+ All Categories
Home > Documents > Option Switches

Option Switches

Date post: 06-Mar-2016
Category:
Upload: ivan
View: 30 times
Download: 0 times
Share this document with a friend
Description:
isogen tutorial

of 357

Transcript
  • ISOGEN Option Switches Reference Guide

    Version 2010 R1

    November 2010

    DISO-PE-200013A

  • Copyright

    Copyright 1991-2010 Alias Limited. All rights reserved.

    Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available without proper authorization from Alias Limited.

    U.S. Government Restricted Rights Legend

    Use, duplication, or disclosure by the government is subject to restrictions as set forth below. For civilian agencies: This was developed at private expense and is "restricted computer software" submitted with restricted rights in accordance with subparagraphs (a) through (d) of the Commercial Computer Software - Restricted Rights clause at 52.227-19 of the Federal Acquisition Regulations ("FAR") and its successors, and is unpublished and all rights are reserved under the copyright laws of the United States. For units of the Department of Defense ("DoD"): This is "commercial computer software" as defined at DFARS 252.227-7014 and the rights of the Government are as specified at DFARS 227.7202-3.

    Unpublished - rights reserved under the copyright laws of the United States. Alias Limited 1 Stuart Road, Manor Park Runcorn, Cheshire WA7 1TS United Kingdom Telephone: +44 (0) 1928 579311 Fax: +44 (0) 1928 579389 Email: [email protected]

    Terms of Use

    It is the policy of Alias Limited to enforce any and all rights relating to protection of this information. The information contained in this manual is proprietary in nature and may not be reproduced, copied or divulged in whole or in part without the prior written consent of Alias Limited. This manual has been provided pursuant to the terms of a contract or confidentiality agreement. Unauthorized distribution or disclosure of its contents is a violation of that contract or agreement and persons doing so may be liable for penalties as provided by law.

    Warranties and Liabilities

    All warranties given by Alias Limited about equipment or software are set forth in the EULA provided with the software or applicable license for the software product signed by Alias Limited, and nothing stated in, or implied by, this document or its contents shall be considered or deemed a modification or amendment of such warranties. Alias Limited believes the information in this publication is accurate as of its publication date.

    The information and the software discussed in this document are subject to change without notice and are subject to applicable technical product descriptions. Alias Limited is not responsible for any error that may appear in this document.

    The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms of this license. No responsibility is assumed by Alias Limited for the use or reliability of software on equipment that is not supplied by Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT.

    Alias Limited is not responsible for the accuracy of delivered data including, but not limited to, catalog, reference and symbol data. Users should verify for themselves that the data is accurate and suitable for their project work.

    Trademarks

    ISOGEN and SPOOLGEN are registered trademarks of Alias Limited. All other brands and product names are trademarks of their respective owners.

  • ISOGEN Option Switches Reference Guide 5

    Contents Preface .......................................................................................................................................................... 9

    Option Switches ........................................................................................................................................ 11

    Option Switch 1: Plotfile Length ............................................................................................................ 12 Option Switch 2: Cut Piece Numbering/List Type ................................................................................. 13 Option Switch 3: Drawing Trim Marks .................................................................................................. 16 Option Switch 4: Drawing Text Size...................................................................................................... 17 Option Switch 5: Coordinates (Connection/Connectivity) ..................................................................... 19 Option Switch 6: Date Output ............................................................................................................... 20 Option Switch 7: Pipeline Splitting (User Control) ................................................................................ 21 Option Switch 8: Dimension Line Standout .......................................................................................... 22 Option Switch 9: Dimension Form ........................................................................................................ 24 Option Switch 10: Drawing Margin (Left) .............................................................................................. 27 Option Switch 11: Drawing Margin (Right) ............................................................................................ 28 Option Switch 12: Drawing Margin (Top) .............................................................................................. 29 Option Switch 13: Drawing Margin (Bottom) ......................................................................................... 30 Option Switch 14: Drawing Size (Standard Postscript Plotter Size) ..................................................... 31 Option Switch 15: Drawing Size (Height) .............................................................................................. 33 Option Switch 16: Drawing Size (Width) ............................................................................................... 34 Option Switch 17: Flow Arrows/Gaskets (Components) ....................................................................... 35 Option Switch 18: Drawing Frame (Program Standard) ....................................................................... 36 Option Switch 19: Sloping Pipeline (Indication Method) ....................................................................... 37 Option Switch 20: Sloping Pipeline (Indication Limit) ........................................................................... 39 Option Switch 21: Isometric Type ......................................................................................................... 40 Option Switch 22: Cut Piece Add-On Allowances ................................................................................ 42 Option Switch 23: Material List (Controls/File Type)............................................................................. 43 Option Switch 24: Material List (Pipeline/Drawing/Pipe Length Units) ................................................. 45 Option Switch 25: Material List Position/Title Block Position ................................................................ 47 Option Switch 26: Material List (Descriptions) ...................................................................................... 48 Option Switch 27: Material List (Text Size) ........................................................................................... 49 Option Switch 28: Material List (Item Code Length) ............................................................................. 50 Option Switch 29: Material List (Line Spacing) ..................................................................................... 51 Option Switch 30: Material List (Continuation Method)......................................................................... 52 Option Switch 31: Drawing Output (File/Screen) .................................................................................. 54 Option Switch 32: Drawing Output (Scaling) ........................................................................................ 56 Option Switch 33: Revision/Detailed Marker ........................................................................................ 57 Option Switch 34: Drawing Output (Picture Scale) ............................................................................... 58 Option Switch 35: Drawing (Reserved Areas) ...................................................................................... 59 Option Switch 36: Drawing Output (Stacking Value) ............................................................................ 60 Option Switch 37: Drawing Output (Stacking Orientation) .................................................................... 61 Option Switch 38: Pipeline Splitting (Automatic) ................................................................................... 62 Option Switch 39: Spool Piece Identifiers ............................................................................................. 64 Option Switch 40: Pipe Supports .......................................................................................................... 67 Option Switch 41: Bore/Dimension/Weight Control .............................................................................. 69 Option Switch 42: Drawing Viewpoint ................................................................................................... 72 Option Switch 43: Pipe Wastage Factor (Area 1) ................................................................................. 74 Option Switch 44: Pipe Wastage Factor (Area 2) ................................................................................. 75 Option Switch 45: Pipe Wastage Factor (Area 3) ................................................................................. 76

  • Contents

    6 ISOGEN Option Switches Reference Guide

    Option Switch 46: Pipe Wastage Factor (Area 4) ................................................................................. 77 Option Switch 47: Pipe Wastage Factor (Area 5) ................................................................................. 78 Option Switch 48: Pipe Wastage Factor (Area 6) ................................................................................. 79 Option Switch 49: Pipe Wastage Factor (Area 7) ................................................................................. 80 Option Switch 50: Pipe Wastage Factor (Area 8) ................................................................................. 81 Option Switch 51: Pipe Wastage Factor (Area 9) ................................................................................. 82 Option Switch 52: Equipment Trim Drawings ....................................................................................... 83 Option Switch 53: Weld Numbering ...................................................................................................... 85 Option Switch 54: Weld Plotting............................................................................................................ 88 Option Switch 55: Program Messages (Run Information) .................................................................... 91 Option Switch 56: Program Messages (ISODAT) ................................................................................. 93 Option Switch 57: Program Messages (ISOPLOT) .............................................................................. 94 Option Switch 58: Clear Screen ............................................................................................................ 95 Option Switch 59: Instrument Identification .......................................................................................... 96 Option Switch 60: Component Tagging ................................................................................................ 97 Option Switch 61: Insulation Indication ................................................................................................. 98 Option Switch 62: Tracing Indication .................................................................................................... 99 Option Switch 63: Printed Output (Page Length)................................................................................ 100 Option Switch 64: Pipe Support Identification ..................................................................................... 101 Option Switch 65: Bolting Units ........................................................................................................... 103 Option Switch 66: Coordinates (Supplementary) ................................................................................ 104 Option Switch 67: Sloping Pipeline (3D Skew Depiction) ................................................................... 107 Option Switch 68: Sloping Pipeline (Vertical Branches) ..................................................................... 109 Option Switch 69: Terminal Type Identification .................................................................................. 110 Option Switch 70: Skew Indication (Branches) ................................................................................... 112 Option Switch 71: Plotfile Format........................................................................................................ 113 Option Switch 72: Leading Zeros ........................................................................................................ 115 Option Switch 73: Material Part Number Enclosure Style .................................................................. 116 Option Switch 74: Material List Accumulation Control ........................................................................ 118 Option Switch 75: Weld Number (Enclosure Weld Number/Weld Number - Prefix) .......................... 121 Option Switch 76: Material Part Number Enclosure Shape ................................................................ 124 Option Switch 77: Weld Number Allocation at Slip-On Flanges and RPads ...................................... 126 Option Switch 78: Support Weld Number Prefix and Enclosures ....................................................... 128 Option Switch 79: Site Assembly Identification ................................................................................... 131 Option Switch 80: Dimensions (To Valve Centers) ............................................................................. 134 Option Switch 81: Dimensions (Branches) ......................................................................................... 136 Option Switch 82: Center of Gravity/Weight Output ........................................................................... 138 Option Switch 83: Site Welds Associated with Spools ....................................................................... 140 Option Switch 84: Curved Pipe ........................................................................................................... 141 Option Switch 85: Spare Switch .......................................................................................................... 142 Option Switch 86: Spare Switch .......................................................................................................... 143 Option Switch 87: Spare Switch .......................................................................................................... 144 Option Switch 88: Spare Switch .......................................................................................................... 145 Option Switch 89: Spare Switch .......................................................................................................... 146 Option Switch 90: Material Control (COMDACE File Contents) ......................................................... 147 Option Switch 91: Material Control (COMDACE File Controls) .......................................................... 148 Option Switch 92: DXF File Units ........................................................................................................ 149 Option Switch 93: Spare Switch .......................................................................................................... 150 Option Switch 94: Spare Switch .......................................................................................................... 151 Option Switch 95: Component Leg Length ......................................................................................... 152 Option Switch 96: Spare Switch .......................................................................................................... 154 Option Switch 97: Skew Depiction (Individual and Overall) ................................................................ 155 Option Switch 98: Spare Switch .......................................................................................................... 156 Option Switch 99: Skew Depiction (Style) .......................................................................................... 157

