MAXILLO-FACIAL IMPLANT SYSTEMS - TOI® / SMART 2 / ZSI PALATUM MASTOID ORBITA ZYGOMA
Transcript

MAXILLO-FACIAL IMPLANT SYSTEMS - TOI® / SMART2 / ZSI

PALATUM MASTOID

ORBITA

ZYGOMA

2

TOI®-IMPLANTS

TOI®-IMPLANTS WITH ONE BASE-PLATE

Lateral implant for dental and maxillofacial applications.

Compatibility: Smart2® ATIE® (external standard hex)

Indications:Endosseal anchorage of maxillo-facial epitheses in the regions of the frontal bone, maxillary bone, lateral and upper regions of the nose and the ear; to be used also as tooth and jaw implants. For rehabilitation following radiation therapy or in cases with a reduced bone supply.TOI® implants may be used also as jaw implant and in bi-cortical anchorage.

a) Enossal Ø: 2.3 mmb) Diameter: 2.7 mmc) Head Ø: 3.7 mmGD: Max. Ø on round side

TOI®-IMPLANTS WITH TWO BASE-PLATE

TOI®-IMPLANTS WITH THREE BASE-PLATE

Description SH1 SH2 SA GD REF Price cat.

TOI IED 10 H4 0.6 0.6 3 10 mm 461358 T

TOI IED 5/7 H4 0.6 0.6 3 5x7 mm 461362 T

TOI IED 5/7 H6 0.6 0.6 3 5x7 mm 461363 T

Description SH1 - SH3 SA GD REF Price cat.

TOI IET 5 / 7 H2 0.6 3 5x7 mm 461356 R

TOI IET 5/ 7 H4 0.6 3 5x7 mm 461357 R

TOI IET 5/7 H6 0.6 3 5x7 mm 461361 R

Description SH1 GD REF Price cat.

TOI IE 5/7 H6 0.6 5x7 mm 461370 T

TOI IE 9 H8 0.7 - 0.9 9.5 mm 461359 T

TOI IE 9 H6 0.7 - 0.9 9 mm 461364 T

TOI IE 9/ 12 H2 0.7 - 0.9 9.5 461350 T

TOI IE 9/ 12 H4 0.7 - 0.9 9.5 461351 T

TOI IE 9/ 14 H8 0.7 - 0.9 9.5 461352 T

TOI IE 9/ 14 H10 0.7 - 0.9 9.5 461353 T

TOI IE 9/ 16 H8 0.7 - 0.9 9.5 461360 T

TOI IE 10/ 20 H2 0.7 - 0.9 10 461354 X

TOI IE 10/ 20 H4 0.7 - 0.9 10 461355 X

H2, H4, H6

b

a

cH8, H6

H4

H4

LATERAL IMPLANTS

3

SURGICAL INSTRUMENTS AND TOOLS

Radiograph after placement of three basal implant in the midface. The implants will be splited through a bar which then holds the epithesis to replace the nose.

The implants utilize the width of the bone. The treatment will be finished in a delayed load protocol, because the swelling of the soft tissues must cease first.

Literature: Konstantinovic VS, Lazic V., Ihde S.Disk implants retained nasal epithesis. Case report and literature review. J Craniofac Surg 2010;21: (1) 33-36

Accessories for TOI® and Smart®

Code HLT EO HLTX EO SFL EO IA EO

REF 461365 461366 462361 461373

Transfer post with screw SF EO

Transfer post with screw SF EO

Screw for HLT EO and HLTX EO for pickup-impressions

Implant analogue with Hex

Price cat. B C B C

Lab accessories Surgical screws

Code PAA EO HS EO 3 HS EO 5 HS EO 7 HT 1.25 EO HTX 1.25 EO

REF 462360 461367 461368 461369 462371 462372

Castable abutment, edged inside

Surgical screw, incl. SF EO

for 3 mm trans-mucosal height, incl. SF EO

for 5 mm trans-mucosal height, incl. SF EO

Hex-instrument

Tool: HAS

Hex-instrument extralongTool: HAS

Price cat. B B B B C C

Gingivaformer

4

VER TICAL AND HORIZONTAL CUTTER

CUTTER FOR TOI® - IMPLANTS

CUTTER FOR TOI®IET - IMPLANTS

VERTIKALCUTTER (VC)

COMBINATION CUTTER SIMULTANEOUS CUTTING ON VERTICAL AND HORIZONTAL PART

LATERALCUTTER CUTS ONLY AT THE DISC

Description L DV ** REF Price cat.

