46
OS7200 Trainning Schedule 1 Day 09:00 ~ 09:30 ; Introduction 09:30 ~ 12:30 ; System Oerview (Configuration, H/W description) : Mr. CJKIM 12:30 ~ 13:30 ; Lunch 13:30 ~ 17:00 ; Data module (- Network , Firewall Configuration/- DB Backup, Default DB Setting and S/W Upgrade) : Mr.SSJoe 2 Day 09:00 ~ 12:30 : Data module (- Switch, VPN and IDS /- DSMI 및 SIP ALG) : Mr.DHLee 12:30 ~ 13:30 ; Lunch 13:30 ~ 17:00 ; OSM ( WEB Based Management tools) :Mr.STNo 3 Day 09:00 ~ 12:30 : VoIP & Network cheklist : Mr.SWLee 12:30 ~ 13:30 ; Lunch 13:30 ~ 17:00 ; WLAN module : Mr.SSRue 4,5 Days CTI
Transcript

OS7200 Trainning Schedule

1 Day 09:00 ~ 09:30 ; Introduction 09:30 ~ 12:30 ; System Oerview (Configuration, H/W description) : Mr. CJKIM 12:30 ~ 13:30 ; Lunch 13:30 ~ 17:00 ; Data module (- Network , Firewall Configuration/- DB Backup,

Default DB Setting and S/W Upgrade) : Mr.SSJoe

2 Day 09:00 ~ 12:30 : Data module (- Switch, VPN and IDS /- DSMI 및 SIP ALG) : Mr.DHLee 12:30 ~ 13:30 ; Lunch 13:30 ~ 17:00 ; OSM ( WEB Based Management tools) :Mr.STNo

3 Day 09:00 ~ 12:30 : VoIP & Network cheklist : Mr.SWLee 12:30 ~ 13:30 ; Lunch 13:30 ~ 17:00 ; WLAN module : Mr.SSRue

4,5 Days CTI

OS7200 Training

SAMSUNG ElectronicsSeptember 2004

OS7200 Overview

Modular system comprising of up to 2 racks Voice,Data & wireless convergence system Fully expanded system supports up to a

maximum of 160 ports except IP-Phone and WLAN Phone 120 ports

Each Rack can support up to a maximum of 80 station ports (Keyset/SLI)

Trunk ports capacity Single rack with PRI = 122 ports - w/o PRI

= 80 ports 2 rack with PRI = 216 ports - w/o PRI =

160

OS7200 Overview

Range of new Features Router LAN Switch Security : Firewall,VPN,Packet Filtering Layer2 QoS : 802.1p/q Layer3 QoS : CBQ, RTP Priority Queuing Long Distance Ethernet : VDSL DSLAM IP UMS(VM,AA,TTS,Voice recording,E-mail) SIP Server VoIP WEB based Management Multi WLI card support Including 500Premium function

OS7200 Overview

OS7200 - Main Rack system Floor, Wall or Rack Mountable 5 universal card slots RJ45 modulor Interface dedicated MCP slot - slot 6 Supports maximum of 80 station ports

with 1 PSUs Large LCD Phone support 24port with

1PSUs 3 WLI card support

OS7200 Overview

OS7200 Expansion rack - 2 Racks Floor, Wall or Rack Mountable 10 universal card slots Slot 1 in first cabinet used for LCP card Second Rack is controlled by LCP card

installed in dedicated MCP/LCP slot - slot 6

Supports maximum of 160 station ports

E1/PRI card support in slot3 Large LCD Phone support 48port

OS7200 Overview

Memory/Software System Operating software is stored on

a 16 Megabyte Smart Media Card System boots from 512kbytes ROM and

downloads to: 32Mbytes of DRAM

Customer Database is stored in: 4 Meg of SRAM

Smart Media

• NAND Flash• Standard Data Structure• OS: DOS/FAT File system • Used to write data from Memory to Flash• 16MB SmartMedia(TM) is used for OS7200. • Dimension : 37.0(w) x 45.1(L) x 0.76(H) (mm)

Benefits Easy Program Upgrade(No EPROMs required) - Locally & Remotely Easy Back Up of Customer DataBase - Safe from the data loss in power failure Programs installed on Smart Media include: - MCP,LCP,TEPRI Pre-Install Available in your office - Useful for same category site installation

