, low noise preamplifier 13 dBmRaman pump 24 dBm, provided by IREESantec & JDS optical filtersOFS DCF

Optically Amplified Multigigabit Links in CESNET2 network

Practical results – equipment used

Page 14: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 14

Scenario 1 – booster only

Scenario 2 – booster and preamplifier

Optically Amplified Multigigabit Links in CESNET2 network

Practical results – tested scenarios

Page 15: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 15

Scenario 3 – booster, preamplifier and Raman pump

Scenario 1 – booster only for POS

Optically Amplified Multigigabit Links in CESNET2 network

Practical results – tested scenarios

Page 16: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 16

Not DWDM lasers (chirp, linewidth, modulators)Fibre field test-beds – cables with patchcordsA lot of patchcords between lab and ODFRecalculating of length to more realistic figures…with attenuation 0,27 dB/km

Optically Amplified Multigigabit Links in CESNET2 network

Practical results – problems pt.1

Page 17: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 17

Optically Amplified Multigigabit Links in CESNET2 network

Practical results – 1 GE and 2.5 G POSSpee

dLoopsLength

Scenario

DCF

OF EstimatedLength

Results

GE 200 km

BoosterPreamp

No No 220 km OK!

GE 200 km + 25 km

BoosterPreamp

No Yes

270 km Short packets

2.5 G

200 km

BoosterPreamp

No No 220 km OK!

2.5 G

200 km + 25 km

BoosterPreamp

No Yes

270 km Failed

Page 18: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 18

Optically Amplified Multigigabit Links in CESNET2 network

Practical results – 10 GELoopsLength

Scenario

DCF OF EstimatedLength

Results

100 km Booster No No 125 km OK!

100 km + 50 km

BoosterPreamp

Yes Yes 180 km OK!

200 km BoosterPreampRaman

Yes Yes 220 km Failed

Page 19: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 19

BER measurement ?No BERT equipment – we rely on PINGPOS line cards with BIP countersFor 1 GE even better situationDifficult for 10 GE, we still believe in our simulations and PING testing Billions of long packets with 0% drop-outs

Optically Amplified Multigigabit Links in CESNET2 network

Practical results – problems pt.2

Page 20: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 20

Verify the possibility to use single channel EDFA with DWDM system (up to 8 lambdas)Three DWDM platforms: Cisco 15540, Cisco 15200 (together with Cisco EDFA 15501) and Pandatel Fomux 3000 Keopsys optical amplifiers

Optically Amplified Multigigabit Links in CESNET2 network

DWDM systems testing

Page 21: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 21

Spectral diagram for 30 dBm input power, after EDFA.

Spectral diagram for 30 dBm input power, before receiver.

Optically Amplified Multigigabit Links in CESNET2 network

DWDM systems testing

Page 22: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 22

Strong effects of SPM, CPM and FWMOSC mostly affectedSingle-channel EDFAs are OK for 5 channelsFor 16/32 channels you need really powerful booster (17 dBm for 1 channel corresponds to 2 dBm for 32 channels)

Optically Amplified Multigigabit Links in CESNET2 network

DWDM systems testing

Page 23: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 23

We presented NIL solutions for multigigabit links „Better“ fibersBetter equipment (low noise amps, DWDM lasers)More precise compensation: DCF and/or FBGBER measurement, eye-mask testing

Optically Amplified Multigigabit Links in CESNET2 network

Conclusions

Page 24: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 24

Thanks to Lada Altmanová, Stanislav Šíma and Martin Míchal from CESNET

Optically Amplified Multigigabit Links in CESNET2 network

Acknowledgements

Page 25: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 25

[1] Šíma S., Altmanová L., „Development of the CESNET2 Optical Network“, TNC 2002

[2] Agrawal G.P., „Fiber-optic Communication systems“, J.Wiley, 2002

[3] Agrawal G.P., „Nonlinear Fiber Optics“, Academic Press, 2001

[4] Kartalopoulos S.V., „DWDM Networks, Devices and Technology“, J.Wiley, 2003

Optically Amplified Multigigabit Links in CESNET2 network

References

Page 26: Optically Amplified Multigigabit Links in CESNET2 network

May 19-22, 2003 TERENA Networking

Conference Zagreb, Croatia 26

Thank you for your attention!

Optically Amplified Multigigabit Links in CESNET2 network


Recommended