Our commitment is your safe future Electrical Installations from A to Z Price List w.e.f. 1st May, 2017
Transcript
Page 1: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Our commitment is your safe futureElectrical Installations from A to Z

Price List w.e.f. 1st May, 2017

Page 2: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

2 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Experience active communicationOur Switchgear can now speak and obey your commands

sForIndustryProducts

Face the reality of remote monitoring and controlling of our DI products. Yes, our MCBs and RCDs can now speak and obey your commands!

The Siemens solution for remote communication capability facilitates the following applications, which are inevitable in today’s smart infrastructures like Data centers, Commercial Buildings, Energy Management Systems etc.

The solution covers:

• RemoteControlling(ON/OFF)ofFinalDistributioncomponents(likeMCBs/RCDs)

• ON/OFFStatusmonitoringofallmodulesforFinal distribution products

• FaultTripStatusofcomponentsatFinalDistribution level

www.siemens.co.in

Page 3: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 3

Index

Sr. No.

Items Pg. No.

1 Betagard Miniature Circuit Breakers

5SL6, 7.5kA with C characteristics 5

5SL6, 7.5kA with B characteristics 6

5SL4, 10kA with C characteristics 7

5SP4, 10kA with C and D characteristics 9

2 Betagard Circuit Breakers

5SY7, 15kA with D characteristics 8

5SY5, 10kA DC Circuit Breakers 10

3 Betagard Isolators

5TL1 Isolators 10

4 Betagard Residual Current Circuit Breakers

5SM3 RCCB - Type AC 12

5SM3 RCCB - Type A 12-13

5SM3 RCCB - Type B 14

5 Betagard Residual Current Breaker Operators

5SU1 RCBO, 10kA, Type AC with C and D characteristics

15

5SU1 RCBO, 10kA, Type A with C and D characteristics

16

6 Betagard Accessories 17

7 Arc Fault Detection Devices (AFDD) 18-19

8 Betagard Distribution Boards

8GB32SPN,TPN&PhaseSegregatedDBs 21-23

Betagard MB DB 23

8GB0SPN&TPNDBs 24

8GB31 - Flexi, Bus, Bus Plus, Multi, CO DBs 25

IndustrialPlug&SocketDBs,SimboxWPDBs 26

Accessories for Betagard DBs 27

9 Betagard Modular Devices

Surge Protection Devices 28

Changeoverswitches,Instacontactor&Measuring Switches

29

Voltagerelays,DigitalAmmeters& Voltmeters, Indicators and Fuse Monitors

30

Time Switches 31

10 Sentron MCCBs - 3VT1,2,3 and RAJA Starters ordering info

32

11 Switch Disconnector Fuses - 3KL and Fuses - 3NA/3NW ordering info

33

12 Multi channel current measuring system 34

13 Customer Care 35

Page 4: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

4 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Betagard 5SL MCBs – Inspiring Safety

Siemens has always endeavoured to introduce innovative products worldwide.

Betagard 5SL MCBs offer numerous features -

MCB with patented unique SLR(SlideLatch-Release)featurefortoolfreeremovalfromDINrail.Italsoallowsindividual MCB to be removed from bus bar mounted assembly without disturbing other devices

With

SLRIS/IEC 60898 - 1

BIS approval for ISI marking as per latest IS/IEC60898-1:2002forassuredqualityandprotection

Highly effective terminal covers for protection against accidental electrical contact

Unique design of square terminals of 35 Sq. mm

UniqueterminationmechanismenablesfirmmountingofBus bar together with wire; and provides front access to wires for safe installation

Side mounting accessories like auxiliary switches, fault signaling contacts and lever locking device available for special applications

• MCBwithpatenteduniqueSLRfeature

• ISIandCEmarking

• Uniquesquareterminaldesign

• Terminalcoversforextraproduction

• RoHScompliant

• Accessoriesforspecialapplications

• Verylowwattloss

• 20,000operationsonratedload

Page 5: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 5

7500ARated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

1P,240/415VAC 0.5123468

101316202532405063

1 5SL61057RC 5SL61017RC 5SL61027RC 5SL61037RC 5SL61047RC 5SL61067RC 5SL61087RC 5SL61107RC 5SL61137RC 5SL61167RC 5SL61207RC 5SL61257RC 5SL61327RC 5SL61407RC 5SL61507RC 5SL61637RC

358.-358.-358.-358.-358.-221.-221.-221.-221.-221.-221.-221.-221.-483.-562.-562.-

1/121/121/121/121/121/121/121/121/121/121/121/121/121/121/121/12

2P, 415V AC 0.5123468

101316202532405063

2 5SL62057RC 5SL62017RC5SL62027RC5SL62037RC5SL62047RC5SL62067RC5SL62087RC5SL62107RC5SL62137RC5SL62167RC5SL62207RC5SL62257RC5SL62327RC5SL62407RC5SL62507RC5SL62637RC

948.-948.-948.-948.-948.-710.-710.-710.-710.-710.-710.-710.-710.-978.-

1157.-1157.-

1/61/61/61/61/61/61/61/61/61/61/61/61/61/61/61/6

3P, 415V AC 0.51246

1016202532405063

3 5SL63057RC5SL63017RC5SL63027RC5SL63047RC5SL63067RC5SL63107RC5SL63167RC5SL63207RC5SL63257RC5SL63327RC5SL63407RC5SL63507RC5SL63637RC

1330.-1330.-1330.-1330.-1055.-1055.-1055.-1055.-1055.-1055.-1478.-1651.-1651.-

1/41/41/41/41/41/41/41/41/41/41/41/41/4

4P, 415V AC 0.51246

1016202532405063

4 5SL64057RC5SL64017RC5SL64027RC5SL64047RC5SL64067RC5SL64107RC5SL64167RC5SL64207RC5SL64257RC5SL64327RC5SL64407RC5SL64507RC5SL64637RC

1836.-1836.-1836.-1836.-1460.-1460.-1460.-1460.-1460.-1460.-1903.-2184.-2184.-

1/31/31/31/31/31/31/31/31/31/31/31/31/3

Betagard 5SL Miniature Circuit BreakersC Characteristics

Note:* MRP - Maximum Retail Price#1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

• Standards:IS/IEC60898-1:2002• Voltage:Un240/415V,50…60Hzcanbeusedinsystemsupto60VDCfor1Pand

110V DC for 2P - Suitable for Telecom Applications.• WithISImarking:CM/LNo.2255548

IS/IEC 60898 - 1

Page 6: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

6 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

7500ARated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

1P,240/415VAC 610162025324050 63

1 5SL61066RC5SL61106RC5SL61166RC5SL61206RC5SL61256RC5SL61326RC5SL61406RC5SL61506RC5SL61636RC

208.-208.-208.-208.-208.-208.-481.-541.-541.-

1/121/121/121/121/121/121/121/121/12

2P, 415V AC 61016202532405063

2 5SL62066RC5SL62106RC5SL62166RC5SL62206RC5SL62256RC5SL62326RC5SL62406RC5SL62506RC5SL62636RC

693.-693.-693.-693.-693.-693.-978.-

1149.-1149.-

1/61/61/61/61/61/61/61/61/6

3P, 415V AC 61016202532405063

3 5SL63066RC5SL63106RC5SL63166RC5SL63206RC5SL63256RC5SL63326RC5SL63406RC5SL63506RC5SL63636RC

1055.-1055.-1055.-1055.-1055.-1055.-1458.-1635.-1635.-

1/41/41/41/41/41/41/41/41/4

4P, 415V AC 61016202532405063

4 5SL64066RC5SL64106RC5SL64166RC5SL64206RC5SL64256RC5SL64326RC5SL64406RC5SL64506RC5SL64636RC

1452.-1452.-1452.-1452.-1452.-1452.-1811.-2177.-2177.-

1/31/31/31/31/31/31/31/31/3

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Betagard 5SL Miniature Circuit BreakersB Characteristics

• Standards:IS/IEC60898-1:2002• Voltage:Un240/415V,50…60Hzcanbeusedinsystemsupto60VDCfor1Pand

110V DC for 2P (Suitable for Telecom applications)• WithISImarking:CM/LNo.2255548

IS/IEC 60898 - 1

Page 7: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

10000ARated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

1P,240/415VAC 0.523468

101316202532405063

1 5SL41057RC5SL41027RC5SL41037RC5SL41047RC5SL41067RC5SL41087RC5SL41107RC5SL41137RC5SL41167RC5SL41207RC5SL41257RC5SL41327RC5SL41407RC5SL41507RC5SL41637RC

426.-426.-426.-426.-277.-277.-277.-277.-277.-277.-277.-277.-603.-603.-603.-

1/121/121/121/121/121/121/121/121/121/121/121/121/121/121/12

2P, 415V AC 0.523468

101316202532405063

2 5SL42057RC5SL42027RC5SL42037RC5SL42047RC5SL42067RC5SL42087RC5SL42107RC5SL42137RC5SL42167RC5SL42207RC5SL42257RC5SL42327RC5SL42407RC5SL42507RC5SL42637RC

1134.-1134.-1134.-1134.-

811.-811.-811.-811.-811.-811.-811.-811.-

1310.-1310.-1310.-

1/61/61/61/61/61/61/61/61/61/61/61/61/61/61/6

3P, 415V AC 0.523468

101316202532405063

3 5SL43057RC5SL43027RC5SL43037RC5SL43047RC5SL43067RC5SL43087RC5SL43107RC5SL43137RC5SL43167RC5SL43207RC5SL43257RC5SL43327RC5SL43407RC5SL43507RC5SL43637RC

1830.-1830.-1830.-1830.-1364.-1364.-1364.-1364.-1364.-1364.-1364.-1364.-2125.-2125.-2125.-

1/41/41/41/41/41/41/41/41/41/41/41/41/41/41/4

4P, 415V AC 0.523468

101316202532405063

4 5SL44057RC5SL44027RC5SL44037RC5SL44047RC5SL44067RC5SL44087RC5SL44107RC5SL44137RC5SL44167RC5SL44207RC5SL44257RC5SL44327RC5SL44407RC5SL44507RC5SL44637RC

2302.-2302.-2302.-2302.-1889.-1889.-1889.-1889.-1889.-1889.-1889.-1889.-2577.-2577.-2577.-

1/31/31/31/31/31/31/31/31/31/31/31/31/31/31/3

Betagard Miniature Circuit Breakers 5SL4, 10kA with C characteristics

• Standards:IS/IEC60898-1:2002• Voltage:Un240/415V,50…60Hzcanbeusedinsystemsupto60VDCfor1Pand

110V DC for 2P (Suitable for Telecom applications)• Breakingcapacity:10kAasperIS/IEC60898-1:2002 • WithISImarking:CM/LNo.2255548

IS/IEC 60898 - 1

Page 8: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

8 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Betagard Circuit Breakers5SY7, 15kA with D Characteristics

15000ARated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

1P,230/400VAC 0.5123468101316202532405063

1 5SY71058CC5SY71018CC5SY71028CC5SY71038CC5SY71048CC5SY71068CC5SY71088CC5SY71108CC5SY71138CC5SY71168CC5SY71208CC5SY71258CC5SY71328CC5SY71408CC5SY71508CC5SY71638CC

457.-457.-457.-457.-457.-395.-395.-395.-395.-395.-395.-395.-395.-752.-762.-762.-

1/121/121/121/121/121/121/121/121/121/121/121/121/121/121/121/12

2P, 400V AC 0.5123468101316202532405063

2 5SY72058CC5SY72018CC5SY72028CC5SY72038CC5SY72048CC5SY72068CC5SY72088CC5SY72108CC5SY72138CC5SY72168CC5SY72208CC5SY72258CC5SY72328CC5SY72408CC5SY72508CC5SY72638CC

1241.-1241.-1241.-1241.-1241.-

946.-946.-946.-946.-946.-946.-946.-946.-

1636.-1636.-1636.-

1/61/61/61/61/61/61/61/61/61/61/61/61/61/61/61/6

3P, 400V AC 0.5123468101316202532405063

3 5SY73058CC5SY73018CC5SY73028CC5SY73038CC5SY73048CC5SY73068CC5SY73088CC5SY73108CC5SY73138CC5SY73168CC5SY73208CC5SY73258CC5SY73328CC5SY73408CC5SY73508CC5SY73638CC

