+ All Categories
Home > Documents > Our Ref: CMD-Ill/16~. 15100 (3'-1) - bis.gov.in · Amendment No.3 May 2007.to IS 15100:2001 Multi...

Our Ref: CMD-Ill/16~. 15100 (3'-1) - bis.gov.in · Amendment No.3 May 2007.to IS 15100:2001 Multi...

Date post: 02-Jan-2019
Category:
Upload: vannguyet
View: 214 times
Download: 0 times
Share this document with a friend
3
[ , ~ .... , v #. "- ,. . ~ ,(' I . ~, d .;r'!'! v Jo.~ ;.;; a. . .J 6'~ ~ : ~d ~ ,5- ~. :s ~ r ~ , o! . i -~ ..' -r:... . "" -,:, F. 'E " ,-~.,"==~ , BUREAU'OF INDIAN STANDARDS (Central Marks Department - III) 2~ AUG ~ 14 August 2007 Our Ref: CMD-Ill/16~. 15100 (3'-1) ~ Subject: Implementation Of Amendment No.3 May 2007 to IS 15fOO:2001 Multi ~ Function Valve ;\ssembly for Permanently Fixed Liquefi~ed Petroleum Gas (LPG) Contain,ers for Autonrotive Use and revised STI Doc:STI/15!00/4 November, 2007. / Amendment No.3 May 2007.to IS 15100:2001 Multi Function Valve Assembly for /' Permanently Fixed J,iquefied Petroleum Gas (LPG) Containers for Automotive Use - has been published (copy. enclosed). As per this Amendment, Bon Fire Test has been added in clause 8.3 of IS 15100- A multifunction valve shall be subjected to Bon-fire test as per procedure given in Cl. 10.6.1 oflS14899. The draft revised" STI was circulated vide GMD Note of even number ,dated 27 June, ~ 2007 for seeking comments of ROs/BOs. However, no comments were received. Accordingly, STI has been revised as Doc:STI/15100/4 November, 2007 ( copy of STI available on BI~ Intranet). It ha~ been decided to implement above Amendment with efIeet from Ist. November, 2007. ROsl BOs are requested to inform the licensees under their jurisdiction about implementation of above amendment along with revised STI with effect from 1 st November ,2007. Bon fire test had been conducted while considering grant of lic.encefor IS 15100:2001 by CCOE before giving no objection Certificate. Endorsement of Implementation of Amendment No 3 and revised STI to be~"'made in the llcence after confirmation from' licensee regardLng"oarrangementmade for conducting the Bone-fire test as prescd'i)ed-Tn~- the revised-S"n~and BO to ensure'tompliance of the same at the frequency stipulated in the revised STI. .> 'c -Y. c c::;-' 6\~~ ( NawfH-Kishore) Sc B (CMD-III) - '" Encl : as above " Sc F&f{(CMD~iiI ) (o---~---- DDGM~ ((~v~,~~ ~ ~ ~ :; RO:IBOSIBI~; ~, - .Cc: CMD-l MED. for a'" . . . . rrangmg Gazette notification \ "" ~ " ~ '" ._~.~"'" ~ -, :. ~
Transcript

[

,~

....,v#. "-

,. . ~

,('

I .

~, d.;r'!'!v Jo.~

;.;; a.. .J6'~~ :~ d~ ,5-

~.:s ~r ~

, o!. i-~..' -r:.... ""

-,:,F.

'E

",-~.,"==~

,

BUREAU'OF INDIAN STANDARDS(Central Marks Department -III)

2 ~ AUG~14 August 2007Our Ref: CMD-Ill/16~. 15100 (3'-1)

~

Subject: Implementation Of Amendment No.3 May 2007 to IS 15fOO:2001 Multi~

Function Valve ;\ssembly for Permanently Fixed Liquefi~ed Petroleum Gas (LPG)Contain,ers for Autonrotive Use and revised STI Doc:STI/15!00/4 November, 2007.