  • Contents

    ISOGEN Option Switches Reference Guide 7

    Option Switch 100: Skew Depiction (Dimension Line Standout) ........................................................ 159 Option Switch 101: Skew Depiction (Triangle Hatching) .................................................................... 160 Option Switch 102: Skew Depiction (Hatching Clearance) ................................................................. 161 Option Switch 103: Spare ................................................................................................................... 162 Option Switch 104: Spare Switch ........................................................................................................ 163 Option Switch 105: Spare Switch ........................................................................................................ 164 Option Switch 106: Spare Switch ........................................................................................................ 165 Option Switch 107: Spare Switch ........................................................................................................ 166 Option Switch 108: Pipeline Splitting (in Pipe) .................................................................................... 167 Option Switch 109: Repeatability Content .......................................................................................... 168 Option Switch 110: Ghost Gaps .......................................................................................................... 170 Option Switch 111: Nozzles (Dotted) .................................................................................................. 171 Option Switch 112: Flow Arrows (Pipeline) ......................................................................................... 172 Option Switch 113: Material Control (Pipeline Identification) .............................................................. 173 Option Switch 114: Specification Break Indication ............................................................................. 174 Option Switch 115: Tolerance (Angle Offset) ..................................................................................... 175 Option Switch 116: Tolerance (Dimension Offset) .............................................................................. 176 Option Switch 117: Dimension Round Off .......................................................................................... 177 Option Switch 118: Dimensions (Overall) ........................................................................................... 178 Option Switch 119: Dimensions/Elevations (Vertical) ......................................................................... 179 Option Switch 120: Tapping (Branch Scale) ....................................................................................... 181 Option Switch 121: Tapping (Branch Dimensions) ............................................................................. 183 Option Switch 122: Tapping (Branch Coordinates) ............................................................................ 185 Option Switch 123: Instrument ID Enclosure ...................................................................................... 186 Option Switch 124: Flange Rotation Angles ....................................................................................... 188 Option Switch 125: Reserved ............................................................................................................. 189 Option Switch 126: Reserved ............................................................................................................. 190 Option Switch 127: ISOGEN Version/Run Data ................................................................................. 191 Option Switch 128: Spare Switch ........................................................................................................ 192 Option Switch 129: Spare Switch ........................................................................................................ 193 Option Switch 130: Development Testing ........................................................................................... 194 Option Switch 131: Development Testing ........................................................................................... 195 Option Switch 132: Development Testing ........................................................................................... 196 Option Switch 133: Development Testing ........................................................................................... 197 Option Switch 134: Development Testing ........................................................................................... 198 Option Switch 135: Development Testing ........................................................................................... 199 Option Switch 136: Development Testing ........................................................................................... 200 Option Switch 137: Development Testing ........................................................................................... 201 Option Switch 138: Plotfile (DGN Link and Plotfile - ASCII Text) ....................................................... 202 Option Switch 139: Development Testing ........................................................................................... 203 Option Switch 140: Development Testing ........................................................................................... 204

    Index ......................................................................................................................................................... 353

  • Contents

    8 ISOGEN Option Switches Reference Guide

  • ISOGEN Option Switches Reference Guide 9

    This document comprehensively covers all current ISOGEN option switches that can be used to define isometric drawing output

    Alias Limited gives you permission to print as many copies of this document as you need for non-commercial use at your company. You cannot reprint this document for resale or redistribution outside your company.

    Preface

  • Preface

    10 ISOGEN Option Switches Reference Guide

  • ISOGEN Option Switches Reference Guide 11

    S E C T I O N 1

    ISOGEN contains a large number of variable features, such as isometric type and drawing size, dimensional units, line weight, BOM position on the isometric drawing, and so forth. These and other features are controlled by user-defined option switch settings. A total of 140 option switches are available, many of which have several positions or settings.

    Option switches give you a high level of configuration that allows you to tailor both drawings and material lists to your exact needs, including control of:

    Isometric type Fabrication and construction; fabrication only; construction only; individual spool isometrics; multi-pipeline system isometrics

    Graphic output options DXF, DWG

    Drawing size Metric A series, American ANSI sizes, or special sizes

    Viewpoint orientation Indicated by a north arrow

    Dimensions Standard string, overall, pipe supports, and to valve centers

    Drawing frame User-designed or standard

    Text Large, medium, and small

    For many option switches, a switch detail sheet is available in the Appendix of this document. The switch detail sheet provides additional information regarding how a specific option switch setting impacts isometric drawing output. If a detail sheet is available, it is listed under Option Switch Detail Sheet.at the end of the option switch topic:

    Option Switches

  • Option Switches

    12 ISOGEN Option Switches Reference Guide

    Option Switch 1: Plotfile Length Controls the physical length of the plotfile that is generated by ISOGEN. This switch is necessary only when you use the Multiple Isometrics In Each Plotfile option (OS 31= 0), and the required plotfile length is different from the default value of 3275 millimeters (mm).

    Switch Settings

    The following settings are available for Option Switch 1:

    SWITCH POSITIONS 1, 2, 3 and 4

    0 Value

    Set the plotfile length to 3275mm. This is the default setting. Set the required plotfile length in whole millimeters. The maximum length is limited to 3350mm.,

    SWITCH POSITION 5 - Used Internally by ISOGEN

    0 1

    Generate a single byte format data file. Generate a multiple byte format data file.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Plotfile Length (OS 1) (on page 207)

  • Option Switches

    ISOGEN Option Switches Reference Guide 13

    Option Switch 2: Cut Piece Numbering/List Type Controls the generation of the cut piece list and corresponding cut piece identifiers (numbers or letters) at appropriate positions along the plotted pipeline. An option to have cut piece identifiers (numbers or letters) starting at 1 or A on each isometric drawing as opposed to each pipeline is also controlled with this option switch.

    Cut piece numbers can be output on the isometric drawing in a variety of alternative enclosure types which are controlled by switch positions 7 and 8.

    There are two types of cut piece lists: the old style, which has limited information, and the new style, which has full information.

    Finally, when using imperial units you have an option to list the cut lengths on the new style cut piece list in a decimal inches format. This option is in addition to the regular value in the LENGTH column.

    Switch Settings

    The following settings are available for Option Switch 2:

    SWITCH POSITION 1 - Cut Piece Numbering and Cut Piece List On / Off Control

    0 1 2

    Suppress the generation of the cut piece list and cut piece identification numbers/letters. This is the default setting. Generate the cut piece list and cut piece identifiers. Generate cut piece identifiers that start at 1 or A on each isometric drawing.

    SWITCH POSITION 2 - Cut Piece List Style

    0 1

    Use the old style cut piece list and cut piece identifiers. Use the new style cut piece list.

