Optimisation of Steam and Condensate Systems of Paper Machines
Energy Efficiency in IPPC Installations
Energy Efficiency in IPPC Installations G. Bachmann 2
- The Environmental Managers -
Dr. Gerald BachmannProject Manager Energy and EnvironmentALLPLAN GmbHSchwindgasse 10, A-1040 WienTelefon +43-1-505 37 07-43Telefax +43-1-505 37 07-27E-mail: [email protected]
Energy Efficiency in IPPC Installations G. Bachmann 3
- The Environmental Managers -
Agenda
• Steam and Condensate Systems of Paper Machines• Optimisation Possibilities• Simulation• Experiments• Conclusion
Energy Efficiency in IPPC Installations G. Bachmann 4
- The Environmental Managers -
Steam and Condensate Systems of Paper Machines
Separator 1
Auxiliary Condenser
Separator 2 Separator 3
Heating Section 1
Hood Air Heating section
Heating Section 2 Heating Section 3
Separator 4
Energy Efficiency in IPPC Installations G. Bachmann 5
- The Environmental Managers -
Optimisation Possibilities
There are two main possibilities to identify better operating conditions
• Simulations• Experiments
1.Creating the simulation model
2.Feeding the model with data
3.Correct the model
4.Simulation
Energy Efficiency in IPPC Installations G. Bachmann 6
- The Environmental Managers -
Creating the simulation model
Simulation I
Energy Efficiency in IPPC Installations G. Bachmann 7
- The Environmental Managers -
Simulation II
Feeding the model with data
Correct the model
paper output [t/h]
coolant temperature [°C]
coolant flow [l/s]
water temperature [°C]
steam pressure HS 3 [bar]
steamconsumption[t/h]
steam pressureHS 5 [bar]
steam pressureHS 4 [bar]
steam pressureHS 3 [bar]
steam pressureHS 6 [bar]
steam pressureHS 2 [bar]
steam pressureHS 1 [bar]
Energy Efficiency in IPPC Installations G. Bachmann 8
- The Environmental Managers -
Simulation III
Correct simulation model
Energy Efficiency in IPPC Installations G. Bachmann 9
- The Environmental Managers -
Simulation IV
Energy Efficiency in IPPC Installations G. Bachmann 10
- The Environmental Managers -
Simulation V
• by partly separating the condensate the cooling water flow is reduced from 24t/h to 2t/h
• is not heating the cooling water anymore• the energy can be used at the level of 133°C• the power saving is about 3MW
Energy Efficiency in IPPC Installations G. Bachmann 11
- The Environmental Managers -
Experiments
• the experiments must not influence the production or the quality of the product
• during the experiments all parameters are observed at the process control system
Energy Efficiency in IPPC Installations G. Bachmann 12
- The Environmental Managers -
Conclusion
The results of the Simulation were confirmed by the experiments on the paper machine
power saving: 3MW
energy saving: 24GWh/a
cost saving: 350.000€/a
Energy Efficiency in IPPC Installations G. Bachmann 13
- The Environmental Managers -
Conclusion
Allplan carried out energy efficiency programs called : in
• Austria • Hungary• Netherlands • Czech Republic• Germany • Finland• Switzerland • Romania• Slovenia • …....• ….and find savings each time
Energy Efficiency in IPPC Installations G. Bachmann 14
- The Environmental Managers -
Energy Efficiency in IPPC Installations G. Bachmann 15
- The Environmental Managers -
Dr. Gerald BachmannALLPLAN GmbH
Schwindgasse 10, A-1040 WienTel: 01/ 505 37 07/ 43Fax: 01/ 505 37 07/ 27
[email protected]://www.allplan.at
Thanks for your attention