1897.-1897.-1897.-1897.-1897.-1503.-1503.-1503.-1503.-1503.-1503.-1503.-1503.-2548.-2548.-2548.-

1/41/41/41/41/41/41/41/41/41/41/41/41/41/41/41/4

4P, 400V AC 0.5123468101316202532405063

4 5SY74058CC5SY74018CC5SY74028CC5SY74038CC5SY74048CC5SY74068CC5SY74088CC5SY74108CC5SY74138CC5SY74168CC5SY74208CC5SY74258CC5SY74328CC5SY74408CC5SY74508CC5SY74638CC

2632.-2632.-2427.-2427.-2427.-1987.-1987.-1987.-1987.-1987.-1987.-1987.-1987.-3200.-3200.-3200.-

1/31/31/31/31/31/31/31/31/31/31/31/31/31/31/31/3

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

• Standards:IEC/EN60947-2• Voltage:Un230/400V,50…60Hzcanbeusedinsystemsupto60VDCfor1Pand

110V DC for 2P• Breakingcapacity:15kAasperIEC/EN60947-2

Page 9: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd.ElectricalInstallationMRPEff.01-05-2017 9

C characteristic

10000ARated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

1-pole 80100125

1.5 5SP41807RC5SP41917RC5SP41927RC

2621.-2763.-3134.-

1/101/101/10

2-pole 80100125

3 5SP42807RC5SP42917RC5SP42927RC

5149.-5427.-6143.-

1/51/51/5

3-pole 80100125

4.5 5SP43807RC5SP43917RC5SP43927RC

8037.-8245.-9446.-

111

4-pole 80100125

6 5SP44807RC5SP44917RC5SP44927RC

11521.-11853.-13497.-

111

D characteristic

1-pole 80100

1.5 5SP41808RC5SP41918RC

2883.-3025.-

1/101/10

2-pole 80100

3 5SP42808RC5SP42918RC

5793.-6148.-

1/51/5

3-pole 80100

4.5 5SP43808RC5SP43918RC

8927.-9009.-

11

4-pole 80100

6 5SP44808RC5SP44918RC

12553.-12864.-

11

Betagard Miniature Circuit Breakers 5SP4, 10kA MCBs with C/D characteristics

• Standards:IS/IEC60898-1:2002• Voltage:Un240/415V,50…60Hzcanbeusedinsystemsupto60VDCfor1Pand

110V DC for 2P• Breakingcapacity:10kAasperIS/IEC60898-1:2002 • WithISImarking:CM/LNo.2255548

Note:* MRP - Maximum Retail Price #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

IS/IEC 60898 - 1

Page 10: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

10 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Rated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

2-pole 32406380

100125

2 5TL123205TL124005TL126305TL128005TL129105TL12920

520.-535.-705.-925.-

1180.-1225.-

1/11/11/11/11/11/1

3-pole 32406380

100125

3 5TL133205TL134005TL136305TL138005TL139105TL13920

865.-1005.-1115.-1355.-1425.-1540.-

1/11/11/11/11/11/1

4-pole 32406380

100125

4 5TL143205TL144005TL146305TL148005TL149105TL14920

990.-1175.-1330.-1605.-1930.-2095.-

1/11/11/11/11/11/1

Betagard Isolators

• Standard:IS/IEC60947-3• Voltage:440VAC

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Betagard Circuit Breakers5SY5, 10kA DC with C Characteristics

10000ARated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

1P, 220V DC 0.5123468101316202532405063

1 5SY51057CC5SY51017CC5SY51027CC5SY51037CC5SY51047CC5SY51067CC5SY51087CC5SY51107CC5SY51137CC5SY51167CC5SY51207CC5SY51257CC5SY51327CC5SY51407CC5SY51507CC5SY51637CC

668.-668.-723.-723.-723.-612.-612.-612.-612.-612.-612.-612.-612.-919.-919.-919.-

1/121/121/121/121/121/121/121/121/121/121/121/121/121/121/121/12

2P, 440V DC 0.5123468101316202532405063

2 5SY52057CC5SY52017CC5SY52027CC5SY52037CC5SY52047CC5SY52067CC5SY52087CC5SY52107CC5SY52137CC5SY52167CC5SY52207CC5SY52257CC5SY52327CC5SY52407CC5SY52507CC5SY52637CC

1458.-1458.-1458.-1458.-1458.-1280.-1280.-1280.-1280.-1280.-1280.-1280.-1280.-1887.-1887.-1887.-

1/61/61/61/61/61/61/61/61/61/61/61/61/61/61/61/6

• Standards:IS/IEC60947-2• Voltage:220VDC/1P&440VDC/2P• Breakingcapacity:10kAasperIS/IEC60947-2

• AlsoavailableDCCircuitBreakersforSolarapplications-contactSiemenssalesofficeforfurtherdetails.

Page 11: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 11

• Instantprotectionagainstelectricalshocksandfires.

• SiemensRCDstripsnearlytentimesfasterthanIECrequirement.

• Highlyreliableduetocurrentoperatedmechanism

• ISImarkforassuredqualityandprotection

• Testedformorethan10000electricalandmechanicaloperations

• Snaponfitto35mmDINrailsandcansustainhighvibrations

• Ruggeddesigntosustain10kAfaultcurrent

Whenitsaboutlife-There is no compromiseBetagard range of RCCBs and RCBOsWith added intelligence for accurate protection

www.siemens.co.in

Page 12: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

12 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Betagard Residual Current Circuit Breakers 5SM3

Type AC, applicable in networks for AC residual currents

Rated residual current I ∆n (mA)

Rated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

2 Pole 30100300

30100300

252525404040

2 5SM33120RC5SM34120RC5SM36120RC5SM33140RC5SM34140RC5SM36140RC

3140.-3275.-3290.-3675.-3840.-3870.-

111111

30100300

30100300

636363808080

2.5 5SM33160RC5SM34160RC5SM36160RC5SM33170RC5SM34170RC5SM36170RC

4915.-4955.-5120.-7395.-7680.-7680.-

111111

30100300

30100300

100100100125125125

2 5SM33180KK5SM34180KK5SM36180KK5SM33150KK5SM34150KK5SM36150KK

15460.-13605.-13610.-19990.-17600.-17605.-

111111

4 Pole 30100300

30100300

30100300

30100300

30100300

30100300500

252525404040636363808080

100100100125125125125

4 5SM33420RC5SM34420RC5SM36420RC5SM33440RC5SM34440RC5SM36440RC5SM33460RC5SM34460RC5SM36460RC5SM33470RC5SM34470RC5SM36470RC5SM33480RC5SM34480RC5SM36480RC5SM33450RC5SM34450RC5SM36450RC5SM37450RC

4200.-4360.-4390.-4255.-4415.-4455.-4955.-5150.-5190.-6865.-6240.-6260.-

36000.-31945.-30275.-36000.-31945.-30275.-34865.-

111111111111111111

Type A, applicable in networks with AC and/or pulsating DC residual currents

2 Pole 30100300

30100300

252525404040

2 5SM33126RC5SM34126RC5SM36126RC5SM33146RC5SM34146RC5SM36146RC

4820.-5675.-5675.-5470.-5700.-5700.-

111111

30100300

30100300

636363808080

2.5 5SM33166RC5SM34166RC5SM36166RC5SM33176RC5SM34176RC5SM36176RC

7955.-8175.-7785.-8550.-9205.-8760.-

111111

30100300

30100300

100100100125125125

2 5SM33186KK5SM34186KK5SM36186KK5SM33156KK5SM34156KK5SM36156KK

24040.-24040.-24040.-33785.-31650.-31650.-

111111

• Standards:IS12640,Part1:2008/IEC61008-1:1996• Voltage:240/415Vac,50…60Hz• WithISImarking:CM/LNo.7676092

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Page 13: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 13

Betagard Residual Current Circuit Breakers 5SM3

Type A, applicable in networks with AC and/or pulsating DC residual currents

Rated residual current I ∆n (mA)

Rated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

4 Pole 30100300

30100300

30100300

30100300

30100300

30100300500

252525404040636363808080

100100100125125125125

4 5SM33426RC5SM34426RC5SM36426RC5SM33446RC5SM34446RC5SM36446RC5SM33466RC5SM34466RC5SM36466RC5SM33476RC5SM34476RC5SM36476RC5SM33486RC5SM34486RC5SM36486RC5SM33456RC5SM34456RC5SM36456RC5SM37456RC

5725.-7055.-7055.-6310.-7055.-7055.-7210.-7165.-7165.-8665.-7700.-7700.-

32995.-31805.-32320.-32995.-31805.-35255.-36330.-

1111111111111111111

Super Resistant K

2 Pole 3030

2540

2 5SM33126RC015SM33146RC01

10630.-10665.-

11

30300

6363

2.5 5SM33166RC015SM36166RC01

15465.-15385.-

11

4 Pole 3030

30030

300300

254040636380

4 5SM33426RC015SM33446RC015SM36446RC015SM33466RC015SM36466RC015SM36476RC01

14335.-13140.-12910.-13140.-12910.-13950.-

111111

Selective S

2 Pole 300 40 2 5SM36148RC 12210.- 1

100300300

636380

2.5 5SM34168RC5SM36168RC5SM36178RC

12590.-10590.-11095.-

111

4 Pole 100300100300300500

40406363

125125

4 5SM34448RC5SM36448RC5SM34468RC5SM36468RC5SM36458RC5SM37458RC

10435.-10675.-10800.-10675.-37610.-39205.-

111111

• Standards:IS12640,Part1:2008/IEC61008-1:1996• Voltage:240/415Vac,50…60Hz• WithISImarking:CM/LNo.7676092

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

RCCB suitability for various distribution networks.

Betagard RCCBs can be used in all 3 distribution network types viz.TN,TT&anITnetworksystem.4poleRCCBscanalsobeusedin3 pole supply networks by adhering to installation guidelines. In this case, connection must be at terminals 1, 3 and 5 and 2, 4 and 6.

The function of the test equipment is only ensured if a jumper is fittedbetweenterminals3andN.

Page 14: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

14 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Betagard Residual Current Circuit Breakers 5SM3

Types of Residual Current Circuit Breakers (RCCBs)

Type B, applicable in networks with AC, pulsating DC and pure DC residual currents

Rated residual current I ∆n (mA)

Rated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Super Resistant K

4 Pole 30300

30300

30300500

30300500

25254040636363808080

5SM33424RC5SM36424RC5SM33444RC5SM36444RC5SM33464RC5SM36464RC5SM37464RC5SM33474RC5SM36474RC5SM37474RC

37005.-39245.-37005.-39190.-39405.-39405.-43875.-37005.-39405.-43875.-

1111111111

Selective S

4 Pole 300500300500

63638080

4 5SM36465RC5SM37465RC5SM36475RC5SM37475RC

39280.-44550.-39280.-44550.-

1111

• Standards:IS12640,Part1:2008/IEC61008-1:1996• Voltage:240/415Vac,50…60Hz• WithISImarking:CM/LNo.7676092

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

TypeAC:

Residual current protective devices of type AC are suitable only for detecting sinusoidal AC residual current.

TypeA:

In addition to sinusoidal AC residual currents, residual current protective devices of type A also measure pulsating DC residual currents.

This device type is the most commonly used pulse current-sensitive residual current operated circuit-breaker. It also covers the residual current waveforms which can occur in power supply units(e.g.ECG,washingmachines)inthecaseofsingle-phaseloads with electronic components.

TypeB:

In addition to detecting residual current waveforms of type A, residual current protective devices of type B are used to measure smooth DC residual currents.