    SWITCH POSITION 3 - Alphabetic Cut Piece Identifiers

    0 1

    Generate numeric cut piece identifiers. This is the default setting. Generate alphabetic cut piece identifiers.

    SWITCH POSITION 4 - Supplementary Output of Cut Length in Decimal Inches

    0 1

    Output standard cut lengths only. This is the default setting. Output supplementary cut lengths in decimal inches format in the REMARKS column of the new style cut piece list. This option only applies when you are using imperial units.

    SWITCH POSITION 5 - Calculation of Branch Cut Length to Center Profile

    0 1 2

    Calculate to the actual branch connection point. This is the default setting. Calculate to the center of the main pipeline in all situations. Use the coordinate position.

    (continued on the following page)

  • Option Switches

    14 ISOGEN Option Switches Reference Guide

    (continued from the previous page)

    Option Switch 2: Cut Piece Numbering / List Type

    SWITCH POSITION 6 - Pipe Bending File

    0 1

    Output pipe fabrication information, including details of each cut piece, listing the length, diameter, end preparation, material part number, and other related details to assist manufacturing. In addition, bending information that provides distances to/between bends, angle and radius details is also output. Output pipe fabrication information as described for the 0 setting. Also includes details to enable profiling the shaped ends or pipe and the cutting of holes for tees, olets, crosses, and so on.

    SWITCH POSITION 7 - Cut Piece Enclosure Types

    0 1 2 3 4 5 6 7 8

    Output pointed brackets. Output a diamond-ended enclosure. Output a round-ended enclosure. Output a triangular-ended enclosure. Output a diamond enclosure. Output a square-ended enclosure. Output a circular enclosure. Output an elliptical enclosure. Output a hexagonal-shaped enclosure.

    SWITCH POSITION 8- Single / Double Line Enclosure

    0 1

    Output a standard single-line enclosure. Output a double-line enclosure (circular and elliptical enclosures only).

    SWITCH POSITION 9- Additional Material to be Included on the Cut Pipe List / Report

    0 1 2 3

    Suppress additional material entries to the cut list. Add entries to the cut piece list for additional material (PIPE). Add entries to the cut piece list for additional material (MISC). Add entries to the cut piece list for additional material (PIPE and MISC).

    (continued on the following page)

  • Option Switches

    ISOGEN Option Switches Reference Guide 15

    (continued from the previous page)

    Option Switch 2: Cut Piece Numbering / List Type

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev. No. 48 - Isometric Repeatability 5.9.3 JUN 1990

    Dev. No. 56 - User-Defined BOM 7.0.0 OCT 1993

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Cut Piece Numbering/List Type (OS 2) (on page 209)

  • Option Switches

    16 ISOGEN Option Switches Reference Guide

    Option Switch 3: Drawing Trim Marks Controls the generation of trim marks for the plotted isometric drawing. Trim marks indicate the extremities of the nominated drawing size, as defined by either Option Switch 14 or Option Switches 15 and 16, and are used as a guide when trimming the plots produced on a continuous type of plotter.

    Switch Settings

    The following settings are available for Option Switch 3:

    0 1

    Suppress the generation of trim marks. This is the default setting. Generate plotted trim marks to indicate the extremities of each plotted isometric drawing.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0 APR 2003

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Drawing Trim Marks (OS 3) (on page 210)

  • Option Switches

    ISOGEN Option Switches Reference Guide 17

    Option Switch 4: Drawing Text Size Controls the physical size of the characters that are used in the output of dimensions, coordinates, and message text in the picture section of the isometric drawing.

    This option switch also controls text attributes, which allows height, width, thickness, and font to be user-defined.

    Title block text, which is always output using large characters (2.8mm), and material list text, which is controlled by either Option Switch 27 or the Material List Definition file, are not affected by the setting of this switch.

    Text height can be set in 0.1mm increments in a range between 1.0mm and 9.9mm.

    Text width can be set on 10th mm to allow the height/width ratio to be varied.

    Text thickness can be set.

    Text font can be varied; this is achieved by selecting a font from the font information file (Fontstd.fif).

    Switch Settings

    The following settings are available for Option Switch 4:

    SWITCH POSITIONS 1 and 2 - Character Height

    0 1 2 3 4 5 Value

    Output characters that are 2.4mm high. This is the default setting. Output characters that are 2.1mm high. Output characters that are 2.8mm high. Output characters that are 3.5mm high. Output characters that are 4.2mm high. Output characters that are 4.9mm high. Set the output character height in 1/10mm. Type a value in range 10-99.

    SWITCH POSITION 3 and 4 - Character Width

    This switch position is not currently available.

    Value Set the output character width in millimeters. Type a value in the range of 10 to 99.

    SWITCH POSITION 5 - Character Thickness (Weight)

    This switch position is not currently available.

    Value Set the output character thickness in millimeters. Type a value in the range of 1 to 9.

    SWITCH POSITION 6 (Spare)

    SWITCH POSITION 7, 8, and 9

    Value Set the number that corresponds to the entry in the appropriate Font Information file. Type 0, or leave blank to use the default font.

    (continued on the following page)

  • Option Switches

    18 ISOGEN Option Switches Reference Guide

    (continued from the previous page)

    Option Switch 4: Drawing Text Size

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0 APR 1983

    7.4 DEC 1985

    8.6.0 APR 2001

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Drawing Text Size (OS 4) (on page 211)

  • Option Switches

    ISOGEN Option Switches Reference Guide 19

    Option Switch 5: Coordinates (Connection/Connectivity)

    Controls the selective suppression from the isometric drawing of the coordinate information that is associated with each of the seven pipeline end connection/termination identifiers in -30 and -36 type records, and at any break-in point (BIP) identifier position in -47 type records. Each type is controlled by a separate position in the option switch as indicated by the layout graphic in the Switch Layout section.

    The following table lists the coordinate identifiers:

    Purpose ISO Text IDF Record Number

    Continuation on another pipeline CONT. ON -30

    Connected to equipment nozzle CONN. TO -31

    Identify any open end of pipe work User-defined text -32

    Identify any closed end of pipe work User-defined text -33

    Identify a vent position VENT -34

    Identify a drain position DRAIN -35

    Identify any miscellaneous position User-defined text -36

    Identify a break-in point -- -47

    Switch Settings

    The following settings are available for Option Switch 5:

    0 1

    Display ISO text (as shown in the previous table) and associated coordinate information on the isometric drawing. Suppress the display of ISO text and associated coordinate information on the isometrics drawing.

    Switch Layout

    Related Program Development Specifications Version Date

    Dev. No. 29 - End Coords Suppression 5.4 APR 1987

    Dev. No. 47 - Ghost Gap Facility 5.9 MAR 1990

    Related Option Switches

    N/A

    Option Switch Detail Sketch

    Coordinates - Connection/Connectivity (OS 5) (on page 212)

  • Option Switches

    20 ISOGEN Option Switches Reference Guide

    Option Switch 6: Date Output Controls the date format that is output on the isometric drawing and printed listings in a 2- or 4-digit year format. By default, the actual date that the software outputs is taken from either the PDF (pipeline data file) that is created by the host 3D design software or the computer system at the time the drawing is generated.

    There are three format options plus an option switch setting to suppress any date output, even though a date exists in the IDF.

    Switch Settings

    The following settings are available for Option Switch 6:

    SWITCH POSITIONS 1 and 2 - Date Output and Format

    0 1 2 3 10 11 12

    Output the date using British format (14 APR 09). This is the default setting. Output the date using European format (14/04/09). Output the date using American format (04/14/09). Suppress the output of a plotted date. Output the system date in British format. Output the system date in European format. Output the system date in American format.

    SWITCH POSITION 3 - Two- or Four-Digit Year Output

    0 1

    Output the year using a two-digit format. You can also leave the setting blank to generate the same output. Output the year using a four-digit format.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0 APR 1983

    7.0 Release Notes 7.1 JUN 1994

    Dev. No. 74B - Four Digit Year 7.16.0 MAY 1999

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Date Output (OS 6) (on page 219)

  • Option Switches

    ISOGEN Option Switches Reference Guide 21

    Option Switch 7: Pipeline Splitting (User Control) Identifies the method used when splitting two pipelines into multiple isometric drawings. Two methods are available:

    Automatic: This method automatically calculates the number of pipeline graphics that can be displayed on the selected drawing size, and then generates the exact number of isometric drawings that are required to contain the completed pipeline.