OS7200 Overview

MicroprocessorsLocation Processor Level Function

MCP Motorola MPC855T 32 bit running at 50Mhz

Primary Provides all processing for a Main rack system

LCP Motorola MC 68302 16 bit running at 16 MHz

Secondary Provides local control of Expansion rack

WIM Motorola MPC 8250 64 bit running at 300 MHz

Routing Provides Router function between the WAN and Local LAN

MGI ARM core 32bit running at 50MHz

Gateway Provides Gateway unction between Voice and Data

TEPRI Motorola MC 68302 16 bit running at 16 MHz

Digital trunk Provides Digital Trunk function

Keyset

Hiachi H8 Tertiary Provides data communication within the system

OS7200 Overview

Programming Self Configuring (w/o WIM) MCP assigns Default Numbering Plan

3 or 4 digits according to setting on MCP Card

Flexible numbering plan Programming

via keyset PC - using windows based DPAP-PCMMC 4 levels - Technician, System Administrator,

station user plus via PROG key local and remote programming via LAN

OS7200 System Capacities

Voice Switch . . Trunk/Station : Max. 216ch (PRI : 30ch) . Common Resource : MFS/R, R2CID, Miscellaneous

LAN Switch . Max. 128port

Slots . 32ch slot : 4 slot ( Main rack 3slot/Expansion rack 1slot) . 16ch slot : 6 slot . WIM card : Slot1 per each Rack . LIM card : slot2-5 per each RackSystem IO Serial Communication Port ( Async.) ) . Main : 1 Ports ( MCP ) . Expansion : 1 Ports ( LCP ) LAN . Speed : 10/100 MBPS . Physical Connection : RJ-45 ( 1 Port ) . Built in LAN Board

OS7200 System Capacities

Common Resources .Main . Shelf #1 : DTMF receiver 4Ch, DTMF sender 32Ch, Conference 5 party x 6 groups

.Optional Daughter boards . MFM : DTMF receiver 12ch . RCM : R2 sender 30ch, R2 receiver 8ch. Caller ID receiver 14ch. . RCM2 : Caller ID Sender . MIS : External music 2port, Paging 1port, Loud bell 1port Common bell 1port, Dry contact 2port . Installed maximum - 1EA/MCP

Miscellaneous Functions . Basic : Internal music 1 Port ( MCP ) . Expansion : MIS x 1 ( 1EA/MCP )

SolutionSolution

AdminAdmin

WLAN AP

SMESME

PC ConsoleSmart CallContact CenterVideo Conferencing

Web BrowserSystem MasterPhone ManagerFast Ethernet

Mail ServerInstant Messaging SIP ServerVoIP-UMS LiteVoIP-UMS Pro

FeatureFeatureFast Ethernet

Fast EthernetBranch Office

VPN Tunnel

VoWLAN Phone

WLAN IP Phone LDE Modem

xDSL, Metro Ethernet, VoIP, TDM, etc.

IP-VDSL

Home Working

Operator Network

IP Phones

Digital Phones

Highly Integrated “All-in-one” converged solutionfor total business communication

OS7200 System

OS7200 Hardware

OS7200 Rack

Common Rack for use as main rack or expansion rack

FAN reduce a heating problem Slots 1-5 universal slots

Main rack Slots 3-5 assigned 32 time slots Expansion rack Slots 3 assigned 32 time slots Other slot assigned 16 time slots

Slot 0 dedicated for Processor cards (MCP or LCP)

AC power switches DC (battery back up)

OS7200 Rack Configuration

Front View of the Expansion Rack

Front View of the Main Rack

Slot 0Slot 1 Slot 2

Slot 3Slot 4 Slot 5

Slot 0Slot 1 Slot 2

Slot 3Slot 4 Slot 5

Cabinet Slot Mountable Boards

Main Rack(OfficeServ- Access)

Slot 0 MCP only

Slot 1 All boards except for MCP, LCP, TEPRI, and LIM

Slot 2 All boards except for MCP, LCP, TEPRI, and WIM

Slot 3,4,5 All boards except for MCP, LCP, and WIM

ExpansionRack(OfficeServ- Expansion)

Slot 0 LCP only

Slot 1 All boards except for MCP, LCP, TEPRI, and LIM.

Slot 2

Slot 3 All boards except for MCP, LCP, and WIM

Slot 4 All boards except for MCP, LCP, TEPRI, and WIM

Slot 5

Power Supplies

1 PSUs can be installed in each rack PSU must be installed in backplane PSU provides the several voltage supply to the rack PSU supports 80 station ports or Station Equipment

Power Units (SEPU) No redundancy Power to is controlled by Thermal sensor If the FAN module stoped, System halt after 24 hours.