Possible residual current wave shapes and suitable residual current protective devices

Page 15: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 15

Betagard Residual Current Breaker Operators 5SU1, 10kA

Type AC with C characteristic

Rated residual current I ∆n (mA)

Rated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

240Vac;50…60Hz;2pole

30 324063

4 5SU13241RC325SU13241RC405SU13241RC63

4485.-5225.-6080.-

111

100 324063

5SU14241RC325SU14241RC405SU14241RC63

4950.-5560.-6480.-

111

300 324063

5SU16241RC325SU16241RC405SU16241RC63

5005.-5610.-6480.-

111

415Vac;50…60Hz;4pole

30 324063

7 5SU13441RC325SU13441RC405SU13441RC63

5990.-6095.-7235.-

111

100 324063

5SU14441RC325SU14441RC405SU14441RC63

6060.-6180.-7105.-

111

300 324063

5SU16441RC325SU16441RC405SU16441RC63

6105.-6230.-7170.-

111

Type AC with D characteristic

240Vac;50…60Hz;2pole

30 324063

4 5SU13242RC325SU13242RC405SU13242RC63

5780.-6335.-7635.-

111

100 324063

5SU14242RC325SU14242RC405SU14242RC63

6995.-7655.-8745.-

111

300 324063

5SU16242RC325SU16242RC405SU16242RC63

6840.-7655.-8755.-

111

415Vac;50…60Hz;4pole

30 324063

7 5SU13442RC325SU13442RC405SU13442RC63

7915.-8040.-9530.-

111

100 324063

5SU14442RC325SU14442RC405SU14442RC63

8575.-8955.-9925.-

111

300 324063

5SU16442RC325SU16442RC405SU16442RC63

8465.-9040.-9725.-

111

TypeAC,withCCharacteristics(in2modulesize)1 pole + N

30303030303030

300300300300300300300

6101620253240

6101620253240

2 5SU13541RC065SU13541RC105SU13541RC165SU13541RC205SU13541RC255SU13541RC325SU13541RC405SU16541RC065SU16541RC105SU16541RC165SU16541RC205SU16541RC255SU16541RC325SU16541RC40

4945.-4945.-4945.-4945.-4945.-5190.-6135.-5035.-5035.-5035.-5035.-5035.-5290.-6255.-

11111111111111

• Standards:IS12640,Part2:2008/IEC61009-1:1996• Voltage:240/415Vac,50…60Hz• WithISImarking:CM/LNo.7676193

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Page 16: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

16 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Betagard Residual Current Breaker Operators 5SU1, 10kA

Type A with C characteristic

Rated residual current I ∆n (mA)

Rated Current In (A)

MW# Reference No Unit MRP* R

Std. Pkg.** (Nos.)

240Vac;50…60Hz;2pole

30 324063

4 5SU13247RC325SU13247RC405SU13247RC63

8120.-8940.-

10110.-

111

100 324063

5SU14247RC325SU14247RC405SU14247RC63

8670.-9630.-

10945.-

111

300 324063

5SU16247RC325SU16247RC405SU16247RC63

8670.-9630.-

10945.-

111

415Vac;50…60Hz;4pole

30 324063

7 5SU13447RC325SU13447RC405SU13447RC63

9950.-10360.-11850.-

111

100 324063

5SU14447RC325SU14447RC405SU14447RC63

10665.-10875.-12150.-

111

300 324063

5SU16447RC325SU16447RC405SU16447RC63

10665.-11060.-12345.-

111

Type A with D characteristic240Vac;50…60Hz;2pole

30 324063

4 5SU13248RC325SU13248RC405SU13248RC63

9480.-10700.-12165.-

111

100 324063

5SU14248RC325SU14248RC405SU14248RC63

10200.-11345.-12920.-

111

300 324063

5SU16248RC325SU16248RC405SU16248RC63

10200.-11345.-12920.-

111

415Vac;50…60Hz;4pole

30 324063

7 5SU13448RC325SU13448RC405SU13448RC63

11735.-11880.-14010.-

111

100 324063

5SU14448RC325SU14448RC405SU14448RC63

12355.-13210.-14380.-

111

300 324063

5SU16448RC325SU16448RC405SU16448RC63

12355.-13210.-14385.-

111

TypeA,withCCharacteristics(in2modulesize)1 pole + N

30303030303030

300300300300300300300

6101620253240

6101620253240

2 5SU13547RC065SU13547RC105SU13547RC165SU13547RC205SU13547RC255SU13547RC325SU13547RC405SU16547RC065SU16547RC105SU16547RC165SU16547RC205SU16547RC255SU16547RC325SU16547RC40

9025.-9025.-9025.-9025.-9025.-9435.-

11420.-9295.-9295.-9295.-9295.-9295.-9665.-

11655.-

11111111111111

• Standards:IS12640,Part2:2008/IEC61009-1:1996• Voltage:240/415Vac,50…60Hz• WithISImarking:CM/LNo.7676193

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Page 17: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 17

Note:*MRP-MaximumRetailPrice #1MW(ModuleWidth)=18mm$ForSPNRCBOs,theaccessoriescanbeusedalongwithHandleconnectoronly**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Betagard Accessories

Accessories for 5SL6 / 5SL4 / 5SY7 / 5SY5 / 5SP4 MCBs and 5SU1$ RCBOs

Item Description Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Aux contact block (for5SL/5SY/5SP4/5SU1)

1NO+1NC2NO2NC

5ST30105ST30115ST3012

900.-915.-915.-

1211

Fault signal contact (for5SL/5SY/5SP4/5SU1)

1NO+1NC2NO2NC

5ST30205ST30215ST3022

1325.-1345.-1345.-

111

Shunt release (for5SY/5SP4/5SU1)

110…415V AC24…48V DC

5ST30305ST3031

3715.-3715.-

1/51/5

Undervoltage release (for5SY/5SP4/5SU1)

Withintegratedaux.switch

230V AC110V DC24V DC

5ST30405ST30415ST3042

4980.-4980.-4980.-

1/51/51/5

Withoutintegratedaux.switch

230V AC110V DC24V DC

5ST30435ST30445ST3045

4980.-4980.-4980.-

1/51/51/5

Remotecontrolmechanism(RC)230VAC,3.5MW,for5SPMCB&5SURCBO5SM RCCBs5SY……CC CBs

5ST30505ST30515ST3052

28550.-28550.-49795.-

111

Handlelockingdevice

for 5SP and 5SY circuit breakers for padlock with max. 3mm shackle

for 5SL miniature circuit breakers for padlock with max. 3 to 6 mm shackle

5ST3801

5ST3806

460.-

435.-

1

5

Pad locksfor 5ST3801 and 5ST3806 handle locking devices 5ST3802 290.- 5

HandleconnectorforSPNRCBOs 5ST38051 920.- 1

Accessories for Residual Current Circuit Breakers, Type 5SM3

Item Description Reference No. Unit MRP* R

Std. Pkg.** (Nos.)

Auxcontactblock1NO+1NC,25Ato80A 5SW3300 2030.- 1/10

Auxcontactblock1NO+1NC,100Ato125A 5SW3330 4205.- 1/10

BetagardRotaryHandleAssembly

Item Description Reference No. Unit MRP* R

Std. Pkg.** (Nos.)

Rotary Handle Assembly for 5SY, 5SL, 5SP and 5TL1seriesofMCBs/Isolators

5ST38140RC 1655.- 1

Page 18: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

18 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

AsthefirstAFDunit,theprotectiondeviceprotectshumanlivesandbuildingsreliablyagainstfirescausedbyelectricity.

The5SM6AFDunitfromSiemensisthefirstoneofitskindthatdetects serial arcing faults at an early stage. It is established since 2012andfulfillsallrelevantrulesandstandards.Withthepublishing of the IEC 60364-4-42, the installation is strongly recommended all over Europe.

The 5SM6 AFD unit closes the existing safety gap and is part of a complete protection concept by Siemens – one stop safety

Arc Fault Detection DeviceFirst in Safety

www.siemens.com/afd-units

Page 19: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd.ElectricalInstallationMRPEff.01-05-2017 19

AFDunitswithamounted1+N,1MWMCBand5SU1RCBO

The smart solution.Whetherinanexistingplantoranewinstallation–the5SM6AFDunitcanbedeployedinanydistributionboard.Itquicklyidentifiesdangerousfaultscausedbyparallelorserialarcingfaultsandswitchesoffbeforeafireoccurs.TheAFDunitdetects operational arcing faults and only trips in the event of an actual fault.

Moreover the 5SM6 AFD unit offers:

ncomprehensivefireprotectionforhumans,plantsandassets

n reliable covering of the existing protection gap

nenhancedprotectionfromelectricalfiresincombinationwithMCBsorRCBOs

Reference no. Description

5SM60111XX02 AFDD16A,230V,2MW (Integratedwith1MW,1+N,6kA,16AMCB)

5SM6021-2 AFDD1-16A,230V,1MW (SuitableforSPNRCBO,RCBOtobeorderedseperately)

ForpricesandmoreoptionscontactsSiemensSalesOffice.

Read theQR code withyour QR codereader.

IEC

60364-4-42

CE

N

ELEC H D 60364

-4-4

2

siemens.com/product?5SM6

Page 20: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

20 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

• CompleterangeforResidential,CommercialandIndustrialInfrastructures

• DBsofferlatestdesignwithhighestaestheticappeal

• DBsavailablewithtypetestingasperthelatestapplicablestandards

• Userfriendlydesignofferseaseduringmaintenanceandassiststhe installer for correct installation

Perfect blend of beauty and features with assured performanceBetagard Distribution Boards

www.siemens.co.in

Page 21: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 21

Betagard Distribution Boards 8GB32 SPN and TPN DBs

Item Description Incoming Slots

Outgoing Slots

Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Metal Enclosures, IP20:1 Module – – 1 8GB32100RC01 390.- 1/20

2 Module – – 2 8GB32100RC02 580.- 1/20

3 Module – – 3 8GB32100RC03 580.- 1/20

4 Module – – 4 8GB32100RC04 580.- 1/20

6 Module – – 6 8GB32100RC06 765.- 1/20

8 Module – – 8 8GB32100RC08 895.- 1/10

SPN Single Door DBs, IP20:6 Module 2 4 6 8GB32101RC06 1210.- 1

8 Module 2 6 8 8GB32101RC08 1280.- 1

10 Module 2 8 10 8GB32101RC10 1550.- 1

12 Module 2 10 12 8GB32101RC12 1610.- 1

14 Module 2 12 14 8GB32101RC14 1815.- 1

16 Module 2 14 16 8GB32101RC16 1955.- 1

SPN Metal Double Door DBs, IP 43:6 Module 2 4 6 8GB32102RC06 1895.- 1

8 Module 2 6 8 8GB32102RC08 1970.- 1

10 Module 2 8 10 8GB32102RC10 2290.- 1

12 Module 2 10 12 8GB32102RC12 2355.- 1

14 Module 2 12 14 8GB32102RC14 2740.- 1

16 Module 2 14 16 8GB32102RC16 2815.- 1

SPN Acrylic Double Door DBs, IP 43:6 Module 2 4 6 8GB32103RC06 2230.- 1

8 Module 2 6 8 8GB32103RC08 2355.- 1

10 Module 2 8 10 8GB32103RC10 2740.- 1

12 Module 2 10 12 8GB32103RC12 2945.- 1

14 Module 2 12 14 8GB32103RC14 3075.- 1

16 Module 2 14 16 8GB32103RC16 3205.- 1

Wire Way Box For SPN Single Door IP 20 DBs:For6MODSPNSingledoorDB – – – 8GB32106RC06 795.- 1/5

For8MODSPNSingledoorDB – – – 8GB32106RC08 795.- 1/5

For10MODSPNSingledoorDB – – – 8GB32106RC10 860.- 1/5

For12MODSPNSingledoorDB – – – 8GB32106RC12 860.- 1/5

For14MODSPNSingledoorDB – – – 8GB32106RC14 990.- 1/5

For16MODSPNSingledoorDB – – – 8GB32106RC16 990.- 1/5

Wire Way Box For SPN Double Door IP 43 DBs:For6MODSPNDoubledoorDB – – – 8GB32107RC06 860.- 1/5

For8MODSPNDoubledoorDB – – – 8GB32107RC08 860.- 1/5

For10MODSPNDoubledoorDB – – – 8GB32107RC10 930.- 1/5

For12MODSPNDoubledoorDB – – – 8GB32107RC12 930.- 1/5

For14MODSPNDoubledoorDB – – – 8GB32107RC14 1185.- 1/5

For16MODSPNDoubledoorDB – – – 8GB32107RC16 1185.- 1/5

Note:*MRP-MaximumRetailPriceForCustomizedSolutionsinDistributionBoardspleaseContactoursalesOffice**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

• TypeTestedasperIEC61439Standardsatneutralandinternaltestlaboratories.• AvailableinIP20andIP43Versions.• SingleDoor,MetalDoubleDoorandAcrylicDoubleDooroptionsavailable.• StandardWireWayBoxesavailableforallsingleDoorandDoubleDoorDBs.• AdditionalsafetytousersandInstallersbyInsulatedShortingLinks,ShroudedNeutralLinksandDoorEarthing.• TPNDBscanbeeasilymadesuitableforPPIconfigurationusingTPNtoPPIConversionKits.• DetachableDinrailassemblyandintermittentdoorfacilitateseaseinWiringduringinstallationandmaintenance.• DBsaremanufacturedbylatesttechnologywith18SWGand16SWGCRCASteel.• DBsaresubjectedtoseventanksProcessandtreatedwithPremierqualitypowdercoating.• CementMaskingSheetprotectstheDBsagainstextremesiteconditions.• DBsaresuppliedinDualPackingforsafetyduringtransitandstorage.

