Owner Installation Manual for AW631, 831, 1231, 1531 AIR/WATER HEAT PUMPS (SD526750 Issue 10) 04/11/08
Transcript
Page 1: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 1

Owner InstallationManual for

AW631, 831, 1231, 1531AIR/WATER HEAT PUMPS

(SD526750 Issue 10)04/11/08

Page 2: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater
Page 3: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 2

Contents

AIR/WATER HEAT PUMPS FOR SWIMMING POOLS .................................................................................... 3

HOW THE HEAT PUMP WORKS .................................................................................................................... 4

INSTALLATION ............................................................................................................................................... 5

1.SITING ......................................................................................................................................................... 5

2.AIR FLOW .................................................................................................................................................... 6

3.PLUMBING ................................................................................................................................................... 7

RECOMMENDED PLUMBING SCHEMATIC .................................................................................................... 9

4. DETERMINING WATER FLOW ...................................................................................................................10

5.ELECTRICAL (MACHINE WIRING AND SUPPLY). ..................................................................................... 11

ELECTRICAL CIRCUIT DIAGRAMS ...............................................................................................................17

CONTROLS AND INDICATION LAMPS .........................................................................................................19

HEAT PUMP MALFUNCTION .........................................................................................................................20

DATA SHEET ..................................................................................................................................................21

INSTALLATION DRAWINGS ..........................................................................................................................23

WINTERISING PROCEDURE .........................................................................................................................27

START UP PROCEDURE AFTER WINTERISATION.......................................................................................28

WARRANTY CONDITIONS. ............................................................................................................................29

CONTACTING CALOREX ...............................................................................................................................30

Page 4: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater
Page 5: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 3

AIR/WATER HEAT PUMPS FOR SWIMMING POOLS

MODELS AW631, 831,1231, 1531

The Calorex ‘31’ range of air/water heat pumps is for swimming pool applications and consistsof 4 models. Heat pumps in this manual are designed to heat pool water and spas within therange of 10°C to 40°C. Standard units are suitable for outdoor pools operating in ambienttemperatures from 7°C to 40°C. Reverse Cycle Defrost models are available with operationdown to -15ºC, these machines are suitable for heating indoor pools or spas all year round.The water heat exchanger is a full flow type, manufactured from titanium, which is a highlycorrosion resistant material. The heat pumps are suitable for use in fresh water and saltwater pools.The compressors fitted in the heat pumps are the scroll type and are known forquiet running. With these features the heat pump is designed to have a long, trouble free life.

All units have integral safety devices to protect the heat pump from internal and externalfaults. Indicator lamps indicate operating mode. An adjustable digital thermostat controlswater temperature. Also a 6 minute cycle time delay is incorporated.

Page 6: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 4

HOW THE HEAT PUMP WORKS

The CALOREX Swimming Pool Heat Pump provides thermodynamic heating by means of a vapourcompression cycle (similar to that employed in a conventional refrigerator), in addition to operating as an activesolar collector.

Cooled Air Exhaust Compressor

ExpansionDevice

Outside Air Evaporator(Heat Collector)

Pool Filter

SwimmingPool

Condenser Heat Tranferedto Pool Water

Pool WaterPump

Pool Water

The EVAPORATOR collects heat fromthe outside ambient air, pre-heated by thesun. With Calorex, swimming pool heatpumps high volumes of outside air aredrawn into the unit by the fan and expelledthrough the evaporator fins. The evaporatorhas liquid refrigerant passing through it,which is at a considerably lowertemperature than the ambient air, thereforethe air gives up its heat to the refrigerant,which then vaporizes.This pre-heated vapour now travels to-

The COMPRESSORwhere it is compressed andupgraded to a much highertemperature.The hot vapour now enters -

The CONDENSER where it issurrounded by the pool water. The heatis given up to the cooler pool water andthe now cooler refrigerant returns to itsformer liquid state but still under highpressure from the compressor.This pressure is released by passingthe liquid through -

The EXPANSION DEVICEand from there, now at lowpressure, it is returned to theevaporator and the cycle startsagain.