Power Supplies

Item Current PSU

-48V 2.2A +5V 8A -5V 1A 3.3V 10A 12V 0.4A

Battery Charger 0.4A Max. consumption 200W

PSU Comparison

OS7200 -48V Card Power Requirements

Card Type Ports/SEPUs 16DLI, 8DLI, 8HYB 24(Large LCD Phone) 16DLI, 16SLI, 8HYB, 8DLI 16 4WLI 12 8SLI, BRI S0 8 PRI, TEPRI, 8 Trunk, WIM, LIM, 4DSL

0 (use 5V or 3.3Volts only)

Power Supply Limitations

48V power will be available 106 SEPUs Example Main rack with a PSU installed. The following interface cards

are installed 16DLI (slot1), 16DLI card (slot2), 16DLI card (slot3), 4WLI card (slot4), TEPRI Card (slot5)

Total power units of installed cards: 32+32+32+12+0 = 108. - Slot1 used Large LCD Phone 8 port and 2line LCD Phone 8

port. - Slot2 used Large LCD Phone 8 port and 2line LCD Phone 8

port. - Slot3 used Large LCD Phone 8 port and 2line LCD Phone 8

port. - Slot4 used WBS24 Combo 4 portsto power the keysets

connected to 16DLI cards. If 16DLI over 8port Large LCD Phone, Power of 16DLI card

stop.

OS7200 Processor Cards

Main Control Processor - MCP

Installed in slot 0 of the main rack Has the following features:

256 time slot switch matrix Smart Media Card slot 3 Daughter board positions Memory Backup Switch 8 Position Dip Switch Reset button 4 Status LEDS Internal MOH source 1 SIO data rate adaptors 3 x RJ45 STP connected to LCP card

MFM

RCM

MIS

Main Control Processor - MCP

S3

S2

CHARGE

Off

Main Control Processor - MCP

DIP SWITCH USE on the OS7200 MCP

ON (left) OFF (right)

4 Digit Trunk Numbers SW8 3 Digit Trunk Numbers

4 Digit Station Groups SW7 3 Digit Station Groups

4 Digit Station Numbers SW6 3 Digit Station Numbers

Automatic Program Download on power up

SW5

Country Select SW4 Country Select

Country Select SW3 Country Select

Country Select SW2 Country Select

Country Select SW 1 Country Select

4 3 2 1 Country

OFF OFF OFF OFF Korea

OFF OFF OFF ON USA

OFF OFF ON OFF UK

OFF OFF ON ON Italy

OFF ON OFF OFF Australia

OFF ON OFF ON New Zealand

OFF ON ON OFF Holland

OFF ON ON ON Denmark

Ports & LEDs Function Description

LINK1~LINK3 Ports that connect the MCP with the LCP.

MISC1~MISC2 Ports that connect external music sources, paging device, loud bell, common bell, or door bell.

SmartMedia Port for installing the NAND-type flash memory.

LAN Port for establishing the 10Base-T/100Base-Tx Ethernet connection.

SIO UART port(for tests).

RST Button for resetting the MCP board.

RUN LED This LED indicates the status of the MCP. ( - On : Booting./- Blink : The program is operating)

LAN LED - On : MCP is connected LAN.- Blink : MCP is transmitting or receiving Data through LAN port.

SM LED - On : The SmartMedia is installed, however is not accessed.- Blink : The SmartMedia is installed and is being accessed.

LCP LED This LED indicates the status of signaling message processing. - On : Messages are being sent/received to/from the LCP.

Main Control Processor - MCP

Local Control Processor - LCP

Installed in Slot 0 of Expansion rack Has the following features:

2 status LEDs for LCP operation 3 x RJ45 STP Connector for Connection

to MCP and LCP card Supplied with LINK cable

Local Control Processor - LCP

Ports & LEDs Function

LINK1~LINK3 Ports that connect the MCP with the LCP.

SIO UART port(for tests).

RST Button for resetting the LCP board.

RUN LED This LED indicates the status of the LCP.- Off : Power is not connected.- On : Booting.- Blink : The RAM program is operating.

MCP LED This LED indicates the status of signaling message processing.

- Off : There’s no message exchange between MCP and LCP.- On : Messages are being sent/received to/from the MCP.

Local Control Processor - LCP

LINK1 LINK3

LINK2

Link Cable

Connecting MCP Board to LCP Board

Processor Daughter Boards

Multi- Frequency Module - MFM

Installs in any daughter board position of the MCP cards. - maximum of 1 per processor card

Provides 12 DSPs for DTMF and Tone Detection SLT ports or DISA trunks

Multi- Frequency Module - MFM

P1

U7 U4U5

P2

U2

U1

U6

U3

R2/CID Module - RCM

Installs into any of the MCP Cards Consists of the following:

14 CID receivers for CID trunks 30 R2 MFC senders and 8 receivers 8CID and 4R2 MFC

R2/CID Module - RCM

P2

U3

U4

P1

U1

U8

U5

U9

U2

Miscellaneous Function Module - MIS Installs in the following positions:

MCP - Main Rack systems only 2 x RJ-45 sockets Consists of the following:

2 External Music sources 1 External paging audio output 1 loud bell relay audio output 1 common bell relay contact closure 2 software assigned relay contact closures

Miscellaneous Function Module - MIS

Dry contact #1(For common bell)

Dry contact #3(For external page)

External Page Equipment

Additional Page Equipment

MISC 1

MISC 2

Dry contact #2(For external page)

Connecting External/Additional Page Equipment

MOH/BGM source of a user

MOH/BGM source of a userMISC 1

MISC 2

Miscellaneous Function Module - MIS

Trunk Cards

8TRK card

Trunk - 8 loop start trunks 8 Trunk Caller ID path support Performs Polarity Reverse

Detection(PRD) - option Performs Metering Pulse

Detection(MPD) - option

Ports & LEDs

Function Description

P1~P8 Trunk ports.

P1~P8 LED These LEDs indicate the status of the ports.- Off : The trunk line is not being used.- On : The trunk line is being used.- Blink : The ring is being connected.

8TRK card

P1-P8 Port(RJ-45)(RJ-45)

PinNo. 1 2 3 4 5 6 7 8

Function - - - C.O. TIP C.O. RING

- - -

8TRK card

Connecting Common C.O. Lines

TEPRI Card

This card may be configured for PRI or E1 operation. Supports Q-signalling in OS7200 system Must be installed in slots 3-5 in main rack

maximum of 4 per system Do not install this card with the power ON Supports the following features

8 Status LEDs 1 x RJ-45 Sockets for PRI or E1 1 x RJ45 connector to allow upload of TEPRI

software directly to the Card - generally not required

Reset Button - to reset the card 8 position switch to set card operation

TEPRI Card

TEPRI CardTEPRI CARD DIP SWITCH Settings

Switch No. ON OFF Description

1 T1 E1 Selects whether T1 or E1

2 PRI T1 or E1 Selects whether PRI or not

3 Not used

4 NETWORK USER Select Network or User

5 Not used

6 Not used

7 Not used

8 Always ON This switch must always be ON as it is used for Card ID

Switch Settings for PRI/E1 operation

Switch No. PRI Operation E1 Operation 1 OFF OFF 2 ON OFF 3 OFF OFF 4 OFF ON for Master OFF for

Slave (Note) 5 OFF OFF 6 OFF OFF 7 OFF OFF 8 ON ON

Note: When networking OS7200 systems one system must be designated the master (NETWORK) and the other the slave(USER)

TEPRI Card

T1/E1/PRI Port(RJ-45)

Pin No. 1 2 3 4 5 6 7 8

T1 Function Rx+ Rx- - Tx+ Tx- - - -

E1/PRI Function - - - Tx+ Tx- - Rx+ Rx-

Ports & LEDs Function Description

T1/E1/PRI Ports that connect the T1/E1/PRI cable.

SIO UART port(for tests).

RST Button for resetting the TEPRI board.

SYNC LED - On : Clocks are not synchronized when they inter-work with the counterpart station.

- Off : Clocks are synchronized when they inter-work with the counterpart station.

LOS LED - On : Signals have been lost.- Off : Signals have not been lost.

AIS LED - On : The remote alarm has been generated.- Off : The remote alarm has not been generated.

L2 LED This LED indicates the operation status of Layer 2- On : The PRI Layer2 is operating properly. - Off : The PRI Layer2 is operating abnormally.

IPC LED This LED indicates that this board is inter-working with the higher-level module.- On : The board is inter-working with the MCP/LCP.- Off : The board is not inter-working with the MCP/LCP.

CLK LED This LED indicates whether this board is a master or slave.- On : The board has received the synchronization clock from the counterpart station.- Off : The board has sent the synchronization clock to the counterpart station

TP1 LED This LED indicates whether the T1 is established.- This LED turns on once the T1 is established.

TP2 LED This LED indicates whether the PRI is connected. - This LED turns on once the PRI is connected

TEPRI Card

IP Telephony Module - MGI

Provides 0 VoIP channels expandable to 16 using MGI2D

daughter cards Each MGI2D card support 4ch voice/fax H.323/ SIP G.711/G.723.1/G.729 voice compression protocols

Installed in any universal card slot with power OFF Supports the following features

8 Status LEDs RJ-45 10/100 base-T LAN connection 1 x RJ45 connector to allow upload of TEPRI

software directly to the Card - generally not required

Reset Button - to reset the card

MGI Card

Option4

MGI2D

Option3

MGI2D

Option2

MGI2D

Option1

MGI2D

OFF : No memory backup

ON : Available for memory backup (base default value)


Recommended