VC 1.9 * 32 1.9 462214 F

VC 1.6 * 32 1.6 462215 F

VC 1.9-W *** 1.9 462214-W F

Description L SH SA D REF Price cat.

KC 7-4W 32 0.4 7 462221-4W EKCD 7-4W 32 0.4 3 7 462237-4W E

Description L SH SA D REF Price cat.

LC 7-6W 32 0.6 7 462259-6W D

LC 8-4W 32 0.4 8 462260-4W E

LC 9-6W 32 0.6 9 462261-6W E

LC 10-4W 32 0.4 10 462262-4W E

Description L SH SA D REF Price cat.

ICD5-N 26.7 0.6 3 5 462437-W L

ICT5-N 30.3 0.6 3 5 462415-W L

IC5-N 30.3 0.6 3 5 462438-W L

L = Length in mm; SH = disk height; SA = disk spacing; D = disk diameter

* FG for turbine or red contra-angle** DV = Diameter Vertikalcutter*** for contra-angle

KCD combi double cutter contra-angle

LC 7 lateral cutter contra-angleLC 7 lateral cutter contra-angle

ICD cutterICD cutterICD cutter

ICT cutter

IC cutter

ICT cutter

IC cutter

ICT cutter

LATERAL IMPLANTS

5

SURGICAL INSTRUMENTS AND TOOLS

SSF BONE SCREWS

Description Pieces / pack ø L REF Price cat.

SSF 1.5 6 5metallic silver

1.5 6 401500 B

SSF 1.5 8 5 1.5 8 401502 B

SSF 2.4 6 5

anodized yellow

2.4 6 401506 B

SSF 2.4 8 5 2.4 8 401508 B

SSF 2.4 10 5 2.4 10 401510 B

SSF 2.4 12 5 2.4 12 401512 B

SSF 2.4 14 5 2.4 14 401514 B

SSF 2.7 8 5

anodized blue

2.7 8 401558 B

SSF 2.7 10 5 2.7 10 401560 B

SSF 2.7 12 5 2.7 12 401562 BSSF 2.7 14 5 2.7 14 401564 B

INSTRUMENTS AND TOOLS (STAINLESS STEEL)

Description Code REF Price cat.

Titanium spatula, 17 cm, individually bendable and grindable, Grade 1 titanium TIS 425407 B

Bone and insertion chisel, 13 cm long, custom-grindable KNO 462330 B

Screwdriver tip for contra-angle and adapter 36 mm long ITW SSF 314448 C

Adapter for all angled handpiece instruments, matches handgrip 310530 C

Handgrip, 110 mm long (snap-on connection) 311431 V

Screwdriver tip, 100 mm long, for direct insertion into the handgrip 314447 C

Drill for SSF-bone screws, 1.4 mmd SDW SSF 310520 C

Hex-instrument, 45 mm, Ø 1.25 mm tool: HAS HT 1.25 EO 462371 C

Hex-instrument extralong, 45 mm, Ø 1.25 mm tool: HAS HT X1.25 EO 462372 C

Hex-tool for HT 1.25 EO and HTX 1.25 EO HAS 463108 H

Ratchet, angled for all Hex-instruments and insertion tools RAT 3 425052 S

Ratchet adapter IT ITV 500854 C

DT 1.25 EO DT 1.25 EO 462373 C

10 mm50 mm

10 mm

1.25 mm

1.25 mm

60°

6

INSTRUMENT TRAY

Autoclavable up to 134° C

INSTRUMENT - TRAY FOR ORTHODONTISCHE AND EXTRA-ORALE IMPLANTATE

Size of closed tray B = 105 mm / L = 230 mm / H = 55 mm for all autoclaves

CONTENT

Description Code REF Price €Caliper 4.1 900306Caliper 4.8 900310Explantation cutter 900308Formdrill, for EO FBS EO 3.5 900312Formdrill FBS 4.1 900313Formdrill FBS 4.8 900314Twistdrill DS 2 425001Twistdrill DS 2.8 425005Twistdrill DS 3.5 425009Twistdrill DS 4.2 425013Verticalcutter VC 1.9 462214Verticalcutter VC 1.9-W 462214-WCombinationcutter KC 7-4 W 462221-4WCombinationcutter KCD 7-4W 462237-4WLateralcutter LC 7-6W 462259-6WLateralcutter LC-8-4W 462260-4WLateralcutter LC9-6W 462261-6WLateralcutter LC10-4W 462262-4WCutter for TOI®IET implants ICD5-N 462437-WCutter for TOI®IET implants IC5-N 462438-WCutter for TOI®IET implants ICT5-N 462415-WPunch, Ø 4.9 mm PUW 1 425109Punch, Ø 3.9 mm PUW 2 425110Punch, Ø 5.2 mm PU 425108Universal ratchet adapter UAW 425107Insertion tool IT 1 ATIERatchet adapter IT ITV 500854Drill extension DX 2 500704Hex-instrument HT 1.25 EO 462371Hex-instrument HTX 1.25 EO 462372Flat spanner HAS 463108Ratchet RAT 3 425052Instrument-tray (with content) S60036 2.381,80Instrument-tray (empty) 60036 315,00