/

Amendment No.3 May 2007.to IS 15100:2001 Multi Function Valve Assembly for/'

Permanently Fixed J,iquefied Petroleum Gas (LPG) Containers for Automotive Use-has been published (copy.enclosed). As per this Amendment, Bon Fire Test has beenadded in clause 8.3 of IS 15100- A multifunction valve shall be subjected to Bon-firetest as per procedure given in Cl. 10.6.1 oflS14899.The draft revised"STI was circulated vide GMD Note of even number ,dated 27 June, ~

2007 for seeking comments of ROs/BOs. However, no comments were received.Accordingly, STI has been revised as Doc:STI/15100/4 November, 2007 ( copy of STIavailable on BI~ Intranet).

It ha~ been decided to implement above Amendment with efIeet from Ist.

November, 2007. ROsl BOs are requested to inform the licensees under their jurisdictionabout implementation of above amendment along with revised STI with effect from 1st

November ,2007.

Bon fire test had been conducted while considering grant of lic.encefor IS 15100:2001 byCCOE before giving no objection Certificate. Endorsement of Implementation ofAmendment No 3 and revised STI to be~"'madein the llcence after confirmation from'

licensee regardLng"oarrangementmade for conducting the Bone-fire test as prescd'i)ed-Tn~-the revised-S"n~and BO to ensure'tompliance of the same at the frequency stipulated inthe revised STI.

.>'c

-Y.

c c::;-'

6\~~( NawfH-Kishore)

Sc B (CMD-III)-

'"

Encl : as above "

Sc F&f{(CMD~iiI ) (o---~----DDGM~ ((~v~,~~~ ~ ~

:;RO:IBOSIBI~; ~, -.Cc: CMD-lMED. for a'" . .

. . rrangmg Gazette notification

\""

~

" ~

'"

._~.~"'"~

-,:.

~

-'h::J..- ,&-'';:--

A!\IE:"DMENT NO. J !\IAY 2007TO

IS 15100: 20(H MULTI FUNCTION VALVEASSEMBLY FOR PERMANENTLY FIXED

LIQUEFIED PETROLEUM GAS (LPG) CONTAINERSFOR AUTOMOTIVE USE

(Page 1. clause 3.1.3.1.jl/'st sentence) - Substitute the following for theexisting:

.A valve normally in the open position which closes automatically whendifferential pressure across the valve is not more than 0.1 MPa.'

(Page 1, clause 3.1.3.3) - Substitute the following for the existing clause:

'When the excess flow check valve is in cut-off position, the liquid flow throughthe equalizing device shall not exceed 500 cm3/min at a differential pressure of0.7 MPa for valves suitable for liquid withdrawal.'

[Page 6, clause 5.5.2 (see also Amendment No.1)] - Substitute thefollowing for the existing:

'The multifunction valve inlet shall have parallel male (external) threads of sizeM 12x 1.5 or equivalent approved by statutory authority.'

(Page 6, clause 8.2) - Insert the following new clause after 8.2:

'8.3 Bon-Fire Test - A multifunction valve shall be subjected !Obon-fire testas per procedure given in 10.6.1 of IS 14899.'

~. ,(Page 9, clause 9.8.1.3.7, last sentence) - Substitute the following for the

~.~ eXlstmg:~

, "The pressure valve under test shall be connected either to the discharge end of

?: the flow meter or upstream side of the flow meter. 'wW"

~., ,<i.;>r 'A nlye intended for use only with liquid shall be tested with water and valve~' ,.~ ~intended for use with vapour shall be tested with air.'

{).f'\\ '~.~il:,

/ \,t"'":J"" .......

'1\\'

(Page 10, clause 9.8.2.2, second sentence) - Substitute the foliowlllg forthe existing:

\f

Amend No.3 to IS 15100 : 2001

(Page 12, dllllse 9.10.1, third IllIe) - Substitute 'after'ji)!" 'and aftci

(Page 12, dal/se 9.10.2, third iiI/c) - Substitute 'after' fiH 'and after',

(Page 12, clause 9.10.3, third line) - Substitute 'after'jor 'and after',

(Page 13,Annex A) - Insert the following at the appropriate place:

14899 : 2000 Multifunction valve assembly for permanently fixed liquefiedpetroleum gas (LPG) containers for automotive use

(ME 16)