    Fixed: This method requires that you specify the number of isometric drawings that are necessary to display the completed pipeline.

    The setting in Position 1 is ignored if manual pipeline split points are present in the piping data file (PDF).

    Since any option switch setting applies to all the pipelines in a run, it is recommended that you only use the fixed method in special cases for single pipeline runs.

    An added option permits any drawing split points input in the 3D model by the user and present in the PDF to be ignored.

    Switch Settings

    The following settings are available for Option Switch 7:

    SWITCH POSITIONS 1 and 2 - Various Controls

    0 Value

    Use automatic splitting to control the number of isometric drawings that are required. Set the number of isometric drawings that are required.

    SWITCH POSITION 3 - Ignore Drawing Split Points

    1 Ignore user-defined drawing split points present in the PDF.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0 APR 1983

    7.7 AUG 1986

    Related Option Switches

    Option Switch 38: Pipeline Splitting (Automatic) (on page 62)

    Option Switch Detail Sheet

    Pipeline Splitting - User Control (OS 7) (on page 220)

  • Option Switches

    22 ISOGEN Option Switches Reference Guide

    Option Switch 8: Dimension Line Standout Controls dimension line standout distances for the following:

    String and composite dimensions that are normally plotted as the middle layer of multi-layer dimensions.

    Dimensioned messages, support messages, and reference dimensions on the inner layer, but only when a standout distance in Option Switch 40 is not set.

    Overall dimensions on the outer layer, but only when a standout distance in Option Switch 118 is not set.

    Values that are less than or equal to 11mm are ignored by the software and substituted by the appropriate standard dimension line standout distance. When the option switch value is greater than 11mm, the software uses that value to set the dimension line standout distance for string and composite dimensions on the middle layer. The inner dimensioned layer for dimensioned messages, support messages, and reference dimensions are then set to be 0.5 times this distance, while the outer layer overall dimensions are set to 1.5 times this distance.

    Dimension text and messages are placed along a section of pipe in isometric projection (oblique angle or slanted text).

    This feature is only available for DXF format output styles generated using the piping object data (POD) interface.

    Text oblique angle is adjusted to be parallel to the dimension standout direction.

    When it is practical to do so, ISOGEN attempts to set a vertical dimension standout for horizontal sections of pipeline

    Switch Settings

    The following settings are available for Option Switch 8:

    0 Value

    Plot standard dimension line standouts. This is the default setting. Set the required standout distance (in whole millimeters), for string and composite dimensions on the middle layer.

    The standard dimension line standout distances for the various drawing sizes are as follows:

    Small-sized drawing text (Option Switch 4, Position 1)

    String/composite dimension standout - 12mm.

    Messages, support and reference dimension standout - 6mm.

    Overall dimension standout - 18mm.

    Medium-sized drawing text (Option Switch 4, Position 0)

    String/composite dimension standout - 14mm.

    Message, support and reference dimension standout - 7mm.

    Overall dimension standout - 21mm

    Large-sized drawing text (Option Switch 4, Position 2)

    String/composite dimension standout - 16mm.

    Message, support and reference dimension standout - 8mm.

    Overall dimension standout - 24mm.

    (continued on the following page)

  • Option Switches

    ISOGEN Option Switches Reference Guide 23

    (continued from the previous page)

    Option Switch 8: Dimension Line Standout

    Extra large-sized drawing text (Option Switch 4, Position 4)

    String/composite dimension standout - 18mm.

    Message, support and reference dimension standout - 9mm.

    Overall dimension standout - 27mm.

    Extra large-sized drawing text (Option Switch 4, Position 3)

    String/composite dimension standout - 20mm.

    Message, support and reference dimension standout - 10mm.

    Overall dimension standout - 30mm.

    Extra large-sized drawing text (Option Switch 4, Position 5)

    String/composite dimension standout - 22mm.

    Message, support and reference dimension standout - 11mm.

    Overall dimension standout - 33mm.

    SWITCH POSITION 3 - Isometric Text

    0 1

    Use standard text. Use isometric text.

    SWITCH POSITION 4 - Vertical Dimension Standout

    0 1

    Use normal selection criteria to determine directional standout. Use vertical dimension standout whenever possible.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0 APR 1983

    Dev. No. 53 - ISOPLOT Program Update 6.0 MAR 1991

    8.0 Release Notes 7.4 DEC 1995

    Related Option Switches

    Option Switch 4: Drawing Text Size (on page 17)

    Option Switch 118: Dimensions (Overall) (on page 178)

    Option Switch Detail Sheet

    Dimension Line Standout (OS 8) (on page 221)

  • Option Switches

    24 ISOGEN Option Switches Reference Guide

    Option Switch 9: Dimension Form Controls the following dimensioning requirements on the isometric drawing:

    Dimension type, such as string/composite, support/comment, reference location and full string

    Component dimensions to include or exclude gaskets

    USA style dimensions, positioned on top of the dimension line

    Additional allowances for pipe dimensions

    Double dimensioning - imperial or metric

    Dimensioning multi-way valves and instruments

    Dimensioning of only pipe components, with fitting components remaining undimensioned

    Switch Settings

    The following settings are available for Option Switch 9:

    SWITCH POSITION 1 - Various Controls

    0 1 2 3 4 5 6 7

    Plot ordinary string dimensions, support or message dimensions, and reference dimensions on the isometric drawing. This is the default setting. Plot only reference dimensions on the isometric drawing. All other dimensions are suppressed. Plot only support/message and reference location dimensions on the isometric drawing. Plot composited dimensions together with support/message dimensions and reference dimensions on the isometric drawing. Plot full string dimensions, support/message dimensions, and reference dimensions on the isometric drawing. All components are individually dimensioned. Plot ordinary string dimensions but do not dimension separately erection pipe fittings--such as bends, elbows, tees, and so forth--support/message dimensions, and reference dimensions on the isometric drawing. Plot composite dimensions but do not dimension separately erection pipe fittings--such as bends, elbows, tees, and so forth--support/message dimensions, and reference dimensions on the isometric drawing. Plot pipe dimensions, support/message dimensions and reference dimensions on the isometric drawing. Suppress dimensioning of all fittings.

    SWITCH POSITION 2 - Dimensioning of Gaskets

    0 1 2

    Exclude gaskets in component dimensions. Include gaskets in component dimensions. Dimension gaskets separately.

    (continued on the following page)

  • Option Switches

    ISOGEN Option Switches Reference Guide 25

    (continued from the previous page)

    Option Switch 9: Dimension Form

    SWITCH POSITION 3 - USA Style Dimensions

    Blank 1

    Use the regular dimensioning style, whereby dimensions are inserted into the dimension line. Use the USA dimensioning style, whereby dimensions are positioned on top of the dimension line.

    SWITCH POSITION 4 - Dimensions at 90-Degrees

    0 1

    Turn dimensions 90-degrees rather than being arrowed out. Arrow out dimensions.

    SWITCH POSITION 5 - Show Additional Allowances with Dimension Output

    0 1 2

    Output normal component dimensions on the isometric drawing. Display additional allowances with component dimension output. Include additional allowances with component dimension output.

    SWITCH POSITION 6 - Bend Dimensioning

    0 1

    Combine pipe and bend dimensions on the isometric drawing. Separate pipe and bend dimensions on the isometric drawing.

    SWITCH POSITION 7 - Double Dimensioning (Imperial and Metric)

    0 1

    Use single dimensioning. Use double dimensioning.

    SWITCH POSITION 8 - Dimensioning of Angle, 3-Way, 4-Way Valves and Instruments

    0 1

    Dimension angle valves, 3-way valves, 4-way valves and instruments using messages. Dimension angle valves, 3-way valves, 4-way valves and instruments as usual.

    SWITCH POSITION 9 - Jacket Dimension Control

    0 1

    Allow full jacket dimensioning. Suppress full jacket dimensioning.