Page 22: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

22 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Betagard Distribution Boards 8GB32 SPN and TPN DBs

Item Description Incoming Slots

Outgoing Slots

Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

TPN Single Door DBs, IP20:4 way 8 12 20 8GB32201RC04 3045.- 1

6 way 8 18 26 8GB32201RC06 3465.- 1

8 way 8 24 32 8GB32201RC08 4180.- 1

10 way 8 30 38 8GB32201RC10 6065.- 1

12 way 8 36 44 8GB32201RC12 6195.- 1

14 way 8 42 50 8GB32201RC14 7105.- 1

16 way 8 48 56 8GB32201RC16 7370.- 1

TPN Metal Double Door DBs, IP 434 way 8 12 20 8GB32202RC04 3730.- 1

6 way 8 18 26 8GB32202RC06 4505.- 1

8 way 8 24 32 8GB32202RC08 5415.- 1

10 way 8 30 38 8GB32202RC10 7825.- 1

12 way 8 36 44 8GB32202RC12 8015.- 1

14 way 8 42 50 8GB32202RC14 9515.- 1

16 way 8 48 56 8GB32202RC16 9780.- 1

TPN Acrylic Double Door DBs, IP 434 way 8 12 20 8GB32203RC04 4505.- 1

6 way 8 18 26 8GB32203RC06 5545.- 1

8 way 8 24 32 8GB32203RC08 6650.- 1

10 way 8 30 38 8GB32203RC10 8670.- 1

12 way 8 36 44 8GB32203RC12 10100.- 1

14 way 8 42 50 8GB32203RC14 10820.- 1

16 way 8 48 56 8GB32203RC16 11540.- 1

TPN to PPI Conversion Kit@

Toconvert6wayTPNDBto4wayTPNPPIDB 8GB32205RC04 2355.- 1/5

Toconvert8wayTPNDBto6wayTPNPPIDB 8GB32205RC06 2740.- 1/5

Toconvert10wayTPNDBto8wayTPNPPIDB 8GB32205RC08 2815.- 1/5

Toconvert12wayTPNDBto10wayTPNPPIDB 8GB32205RC10 3005.- 1/5

Toconvert14wayTPNDBto12wayTPNPPIDB 8GB32205RC12 3205.- 1/5

Toconvert16wayTPNDBto14wayTPNPPIDB 8GB32205RC14 3395.- 1/5

Wire Way Box For TPN Single Door IP 20 DBsFor4WayTPNSingledoorDB – – – 8GB32206RC04 990.- 1/5

For6WayTPNSingledoorDB – – – 8GB32206RC06 990.- 1/5

For8WayTPNSingledoorDB – – – 8GB32206RC08 1770.- 1/5

For10WayTPNSingledoorDB – – – 8GB32206RC10 2230.- 1/5

For12WayTPNSingledoorDB – – – 8GB32206RC12 2290.- 1/5

For14WayTPNSingledoorDB – – – 8GB32206RC14 2355.- 1/5

For16WayTPNSingledoorDB – – – 8GB32206RC16 2490.- 1/5

Wire Way Box For TPN Double Door IP 43 DBsFor4WayTPNDoubledoorDB – – – 8GB32207RC04 1055.- 1/5

For6WayTPNDoubledoorDB – – – 8GB32207RC06 1185.- 1/5

For8WayTPNDoubledoorDB – – – 8GB32207RC08 1895.- 1/5

For10WayTPNDoubledoorDB – – – 8GB32207RC10 2025.- 1/5

For12WayTPNDoubledoorDB – – – 8GB32207RC12 2490.- 1/5

For14WayTPNDoubledoorDB – – – 8GB32207RC14 2615.- 1/5

For16WayTPNDoubledoorDB – – – 8GB32207RC16 2690.- 1/5

Note:*MRP-MaximumRetailPrice@ContainsrequiredaccessoriestoMaketheDBsuitableforPPIConfigurationForCustomizedSolutionsinDistributionBoardspleaseContactoursalesOffice**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Page 23: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 23

Item Description Incoming Slots

Sub - Incomer Slots

Outgoing Slots

Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

TPN Phase segregated DBs, IP 20 For MCB as incomer4Way 12 12 12 36 8GB32001RC04 8400.- 1

6Way 12 12 18 42 8GB32001RC06 9450.- 1

8Way 12 12 24 48 8GB32001RC08 11025.- 1

12Way 12 12 36 60 8GB32001RC12 13125.- 1

TPN Phase segregated DBs, IP 43 For MCB as incomer4 way 12 12 12 36 8GB32002RC04 9975.- 1

6 way 12 12 18 42 8GB32002RC06 11550.- 1

8 way 12 12 24 48 8GB32002RC08 13125.- 1

12 way 12 12 36 60 8GB32002RC12 15750.- 1

TPN Phase segregated DBs, IP 43 for MCCB as incomer upto 160A6 way 12 18 30 8GB32012RC06 17850.- 1

8 way 12 24 36 8GB32012RC08 20475.- 1

12 way 12 36 48 8GB32012RC12 23100.- 1

Wire Way box for MCB Incomer, IP 43 DBsFor4Way – – – – 8GB32007RC04 2625.- 1

For6Way – – – – 8GB32007RC06 3150.- 1

For8Way – – – – 8GB32007RC08 3675.- 1

For12Way – – – – 8GB32007RC12 4200.- 1

Wire Way box for MCCB Incomer, IP 43 DBsFor6Way – – – – 8GB32017RC06 3150.- 1

For8Way – – – – 8GB32017RC08 3675.- 1

For12Way – – – – 8GB32017RC12 4200.- 1

Betagard Distribution Boards 8GB32 TPN Phase Segregated DBs

Betagard Distribution Boards MB DBs

Item Description Incoming Slots

Outgoing Slots

Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Betagard MB (Ivory White) :1Row, 6Mod 2 4 6 8GB31810RC01 1530.- 1/10

1Row, 8Mod 2 6 8 8GB31811RC01 1775.- 1/10

1Row, 10Mod 2 8 10 8GB31812RC01 1975.- 1/10

1Row, 12Mod 2 10 12 8GB31813RC01 2100.- 1/10

1Row, 14Mod 2 12 14 8GB31814RC01 2225.- 1/10

1Row, 16Mod 2 14 16 8GB31815RC01 2665.- 1/10

Betagard MB (Metallic Grey) :1Row, 6Mod 2 4 6 8GB31810RC02 1590.- 1/10

1Row, 8Mod 2 6 8 8GB31811RC02 1850.- 1/10

1Row, 10Mod 2 8 10 8GB31812RC02 2100.- 1/10

1Row, 12Mod 2 10 12 8GB31813RC02 2225.- 1/10

1Row, 14Mod 2 12 14 8GB31814RC02 2350.- 1/10

1Row, 16Mod 2 14 16 8GB31815RC02 2795.- 1/10

Betagard MB (Metallic Carbon) :1Row, 6Mod 2 4 6 8GB31810RC03 1590.- 1/10

1Row, 8Mod 2 6 8 8GB31811RC03 1850.- 1/10

1Row, 10Mod 2 8 10 8GB31812RC03 2100.- 1/10

1Row, 12Mod 2 10 12 8GB31813RC03 2225.- 1/10

1Row, 14Mod 2 12 14 8GB31814RC03 2350.- 1/10

1Row, 16Mod 2 14 16 8GB31815RC03 2795.- 1/10

Page 24: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

24 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Betagard Distribution Boards 8GB0 SPN and TPN DBs

Item Description Incoming Slots

Outgoing Slots

Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Plastic Enclosure, IP20:

3/4Way – – 4 8GB0004 220.- 1/50

6Way – – 6 8GB0006 340.- 1/25

Double Door SPN DBs, IP42 :

4Way 2 4 6 8GB0204RC 1830.- 1

6Way 2 6 8 8GB0206RC 1885.- 1

8Way 2 8 10 8GB0208RC 2210.- 1

12Way 2 12 14 8GB0212RC 2635.- 1

14Way 2 14 16 8GB0214RC 2705.- 1

DoubleDoorTPNDBs(Horizontal),IP42:

4Way 8 12 20 8GB0404HRC 3585.- 1

6Way 8 18 26 8GB0406HRC 4395.- 1

8Way 8 24 32 8GB0408HRC 5335.- 1

12Way 8 36 44 8GB0412HRC 7705.- 1

Double Door TPN DBs (Vertical), IP42 :

4Way 8 12 20 8GB0404VRC 4750.- 1

6Way 8 18 26 8GB0406VRC 5130.- 1

8Way 8 24 32 8GB0408VRC 5890.- 1

12Way 8 36 44 8GB0412VRC 8290.- 1

DoubleDoor,PerPhaseIsolationTPNDBs(Horizontal),IP42:

4Way 8 18 26 8GB0405HRC 6265.- 1

6Way 8 24 32 8GB0407HRC 7210.- 1

8Way 8 30 38 8GB0409HRC 9615.- 1

12Way 8 42 50 8GB0413HRC 11575.- 1

Double Door, Per Phase Isolation TPN DBs (Vertical), IP42 :

4Way 8 18 26 8GB0405VRC 7080.- 1

6Way 8 24 32 8GB0407VRC 7780.- 1

8Way 8 30 38 8GB0409VRC 10695.- 1

12Way 8 42 50 8GB0413VRC 13095.- 1

Double Door, Phase Segregated TPN DBs (7 segment), IP42:

4Way 12 12+12 36 8GB0504 8670.- 1

6Way 12 12+18 42 8GB0506 9805.- 1

8Way 12 12+24 48 8GB0508 10945.- 1

12Way 12 12+36 60 8GB0512 13850.- 1

Page 25: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 25

Betagard Distribution Boards 8GB31

Item Description Incoming Slots

Outgoing Slots

Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Betaflex(FlexiDBs),IP42:2Row x 12Mod — — 24 8GB31424RC 4240.- 1

2Row x 16Mod — — 32 8GB31426RC 4500.- 1

4Row x 8Mod — — 32 8GB31442RC 5220.- 1

4Row x 12Mod — — 48 8GB31444RC 5805.- 1

4Row x 16Mod — — 64 8GB31446RC 8905.- 1

Betabus (Vertical Busbar DBs with MCB as an incomer), IP42 : (Suitable for 5SL/5SX/5SJ/5SP MCBs, upto 125A as an incomer)

4 way 12 12 24 8GB31471RC 8475.- 1

6 way 12 18 30 8GB31473RC 10310.- 1

8 way 12 24 36 8GB31474RC 10880.- 1

12 way 12 36 48 8GB31477RC 14795.- 1

Betabusplus (Vertical Busbar DBs with MCCB as an incomer), IP42 : (Suitable for 3VT1 MCCBs, upto 160A as an incomer)

