Specification: 18 January 2018 955 Industrial Road San Carlos, CA 94070 USA Tel +1 (650) 802-8292 Fax +1 (650) 802-8298 [email protected] www.gmw.com 1 OVERVIEW The 5405 dipole electromagnet is a fit, form and function upgrade for the 5403 electromagnet system. This upgrade provides approximately 40% more field for a given pole gap. The 5405 is shipped with a standard set of poles that optimize maximum field but several pole options are available. GMW can also design custom poles that achieve a specific performance. Poles are interchangeable and are available with an axial access bore. FEATURES Intermediate weight at 155kg Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap Any mounting orientation Fast cycle times APPLICATIONS EPR FMR MOKE
Transcript
Page 1: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

1

OVERVIEW

The 5405 dipole electromagnet is a fit, form and function upgrade for the 5403 electromagnet system. This upgrade provides approximately 40% more field for a given pole gap.

The 5405 is shipped with a standard set of poles that optimize maximum field but several pole options are available. GMW can also design custom poles that achieve a specific performance. Poles are interchangeable and are available with an axial access bore.

FEATURES

• Intermediate weight at 155kg

• Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap

• Any mounting orientation

• Fast cycle times

APPLICATIONS

• EPR

• FMR

• MOKE

Page 2: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

2

MODEL 5405 GENERAL SPECIFICATIONS

Dimensions 600mm W x 322mm D x 355mm H (23.62 inch w x 12.68 inch D x 13.98 inch H) Weight (excluding hoses and water) 155 kg (342 pounds) Standard Pole Face Diameters 3mm, 10mm, 38mm and 76mm

Pa

rallel

Serie

s/Parallel

Serie

s

Resistance (20°C) 0.21 0.84 3.36 Max. Resistance (70°C) 0.26 1.01 4.04 Max. continuous current 140 70 35 A Peak Current (sinusoid) 200 100 50 A Peak Current (triangle wave) 240 120 60 A Max. continuous Power 6.0 6.0 6.0 kW Max Instantaneous Power 18.0 18.0 18.0 kW Self Inductance 70 278 1115 mH Water Cooling (supply 18°C @ 15 psi) 4 4 4 lpm 3 dB frequency point 10 10 10 Hz Primary Over Temperature Interlock 70 70 70 °C Secondary Temperature Circuit* Custom

* The secondary temperature circuit is mounted on the coils in the same location as the primary circuit. While the

primary circuit protects the coils from thermal damage, the secondary circuit can be used to provide early

identification of above normal operating temperature. This may provide a yellow alert indicating that the system is

within acceptable operating parameters but that some maintenance may be required.

Page 3: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

3

Figure 1: Comparison of performance between 5403 and 5405 for standard poles. The data reflects the performance of both magnets operating at peak continuous current with coils at maximum spacing.

Page 4: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

4

Page 5: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

5

Page 6: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

6

Page 7: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

7

Page 8: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

8

Page 9: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

9

Page 10: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

10

Page 11: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

11

Page 12: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

12

Percentage of Peak Performance Achieved for Various Power Supplies

Page 13: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

13

Overbar Option

The 5405 includes the option of an overbar configuration. In this configuration, the magnet provides slightly increased field and greatly increased field uniformity in the working region. Note the Ø40mm bore in the overbar. This facilitates the integration of the magnet with a 1½” cryostat.

Page 14: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

14

Vertical Mounting Bracket

Page 15: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

15

45° Mounting Bracket

Page 16: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

16

90° Mounting Bracket

Page 17: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

17

Flow Meter Option

PF3W520-N03-1T-RA-X143_PF3W

It is often important to be able to identify variations from normal operating

procedure. One method for achieving this is to include a flow meter in the

return water line. This can present a yellow alert that indicates the system is

still operating within acceptable parameters but the system requires attention.

This is critical for continuous duty applications.

Page 18: OVERVIEW - gmw.com · Tel +1 (650) 802-8292 Fax +1 (650) ... PF3W520-N03-1T-RA-X143_PF3W It is often important to be able to identify variations from normal operating

Specification: 18 January 2018

● 955 Industrial Road ● San Carlos, CA 94070 ● USA

Tel +1 (650) 802-8292 ● Fax +1 (650) 802-8298 ● [email protected] ● www.gmw.com

18

Thermocouple Option

TSM1-KG-0363B

For process control a mounting point is provided on each of the four coils that

make up the conducting circuit. Thermocouples may be mounted on some or all

of these coils to make sure that the magnet system is continually monitored for

out-of-normal operation.


Recommended