    (continued on the following page)

  • Option Switches

    26 ISOGEN Option Switches Reference Guide

    (continued from the previous page)

    Option Switch 9: Dimension Form

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0 APR 1983

    Dev. No. 19 - Improved Dimensioning 5.0 OCT 1986

    Dev. No. 59 - Dimensioning Upgrade 7.0 OCT 1993

    Dev. No. 83F - Dimensioning Enhancements 8.5.4 DEC 2000

    Dev. No. 89D - Jacket Piping Systems 8.6.0 FEB 2001

    Dev. No. 86E - Dimensioning of Pulled Bends 8.7.0 APR 2001

    9.0.0 Release Notes 9.0 MAY 2008

    10.1.0 Release Notes 10.1.0 NOV 2010

    Related Option Switches

    Option Switch 40: Pipe Supports (on page 67)

    Option Switch 118: Dimensions (Overall) (on page 178)

    Option Switch 119: Dimensions/Elevations (Vertical) (on page 179)

    Option Switch Detail Sheet

    Dimension Form (OS 9) (on page 222)

  • Option Switches

    ISOGEN Option Switches Reference Guide 27

    Option Switch 10: Drawing Margin (Left) Controls the left-hand side of the drawing margin. The drawing margin is the distance between the outer edge of the drawing sheet and the outer line of the drawing frame that is being used.

    Switch Settings

    The following switch settings are available for Option Switch 10:

    SWITCH POSITIONS 1, 2 and 3 - Drawing Margin (Left-Side)

    0 Value

    Use a setting of 5mm for the left margin. This is the default setting. Set the left-margin in whole millimeters.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0 APR 1983

    Related Option Switches

    Option Switch 11: Drawing Margin (Right) (on page 28)

    Option Switch 12: Drawing Margin (Top) (on page 29)

    Option Switch 13: Drawing Margin (Bottom) (on page 30)

    Option Switch Detail Sheet

    Drawing Margins (OS 10, 11, 12, & 13) (on page 227)

  • Option Switches

    28 ISOGEN Option Switches Reference Guide

    Option Switch 11: Drawing Margin (Right) Controls the right-hand side drawing margin. The drawing margin is the distance between the outer edge of the drawing sheet and the outer line of the drawing frame that is being used.

    Switch Settings

    The following settings are available for Option Switch 11:

    SWITCH POSITIONS 1, 2 and 3 - Drawing Margin (Right-Side)

    0 Value

    Use a setting of 5mm for the right margin. This is the default setting. Set the right-margin in whole millimeters.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    Option Switch 10: Drawing Margin (Left) (on page 27)

    Option Switch 12: Drawing Margin (Top) (on page 29)

    Option Switch 13: Drawing Margin (Bottom) (on page 30)

    Option Switch Detail Sheet

    Drawing Margins (OS 10, 11, 12, & 13) (on page 227)

  • Option Switches

    ISOGEN Option Switches Reference Guide 29

    Option Switch 12: Drawing Margin (Top) Controls the drawing margin at the top of the drawing. The drawing margin is the distance between the outer edge of the drawing sheet and the outer line of the drawing frame that is being used.

    Switch Settings

    The following settings are available for Option Switch 12:

    SWITCH POSITION 1, 2 and 3 - Drawing Margin (Top)

    0 Value

    Use a setting of 5mm for the top margin. This is the default setting. Set the top margin in whole millimeters.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    Option Switch 10: Drawing Margin (Left) (on page 27)

    Option Switch 11: Drawing Margin (Right) (on page 28)

    Option Switch 13: Drawing Margin (Bottom) (on page 30)

    Option Switch Detail Sheet

    Drawing Margins (OS 10, 11, 12, & 13) (on page 227)

  • Option Switches

    30 ISOGEN Option Switches Reference Guide

    Option Switch 13: Drawing Margin (Bottom) Controls the drawing margin at the bottom of the drawing. The drawing margin is the distance between the outer edge of the drawing sheet and the outer line of the drawing frame that is being used.

    Switch Settings

    The following settings are available for Option Switch 13:

    SWITCH POSITION 1, 2 and 3 - Drawing Margin (Bottom)

    0 Value

    Use a setting of 5mm for the bottom margin. This is the default setting. Set the bottom margin in whole millimeters.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    Option Switch 10: Drawing Margin (Left) (on page 27)

    Option Switch 11: Drawing Margin (Right) (on page 28)

    Option Switch 12: Drawing Margin (Top) (on page 29)

    Option Switch Detail Sheet

    Drawing Margins (OS 10, 11, 12, & 13) (on page 227)

  • Option Switches

    ISOGEN Option Switches Reference Guide 31

    Option Switch 14: Drawing Size (Standard Postscript Plotter Size)

    Controls the drawing size when a standard drawing conforming to the European Metric A series or an inch-based American ANSI paper sizes A to E is required. A secondary function controlled by this option switch is the setting of the postscript output device size for both standard and nonstandard drawing sizes.

    Nonstandard drawing sizes are controlled by Option Switches 15 and 16. If set, these override any setting in Option Switch 14.

    Switch Settings

    The following settings are available for Option Switch 14:

    SWITCH POSITION 1 and 2 - Drawing Sheet Size

    0 1 2 3 4 10 5 6 7 8 9

    Set European A2 paper size (420 x 594 mm) as the default size. Use European A1 paper size (594 x 841 mm). Use European A2 paper size (420 x 594 mm). Use European A3 paper size (297 x 420 mm). Use European A4 paper size (210 x 297 mm). Use European A0 paper size (841 x 1189 mm). Use ANSI D paper size (22" x 34"). Use ANSI C paper size (17" x 22"). Use ANSI B paper size (11" x 17"). Use ANSI A paper size (8 1/2" x 11"). Use ANSI E paper size (34" x 44").

    SWITCH POSITION 3 and 4 - Postscript Plotter Size

    0 or blank 1 2 3 4 10 5 6 7 8 9

    Set the default paper size as European A (297 x 420 mm). Use European A1 paper size (594 x 841 mm). Use European A2 paper size (420 x 594 mm). Use European A3 paper size (297 x 420 mm). Use European A4 paper size (210 x 297 mm). Use European A0 paper size (841 x 1189 mm). Use ANSI D paper size (22" x 34"). Use ANSI C paper size (17" x 22"). Use ANSI B paper size (11" x 17"). Use ANSI A paper size (8 1/2" x 11"). Use ANSI E paper size (34" x 44").

    (continued on the following page)

  • Option Switches

    32 ISOGEN Option Switches Reference Guide

    (continued from the previous page)

    Option Switch 14: Drawing Size (Standard PostScript Plotter Size)

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    6.0 Release Notes 6.0 MAR 1991

    Related Option Switches

    Option Switch 15: Drawing Size (Height) (on page 33)

    Option Switch 16: Drawing Size (Width) (on page 34)

    Option Switch Detail Sheet

    Drawing Size - Standard and PostScript Plotter Size (OS 14) (on page 228)

  • Option Switches

    ISOGEN Option Switches Reference Guide 33

    Option Switch 15: Drawing Size (Height) Defines isometric drawing height for nonstandard paper sizes. That is, sizes that do not conform to either the European A series or the inch-based American ANSI sizes.

    Where the plotted output is to a postscript output device, the device size must be set in Option Switch 14, unless European A3 size is being used.

    Standard drawing sizes are controlled by Option Switch 14.

    Switch Settings

    The following settings are available for Option Switch 15:

    SWITCH POSITION 1, 2, 3 and 4 - Drawing Size - Height

    0 Value

    Set as the default for no nonstandard height. Set the value for the overall drawing height in whole millimeters.

    This option switch MUST be used in conjunction with Option Switch 16 - Drawing Size (Width).

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    Option Switch 14: Drawing Size (Standard PostScript Plotter Size) (on page 31)

    Option Switch 16: Drawing Size (Width) (on page 34)

    Option Switch Detail Sheet

    Drawing Size - Height and Width (OS 15 & 16) (on page 229)

  • Option Switches

    34 ISOGEN Option Switches Reference Guide

    Option Switch 16: Drawing Size (Width) Defines isometric drawing width for nonstandard paper sizes. That is, sizes that do not conform to either the European A series or the inch-based American ANSI sizes.

    Where the plotted output is to a postscript output device, the device size must be set in Option Switch 14, unless European A3 size is being used.

    Standard drawing sizes are controlled by Option Switch 14.

    Switch Settings

    The following settings are available for Option Switch 16:

    SWITCH POSITION 1, 2, 3 and 4 - Drawing Size - Width

    0 Value

    Set as the default for no nonstandard drawing width. Set the value for the overall drawing width in whole millimeters.

    This option switch must be used in conjunction with Option Switch 15 - Drawing Size (Height) (on page 33).

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    Option Switch 14: Drawing Size (Standard Postscript Plotter Size) (on page 31)

    Option Switch 15: Drawing Size (Height) (on page 33)

    Option Switch Detail Sheet

    Drawing Size - Height and Width (OS 15 & 16) (on page 229)

  • Option Switches

    ISOGEN Option Switches Reference Guide 35

    Option Switch 17: Flow Arrows/Gaskets (Components)

    Controls the use of flow arrows that are plotted alongside certain types of in-line components. Their purpose is to show a pipeline's fluid or gas flow direction.

