+ All Categories
Home > Documents > Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic...

Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic...

Date post: 03-Jan-2016
Category:
Upload: job-hardy
View: 220 times
Download: 0 times
Share this document with a friend
28
Optronic Laboratories, Optronic Laboratories, Inc. Inc. Optronic Laboratories Inc. Optronic Laboratories Inc. OL Series 750 Automated OL Series 750 Automated Spectroradiometric Spectroradiometric Measurement System Measurement System - PMTs - Indium Antimodide (InSB) - Silicon (Si) - Mercury Cadmium Telluride (HgCdTe) - Germanium (Ge) - Pyroelectric - Indium Gallium Arsenide (InGaAs) - CCD - Lead Sulphide (PbS) - Cameras - Lead Selenide (PbSe) - Radiometers and Photometers An Advanced Turnkey System for An Advanced Turnkey System for Automated Detector Response Automated Detector Response Measurements Measurements
Transcript

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Optronic Laboratories Inc.Optronic Laboratories Inc. OL Series 750 Automated OL Series 750 Automated

SpectroradiometricSpectroradiometric Measurement System Measurement System

Optronic Laboratories Inc.Optronic Laboratories Inc. OL Series 750 Automated OL Series 750 Automated

SpectroradiometricSpectroradiometric Measurement System Measurement System

- PMTs - Indium Antimodide (InSB)- Silicon (Si) - Mercury Cadmium Telluride (HgCdTe)- Germanium (Ge) - Pyroelectric- Indium Gallium Arsenide (InGaAs) - CCD- Lead Sulphide (PbS) - Cameras- Lead Selenide (PbSe) - Radiometers and Photometers

- PMTs - Indium Antimodide (InSB)- Silicon (Si) - Mercury Cadmium Telluride (HgCdTe)- Germanium (Ge) - Pyroelectric- Indium Gallium Arsenide (InGaAs) - CCD- Lead Sulphide (PbS) - Cameras- Lead Selenide (PbSe) - Radiometers and Photometers

An Advanced Turnkey System for An Advanced Turnkey System for Automated Detector Response Automated Detector Response

MeasurementsMeasurements

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

About Optronic About Optronic Laboratories, Inc.Laboratories, Inc.About Optronic About Optronic

Laboratories, Inc.Laboratories, Inc.Optronic Laboratories, Inc. was established in 1970

by two eminent researchers at NIST (then NBS). Facilities were modeled after NIST, and Optronic

Laboratories, Inc. achieved a worldwide reputation for excellence in light measurement and calibration.

Continuing to work closely with NIST, the development of new instruments and techniques at Optronic Laboratories, Inc. constantly improves the

accuracy and precision of light measurement.

Optronic Laboratories, Inc. was established in 1970 by two eminent researchers at NIST (then NBS). Facilities were modeled after NIST, and Optronic

Laboratories, Inc. achieved a worldwide reputation for excellence in light measurement and calibration.

Continuing to work closely with NIST, the development of new instruments and techniques at Optronic Laboratories, Inc. constantly improves the

accuracy and precision of light measurement.

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

About Optronic About Optronic Laboratories, Inc.Laboratories, Inc.About Optronic About Optronic

Laboratories, Inc.Laboratories, Inc.

In 1998, Optronic Laboratories, Inc. moved into its new 25,000 square foot purpose-built

facility, consolidating and expanding production, R & D and calibration facilities

In 1998, Optronic Laboratories, Inc. moved into its new 25,000 square foot purpose-built

facility, consolidating and expanding production, R & D and calibration facilities

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Spectroradiometers: laboratory & field portable

Spectroradiometers: laboratory & field portable

Broad-band radiometers & photometers: DC, AC, pulsed or modulated sources

Broad-band radiometers & photometers: DC, AC, pulsed or modulated sources

Sphere systems: from 1” to 76” diameter as standard

Sphere systems: from 1” to 76” diameter as standard

NIST-traceable calibration sources, materials & detectors: from 200 nm to 30,000 nm