Coefficient of Performance

The efficiency of a Heat Pump is usually called its 'Coefficient of Performance' - (C.O.P.) which issimply a ratio of heat output to energy input, both being expressed in kW. Thus a Heat Pumpabsorbing 1 kW of electricity, collecting 4 kW of energy from the air, and delivering 5 kW of heat tothe pool water is said to have a C.O.P. of 5:1.

Naturally this ratio will vary according to the temperature of the water and the ambient air.

Page 7: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 5

INSTALLATION

1. SITING

a Ensure heat pump on site is as ordered, i.e. model, electrical supply and factory fitted options.

b Inspect unit for damage, in particular inspect the evaporator (finned side) to ensure that it is undamaged.(Minor indentations in the fins do not affect performance). If severely damaged, endorse delivery note inpresence of the driver and send a recorded delivery letter to transport company giving details.

c Protect unit if installation is delayed.

d Provide a firm level base capable of supporting operational weight of unit; spread load if mounted on timberfloor.

e Ensure water cannot collect under unit, it is recommend that units are installed on plinths 100mm abovefinished floor level. This also aids condensate drainage.

f Allow adequate clearance to service panels on unit; recommend 500mm minimum.

g All Calorex heat pumps are by design as quiet as is practical, however due consideration should be givento siting the heat pump in order to minimise the noise coming from the machine, for example by positioningthe machine so that the inlet/outlets are parallel to occupied premises.

h Ensure loose debris such as leaves, grass cuttings, etc will not block air inlet grilles.

i Consider protection from extreme weather conditions if installed externally, i.e. lean-to-cover or building.

Page 8: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 6

2. AIR FLOW

Due consideration must be given to air flow, i.e. do not obstruct inlet or outlet and ensure discharge air cannotre-circulate to inlet. (See figure 1)

Suitable openingSuitable opening

> 50 cm

PLANT ROOMWALL WALL

FIG 1 POSSIBLE POSITIONS OF A CALOREX 31 UNIT

SWIMMING POOL/SPA

CALOREX 31

CALO

REX

31

CALOREX 31

CALOREX 31

CALOREX 31

Note: If multiple units are installed in an enclosed area then the inlet free areas required for each unit can beadded together to form one inlet aperture. BUT discharge from each unit must be kept separate and must notbe incorporated into one common duct system.

Required Free Areas to provide air flow toand from heat pumps when installed in anenclosed area or where required to pass airthrough a wall, etc.

Free area is the available area through which aircan pass through a grille or louvres.

MODEL Inlet Discharge

AW 631 0.1648 0.114AW 831 0.2931 0.114AW 1231 0.2931 0.114AW 1531 0.3489 0.114

Minimum Free Area m²TABLE 1

Page 9: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 7

THIS TYPE OF INSTALLATION

SHOULD BE AVOIDED INCORRECT DRAINAGEFOR CONDENSATE

CORRECT DRAINAGEFOR CONDENSATE

ELBOW

'U' TRAP

ADEQUATE FALL

FIGURE 3

3. PLUMBING

a. Calorex '31' range Heat Pumps have water inlet/outlet connections as follows:

All models have 1½ " BSP parallel, male threads.

The machine is supplied with bungs fitted in the water connection fittings. These need to be removed beforethe unit is installed. See Section 4.

b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existingheater is being retained, then the Calorex Heat Pump should be connected between the filter and the otherheater. (See figure 4).

c. Suitable breakable couplings should be installed local to heat pump.

d. If the heat pump is installed at a lower level than pool water then isolation valves should be fitted.

e. Drain valve or plug should be fitted to the lower pipe to facilitate drain down in winter period.

f. Connections on all models are by BSP parallel, male threaded fittings. These should be hand tightenedonly, otherwise damage may result to the threads of the plastic fittings.

g. The condensate drain at the base of the unit collects the condensation from the evaporator fins. Thisshould be run away to waste via ¾" domestic waste piping. It is therefore necessary to ensure that theCalorex unit is placed on a level plinth so that the condensate water can run away with adequate fall towaste ie.½" per foot min and must incorporate a 'u' trap as to not overflow the edges of the drip-tray insidethe machine. See figure 3.