4 way 12 12 24 8GB31571RC 9485.- 1

6 way 12 18 30 8GB31572RC 11960.- 1

8 way 12 24 36 8GB31573RC 12905.- 1

12 way 12 36 48 8GB31574RC 17195.- 1

BetaMulti(DBsforpower&communication),IP42:12waySPN,provision 2 12 14 8GB31215RC 4685.- 1

4WayTPN,Provision 8 12 20 8GB31220RC 5820.- 1

6wayTPN,provision 8 18 26 8GB31221RC 6075.- 1

8WayTPNProvision 8 24 32 8GB31222RC 6710.- 1

12waySPN,built-in 2 12 14 8GB31315RC 6265.- 1

4WayTPN,Built-in 8 12 20 8GB31320RC 7335.- 1

6wayTPN,built-in 8 18 26 8GB31321RC 7850.- 1

8WayTPN,Built-in 8 24 32 8GB31322RC 8355.- 1

Beta CO (DBs with provision for phase changeover switches), IP42 :4 way, with provision 8 12 20 8GB31840RC 8165.- 1

6 way, with provision 8 18 26 8GB31841RC 8290.- 1

8 way, with provision 8 24 32 8GB31842RC 9050.- 1

12 way, with provision 8 36 44 8GB31844RC 10750.- 1

Beta CO (DBs with built-in pre-wired phase changeover switches), IP42 :40A,4WayTPN,built-in 8 12 20 8GB31850RC 11640.- 1

40A,6WayTPN,built-in 8 18 26 8GB31851RC 12010.- 1

40A,8WayTPN,built-in 8 24 32 8GB31852RC 12645.- 1

40A,12WayTPN,built-in 8 36 44 8GB31854RC 15180.- 1

63A,4WayTPN,built-in 8 12 20 8GB31860RC 12140.- 1

63A,6WayTPN,built-in 8 18 26 8GB31861RC 12520.- 1

63A,8WayTPN,built-in 8 24 32 8GB31862RC 13660.- 1

63A,12WayTPN,built-in 8 36 44 8GB31864RC 15430.- 1

Note:* MRP - Maximum Retail Price ForCustomizedSolutionsinDistributionBoardspleaseContactoursalesOffice**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Page 26: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

26 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

WireWayBoxes&ModularDeviceBoxes

Note:* MRP - Maximum Retail Price ForCustomizedSolutionsinDistributionBoardspleaseContactoursalesOffice**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Item Description Incoming Slots

Outgoing Slots

Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Wire Way Boxes (WWB)WWBforFlexiDB,8Mod — — — 8GB9908FWWNT 1145.- 1/5

WWBforFlexiDB,12Mod — — — 8GB9912FWWNT 1275.- 1/5

WWBforFlexiDB,16Mod — — — 8GB9916FWWNT 1530.- 1/5

WWBforBusDB — — — 8GB99BUSWWNT 1715.- 1/5

WWBforBusPlusDB — — — 8GB99BPLUSWWNT 1850.- 1/5

Modular Device Boxes (MDB)MDBforFlexiDB,8Mod/Row — — 8 8GB9908FMDTC 1400.- 1/5

MDBforFlexiDB,12Mod/Row — — 12 8GB9912FMDTC 1590.- 1/5

MDBforFlexiDB,16Mod/Row — — 16 8GB9916FMDTC 1775.- 1/5

MDB for Bus DB — — 12 8GB99BUSMBTC 1975.- 1/5

MDB for Bus Plus DB — — 12 8GB99BPLUSMBTC 2155.- 1/5

Simbox WP

Item Description Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Simbox WP (IP65 DBs)1 Row, 4Mod 4 8GB13710 3685.- 1

1 Row 8Mod 8 8GB13711 4690.- 1

1 Row 12Mod 12 8GB13712 8365.- 1

1 Row 18Mod 18 8GB13713 10840.- 1

2 Row 2 x 12Mod 24 8GB13722 13375.- 1

2 Row, 2 x 18Mod 36 8GB13723 18865.- 1

3 Row, 3 x 18Mod 54 8GB13733 33170.- 1

4 Row 4 x 18Mod 72 8GB13743 43465.- 1

Accessories for Simbox WPCoupling covers,12M 8GB20510 1210.- 1

Coupling covers,18M 8GB20511 1350.- 1

InsulatedN/PEterminals,8MW 8GB20520 1880.- 1

InsulatedN/PEterminals,12MW 8GB20521 2880.- 1

InsulatedN/PEterminals,18MW 8GB20522 4225.- 1

Cylindrical security lock 8GB20550 3425.- 1

Industrialplug&sockets

Item Description Total Slots

Reference No Unit MRP* R

Std. Pkg.** (Nos.)

Plug&Socket,IP20withprovisionforMCBmounting:1 Phase 20A, 1P MCB 1 8GB0501RC 1340.- 1/20

1 Phase 20A, 2P MCB 2 8GB0501SRC 1340.- 1/20

3 Phase 32A, 3P MCB 3 8GB0502 2850.- 1/15

3Phase32A,3P+NMCB 4 8GB0502S 2850.- 1/15

5Pin(3P+N+PE)3Phase32AMCB3P+NMCB 8 8GB050332 4490.- 1/5

5Pin(3P+N+PE)3Phase63AMCB3P+NMCB 8 8GB050363 11710.- 1/5

Page 27: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 27

Betagard Distribution Boards Accessories

Item Description Reference No Unit MRP* R

Std. Pkg. Unit**

Blanking Plate

0.5MW 8GB9905 20.- 25 nos.

1MW 8GB9901 40.- 25 nos.

1.5MW 8GB9902 45.- 25 nos.

Insulated Shorting Links

Single Phase Shorting Links for Shorting 1P MCBs, Suitable for Standard SPN, TPN and TPN PPI DBs

5 Leg SP Shorting Link (For4WaySPNDBand4WayPPIDB) 8GB9905LSP 135.- 10 nos.

7 Leg SP Shorting Link (For6WaySPNDBand6WayPPIDB) 8GB9907LSP 160.- 10 nos.

9LegSPShortingLink (For8WaySPNDBand8WayPPIDB) 8GB9909LSP 185.- 10 nos.

11 Leg SP Shorting Link (For10WaySPNDBand10WayPPIDB) 8GB9911LSP 205.- 10 nos.

13 Leg SP Shorting Link (For12WaySPNDBand12WayPPIDB) 8GB9913LSP 265.- 10 nos.

15 Leg SP Shorting Link (For14WaySPNDBand14WayPPIDB) 8GB9915LSP 325.- 10 nos.

17 Leg SP Shorting Link (For16WaySPNDBand16WayPPIDB) 8GB9917LSP 340.- 10 nos.

4 Leg SP Shorting Link (For4WayTPNDB) 8GB9904LSP 135.- 10 nos.

6 Leg SP Shorting Link (For6WayTPNDB) 8GB9906LSP 160.- 10 nos.

8 Leg SP Shorting Link (For8WayTPNDB) 8GB9908LSP 185.- 10 nos.

10 Leg SP Shorting Link (For10WayTPNDB) 8GB9910LSP 205.- 10 nos.

12 Leg SP Shorting Link (For12WayTPNDB) 8GB9912LSP 265.- 10 nos.

14 Leg SP Shorting Link (For14WayTPNDB) 8GB9914LSP 325.- 10 nos.

16 Leg SP Shorting Link (For16WayTPNDB) 8GB9916LSP 340.- 10 nos.

Two Phase, 1 meter long for shorting 2P MCBs (suitable for maximum of 28 nos. 2MW devices)

Shorting link without End caps, Can be cut and used. 8GB990SLLDP 3360.- 1 no.

End Caps for 2 pole Shorting Links 8GB990ECLDP 55.- 10 nos.

Three Phase, 1 meter long for shorting 3P MCBs (suitable for maximum of 19 nos. 3MW devices)

Shorting link without Enc caps, Can be cut and used. 8GB990SLLTP 3675.- 1 no.

End Caps for 3 pole Shorting Links 8GB990ECLTP 80.- 10 nos.

Three Phase + N, 1 meter long for shorting TPN MCBs (suitable for maximum of 14 nos. 4MW devices)

Shorting link without Enc caps, Can be cut and used. 8GB990SLLTPN 3885.- 1 no.

End Caps for 3 pole Shorting Links 8GB990ECLTPN 105.- 10 nos.

Neutral Terminals

Neutral Terminals For 8GB0 and 8GB31 DBs (Along with Mounting Stands)

5WayNeutralLink 8GB9905NL 145.- 10 nos.

11WayNeutralLink 8GB9911NL 220.- 10 nos.

13WayNeutralLink 8GB9913NL 250.- 10 nos.

15WayNeutralLink 8GB9915NL 280.- 10 nos.

Neutral Terminals For 8GB32 DBs (With Terminal Shroud and Cover)

NeutralTerminal5Holes 8GB9905NPE 160.- 10 nos.

NeutralTerminal11Holes 8GB9911NPE 230.- 10 nos.

NeutralTerminal13Holes 8GB9913NPE 265.- 10 nos.

NeutralTerminal15Holes 8GB9915NPE 295.- 10 nos.

Earth Terminals

5WayEarthLink 8GB9905EL 125.- 10 nos.

11WayEarthLink 8GB9911EL 210.- 10 nos.

13WayEarthLink 8GB9913EL 230.- 10 nos.

15WayEarthLink 8GB9915EL 265.- 10 nos.

Note:*MRP-MaximumRetailPrice**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Page 28: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

28 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Modular Devices

Type 1 Lightning ArrestorsType 1 Lightning Arresters include the system cables in the equipotential bonding, which protect the low-voltage systems against the over voltages and high surge currents that can be triggered by direct or indirect lighting strikes.

The protection level of is lowered to 1.5kV by the lightning arrester, which reduces the load on the plant if a lightning strike is discharged.

The lightning arrester are enclosed and are suitable for installation in the precounter area.

All spark gaps are tripped, so that decoupling reactors are no longer required for the installation of overvoltage protection devices.

Thelightningarrestersaretestedbywave-shapedlightingimpulse,25...100kAwithWaveform10/350µs.

Type 2 Surge ArresterSurge Arresters type 2 are used downstream of Lightning Arresters Type 1 in main distribution boards or sub-distribution boards. They protect Low Voltage systems against transient over voltages.

Thetype2surgearresterslowersthelevelofprotectionto1.4to1.5KV.

Type 3 Surge ArresterType 3 Surge Arresters are installed downstream of the type 2 surge arresters in Sub-Distribution Boards close to the loads in Single or multiphase systems and further limit the over voltage in order to protect the connected loads.

*AlsoavailableDCSPDsforSolarapplications-contactSiemenssalesofficeforfurtherdetails

Surge protection Devices

Item Description Type Discharge Capacity kA

MW# Reference No Unit LP* R

Std. Pkg.** (Nos.)

Lightning Arrestor Type 1, Requi. Class B, UC 350V, Protection Blocks Plug In 3pole,3+0Circuit.ForTN-CSystemswith Remote Display

Type 1 75 6 5SD74131 51890.- 1

Lightning Arrestor Type 1, Requi., Class B, UC 350V, Protection Blocks Plug -In 4Pole,3+1CircuitforTN-SandTTSystems

Type 1 100 8 5SD74141 64585.- 1

Surge Arrestor Type 2, Requi., Class C, UC 350V, Protection Blocks Plug -In 3 Pole,3+0CircuitforTNCSystems

Type 2 40 3 5SD74630 23660.- 1

Surge Arrestor Type 2, Requi Cat.C, UC 350VAC, Protection Blocks Plug In4pole,3+1CircuitforTN-SandTTsystems

Type 2 40 4 5SD74640 24735.- 1

Surge Arrestor type 2, Requirement Class C, UC350V Protection Blocks Plug In1Pole,L-NCircuit

Type 2 40 1 5SD74610 6535.- 1

Surge Arrestor type 2, Requirement Class C, UC260V Protection Blocks Plug In1Pole,N-PECircuit

Type 2 40 1 5SD74810 5945.- 1

Surge Arrestor type 3, Requirement ClassD,RatedVoltageUN230V,UC275VDC/253VAC,2Pole,for1-Phase Power Supply

Type 3 10 1 5SD74321 11065.- 1

PlugpartType1N-PE,RequirementClass B, UC 350V 1-Pole For Lighting Conductor 5SD741

Type 1 - 5SD74180 12165.- 1

PlugpartType2L-N,RequirementClassC,UC 350V 1-Pole For Surge Arrestor 5SD746...