NIST-traceable calibration sources, materials & detectors: from 200 nm to 30,000 nm

Measurement services: sources, materials & detectors

Measurement services: sources, materials & detectors

Customization/new product development

Customization/new product development

Training, consultation & advice Training, consultation & advice

About Optronic About Optronic Laboratories, Inc.Laboratories, Inc.About Optronic About Optronic

Laboratories, Inc.Laboratories, Inc.Optronic Laboratories’ instruments & services include:

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The heart of any spectroradiometric system is the monochromator, but…

It must give the right bandpasses – not too large and not too small

It must give high spectral purity (low stray light) so only the wavelength of interest is detected

The heart of any spectroradiometric system is the monochromator, but…

It must give the right bandpasses – not too large and not too small

It must give high spectral purity (low stray light) so only the wavelength of interest is detected

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Available in single and double (shown) versions

F/4 optics for high throughput

Very low stray light Numerous special

features for most accurate results

Available in single and double (shown) versions

F/4 optics for high throughput

Very low stray light Numerous special

features for most accurate results

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Large range of gratings available

Optimised for high efficiency

Optimised for wide wavelength range

Optimised for high resolution

Large range of gratings available

Optimised for high efficiency

Optimised for wide wavelength range

Optimised for high resolutionTri-grating mounts change

gratings automaticallyTri-grating mounts change

gratings automatically

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Range of Plug-in input accessories

Choppers (shown) for IR detectors

Automatic control of chopper speed and “open” position stop

Filter-wheel for input attenuation or filtering

Range of Plug-in input accessories

Choppers (shown) for IR detectors

Automatic control of chopper speed and “open” position stop

Filter-wheel for input attenuation or filteringVersatile plug-in chopper or

filter wheel input accessoriesVersatile plug-in chopper or filter wheel input accessories

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Fully automated 11 position blocking-filter wheel

Includes SHUT position for dark current readings

Optimised filters for widest wavelength range

Fully automated 11 position blocking-filter wheel

Includes SHUT position for dark current readings

Optimised filters for widest wavelength rangeBlocking-filter wheel

changes filters automatically Blocking-filter wheel

changes filters automatically

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Blocking filters:how they work

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Gratings diffract light at different angles depending on wavelength

400nm will also diffract at the same angle as 800nm (since 2 x 400 = 800)

A blocking filter removes the 400nm so just 800nm is left

Gratings diffract light at different angles depending on wavelength

400nm will also diffract at the same angle as 800nm (since 2 x 400 = 800)

A blocking filter removes the 400nm so just 800nm is left

400nm +

800nm

400nm +

800nm400nm400nm400nm400nm

800nm800nm

Blocking filter

Blocking filter

grating

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Light passes into the monochromator through the entrance slit, then onto the first collimating mirror.

Light passes into the monochromator through the entrance slit, then onto the first collimating mirror.

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Collimated (parallel) light is directed onto the grating.

Collimated (parallel) light is directed onto the grating.

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The grating diffracts the light, sending each wavelength off at a different angle.

The desired wavelength is collected by the first focussing mirror….

The grating diffracts the light, sending each wavelength off at a different angle.

The desired wavelength is collected by the first focussing mirror….

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

…which focuses it at the middle slit.

A second collimating mirror collects this beam…

…which focuses it at the middle slit.

A second collimating mirror collects this beam…

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

…and collimates it onto a second grating.

Since the second grating is linked to the first, they are at the same angle and hence the same wavelength.

…and collimates it onto a second grating.

Since the second grating is linked to the first, they are at the same angle and hence the same wavelength.

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

This second grating acts like the first, but the spectral purity is increased by many decades.

This second grating acts like the first, but the spectral purity is increased by many decades.