    A different type of user-positioned flow arrow which is plotted directly on the pipe may also be used either as well as or instead of the component flow arrow. For details of this alternative type, see Option Switch 112: Flow Arrows (Pipeline) (on page 172).

    Switch Settings

    The following settings are available for Option Switch 17:

    SWITCH POSITION 1 - Flow Arrows - Components

    0 1

    Plot flow arrows alongside certain types of in-line components. This is the default setting. Suppress the plotting of component flow arrows.

    SWITCH POSITION 2 - Gaskets - Components

    0 1

    Suppress output of gasket fitting shape on isometric drawing. Output gasket fitting shape on isometric drawing.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR1983

    8.11.0 Release Notes 10.0.0 APR 2010

    Related Option Switches

    Option Switch 112: Flow Arrows (Pipeline) (on page 172)

    Option Switch Detail Sheet

    Flow Arrows - On Components (OS 17) (on page 230)

  • Option Switches

    36 ISOGEN Option Switches Reference Guide

    Option Switch 18: Drawing Frame (Program Standard) Controls whether the standard ISOGEN drawing frame is plotted. It is likely that users who either plot their own design backing frame or plot to frame on preprinted forms will want to suppress the plotting of the standard ISOGEN drawing frame.

    Switch Settings

    The following settings are available for Option Switch 18:

    SWITCH POSITION 0, 1 - Drawing Frame - Program Standard

    0 1

    Obtain the standard ISOGEN drawing frame. This is the default. Suppress the plotting of the ISOGEN drawing frame.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Drawing Frame - Program Standard (OS 18) (on page 231)

  • Option Switches

    ISOGEN Option Switches Reference Guide 37

    Option Switch 19: Sloping Pipeline (Indication Method)

    Controls how sections of falling pipelines, that is, downward slopes, are indicated on the isometric drawing. The switch determines the method of how the fall value is numerically indicated on the isometric drawing from one of the following options. A further option suppresses fall type slope indication.

    Switch Settings

    The following settings are available for Option Switch 19:

    SWITCH POSITION 1 - Fall Depiction

    0 1 2 3 4 5 6

    Show falls as an angle, for example, Fall 1.5 . This is the default. Show falls as a ratio, for example, Fall 1:38. Show falls as a percentage, for example, Fall 2.6%. Show falls as a gradient, for example, Fall 1.6 GRAD. Show falls as an Imperial incline, for example, 5/16" per foot. Show falls as metric incline, for example, Fall 26 mm per m. Suppress falling line indication.

    SWITCH POSITION 2 - Accuracy of Sloping Pipeline Indication

    Fall shown as an Angle

    0 1 2 3

    Output angle to nearest 10th degree. Output angle to nearest degree. Output angle to nearest 100th degree. Output angle to nearest degree and minutes.

    Fall shown as an Ratio

    0 1 2

    Output ratio to nearest 5 when greater than 1:30. Output ratio to nearest 5 when greater than 1:100. Output ratio to nearest 1.

    Fall shown as an Percentage

    0 1 2

    Output percentage to nearest whole value. Output percentage to nearest 1 decimal place. Output percentage to nearest 2 decimal places.

    Fall shown as an Gradient

    0 1 2

    Output gradient to nearest 10th grad. Output gradient to nearest grad. Output gradient to nearest 100th grad.

    Fall shown as an Imperial Incline (only when dimensions in decimal inches)

    0 1

    Output incline to nearest 16th of an inch per foot. Output Incline to nearest 100th of an inch per foot.

    (continued on the following page)

  • Option Switches

    38 ISOGEN Option Switches Reference Guide

    (continued from the previous page)

    Option Switch 19: Sloping Pipeline (Indication Method)

    Fall shown as an Metric Incline

    0 1 2

    Output incline to nearest 5mms per meter. Output incline to nearest mm per meter. Output incline to nearest 10mms per meter.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    8.11.0 Release Notes 8.11.0 APR 1983

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Sloping Pipeline Indication Method (OS 19) (on page 232)

  • Option Switches

    ISOGEN Option Switches Reference Guide 39

    Option Switch 20: Sloping Pipeline (Indication Limit) Controls the cut-off value used for determining what steepness of slope should be treated as a fall and what should not.

    Slopes steeper than the cut-off value are shown with a 2D or 3D box or triangle skew indication, as appropriate.

    Switch Settings

    The following settings are available for Option Switch 20:

    SWITCH POSITION 0 - Sloping Pipeline Indication Limit

    0 Value

    Set to 5 angle cut-off, or its equivalent, depending on the type of indication selected in Option Switch 19. This is the default. Set to a cut-off number to suit the type of indication selected in Option Switch 19. For example:

    For 5 cut-off, enter 5 or 0.

    For 1:11 ratio cut-off, enter 11.

    For 9% cut-off, enter 9.

    For 5 Grads cut-off, enter 5.

    For 1" per foot cut-off, enter 1.

    For 88 mm per meter cut-off, enter 88.

    When sloping pipeline indications has been suppressed by setting OS 19 = 6, this OS 20 should always be set to 0.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    Option Switch 19: Sloping Pipeline (Indication Method) (on page 37)

    Option Switch Detail Sheet

    Sloping Pipeline Indication Limit (OS 20) (on page 233)

  • Option Switches

    40 ISOGEN Option Switches Reference Guide

    Option Switch 21: Isometric Type Controls the required isometric type.

    Switch Settings

    The following settings are available for Option Switch 21:

    SWITCH POSITIONS 1 and 2 - Isometric Type

    0 1 2 4 5 6 7 10 11 12 16

    Generate a combined isometric drawing, which contains a combination of fabrication, erection, and offshore information as appropriate. This is the default setting. Generate an erection/offshore isometric drawing. Generate a fabrication only isometric drawing. Generate individual flat spool isometric drawings (maximum legs flat). Generate individual flat spool isometric drawings (maximum legs parallel). Generate individual spool isometric drawings (as-built orientation). Suppress isometric drawing generation. Generate a combined material list without pipeline graphics. Generate an erection material list without pipeline graphics. Generate a fabrication material list without pipeline graphics. Generate a spool material list without spool graphics.

    SWITCH POSITION 3 - Test Isometric

    0 1 8 9

    Generate a normal isometric drawing. Generate a test isometric drawing with all dimensions and material list quantities output as Xs. Do not decrement the hardware lock count. Increase tolerance to join disconnected components. Set to 8 mm. Produce separate drawings for disconnected pipeline when increased tolerance is used and Option Switch 55 Position 3 is set to 0.

    Values 8 and 9 are set internally and do not require you to take any action. When a minor break occurs at the bypass closure point, IDFGEN sets switch position 3 to 8 so that ISOGEN will still recognize the bypass situation that has been created. IDFGEN sets switch position 3 to a value of 9 when certain conditions of Option Switch 55 are met. In these situations, ISOGEN outputs a disconnected pipeline message when necessary.

    SWITCH POSITION 4 - Isometric Style

    0 1

    Generate a piping isometric drawing. Generate a tracing isometric drawing.

    (continued on the following page)

  • Option Switches

    ISOGEN Option Switches Reference Guide 41

    (continued from the previous page)

    Option Switch 21: Isometric Type

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev. No. 63 - Flat Spools Facility 7.1.0 JUN 1994

    Dev. No. 63A - Isometric Test Facility 7.4.2 JAN 1996

    Dev. No. 74A - Disconnected Pipelines 7..16.0 MAY 1999

    Dev. No. 91L - Heat Tracing 8.12.0 FEB 2005

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Isometric Type (OS 21) (on page 234)

  • Option Switches

    42 ISOGEN Option Switches Reference Guide

    Option Switch 22: Cut Piece Add-On Allowances Controls the amount of extra pipe that is added under the following circumstances:

    At loose flange and field fit weld (FFW) positions. Extra pipe is added to cut pipe length dimensions and pipe quantities on the material list. There are separate settings to control on-shore and off-shore values.

    For shop test purposes when certain welds are cut off together with a short length of pipe after testing.

    Switch Settings

    The following settings are available for Option Switch 22:

    SWITCH POSITIONS 1, 2, and 3 - FFW / Loose Flange Allowance (On-Shore)

    0 Value

    Set the allowance to 0 mm. This is the default setting. Set an alternative allowance in whole millimeters.