Page 10: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 8

h. When the pipework installation is complete the pool pump should be switched on and the system tested forleaks. Also check the filter gauge to see that there is not an excessive increase in back pressure. Ifeverything is then working normally the water circulating system is ready to use.

i. Water circuit to and from unit to be capable of maintaining within specified limits the rate of flow required byheat pump (see data sheet).

j. All pipework must be adequately supported with allowance for expansion/contraction especially with plasticpipework.

k. It is recommended that when installing water systems the last connections to be made in the systemshould be the breakable connections to avoid any stresses on to the unit connections.

IMPORTANT

1. All Pool Purifying Devices and Chemical Injection Systems to be fitted down stream of heat pumpunless installation is as per Filter dosing (See figure 4). This includes the practice of dosingchemicals direct into Skimmer Basket, which results in concentrated corrosive liquids passing overmetal components.

2. Water quality must be maintained as follows:

pH: 7.4 ± 0.4Total Alkalinity: 80 - 120 ppm as CaCo3

Total Hardness: 100 - 300 ppm as CaCo3

Total dissolved solids: Max. 3000 ppmSaline Water Maximum concentration 6% wt/wtChlorine - free Cl range 1.0 - 3.0 ppmOzone 0.8 - 1.0 ppmBromine 2 - 3 ppmBaquacil 25 - 50 ppmAquamatic Ionic Purifier Maximum 2 ppm CopperTam Pure Purifier Maximum 2 ppm CopperSherwood Purifier Maximum 2 ppm Copper

3. Maximum pressure of water in heat pump circuit should not exceed 3.5kg/cm2 (50 psi)

Page 11: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 9

KEY

ISO

LATI

ON

VA

LVE

B

RE

AKAB

LE C

OU

PLI

NG

N

ON

RET

UR

N V

ALV

E

TH

RE

E W

AY

VA

LVE

N

ON

R

ETU

RN

VA

LVE

C

HE

MIC

AL

DO

SIN

G

SAN

ITIS

ER

OR

DE

VIC

E, I

F FI

TTE

D

AU

X H

EATE

R

IF F

ITTE

D

FILT

ER

PU

MP

TO W

AST

E F

OR

W

INTE

RIS

ING

D

RA

IN D

OW

N

AN

TI R

ETU

RN

LO

OP

TO B

E IN

CO

RP

OR

ATE

D,

MIN

IMU

M H

EIG

HT

100m

m A

BO

VE H

EAT

PU

MP

OU

LET

PO

RT

(IF S

AN

ITIS

ER

FIT

TED

)

100mm

CO

ND

EN

SAT

E W

ATE

R

TO W

ASTE

SPA

RE

PO

RT

FOR

W

INTE

RIS

ING

FL

USH

ING

C

ON

NE

CTI

ON

TO W

AS

TE

CA

LOR

EX

HEA

T P

UM

P

POO

L

RECOMMENDED PLUMBING SCHEMATIC

FIG

UR

E 4

Page 12: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 10

=I6 MINS

I=

D436856 ISS 1

=0

=0

=I

6 MINSI=

FLOW LAMP ILLUMINATED,ADEQUATE FLOW

FLOW LAMP NOTILLUMINATED,INADEQUATE FLOW

POOL/SPA

PUMP

FILTER

WATER HEATING AFTER6 MINUTE DELAY

SYMBOL CHART- ALL MACHINES

REMOVE AND DISPOSEOF LABEL

4. DETERMINING WATER FLOWPlumbing.The machine must be plumbed in as shown, see diagrams below (a tear off label is attached to the machine ondelivery).Adjust the flow rate until the flow light is illuminated, giving the correct flow rate. The “adequate flow” symbollooks like this:

MACHINE SIDEAW631 AND AW831 FLOW RATE 115 LITRES PER MINUTE

AW1231 AND AW1531 FLOW RATE 160 LITRES PER MINUTE

POOLWATER IN

(REMOVE BUNGBEFORE

INSTALLINGMACHINE)

POOLWATER OUT

CONDENSATEDRAIN

MACHINE LABEL

(REMOVE BUNGSBEFORE INSTALLING

MACHINE)

Page 13: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 11

5. ELECTRICAL (MACHINE WIRING AND SUPPLY).SEE FIGURES 5,6,7 AND 8 FOR PREFERRED METHOD

Use of the Calorex Energy Management Controller will enable greater savings to be made because thecirculating pump need only run when required and this can be at a time preferred by the customer, i.e. in theEconomy 7 period.

All electrical work to be carried out in accordance with l.E.E. standards, latest issue, or local codes of practiceas applicable.

The machine should be installed in line with EMC2004/108/EC.

Protected supply to incorporate fuses (Type GU, FAZC) or motor (type C) circuit breakers to specified rating,(see Data Sheet). H.R.C. fuses are recommended. An isolator must be fitted within 2m and in sight ofmachine.†

All units must be correctly earthed-grounded. An earth leakage trip of the Current operating type (30mA) isrecommended to be fitted to all pool electrics.

INCONSISTENT ELECTRICAL SUPPLY

The following limits of operation must not be exceeded if Calorex machines are to be guaranteed either inperformance or warranty terms:

Minimum MaximumVoltageSingle phase machines 207V 253VThree-phase machines 360V 440VCycle frequency 47.5Hz 52.5Hz

N.B. This voltage must be available at the heat pump whilst running.

† Note the isolator must have a minimum of 3mm air gap when turned off.

IMPORTANT:-

The user should be made aware that on all the installations shown by figures 5, 6, 7 and8 that to work on part of the intallation the supply to all parts of the installation must beisolated.

Three phase units are fitted with a phase protection relay and will not run if phases areconnected incorrectly. A red lamp on the phase rotation relay in the electric box isilluminated when the phases are correctly connected.

Page 14: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 12

ELECTRIC BOX ACCESS

REMOVE THE 6 SCREWS FROMTOP COVER AND LIFT OFF

N

L

W ATER PRESSURE

SW ITCH

SO FT START

KIT

FAN L

FAN N

ENERGY MANAGEMENT

CO NTROL LER

WATER FL OW

SW ITCH

INTE

RLO

CKS

REVERSING

VALVE

SW ITCH

REVERSING

VALVE

' Y' VRSN

ONLY

2 4

6

1 3

5

REMOVE THE 6 SCREWS FROMSERVICE PANEL AND LIFT OFF

MAINS INBOTHENDS

1 PHASE 230V ~ 1N 50Hz

N

L

WATER PRESSURESWITCH

SOFT STARTKIT

FAN L

FAN N

ENERGY MANAGEMENTCONTROLLER

WATER FLOW

INTER

LOC

KS

SWITCH

REVERSINGVALVE

'Y' VRSNONLY

3 PHASE 400V ~ 3N 50Hz

N

L

WATER PRESSURESWITCH

SOFT STARTKIT

FAN L

FAN N

ENERGY MANAGEMENTCONTROLLER

WATER FLOWSWITCH

INTE

RLO

CKS

L L

1 3

2

REVERSING

VALVE

'Y' VRSNONLY

LOCATION OF ELECTRICAL SUPPLY CONNECTIONS IN 31 RANGE HEAT PUMP

FIGURE 5

Page 15: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 13

RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP (1Ø or 3Ø)WITH SINGLE PHASE WATER PUMP LARGER THAN ¾ H.P. AND

