mkgV dc
36015 - Schio (VI)
Test report n°
- date
- date
147- request
Gate with IGEA BT motor and LIBRA MA
Refers to
24
4,975X1,150- main characteristics
Not presentSensing edge
Weight gate 200
191/05
Motor power
Width and height
2005-04-21
CERT 0147/05- registration n°
---
2005-06-22
- date of arrival
- date of tests
Alessandro CibinMatteo DazzanLaboratory Technician Laboratory Technical Manager
Page 1 of 4RDP 13.01 Rev. 4 del 2005-03-12
The reproduction of this document is only permitted in complete copy.
- model
- constructorVia Lago di Vico, 44 - 36015 Schio (VI)BFT S.p.A.
--------
BFT S.p.A.Via Lago di Vico, 44
- subject
2005-07-27
Composed of 4 pages of test report and 25 of attachment
ORGANISMO NOTIFICATOPER LA CPD N° 1600
Sede Legale:
Sede Principale:
Unità Operativa:
c/o Camera di Commercio Industria Artigianato AgricolturaP.zza Borsa, 3/B 31100 Treviso (TV)Cod. Fisc. 80009550262P. IVA 00484170261Tel. 0422/5951www.tv.camcom.it
Centro Cristallo, Via Roma 431020 Lancenigo di Villorba (TV)Tel. 0422/608858 - Fax 0422/608866Videoconferenza 0422/[email protected]
CERT Centro di Certificazione e Test di Treviso TecnologiaVia Pezza Alta, 34 31046 Rustignè di Oderzo (TV)Tel. 0422/852016 - Fax 0422/852058Videoconferenza 0422/[email protected]
33,028,0
318 %18 %
- Description of the test:
- Notes: The test was carried out on a specimen prepared and installedby the firm BFT S.p.A. via Lago di Vico 44 - 36015 Schio (VI).
The test was carried out according to the UNI EN 12445(2002)regulation Point 5 and UNI EN 13241-1(2004) regulation Point4.3.3.
Closing slow-down torque:
12
123
Test n° Dynamic force [N]Point 1
11
179
Average
7 9
20,0
16 293
17,3
Point 1 Point 2 Point3
Average
- Machines / equipment used:
- Date of test:
- Set-up of test sample:
The average forces found are within the limits defined in the UNI EN 12453(2002) reg.
Test n° Dynamic force [N]
320 326
°C
3
Point 4
Page 2 of 4
The reproduction of this document is permitted only in complete copy.
FRD.PFP 13.32 Rev. 0 del 2005-04-06
2005-06-22
Average
Measurement of force - UNI EN 12453(2002) point 5
Opening of the wing 50 mm, between the primary edge and the opposite edge
Test report n° 191/05
- Environmental conditions of test: Temperature:Humidity:
6 12
% U.R.
Point 2 Point3
356,3Test n° Static force [N]
29 22 29
Test n°
16,0
217195
197,0
302
306,3
355297 388
8
Point 5 Point 6
Final force [N]Point 1 Point 2 Point3
0
Opening of the wing 300 mm, between the primary edge and the opposite edgeThe average forces found are within the limits defined in the UNI EN 12453(2002) reg.
1
224
Test n° Static force [N]Point 4 Point 5 Point 6
211 412Average 230,7
206 3482 260 173 3821 208
196,7 380,7
1 10 21 82 20 8 2
11,3 12,03 9 5 26
13,0
Force tester Microtronics BlueForce.
Test n° Final force [N]
1 3 13 2 1 0
Average 1,0 3,3 0,7Test n° Dynamic time [s]
Point 1 Point 2 Point31 0,06 0,45 0,492 0,07 0,28 0,493 0,33 0,25 0,49
Average 0,15 0,33 0,49
Point 4 Point 5 Point 61 0 0 02 0 0 03 0 0 2
Point 4 Point 5 Point 6
Average 0,0 0,0 0,7
0,441 0,29 0,07 0,27
0,443 0,03 0,30 0,61
Slow-down speed:Opening slow-down torque:
Average 0,13 0,15
2 0,06 0,07
Test n° Dynamic time [s]
1
2
6
4
5
3
33,028,0
318 %18 %
- Description of the test:
- Notes: The test was carried out on a specimen prepared and installedby the firm BFT S.p.A. via Lago di Vico 44 - 36015 Schio (VI).
The test was carried out according to the UNI EN 12445(2002)regulation Point 5 and UNI EN 13241-1(2004) regulation Point4.3.3.
3
Static force [N]
12 9
10
12
AverageTest n°
3
Average
Force tester Microtronics BlueForce.
Test n° Final force [N]
12
The average forces found are within the limits defined in the UNI EN 12453(2002) reg.
3
Test n° Dynamic time [s]
Point 7 Point 8 Point 9
Closing slow-down torque:
Test n° Dynamic force [N]
234
13,3 12,0 5,3
172243275
219195
216,0
Measurement of force - UNI EN 12453(2002) point 5
- Set-up of test sample:
°C% U.R.
Slow-down speed:
The average forces found are within the limits defined in the UNI EN 12453(2002) reg.
9 7 6
Test n° Final force [N]Point 7 Point 8
1Point 9
2005-06-22
Opening of the wing 500 mm, between the primary edge and the opposite edge
Test report n° 191/05
- Environmental conditions of test: Temperature:Humidity:
Opening of the wing 500 mm, between the back edge and the adjacent sides
- Machines / equipment used:
- Date of test:
Page 3 of 4
The reproduction of this document is permitted only in complete copy.
FRD.PFP 13.33 Rev. 0 del 2005-04-06
3
12
Test n° Static force [N]Point 7 Point 8 Point 9
Average 230,0302
256
277,0
273
6 311 23 7201
23
Average
4 4 02 2 4 33 0 0 0
Average 2,0 2,7 1,0Test n° Dynamic time [s]
Punto 7 Punto 8 Punto 91 0,04 0,51 0,48
0,272 0,08 0,51 0,29
1
Average 0,16 0,52
Average
267351381
Point 1024
0,35
Test n°
Average
23
0,750,720,73
Point 10
Opening slow-down torque:
12
14,3
Point 10
333,0
Dynamic force [N]
3 0,36 0,54
01,0
Point 100,72
7
8
10
9
33,028,0
318 %18 %
- Description of the test:
- Notes: The test was carried out on a specimen prepared and installedby the firm BFT S.p.A. via Lago di Vico 44 - 36015 Schio (VI).
The test was carried out according to the UNI EN 12445(2002)regulation Point 5 and UNI EN 13241-1(2004) regulation Point4.3.3.
123
Average
- Machines / equipment used:
- Date of test:
Page 4 of 4
The reproduction of this document is permitted only in complete copy.
FRD.PFP 13.33 Rev. 0 del 2005-04-06
Average
1
Opening of the wing 500 mm, between the primary edge and the opposite edge
Test report n° 191/05
- Environmental conditions of test: Temperature:Humidity:
32
2005-06-22
12
0,260,460,33
AverageTest n° Dynamic time [s]
1
The average forces found are within the limits defined in the UNI EN 12453(2002) reg.
Test n° Final force [N]
3
0,2623
Average
Point 11
1
Measurement of force - UNI EN 12453(2002) point 5
- Set-up of test sample:
°C% U.R.
Slow-down speed:Opening slow-down torque:
Test n°
Closing slow-down torque:
Force tester Microtronics BlueForce.
108
7,0
Point 1103
1,3
344288,3
Point 113
Static force [N]
Point chosen by the laboratoryPoint 11
237284
Test n° Dynamic force [N]
11