Type 2 - 5SD74681 4780.- 1

PlugpartType2N-PE,RequirementClass C, UC 260V 1-Pole For Surge Arrestor 5SD746…, 5SD747…, 5SD74810

Type 2 - 5SD74880 4780.- 1

Plug Part Type 3 Requirement Class DRatedVoltageUN230V2pole,1-Phase For Surge Arrestor 5SD74321

Type 3 - 5SD74371 6540.- 1

Note:*LP-ListPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Page 29: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd.ElectricalInstallationMRPEff.01-05-2017 29

Modular Devices

Item Description Rated Current In (A)

MW# Reference No Unit LP* R

Std. Pkg.** (Nos.)

Changeover switches Standards: IEC 60947-3/DIN EN 60947-3

1C/O,230V 20 1 5TE8161 1575.- 1/10

2C/O,400V 20 1 5TE8162 2870.- 1/10

Group switch, center position, 2C/O,400V

20 1 5TE8142 3315.- 1/10

Insta Contactors Standards: EN 60947-4-1, EN 60947-5-1

2NOcontacts,230Vac 20 1 5TT58000 2500.- 1/5

3NO+1NCcontacts,230Vac/220Vdc(1NCcontactratedfor30A)

40 3 5TT58410 6835.- 1/5

3NO+1NCcontacts,24Vac/24Vdc (1NCcontactratedfor30A)

40 3 5TT58412 6860.- 1/5

4NOcontacts,230Vac/220Vdc 40 3 5TT58400 6880.- 1/5

4NOcontacts,24Vac/24Vdc 40 3 5TT58402 6760.- 1/5

3NO+1NCcontacts,230Vac/220Vdc(1NCcontactratedfor30A)

63 3 5TT58510 9510.- 1/5

3NO+1NCcontacts,24Vac/24Vdc, (1NCcontactratedfor30A)

63 3 5TT58512 10055.- 1/5

4NOcontacts,230Vac/220Vdc 63 3 5TT58500 8720.- 1/5

4NOcontacts,24Vac/24Vdc 63 3 5TT58502 9195.- 1/5

Insta Contactors Manual / Automatic with Switching Indicator Standards: IEC60947-4-1, IEC60947-5-1

2NOcontacts,230Vac 20 1 5TT58006 3325.- 1/5

1NO+1NCcontacts,230Vac 20 1 5TT58016 5005.- 1/5

4NOcontacts,230Vac 25 2 5TT58306 4710.- 1/5

4NOcontacts,400Vac 40 3 5TT58406 10360.- 1/5

4NOcontacts,400Vac 63 3 5TT58506 13130.- 1/5

Accessories

Control Switch with 1 Make and 1BreakContactForAC230V/400VFor5TT58 and 5TT50

5TT59101 2840.- 1/10

Note:*LP-ListPrice #1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Measuring Selector switches are used as CO contacts of the phase for voltages and currents in 3-phase systems for Voltmeters and Ammeters. The design of these switches is adapted to match the modular installation devices. They support useincompliancewithEN60947-3.Thedevicehasaratedinsulationvoltageof660V.Thispermitsuseinmanysystems.

Item Description Voltage V AC

Voltage V DC

Current A AC

MW# Reference No Unit LP* R

Std. Pkg.** (Nos.)

Measuring Selector Switches

Voltmeter Selector Switches

400 6 12 3 7KT9010 5295.- 1

Ammeter Selector Switches for Transformer operation

400 6 12 3 7KT9011 5795.- 1

Page 30: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

30 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Modular Devices

Note:*LP-ListPrice #1MW(ModuleWidth)=18mm

Item Description Rated Current In (A)

MW# Reference No Unit LP* R

Std. Pkg.** (Nos.)

Voltage Relays Standards : IEC 60255, DIN VDE 0435-303

Voltage relay for undervoltage monitoringof1,2,3phasesagainstNwith phase failure detection, Switching thresholds07-0.9xV,notadjustable;2C/Ocontacts,4A,230/400Vac

4 2 5TT3402 10960.- 1

Voltage relay for undervoltage monitoring of 1,2,3 phases against N,shorttimefailuredetectionwith phase failure detection and Nconductormonitoring,Switchingthresholds 0.8-0.85xV, not adjustable; 2C/Ocontacts,230/400Vac

4 2 5TT3407 18245.- 1

Voltage relay for over and undervoltage monitoringof3phasesagainstNwithasymmetry, reverse voltage and phase failuredetectionwithNconductormonitoring and adj. Time delay of 0.1 to20s,Switchingthresholds:U/voltage0.7-1.1xV, 4% hysteresis, adjustable, O/voltage0.9-1.1xV,4%hysteresis,adjustable;2C/Ocontacts,230/400Vac

4 2 5TT3408 21005.- 1

NeutralconductormonitorwithasymmetrydetectionandNconductormonitoring,2C/Ocontacts,230/400Vac

4 2 5TT3410 17510.- 1

Ammeters&Voltmeters

Digital Voltmeter, 12…600Vac 2 7KT1110 15155.- 1/5

Digital Ammeter, direct connection 0.4…20A(WithCTs0.1….1000/5)

2 7KT1120 15155.- 1/5

RYG 3 phase indicator in 1MW

3phaseindicator(allwithgreencolorcap)

1 5TE5802 2830.- 1/10

3phaseindicator(red/yellow/green) 1 5TE5803 2405.- 1/10

Transparentcap(1set=3items,R,Y,Glens)

5TG8070 780.- 1/10

Power ON Indicator (Economy Version’) 230 Vac, 1 Phase

Light indicators for max. cable length up to 5 m with 1 red lamp

1 5TE5800 1495.- 1/12

Light indicators for max. cable length up to 250 m with 1 red lamp

1 5TE5804 1195.- 1/12

Transparentcap(Red) 5TG8061 110.- 5

Transparentcap(Green) 5TG8062 110.- 5

Transparentcap(Yellow) 5TG8063 110.- 5

Transparentcap(Blue) 5TG8064 110.- 5

Fuse Monitor

Fuse monitors with transparent caps for all low voltage fuse systems, 230Vac

4 2 5TT3170 10335.- 1

Page 31: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 31

Item Description Rated Current In (A)

MW# Reference No Unit LP* R

Std. Pkg.** (Nos.)

Time Switches (Digital)

Minidigital,daily/weeklyprogram, 100 hours reserve, 230Vac

16 1 7LF44015 8545.- 1

Yearly time switch top digital 230V, 1 channel

16 2 7LF45110 7875.- 1

Yearly time switch top digital 230V, 2 channel

16 2 7LF45120 17135.- 1

Weeklytimeswitchprofidigital230V, 1 channel

16 2 7LF45210 15965.- 1

Weeklytimeswitchprofidigital230V,2 channel

16 2 7LF45220 20640.- 1

Weeklytimeswitchastrodigital230V, 1 channel

16 2 7LF45310 14270.- 1

Weeklytimeswitchastrodigital230V,2 channel

16 2 7LF45320 36990.- 1

Expertdigital,daily/weekly/yearly program,5yearsreserve,120/230Vac, 4 channels system

16 6 7LF44440 35860.- 1

Time Switches (Mechanical) Standards: EN 60730-1

Quartz-clock time switches with power reserve for wall mounting, day disk, 1CO, 250Vac

16 — 7LF53050 8610.- 1/5

Synchronous time switches without power reserve, for wall mounting, day disk, 1CO, 250Vac

16 — 7LF53010 5250.- 1/5

Accessories for Digital Time Switches

Datakeyforstoring&transferringdata (Expert)

7LF49402 1665.- 1

USB adapter and software 7LF49410 24270.- 1

Datakeyprofi,astro 7LF49411 2470.- 1

Note:* LP - List Price#1MW(ModuleWidth)=18mm**PurchaseMOQforourauthoriseddealersisinmultiplesofstandardpacking,contactSiemensSalesOfficeforfurtherdetails

Modular Devices

Terms and Conditions

• MRPs/LPsaresubjecttorevisionwithoutpriornotice.

• Thecompanyreservestherighttosupplygoodsatitsworksorgodownatitsdiscretion.

• Export control regulation - retention clause:ThefulfillmentoftheagreementonSiemenspartissubjecttotheprovisionthatthisshall not be prevented by implements on the grounds of national and international legal requirements, in particular export control provision.

• ThissupercedesallpreviousPriceLists

• MaximumRetailPrices(MRPs)mentionedinthispublicationaremax.recommendedsellingprices.

• ListpricesareinclusiveofED/CVD,howeverexclusiveofalllocaltaxesandlevies

Ask your nearest Siemens partners to include you in our mailing list.

Page 32: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

32 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

Moulded Case Circuit Breakers@

3VT1, 2, 3 MCCBs

3VT1#,415VAC,50HzMCCB,ThermalMagneticReleaseforlineprotection(FixedOverload&FixedShortCircuitSettings)

Rated Current, A

3VT1 3 pole Reference No.

Unit MRP* R

3VT1 4 pole Reference No

Unit MRP* R

Std. Pkg. (Nos.)

40 3VT1704-2DA36-0AA0 – 3VT1704-2EA46-0AA0 – 1

63 3VT1706-2DA36-0AA0 – 3VT1706-2EA46-0AA0 – 1

80 3VT1708-2DA36-0AA0 – 3VT1708-2EA46-0AA0 – 1

100 3VT1710-2DA36-0AA0 – 3VT1710-2EA46-0AA0 – 1

125 3VT1712-2DA36-0AA0 – 3VT1712-2EA46-0AA0 – 1

160 3VT1716-2DA36-0AA0 – 3VT1716-2EA46-0AA0 – 1

(AdjustableOverload&AdjustableShortCircuitSettings)

Rated Current, A

3VT1 3 pole Reference No.

Unit MRP* R

3VT1 4 pole Reference No

Unit MRP* R

Std. Pkg. (Nos.)

16 3VT1701-2DC36-0AA0 – 3VT1701-2EC46-0AA0 – 1

25 3VT1792-2DC36-0AA0 – 3VT1792-2EC46-0AA0 – 1

32 3VT1703-2DC36-0AA0 – 3VT1703-2EC46-0AA0 – 1

40 3VT1704-2DC36-0AA0 – 3VT1704-2EC46-0AA0 – 1

63 3VT1706-2DC36-0AA0 – 3VT1706-2EC46-0AA0 – 1

80 3VT1708-2DC36-0AA0 – 3VT1708-2EC46-0AA0 – 1

100 3VT1710-2DC36-0AA0 – 3VT1710-2EC46-0AA0 – 1

125 3VT1712-2DC36-0AA0 – 3VT1712-2EC46-0AA0 – 1

160 3VT1716-2DC36-0AA0 – 3VT1716-2EC46-0AA0 – 1

3VT2/3,415VAC,50HzMCCB,MicroprocessorbasedReleaseforlineprotection (AdjustableOverload&AdjustableShortCircuitSettings)

Rated Current, A

3VT2/3 (Base Unit) Reference No. 3 pole

Unit LP* R

3VT2/3 (Base Unit) Reference No. 4 pole

Unit LP* R

ETU Reference No.

Unit LP* R

3VT2&3,36kA

200A 3VT2725-2AA36-0AA0 – 3VT2725-2AA46-0AA0 – 3VT9225-6AC00 –

250A 3VT2725-2AA36-0AA0 – 3VT2725-2AA46-0AA0 – 3VT9225-6AC00 –

400A 3VT3763-2AA36-0AA0 – 3VT3763-2AA46-0AA0 – 3VT9340-6AC00 –

630A 3VT3763-2AA36-0AA0 – 3VT3763-2AA46-0AA0 – 3VT9363-6AC00 –

Accessories 3VT1 Reference No.