LATERAL IMPLANTS

7

IMPLANTS AND SURGICAL INSTRUMENTS

a) Max. head - Ø: 4.8 mm b) Hex - Ø: 2.5 / 2.7 mm c) Enossal Ø: 4.1 / 4.8 mmd) Hex height: 0.7 mme) Polished neck: 1.8 mmf) Enossal height: 3.5 mmThe implant body is made of Grade 4 titanium.

Palatal anchorage for orthodontic appliances (intra-oral use). Epithesis anchorage in the maxillo-facial region (EO use)

Description Working depth a REF Price cat.

FBS 4.1 6 mm 900313 KFBS 4.8 6 mm 900314 K

Description enossal length a REF Price cat.

Caliper 4.1 4.2 mm 900306 MCaliper 4.8 4.2 mm 900310 M

Description Working depth a REF Price cat.

EO 3.5 SS 3.5 mm 900312 M

Description Drill - Ø REF Price cat.

DS 2 2.0 mm 425001 D

DS 2.8 2.8 mm 425005 D

DS 3.5 3.5 mm 425009 DDS 4.2 4.2 mm 425013 D

IMPLANTS

SHAPING DRILLS (FOR USE IN ORTHODONTICS FOR PALATAL ANCHORAGE ONLY, DO NOT USE FOR EO)

CALIPERS

STOP DRILL (FOR EO-APPLICATIONS: WITH BONE-LEVEL STOP)

TWIST DRILL

INDICATIONS

a6 810 mm

a

bb

a

c

d

e

f

a

SMART²® - Implants

Description enossal Ø Max. head - Ø REF Price cat.

SMART2® 4.1 4.1 mm 4.8 mm 900301 LSMART2® 4.8 4.8 mm 4.8 mm 900302 L

Smart2® implants are sand blasted and then etched in a high-temperature process.

Smart²® implants are equipped with an external hex and feature a polished transition zone.

Max. external - Ø REF Price cat.

5.5 mm 900308 M

EXPLANTATION DRILL

Description REF Price cat.

Cover screw CSTE B

SURGICAL SCREW FOR COVERED HEALING (KFO- AND EO-APPLICATIONS)

8

SURGICAL INSTRUMENTS AND TOOLS

Material REF Price cat.

Ti6Al4V, use with HTS 1.25 or HT 1.25 900309 D

Material Length Code REF Price cat.

Surgical steel 24 mm HT 1.25 EO 462371 C

Description Diameter REF Price cat.

PU 5.2 mm 425108 C

PUW 1 4.9 mm 425109 C

PUW 2 3.9 mm 425110 C

Material Length Code REF Price cat.

Surgical steel 21 mm UAW 425107 E Do not use UAW in combination with RAT2 with Heatless® bone drills. The maximum insertion torque for UAW and Heatless® bone drills is 35 Ncm. UAW may therefore be used only with TW2.

Material REF Price cat.

CoCrMo alloy, weldable. Incl. screw, screw in with HT 1.25 900307 D

HEALING SCREW AND DIRECTIONAL GUIDES (FOR EXPLANTATION DRILLS)

ABUTMENT

IMPRESSION POSTS

PUNCHES

HEX TOOL

RATSCHET ADAPTER

Material REF Price cat.TSP is clicked onto the exposed implant. Impression to be taken using alginate. 900311 A

Description Length REF Price cat.

IT 1 ATIE 22 mm IT 1 ATIE D

Description REF Price cat.