ENERGY MANAGEMENT CONTROLLER

L1

L2

L3

N

5

6

9

10

L

N

5

6

9

10

N L

3 4

5 6

7 8 9 10

L

N

N L

CALOREX ENERGYMANAGEMENTCONTROLLERAVAILABLE FROMCALOREX DISTRIBUTOR

SINGLE PHASESUPPLY TO SUITCAPACITY OFWATER PUMP

L N

L N L

N L

4 POLE N/O STARTER WITH OVERLOAD AND230v 50Hz COIL RATEDTO SUIT WATER PUMP

SINGLE PHASE13AMP SUPPLY 230vFUSED TO SUITWATERPUMP

SWITCHED FUSE ISOLATOR WITHIN 2m OF HEAT PUMP AND SIZED IN ACCORDANCE WITH DATA SHEET

INTERLOCK

ENERGY MANAGEMENTCONTROLLER

INTERLOCK

ENERGY MANAGEMENTCONTROLLER

SOFT STARTSOFT START

CALOREXHEAT PUMPSINGLE PHASE

WATER PUMPMAXIMIUM 3/4HPSINGLE PHASE

CALOREXHEATPUMPTHREE PHASE

VOLT FREEAUXILLARYCONTACT N/O

L1

L2

L3

N

5

6

9

10

L

N

5

6

9

10

SOFT START

INTERLOCK

CALOREXHEAT PUMPSINGLE PHASE

ENERGY MANAGEMENTCONTROLLER

N L

3 4

5 6

7 8 9 10

L

N

SINGLE PHASE13AMP SUPPLY 230vFUSED TO SUITWATERPUMP

N L

CALOREX ENERGYMANAGEMENT CONTROLLERAVAILABLE FROMCALOREX DISTRIBUTOR

SWITCHED FUSE ISOLATOR WITHIN 2m OF HEAT PUMP AND SIZED IN ACCORDANCE WITH DATA SHEET

WATER PUMPMAXIMIUM 3/4HPSINGLE PHASE

RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP (1Ø or 3Ø)WITH SINGLE PHASE WATER PUMP OF MAXIMUM ¾ H.P. AND

ENERGY MANAGEMENT CONTROLLER

INTERLOCK

ENERGY MANAGEMENTCONTROLLER

SOFT START

CALOREXHEATPUMPTHREE PHASE

FIGURE 6

FIGURE 7

Page 16: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 14

RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP (1Ø or 3Ø)WITH THREE PHASE WATER PUMP AND ENERGY MANAGEMENT CONTROLLER

L

N

5

6

9

10

SOFT START

INTERLOCK CALOREX HEAT PUMP

SINGLE PHASE

ENERGY MANAGEMENT CONTROLLER

N L

3 4 7 8 9 10

L1

L2

SINGLE PHASE 13 AMP SUPPLY 230v FUSED AT 1 AMP

N L

CALOREX ENERGYMANAGEMENT CONTROLLERAVAILABLE FROMCALOREX DISTRIBUTOR

SWITCHED FUSE ISOLATOR WITHIN 2m OF HEAT PUMP AND SIZED IN ACCORDANCE WITH DATA SHEET

WATER PUMP THREE PHASE

THREE PHASE SUPPLY TO SUIT CAPACITY OF WATER PUMP L3 L1

L3 L2 L

4 POLE N/O STARTER WITH OVERLOAD AND 230v 50Hz COIL RATED TO SUIT WATER PUMP

L1

L3

L2

N

VOLT FREEAUXILLARYCONTACT N/O

5 6 L1

L2

L3

N

5

6

9

10

SOFT START

INTERLOCK

CALOREX HEAT PUMP

THREE PHASE

ENERGY MANAGEMENT CONTROLLER

FIGURE 8

Page 17: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 15

RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP (1Ø or 3Ø)