Unit MRP* R

3VT2 Reference No

Unit MRP* R

3VT3 Reference No.

Unit MRP* R

Auxiliary Switch$ 3VT9100-2AB10 – 3VT9300-2AC10 – 3VT9300-2AC10 –

Alarm Switch ^ 3VT9100-2AH10 – 3VT9300-2AD10 – 3VT9300-2AD10 –

Door mounted Rotary handle 3VT9100-3HQ00 – 3VT9200-3HQ00 – 3VT9300-3HQ00 –

Note : The ordering of Microprocessor based MCCB’s above 200A includes ordering of Base Unit + Electronic Trip Unit (ETU) separately$Auxiliaryswitchfor3VT1is1C/O&for3VT2,3is1NO;^Alarmswitchfor3VT1is1C/O&for3VT2,3is1NC; # 3VT1 MCCBs are suitable for mounting in Beta Bus Plus Distribution Boards@ Kindly refer latest Power Distribution Products Price List for prices

Raja DOL Starters@

3TW Direct On Line Starters

Ue:415V,3ph,50HzDOLStarterinsheetsteelhousing,includingbimetalrelaywithsinglephasing protection

Motor rating Relay Range A

Reference No1) Unit MRP* R

Std. Pkg. (Nos.)HP kW

0.330.7511.5235

-7.5

10

0.250.550.751.11.52.23.7

-5.57.5

0.63-11-1.61.6-2.52-3.23.2-54-6.36.3-108-12.510-1612.5-20

3TW42 90-1A.643TW42 90-1A.663TW42 90-1A.683TW42 90-1A.693TW42 90-1A.713TW42 90-1A.723TW42 90-1A.743TW42 90-1A.753TW42 90-1A.773TW42 90-1A.78

––––––––––

1111111111

1)Entercodeforcoilvoltage,50Hz(Bfor200-400V,Wfor415V) *MRP-MaximumRetailPrice LP-ListPrice@KindlyreferlatestMotorControlProductsPriceListforprices

Page 33: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 33

Switch disconnector fuse@

Superswitch 3KL8 in open execution TPN

Switch Disconnector fuse: 3KL8 for power distribution (in Open Execution TPN)Rated current Ie @690VAC50Hz

SDF suitable for DINtypeHRC

Fuses

SDF suitable for BStypeHRCFuses

SDF suitable for cylindricaltypeHRCFuses

Std. pkg. (nos.)

20A32A63A

100A125A160A200A250A315A400A$

500A630A800A$

3KL8111-3TA003KL8121-3TA003KL8151-3TA003KL8211-3TA003KL8221-3TA003KL8231-3TA003KL8311-3UA003KL8321-3UA003KL8331-3UA003KL8341-3UA003KL8411-3UA003KL8421-3UA003KL8431-3UA00

3KL8111-3TJ003KL8121-3TJ003KL8151-3TJ003KL8211-3TJ003KL8221-3TJ003KL8231-3TJ003KL8311-3UJ003KL8321-3UJ003KL8331-3UJ003KL8341-3UJ003KL8411-3UJ003KL8421-3UJ003KL8431-3UJ00

3KL8111-3TC003KL8121-3TC003KL8151-3TC00

––––––––––

1111111111111

SelectiontableforSSHousingfor3KL8

Rated current Ie (A)

Reference No Unit MRP* R

Std. Pkg. (Nos.)

3KL81(20A-63A)3KL82(100A-160A)3KL83(200A-400A)3KL84(500A-800A)

3KX8155-4AC3KX8235-4AC3KX8345-4AC3KX8435-4AC

––––

1111

Note:*MRP-MaximumRetailPrice@KindlyreferlatestPowerDistributionProductsPriceListforprices

LVHRCFuses@

DIN Type FuseRatedvoltage:500VAC

Size Rated current A

Reference No Unit MRP*

R

Std. Pkg.

(Nos.)

000 246

101620253240506380

100

3NA7 802-0RC3NA7 804-0RC3NA7 801-0RC3NA7 803-0RC3NA7 805-0RC3NA7 807-0RC3NA7 810-0RC3NA7 812-0RC3NA7 817-0RC3NA7 820-0RC3NA7 822-0RC3NA7 824-0RC3NA7 830-0RC

–––––––––––––

1/6

00 125160

3NA7 832-0RC3NA7 836-0RC

––

1 506380

100125160200224250

3NA7 120-0RC3NA7 122-0RC3NA7 124-0RC3NA7 130-0RC3NA7 132-0RC3NA7 136-0RC3NA7 140-0RC3NA7 142-0RC3NA7 144-0RC

–––––––––

1/3

#400&800Afuses-Ratedvoltageat415VAC

$- AC23A @ 550V AC

Size Rated current A

Reference No Unit MRP*

R

Std. Pkg.

(Nos.)

2 200250315400#

3NA7 240-0RC3NA7 244-0RC3NA7 252-0RC3NA7 260-0RC

––––

1/3

3 315400500630800#

3NA3 352-0RC3NA3 360-0RC3NA3 365-0RC3NA3 372-0RC3NA3 375-4RC

–––––

1/3

BS Fuses

Type Rated current A

Reference No Unit MRP* R

Std. Pkg. (Nos.)

Offset Tag

246

1016202532405063

3NW TIA23NW TIA43NW TIA63NW TIA103NW TIA163NW TIA203NW TIA253NW TIA323NW TIS403NW TIS503NW TIS63

–––––––––––

20

Page 34: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

34 Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017

• Modular&Simpleinstallation

• Easyscalability-sensorbars availablein3,6,9and12versions

• Upto96sensorsinasinglesystem

• Integratedwebserver

On- the-go access to energy data with the help of mobile app

Available for iOS/ Android

*Formoredetailsandprices,contactSiemensSalesOffice.

7KTPAC1200Multichannel current measuring system For flexible multichannel monitoring in final distribution

siemens.com/powermonitoring

Ordering Information*Type Description

7KT1260 Data manager

7KT1233 3-Sensor bar

7KT1236 6-Sensor bar

7KT1238 9-Sensorbar

7KT1242 12-Sensor bar

7KT1254 Sensor 40 A

7KT1255 Sensor 63 A

Page 35: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 35

Customer care

One point contact for your service needs

Please get in touch with us for details

CUSTOMER CARE

TollFreeNo:1800220987/18002090987•E-mail:[email protected]

The comprehensive range of services from Siemens is sure to covertheneedsofthemostvariedusers.Weofferstructured

services, designed to give you valuable support in every phase during the lifecycle of your Final Distribution Products.

Onestopsupportforallserviceneeds:

• Breakdownservice

• Annualmaintenancecontracts

• Retrofitsolutions

• Spares

For more details please contact:Customer care deskSiemens Ltd. R&DTechnologyCentreKalwaWorks,ThaneBelapurRoad,Thane-400601TollfreeNo.:18002090987(MTNL/BSNL/MajorMobileoperatorlines),1800220987(BSNL/MTNL)Tel.:022-27600150•Fax:022-33265381http://support.automation.siemens.com/in

Page 36: Our commitment is your safe futurelaxmielectricals.org/images/Price-List/Siemens/Electrical...Siemens Ltd. Electrical Installation MRP Eff. 01-05-2017 7 Note: * MRP - Maximum Retail

OrderNo.:107087087 DF-LP-0417-2017(ThisreplacesDF-LP-CC0967-2016dated01Sep2016)

CustomerCareTollfreeno.18002090987Email:[email protected]

Product upgradation is a continuous process. Hence, data in this pricelist is subject to change without prior notice. For the latest information, please get intouchwithourSalesOffices.

Siemens Ltd.Digital Factory Control Products R&DTechnologyCentre KalwaWorks,ThaneBelapurRoad,Thane-400601 Fax:+912233265627Formoreinformationcontacttollfree18002091800 E-mail:[email protected]

www.siemens.co.in

Your partnersSalesoffices:

Chennai4th Floor, ETA Mount Central Seethakathi Business Centre, Mount Road Chennai - 600006 (:+914430474000Fax:+914430474080

Coimbatore1st Floor, “Senthil Towers” 1078, Avinashi Road Coimbatore - 641018 (:+914223076300Fax:+914223076310

GurgaonPlotNo.-78,Tower-B JagatjitIndustriesBuilding(JIL) Opposite SBI Academy, Sector-18 Gurgaon - 122015 (:+911242842000,3810200

Hyderabad5-9-19,4th&5thFloor LaxmiNarasinhEstate Opp. Secretariat Road Saifabad Hyderabad - 500 004 (:+914030922500Fax:+914030923145

Jaipur6, Park Street Opp. Pink City Petrol Pump M.I.Road Jaipur - 302 006, Rajasthan (:+911415152108Fax:+911412370482

Jamshedpur“Roshan Tower” MainRoad,Bistupur(2ndFloor) Jamshedpur - 831001 (:+916576682201

Kolkata3rd Floor, 43, Shanti Palli Rashbihari Bypass Connector Kolkata-700042,India (:+913330939000Fax:+913330939010

Lucknow510-511, 5th Floor, Shalimar Titanium PlotNo.TC.G-1/1,VibhutiKhand GomtiNagar,Lucknow Uttar Pradesh 226010 (:+915224031039

MumbaiBusiness Centre-1 Thane Belapur Road, Thane - 400 601 (:+912239663000Fax:+912239663721

Gandhidham PlotNo.299,Ward3A,Adipur Gandhidham - 370205, Gujarat Mobile:+919099010323 E-mail:[email protected]

Goa HouseNo.S-2,ClassqueAppartment Porvorim, Goa - 403501 Mobile:+917722008113 E-mail:[email protected]

Gorakhpur FlatNo.3B,3rdFloor,PlotNo.298 NearSawatriHosiptal,Purdilpur Vijay Chowk, Gorakhpur - 273001, UP Mobile:+917800960310 E-mail:[email protected]

Gulbarga FlatNo.13,3rdFloor,ShubhaResidence DeshmukhLayout,Drajmapur,Kalaburagi GulbargaDistrict-585103,Karnataka Mobile:+917259661717 E-mail:[email protected]

GuwahatiHouseNo.20,Ushanagar Dispur Supermarket Guwahati - 781006, Assam, India Mobile:+919874484442 E-mail:[email protected] Mobile:+919903200417 E-mail:[email protected]

HaridwarPlotNo.3B,HouseNo.229/30 Deep Ganga Apartments, Sector - 5A SIDCUL,Haridwar-249403,UP Mobile:+919839102434 E-mail:[email protected]

Hospet RamanandResidency,FlatNo.204 1stMain,NehruCo-OpColony Hospet-583203,Karnataka Mobile:+919901400227 E-mail:[email protected]

Hospet Mahima’s,DoorNo.1288,9thWard NearMarkendeshwaraSchool M.P.PrakashNagar Hospet-583201,DisttBellary,Karnataka Mobile:+919945859004 E-mail:nagaraj,[email protected]

Hospet #727,LakshmiNarasimhaNilaya NearSurbhiKalyanaMantapa,Amaravathi Hospet - 583203 Mobile:+919741114877 E-mail:[email protected]

HosurPlotNo12VishnuAnandamGalaxy ChittanapalliNallurVillage,Hosur-635109 Mobile:+918971200266 E-mail:[email protected]

Hubli PlotNo-8,AbhiNilay ManjunathNagar,GokulRoad Hubli - 30 Mobile:+919945961052 E-mail:[email protected]

Indore C/oMr.MahendraNandedkar PlotNo.CH-30,SchemeNo.74 VijayNagar,NearPrestigeCollege Indore - 452010 Mobile:+919049149199 E-mail:[email protected]

IndoreMobile:+919823011883 E-mail:[email protected]

Jajpur KirtanEnclave,FlatNo.316,CBlock ChhordhaChaak,JajpurKeonjharRoad Jajpur,Odisha-755019 (NearestLandMark–SBIATMcounter) Mobile:+919937189624 E-mail:[email protected]