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The pure monochromatic light, at the wavelength desired, is then focussed onto the exit slit and emerges from the monochromator

The pure monochromatic light, at the wavelength desired, is then focussed onto the exit slit and emerges from the monochromator

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

Single and double lamp versions

UV lamp 200nm to 400nm

Tungsten lamp 250nm to 2500nm

Glowbar 1000nm to

30000nm

Single and double lamp versions

UV lamp 200nm to 400nm

Tungsten lamp 250nm to 2500nm

Glowbar 1000nm to

30000nm

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

Optics match the OL Series 750 Monochromators

Easy switching from one source …

Optics match the OL Series 750 Monochromators

Easy switching from one source …

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

…to the other…to the other

Optics match the OL series 750 monochromators

Easy switching from one source …

Optics match the OL series 750 monochromators

Easy switching from one source …

Fully automated switching available

Fully automated switching available

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750 + OL 740-The OL 750 + OL 740-2020

The OL 750 + OL 740-The OL 750 + OL 740-2020

200 to 30,000 nm coverage

monochromatic light prevents sample heating

Suits a very wide range of standard OL accessories

Suits many existing and future applications

200 to 30,000 nm coverage

monochromatic light prevents sample heating

Suits a very wide range of standard OL accessories

Suits many existing and future applications

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Detector Spectral Detector Spectral ResponseResponse

Detector Spectral Detector Spectral ResponseResponse

In order to characterize their performance in a particular applications, single detectors, array detectors and assemblies often need spectral response to be known

For example, photopic detectors can be analysed for V() matching

In order to characterize their performance in a particular applications, single detectors, array detectors and assemblies often need spectral response to be known

For example, photopic detectors can be analysed for V() matching

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Detector Spectral Detector Spectral ResponseResponse

Detector Spectral Detector Spectral ResponseResponse

Measurements are generally consistent with detector use, and may require a large collimated beam, a small spot, a diffuse source or other geometry

Optronic Laboratories, Inc. manufactures a wide range of accessories for most detector measurement requirements, including quantum efficiency

Measurements are generally consistent with detector use, and may require a large collimated beam, a small spot, a diffuse source or other geometry

Optronic Laboratories, Inc. manufactures a wide range of accessories for most detector measurement requirements, including quantum efficiency

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Detector Spectral Detector Spectral ResponseResponse

Detector Spectral Detector Spectral ResponseResponse

Optronic Laboratories, Inc. provides standard detectors, traceable to NIST and other National Laboratories

To illustrate a detector spectral response system, we will use the OL 750-10C All Mirror Collimator

Optronic Laboratories, Inc. provides standard detectors, traceable to NIST and other National Laboratories

To illustrate a detector spectral response system, we will use the OL 750-10C All Mirror Collimator

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750-10CThe OL 750-10CThe OL 750-10CThe OL 750-10C

2 inch diameter beam

Excellent beam uniformity

Constant collimation at all wavelengths

2 inch diameter beam

Excellent beam uniformity

Constant collimation at all wavelengths

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750 + OL 740-The OL 750 + OL 740-20 + OL 750-10C20 + OL 750-10C

The OL 750 + OL 740-The OL 750 + OL 740-20 + OL 750-10C20 + OL 750-10C

If we put these together…If we put these together…

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750 + OL 740-The OL 750 + OL 740-20 + OL 750-10C20 + OL 750-10C

The OL 750 + OL 740-The OL 750 + OL 740-20 + OL 750-10C20 + OL 750-10C

We have a complete system for detector responseWe have a complete system for detector response

First we calibrate with the standard

detector

First we calibrate with the standard

detector

Then we measure the test detector

Then we measure the test detector

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

More InformationMore InformationMore InformationMore Information

The system illustrated represents one of the applications of the OL 750 Series ASMS, others include:

Source Spectral Analysis (Irradiance and Radiance) Transmission (Diffuse and Linear) Reflectance (Diffuse and Specular)

Visit our website at www.olinet.com

The system illustrated represents one of the applications of the OL 750 Series ASMS, others include:

Source Spectral Analysis (Irradiance and Radiance) Transmission (Diffuse and Linear) Reflectance (Diffuse and Specular)

Visit our website at www.olinet.com


Recommended