    SWITCH POSITIONS 4, 5, and 6 - FFW / Loose Flange Allowance (Off-Shore)

    0 Value

    Set the allowance to 0 mm. This is the default setting. Set an alternative allowance in whole millimeters.

    SWITCH POSITIONS 7, 8, and 9 - Shop Test Weld Allowance

    0 Value

    Set the allowance to 0 mm. This is the default setting. Set an alternative allowance in whole millimeters. This setting is only applied to shop test welds.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev. No. 57 - Welding Facilities Upgrade 7.0.0 OCT 1993

    Dev. No. 63 - Flat Spool Facility 7.1.0 JUN 1994

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Cut Piece Add-On Allowances (OS 22) (on page 241)

  • Option Switches

    ISOGEN Option Switches Reference Guide 43

    Option Switch 23: Material List (Controls/File Type) Controls the following integral material list functions on the isometric drawing:

    Material list on/off

    Special type of list

    Material list style

    Material control file type

    Continuous or sectionalized material list

    If you do not require a material list or obtain the material list by alternative means, such as by printing it, you can suppress its output.

    Switch Settings

    The following settings are available for Option Switch 23:

    SWITCH POSITION 1 - Material List On/Off

    0 1

    Plot the material list integrally with the isometric drawing. Suppress plotting of the material list.

    SWITCH POSITION 2 - Special Type Material Lists

    0 1 2

    Suppress special type of material list. This is the default setting. Use special type of material list. Every item is given a separate entry, except gaskets and bolts which are accumulated. Pulled bends have a "U" prefix, and welds have a "W" or "B" prefix. Suppress special type of material list. Use an alpha system of material list pointers (A, B, C, and so on) instead of the default numeric system.

    SWITCH POSITION 3 - Material List Style

    0 or 1 2 3 4

    Use Style 1 material list. This is the default setting. Use Style 2 material list. Use Style 3 material list. Use Style 4 material list.

    SWITCH POSITION 4 - Type of Material Control File

    0 1

    Use the standard material control file. This is the default setting. Use the user-defined material control file.

    (continued on the following page)

  • Option Switches

    44 ISOGEN Option Switches Reference Guide

    (continued from the previous page)

    Option Switch 23: Material List (Controls/File Type)

    SWITCH POSITION 5 - Style 2 Material List Layout Pattern

    This position is similar to setting OS 23 Pos 2=1.

    Blank 1 2

    Use the standard sectionalized layout. This type of list has group headings and component sub-group headings. Use the continuous style layout without headings and sub-headings. This type of list is partitioned between the logical groups, such as PIPE, FLANGES, FITTINGS, and so on. Use the standard sectionalized layout without dividing lines.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev. No. 56 - User Defined Material List 7.0.0 OCT 1993

    Dev. No. 65N Alphabetic Material List Identifiers 7.4.0 DEC 1995

    Dev. No. 67A Style 4 Material List 7.6.0 MAY 1996

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Material List - Controls & M/C File Type (OS 23) (on page 242)

  • Option Switches

    ISOGEN Option Switches Reference Guide 45

    Option Switch 24: Material List (Pipeline/Drawing/Pipe Length Units)

    Controls the following two aspects of the material list:

    Output is on a per drawing or per pipeline basis.

    This difference only comes into effect when a pipeline is split onto two or more drawings.

    Linear quantity output style.

    Switch Settings

    The following settings are available for Option Switch 24:

    SWITCH POSITION 1 - Material List per Drawing or per Pipeline

    0 1 2 3

    Output a material list on a per drawing basis. This is the default setting. Output a material list on a per pipeline basis. Output spool isometric material part numbers to match full isometric part numbers when using material list per drawing facility. Output spool isometric material part numbers to match full isometric part numbers when using material list per pipeline facility.

    SWITCH POSITION 2 - Linear Quantity Output Style

    Blank 1 2 3

    Output pipe length in the format n.n M (10.4 M) or n.n Feet (10.4'). This is the default setting. Output pipe length in the format n MM (1040 MM) or n Feet n Inches (10' 5"). Output pipe length in the format n.nnn M (1.045 MM) or n.nnn Feet (10.375'). Output pipe length to match the format specified in Option Switch 41. The selected pipe length style is applied on the material list and the cut list length summary for pipe material entries and miscellaneous components

    Metric or imperial unit output is controlled by Option Switch 42.

    SWITCH POSITION 3 - Material by Spool

    0 1

    Group spool materials within Fabrication category. Group spool materials separately, part numbering per spool.

    SWITCH POSITION 4 - Calculation of Bend/Elbow Lengths

    0 1

    Determine centerline lengths of bends/elbows by calculating distance around curve. Determine centerline lengths of bends/elbows by calculating distance to intersection.

    (continued on the following page)

  • Option Switches

    46 ISOGEN Option Switches Reference Guide

    (continued from the previous page)

    Option Switch 24: Material List (Pipeline/Drawing/Pipe Length Units)

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev. No. 56 - User Defined Material List 7.0.0 OCT 1993

    7.6.2 MAY 1996

    8.10.0 Release Notes 8.10.5 NOV 2002

    Dev. No. 97 - Material - Grouping Fabrication Items by Spool

    9.0.0 MAY 2008

    9.3.0 Release Notes 9.3.0 JUN 2009

    Related Option Switches

    Option Switch 23: Material List (Controls/File Type) (on page 43)

    Option Switch 25: Material List Position/Title Block Position (on page 47)

    Option Switch 26: Material List (Descriptions) (on page 48)

    Option Switch 27: Material List (Text Size) (on page 49)

    Option Switch 28: Material List (Item Code Length) (on page 50)

    Option Switch 29: Material List (Line Spacing) (on page 51)

    Option Switch 30: Material List (Continuation Method) (on page 52)

    Option Switch Detail Sheet

    Material List - Pipeline/Drawing (OS 24) (on page 251)

  • Option Switches

    ISOGEN Option Switches Reference Guide 47

    Option Switch 25: Material List Position/Title Block Position

    Controls the following aspects of the material list:

    Position of the material list on the isometric drawing.

    Position of the title block on the isometric drawing.

    Switch Settings

    The following settings are available for Option Switch 25:

    SWITCH POSITION 1 - Material List Position

    0 1

    Print the material list on the left-side of the isometric drawing. This is the default setting. Print the material list on the right-side of the isometric drawing.

    SWITCH POSITION 2 - Title Block Position

    0 1 2

    Print the title block in the default position (bottom right-corner of the pipeline drawing area). Print the title block at the bottom of the material list. Suppress output of the title block.

    SWITCH POSITION 3 - Default Weld Box Position

    1 2

    Print weld box at bottom right corner of drawing. Print weld box at bottom left corner of drawing

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev. No. 56 - User Defined Material List 7.0 OCT 1993

    8.8.0 JUN 2001

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Material List - Position (OS 25) (on page 254)

  • Option Switches

    48 ISOGEN Option Switches Reference Guide

    Option Switch 26: Material List (Descriptions) Controls whether item descriptions are printed on the material list and in the bulk materials file.

    Switch Settings

    The following settings are available for Option Switch 26:

    SWITCH POSITION 1 - Item Descriptions On/Off

    0 1

    Print item descriptions. This is the default setting. Suppress output of item descriptions.

    SWITCH POSITION 2 - Insertion of Blank Lines Following Single Line Material List Entries

    0 or Blank 1

    Insert blank lines. This is the default setting. Suppress insertion of blank lines following single line entries. This setting makes the material list shorter.

    SWITCH POSITION 3 - Output of Descriptions in Bulk Material File

    Blank 1 2

    Suppress output of descriptions. This is the default setting. Output no repeat descriptions. Output all descriptions.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    7.0 Release Notes 7.1.0 JUN 1994

    7.14.4 JUL 1998

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Material List - Descriptions (OS 26) (on page 257)

  • Option Switches

    ISOGEN Option Switches Reference Guide 49

    Option Switch 27: Material List (Text Size) Controls the text size of the plotted material list.

    Switch Settings

    The following settings are available for Option Switch 27:

    SWITCH POSITIONS 1 & 2 - Character Height

    0 1 2 3 4 5 10-99

    Plot characters 2.4 mm high. This is the default setting. Plot characters 2.1mm high. Plot characters 2.8 mm high. Plot characters 3.5 mm high. Plot characters 4.2 mm high. Plot characters 4.9 mm high. Plot characters in 1/10 mms.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    7.2.0 DEC 1995

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Material List - Text Size (OS 27) (on page 258)

  • Option Switches

    50 ISOGEN Option Switches Reference Guide

    Option Switch 28: Material List (Item Code Length) Controls the number of characters ISOGEN uses for the material list item code.