Jalandhar H.No.140,GroundFloor,DefenceColony Jalandhar, Punjab - 144001 Mobile:+918427979870 E-mail:[email protected]

JammuMobile:+919988951071 E-mail:[email protected]

Jodhpur Mobile:+919829244313 E-mail:[email protected]

Kanpur FlatNo.702,PushpiApartments ShardaNagar,Kanpur-208025,UP Mobile:+918650404404 E-mail:[email protected]

Khopoli 404,BuildingNo.5,AshiyanaVillage,Katrang Khopoli-410203,DistrictRaigad Mobile:+919867748975 E-mail:[email protected]

Kolhapur RSNo.84-1,PinacPrasad,Fl.No.A-35 NewPalaceRoad,Kolhapur-416006 Mobile:+919850836839 E-mail:[email protected]

Kota 406, Manglayatan Appartment NearJainTemple,BhimganjMandi Kota-324002 Mobile:+919828419111 E-mail:[email protected]

Ludhiana H.No.1858,FirstFloor,Sector-32A Ludhiana - 141008, Punjab Mobile:+919876047929 E-mail:[email protected]

Ludhiana H.No.728,FirstFloor,Sector-33 Chandigarh Rd., Ludhiana - 141010, Punjab Mobile:+919878094677 E-mail:[email protected]

LudhianaR-115,NearDAVSchool SarabhaNagarExtension,Phase-2 Pakhowal Road, Ludhiana, Punjab - 142022 Mobile:+919888484066 E-mail:[email protected]

MaduraiAnirudh Block F-Top 3 VasudharaApartment,84,TPKMainRoad Andalpuram,Madurai-625003,TamilNadu Mobile:+919894617776 E-mail:[email protected]

Meerut E-205, Ansal Courtyard, Roorkee Bypass Modipuram, Meerut - 250110, UP Mobile:+919720999887 E-mail:[email protected]

Meerut C-904,AnsalCourtyard,RoorkeeBypass Modipuram, Meerut - 250110, UP Mobile:+919999702981 E-mail:[email protected]

Mehsana B/26,TirupatiBungalows B/HDudhsagarDairy,RadhanpurRoad Mehsana - 384002 Mobile:+919909916971 E-mail:[email protected]

Moradabad31, Maitri Bagh, Dayal Bagh Agra, UP - 282005 Mobile:+917619047999 E-mail:[email protected]

Mysore No.980,4thCross,6thMain BannimantapBLayout,SSNagar Mysore - 570015 Mobile:+919611311645 E-mail:[email protected]

Naidupeta DoorNo.3-3-140,Raghavaiahpeta Sriharikota Road, Opp to Race School SullurpetaTown&Mandal SPSRNelloreDistrict,AP-524123 Mobile:+919840255185 E-mail:[email protected]

Nashik FlatNo.402,“D”Wing HariShrushtiApartment,NearJoggingPark Opp.WNSOffice,IndiraNagar Nashik-422009 Mobile:+919822193204 E-mail:[email protected]

Nashik FlatNo17,AnujaApartment NearGadkariChowk Nashik-422001 Mobile:+918055114173 E-mail:[email protected]

Neemrana FlatNo.F111,AnantrajAashrayApartment PlotNo.236,JapaneseZone Neemrana-301705,Dist.-Alwar Mobile:+919650481919 E-mail:[email protected]

PatnaSwastikEnclave,FlatNo.102 RamJaipalNagar,RoadNo.9,GolaRoad Baily Road, Patna - 801503 Mobile:+919771414108 E-mail:[email protected]

Pondicherry R.A.M.Paradise,IIFloor,No.4,2ndCross KambanNagar,Reddiarpalayam Puducherry - 605010 Mobile:+919176609374 E-mail:[email protected]

Raipur FlatNo.B-403,ShivVatikaApartment AshwaniNagar,Raipur Chhattisgarh-492013 Mobile:+919823935775 E-mail:[email protected]

Raipur 103 Risabh Regency NearShriMedishineHospital NewRajendraNagarRaipur(CG)-492001 Mobile:+919425601849 E-mail:[email protected]

Rajamahendravaram FlatNo.203,E-Block,RoyalCity DoorNo.3-15-1,Opp.EastRailwayStation Rajamahendravaram - 533102 Andhra Pradesh Mobile:+919948664228 E-mail:[email protected]

Rajkot 301, Snowhill Apartment NearGoldenSupermarket,AminMarg Rajkot - 360007, Gujarat Mobile:+919909904993 E-mail:[email protected]

Ranchi FlatNo.A-101,1stFloor SundaramApartment,KilburnColony Hinoo, Ranchi, Jharkhand - 834002 Mobile:+918294052647 E-mail:[email protected]

Ranchi 2/44NewAreaGandhiNagar FlatName-LilaRajSadhan,2ndFloor Hinoo, Ranchi - 834002 Mobile:+917766906595 E-mail:[email protected]

Renukoot RajBhawan(NearKhatuShyamMandir) Awadh Colony, Murdhwa, Renukoot Sonebhadra - 231217, UP Mobile:+919889384222 E-mail:[email protected]

Rourkela D/7,GafoorColony,GroundFloor NearLICOffice,UditNagar Rourkela-769012,Odisha Mobile:+919776967773 E-mail:[email protected]

Rourkela N/6,FlatNo.3A,CivilTownship OppositeHi-techMedicalCollege&Hospital Rourkela,Odisha-769004 Mobile:+919937972407 E-mail:[email protected]

Ahmedabad3rd Floor, Prerna Arbour GirishColdrinksCrossRoads,Navrangpura Ahmedabad-380009 (:+917930927600Fax:+917930927699

BarodaGround Floor, Urja Bhavan Opp.Makarpura Railway Station, Maneja Vadodara-390013 (:+912653957701Fax:+912653039190

Bengaluru1stFloor,JyotiMahal,No.49,St.MarksRd. Bengaluru - 560 001 (:+918033422000Fax:+918033424131

ChandigarhSCO188/191,3rdFloor,Sector-17C Chandigarh - 160 017 (:+911724690300Fax:+911724690399

Territory managers:AgraMobile:+917665590333 E-mail:[email protected]

Angul FlatNo.209,Block-B,2ndFloor OM Residency, Gandhi Marg InfrontofKalyaniNurshingHome Angul,Odisha-759122 Mobile:+919437114662 E-mail:[email protected]

Aurangabad Mobile:+919823011883 E-mail:[email protected]

BelgaumH.No.713,NarvekarLane,Shahpur Belgaum-590003,Karnataka Tel.:+9108312495156 Mobile:+919740277991 E-mail:[email protected]

Belgaum FlatNo.7,2ndFloor,JyotirlingPlaza Congress Road, Thilakwadi Belgaum-590011,Karnataka Mobile:+917259400100 E-mail:[email protected]

Belgaum 1stFloor,HNo.297,ShivachandraNiwas 3rdCrossBaghyaNagarAngolExtension Belgavi,Karnataka-590006 Mobile:+918105254395 E-mail:[email protected]

Bharuch Gold B, 804, Samruddhi Residency Opp.ZadeshwarBusStop,ZadeshwarRoad Bharuch-392011 Mobile:+919429037805 E-mail:[email protected]

Bhilai C/o.Mr.AnilDhusia,Qtr.No.4A,Street33 Sector-4,Bhilai-490001 Mobile:+917869922211 E-mail:[email protected]

BhopalFlatNo.103,Multi“E”Star,SagarRoyalVillas Nr.AshimaMall,HoshangabadRoad Bhopal(MP)-462026 Mobile:+919677400915 E-mail:[email protected]

Bhubaneswar 104Sector5,NiladriVihar Chandrasekharapur, Bhubaneswar Odisha - 751021 Mobile:+917399638488 E-mail:[email protected]

BhubaneswarPlotNo.233,ShahidNagar Bhubaneswar - 751007 Mobile:+917894436373 E-mail:[email protected]

Bhubaneswar PlotNo.486,FlatNo.302 ArchidRoyalApartment,NageswarTangi Bhubaneswar - 751002, Odisha Mobile:+919040001343 E-mail:[email protected]

Boisar FlatNo.A-21,SaiSagarCHS MAHADA Colony, Chitrayalaya Road Boisar - 401506 Mobile:+919819231892 E-mail:[email protected]

CochinJomerSymphony,33/2317,5thFloor Chalikkavattom,PonnurunniNorth,Vytilla Kochi-682019 Tel.:+914028611/22 Mobile:+919846006580 E-mail:[email protected] Mobile:+919526065551 E-mail:[email protected] Mobile:+919656690111 E-mail:[email protected]

Durgapur6/15,BengalAmbuja (NearDurgapurCinemaHall) Citi Centre, Durgapur - 713216 Mobile:+919830317456 E-mail:[email protected] Mobile:+919051020207 E-mail:[email protected]

Nagpur5th Floor, Land Mark Building WardhaRoad,RamdasPeth Nagpur-440010 (:+917123093000Fax:+917123093111

PuneTowerB/701-705,ICCTradeTower 403A, Senapati Bapat Road Pune - 411016 (:+912030466000Fax:+912030466060

Vishakhapatnam2nd Floor, 30-8-47 LakshmiNarasimhaTowers Banu Street, Daba Gardens Visakhapatnam - 530 020 Andhra Pradesh (:+918913050200Fax:+918913050222

Rudrapur FlatNo.202,TowerIndus‘B’ Omaxe Reviera Ltd. Rudrapur - 263153, Uttarakhand Mobile:+919918002525 E-mail:[email protected]

Rudrapur FlatNo.104,TowerRhone‘C’ Omaxe Reviera Ltd. Rudrapur - 263153, Uttarakhand Mobile:+919621070111 E-mail:[email protected]

Salem Rajagiragham,LumbiniIllam,No.20 PalaniappaNagarHasthampatti Salem - 636007 Mobile:+918754922245 E-mail:[email protected]

Siliguri C/o.RadhagobindoPaul Syed Mustafa Ali Road Raja Rammohan Roy Road, Hakimpara WardNumber:XV,Dist-Darjeeling Siliguri - 741201 Mobile:+919932276294 E-mail:[email protected]

Sonepat H.No.1103,1stFloor,Sector-14 Sonepat, Haryana - 131001 Mobile:+919855526122 E-mail:[email protected]

Sriperumbudur C-32Block,3rdFloor,FlatNo.31 TVHSvayaApartments,Nr.VengaduVillage KundrathurRoad,Sriperumbudur-602105 Mobile:+919884102638 E-mail:[email protected]

Surat 3/A,NavrachanaSociety,Opp.D.K.Park BhatarRoad,Surat-395001 Mobile:+919879510191 E-mail:[email protected]

Surat A-604, Stuti Universal, Green City Road Pal-Adajan,Surat-395009,Gujarat Mobile:+919712445504 E-mail:[email protected]

Trichy Mobile:+918056025127 E-mail:[email protected]

TrivandrumHouseNo.30,GangaNilayam SwathyNagar,Kazhakuttom Trivandrum-695582 Mobile:+919947957839 E-mail:[email protected]

Udaipur A-39,NewAhinsapuri,Fatehpura Udaipur - 313004 Mobile:+919983691888 E-mail:[email protected]

Ujjain TirupatiHights,B-Block,FlatNo.206 NanaKheda,Ujjain-IndoreRoad Ujjain-456010(MP) Mobile:+918889911401 E-mail:[email protected]

Vapi FlatNo.201,GayatriBuilding NearJalaramTemple,NH8 Vapi,DistrictValsad-396195 Mobile:+919687668690 E-mail:[email protected]

Vapi FlatNo.302,3rdFloor,Samrajya-IV Royal Residency, Gokul Vihar Township Charwada Road, Taluka- Pardi, Dist. Valsad Vapi-396195 Mobile:+919825147957 E-mail:[email protected]

Vijayawada LaxmiNivas,1stFloor,FlatNo.FF2 44/3&44/2,PlotNo.08 SundarayyaNagar,Payakapuram Vijayawada - 520015, Andhra Pradesh Mobile:+919642351144 E-mail:[email protected]