DX 2 extendes bx 19 mm 500704 D

INSERTION TOOL FOR SMART2®

DRILL EXTENSION

LATERAL IMPLANTS

9

ZSI IMPLANTS

a) Max. diameter of thread: 4.6 mmb) Endosseoous length: 35 - 55 mmc) Abutment height: 7 mmd) Max. abutment diameter: 3.9 mmf) Diameter of shaft: 2.0 mmg) Upper diameter of shaft: 2.2 mmh) Length of thread: 10 mm

ZSI: ZYGOMA - SCREWS - IMPLANTS

ZSI-Implants are placed trans-sinualy or below/inside the crista zygomatico-alveolaris, and in the alveolar crest of the maxilla. For cortical anchorage in the zygomatic bone. Depending on the anatomic situation the smooth parts of the implants are positioned below the Schneiderian mebrane or below the oral muscosa. These implants are to be used only by trained surgeons. ZSI-Implants provide a bending area below the cementing abutment. Therfore they can be aligned with other abutments in the center of the crest after the implant has been placed. An additional vertical osteotomy may be necessary (see the drawing) . This implant can be used in combination with tubero-pterygoid screw implants (BCS). The treat-ment protocol requires immediate splinting. Material: Titanium alloy, Ti6AI4V ELI.

Description enossal Ø Length REF Price cat.

Allfit ZSI 4.6 35 4.6 35 900100 F

Allfit ZSI 4.6 37.5 4.6 37.5 900101 F

Allfit ZSI 4.6 40 4.6 40 900102 F

Allfit ZSI 4.6 42.5 4.6 42.5 900103 F

Allfit ZSI 4.6 45 4.6 45 900104 F

Allfit ZSI 4.6 47.5 4.6 47.5 900105 F

Allfit ZSI 4.6 50 4.6 50 900106 F

Allfit ZSI 4.6 52.5 4.6 52.5 900107 F

Allfit ZSI 4.6 55 4.6 55 900108 F

Description REF Price cat.

Twist Drill 2.2 / 50 for Zygoma implants, SS 90021 D

Twist Drill 2.2 / 55 for Zygoma implants, SS 90023 D

Twist Drill 2.2 for handgrip to Zygoma implants, L = 100 mm 310514 F

TWIST DRILL

c

b

a

d

f

g

h

ACCESSORIES FOR ZSI

Zygomatic bone Zygomatic bone

Maxillary sinus

Zygomatic bone

ZSI-Implants may be used in a trans-sinusal or sub-mucosal manner. The abutment head is aligned with the tooth arch through bending.

Maxillary sinusMaxillary sinus

Code REF

TSPA 5 (plastic) 462030 Impression post internaly round Pack à 5 Stück

IA4/IAU (metal) 462112 Double analogue

IA4/IAU (plastic) 462111 Double analogue Pack of 5

POB 462086 Castable part Pack of 5

Price cat. B A B B

Safe anchorage in cortical bone even in patients with reduced bone height

Orbita

Craniale Maxilla

Multiple design patents: For long-term primary stability

Single piece Zygoma-screw-implants

BOI® and TOI® implants may be inserted and serviced only by qualified personnel with valid authorization by the manufacturer (pursuant to legislation on the installation, use and maintenance of medical devices). We are certified DIN EN ISO 13485, and annex II of EEC Directive 93/42 EWG (incl. amendment 2007/47). The product dimensions shown in this catalogue may be different from actual reality for technical reasons. Smart2® and TOI® are registered trademarks. Smart2® and TOI® implants are protected by patents. In case that implants would be reprocessed (cleaned, resterilized) infections could occur, because no validated procedures for reprocessing are available. In cases where our implants are used in the cranio-facial or maxillo-facial field for fixating epitheses, they must be used only by trained cranio-facial or maxillo-facial surgeons.

0029REF 6644EN_V001_02/15

CONTACT

CH Dr. Ihde Dental AGDorfplatz 11 CH - 8737 Gommiswald / SG Tel. +41 (0)55 293 23 23 Fax +41 (0)55 293 23 00 [email protected]

D Dr. Ihde Dental GmbHErfurter Str. 19 D - 85386 Eching / Munich Tel. +49 (0)89 319 761-0 Fax +49 (0)89 319 761-33 [email protected]

www.implant.com (CH) www.ihde-dental.de (DE)

Prices valid from 01.01.2014

Symbols on the packs

Production No.

Sterilized by gamma radiation

Sterilization Ethylene oxide

Single-use pro-duct

Instruction for use

Expiry date Store in a dry place

Temperature range from -5° C to 25° C

Store tightly keep closed

Do not use if packing is damaged

Do not resterilize

Manu-facturer

-5° C

25° C

Rx ONLYNon-sterile

Intended for use by dentists or surgeons only

Production date


Recommended