    Switch Settings

    The following settings are available for Option Switch 28:

    0 8

    Use 8 characters in the item code. This is the default setting. Set the number of characters used in the item code in whole numbers.

    The maximum number of characters allowed is 29.

    A value of 0 provides 8 characters. It does not suppress the item code on the Style 1 material list.

    Changes in this field cause the material list to be correspondingly wider or narrower.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    N/A

    Option Switch Detail Sketch

    Material List - Item Code Length (OS 28) (on page 259)

  • Option Switches

    ISOGEN Option Switches Reference Guide 51

    Option Switch 29: Material List (Line Spacing) Controls the line spacing distance on the plotted material list.

    Switch Settings

    The following settings are available for Option Switch 29:

    0 or 100 Value

    Set the line spacing value to 0 or 100. This is the default setting Increase or decrease the line spacing distance in the ration of Value/100. For example, setting the value to 90 reduces the line spacing, while setting the value to 110 increases it.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Material List - Line Spacing (OS 29) (on page 260)

  • Option Switches

    52 ISOGEN Option Switches Reference Guide

    Option Switch 30: Material List (Continuation Method) Controls how a material list overflow situation is handled and how any overflow drawing is identified. A secondary option controls which method is used to identify single isometric pipelines on the drawing sheet.

    Switch Settings

    The following settings are available for Option Switch 30:

    SWITCH POSITIONS 1 and 2

    0 1 2 10 11 12

    Gives automatic overflow onto a second material list plotted alongside the first, which creates a wider, non-standard drawing size. This is the default setting. Gives a second dummy isometric drawing that contains the overflow material list but no pipeline graphics. The isometric drawing is assigned the next drawing sheet identifier in the sequence. Gives a second dummy isometric drawing that contains the overflow material list but no pipeline graphics. The isometric drawing is assigned the same drawing sheet identifier as the previous (master) isometric drawing but suffixed with the letter "A". Additional overflow drawings for the master isometric drawing are suffixed with "B", "C", and so on. Gives the same value as the setting 0, except that DRG 1 OF 1 is added to any single sheet isometric drawings for identification. Gives the same value as the setting 1, except that DRG 1 OF 1 is added to any single sheet isometric drawings for identification. Gives the same value as the setting 2, except that DRG 1 OF 1 is added to any single sheet isometric drawings for identification.

    SWITCH POSITION 3 - Sheet Numbering: Leading Zeroes

    0 x

    Output no leading characters before cut piece number. Output the specified number of characters in cut piece number.

    (continued on the following page)

  • Option Switches

    ISOGEN Option Switches Reference Guide 53

    (continued from the previous page)

    Option Switch 30: Material List (Continuation Method)

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev. No. 48 - Repeatability (Phase 1) 5.9.0 MAR 1990

    9.0 Release Notes 9.0.0 MAY 2008

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Material List - Continuation Method (OS 30) (on page 261)

  • Option Switches

    54 ISOGEN Option Switches Reference Guide

    Option Switch 31: Drawing Output (File/Screen) Controls the following:

    How and where any isometric drawing is to be output

    Whether plot files previously created can be overwritten if their names match those currently being created

    Drawing sheet numbering

    Switch Settings

    The following settings are available for Option Switch 31:

    SWITCH POSITION 1 - General Plotfile Control

    0 1 2 3

    Output isometric drawings generated during a run to either a single plot file or a series of plot files, depending upon the PLOTFILE LENGTH value set in Option Switch 1. Generate an individual plot file for each isometric drawing. Output the generated drawing(s) to the workstation screen. The terminal type to use is set in Option Switch 69. Output multiple isometric drawings on separate sheets. This setting is valid only for SmartSketch (.igr) and Shape 2D (.sha) file formats.

    SWITCH POSITION 2 - Plotfile Overwrite Control

    0 1

    Allocate next available plot file. Generate name using selected sequence method. Allocate plot file name using selected sequence method after deleting previously generated files.

    SWITCH POSITIONS 3 through 5 - Drawing Sheet Numbering

    0 x

    Commence first sheet at drawing number 1. Commence first sheet at drawing number x+1.

    (continued on the following page)

  • Option Switches

    ISOGEN Option Switches Reference Guide 55

    (continued from the previous page)

    Option Switch 31: Drawing Output (File/Screen)

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Dev.No. 87F Plotfile Overwriting 8.7.0 APR 2001

    8.13.0 Release Notes 8.13.0 SEP 2006

    Related Option Switches

    Option Switch 1: Plotfile Length (on page 12)

    Option Switch 36: Drawing Output (Stacking Value) (on page 60)

    Option Switch 37: Drawing Output (Stacking Orientation) (on page 61)

    Option Switch 69: Terminal Type Identification (on page 110)

    Option Switch 71: Plotfile Format (on page 113)

    Option Switch Detail Sheet

    Drawing Output - File/Screen (OS 31) (on page 263)

  • Option Switches

    56 ISOGEN Option Switches Reference Guide

    Option Switch 32: Drawing Output (Scaling) Allows the increase or decrease of the final plotted isometric size, and thus changes it from what is defined by Option Switches 14, 15, and 16.

    Switch Settings

    The following settings are available for Option Switch 32:

    0 to 100 Value

    Allows no change in scaling and generates an isometric drawing at the size defined either by Option Switch 14 or by a combination of Option Switches 15 and 16. Increases or decreases the final isometric size in the ratio of Value/100. For example, a value of 71 generates a drawing at 71% of the original size; a value of 120 generates a drawing at 120% of the original size.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    6.0 Release Notes 6.0.0 MAR 1991

    Related Option Switches

    Option Switch 14: Drawing Size (Standard Postscript Plotter Size) (on page 31)

    Option Switch 15: Drawing Size (Height) (on page 33)

    Option Switch 16: Drawing Size (Width) (on page 34)

    Option Switch Detail Sheet

    Drawing Output - Scaling (OS 32) (on page 264)

  • Option Switches

    ISOGEN Option Switches Reference Guide 57

    Option Switch 33: Revision/Detailed Marker Used by some 3D design systems to control how the Pipe Detailed/ Pipe Revision database attribute fields are updated after ISOGEN successfully generates a pipeline isometric drawing.

    This option switch has no effect on any output generated by ISOGEN.

    Switch Settings

    The following settings are available for Option Switch 33:

    0 1 2 3

    Suppress updating both the Pipe Detailed and Pipe Revision attribute fields. Update both the Pipe Detailed and Pipe Revision attribute fields. Update only the Pipe Revision attribute field. Update only the Pipe Revision attribute field.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    N/A

  • Option Switches

    58 ISOGEN Option Switches Reference Guide

    Option Switch 34: Drawing Output (Picture Scale) Increases or decreases the scale of the pipeline picture part of the isometric drawing, while leaving the other parts, such as the drawing frame, material list, title block, and line summary areas, unaltered.

    When you use this option switch, the whole of the pipeline picture and all text pointing to it may be re-scaled to make it larger or smaller.

    Switch Settings

    The following settings are available for Option Switch 34:

    0 or 100 Value

    Use normal picture scaling (100%). This is the default setting. Increases or decreases the scaling effect by the amount specified. For example, a value of 71 reduces the size of the drawing 71% of its original size.

    Switch Layout

    Related Program Development Specifications Version Date

    Introduced 1.0.0 APR 1983

    Related Option Switches

    N/A

    Option Switch Detail Sheet

    Drawing Output - Picture Scale (OS 34) (on page 265)

  • Option Switches

    ISOGEN Option Switches Reference Guide 59

    Option Switch 35: Drawing (Reserved Areas) Creates two reserved areas across the bottom of the isometric drawing. One area stretches across the bottom part of the drawing region, while the other area stretches across the bottom of the material list. Once set, both areas are reserved on the drawing frame for related project/pipeline information, and ISOGEN does not automatically plot any information in either area.

    You can use the frame text positioning facility to add information that is included in the pipeline input data file in these areas.

    Switch Settings

    The following settings are available for Option Switch 35:

    SWITCH POSITIONS 1, 2, & 3 - Reserved Area within the Drawing Region

    0 Value

    Allow no reserved area. This is the default setting. Reserve an area equal to the depth of the required area along the bottom of the isometric drawing as specified, measured in whole millimeters up from the outer line of the drawing frame.

    SWITCH POSITIONS 4, 5, & 6 - Reserved Area at the Bot