L1

L2

L3

N

5

6

9

10

SOFT START

INTERLOCK

CALOREX HEAT PUMP

THREE PHASE

L

N

5

6

9

10

SOFT START

INTERLOCK CALOREX HEAT PUMP

SINGLE PHASE

L

N

SINGLE PHASE 13 AMP SUPPLY 230v FUSED TO SUIT WATER PUMP

N L

SWITCHED FUSE ISOLATOR WITHIN 2m OF HEAT PUMP AND SIZED IN ACCORDANCE WITH DATA SHEET

WATER PUMP MAXIMIUM 3/4 HP SINGLE PHASE

WITH SINGLE PHASE WATER PUMP OF MAXIMUM ¾ H. P(NOTE: Method shown in Fig 9. is a preferred system due to incorporated starter and interlock)

L1

L2

L3

N

5

6

9

10

SOFT START

INTERLOCK

CALOREX HEAT PUMP

THREE PHASE

L

N

5

6

9

10

SOFT START

INTERLOCK CALOREX HEAT PUMP

SINGLE PHASE

L

N

N L

SWITCHED FUSE ISOLATOR WITHIN 2m OF HEAT PUMP AND SIZED IN ACCORDANCE WITH DATA SHEET

WATER PUMP MORE THAN 3/4 HP SINGLE PHASE

SINGLE PHASE SUPPLY TO SUIT CAPACITY OF WATER PUMP

L N

L N L

N L

4 POLE N/O STARTER WITH OVERLOAD AND 230v 50Hz COIL RATED TO SUIT WATER PUMP

N

RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP(1Ø or 3Ø)WITH SINGLE PHASE WATER PUMP OF LARGER THAN ¾ H.P.

VOLT FREEAUXILLARY

CONTACT N/O

FIGURE 9

FIGURE 10

Page 18: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 16

L1

L2

L3

N

5

6

9

10

SOFT START

INTERLOCK

CALOREX HEAT PUMP

THREE PHASE

L1

N

5

6

9

10

SOFT START

INTERLOCK CALOREX HEAT PUMP

SINGLE PHASE

L1

L2

N L

SWITCHED FUSE ISOLATED WITHIN 2m OF HEAT PUMP AND SIZED IN ACCORDANCE WITH DATA SHEET

WATER PUMP THREE PHASE

THREE PHASE SUPPLY TO SUIT CAPACITY OF WATER PUMP

L3 L3

L3 L2 L

4 POLE N/O STARTER WITH OVERLOAD AND 230v 50Hz COIL RATED TO SUIT WATER PUMP

L1

L3

L2

N

RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP(1Ø or 3Ø)WITH THREE PHASE WATER PUMP

VOLT FREEAUXILLARYCONTACT N/O

FIGURE 11

Page 19: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 17

AW631, 831, 1231 AL SINGLE PHASE (230V ~ 1 N 50Hz)

AW 631, 831, 1231 1531BL THREE PHASE ( 400V ~ 3 N 50Hz)

LIV

E

NEU

TRAL

WAT

ER

FLO

W

SW

ITC

H

87

CO

MP

RES

SOR

W (C

)

V(S)

U(R

)

DEL

AY

TIM

ER

HP

SW

ITC

H

CO

NTR

OL

FUSE

FAU

LT

LIG

HT

MA

INS

LIG

HT

RU

N C

AP

DEF

RO

ST

FAN

SO

FT

STA

RT

IF

FITT

ED

CO

NTA

CTO

R

SO

FT S

TAR

T TH

ER

MA

L O

VER

LOA

D

& FA

ULT

LI

GH

T

REL

AY/H

ARD

ST

ART

CAP

(IF

FIT

TED

)

IF F

ITTE

D

LP

SW

ITC

H

5 6

DE

FRO

ST

STA

T LI

GH

T

TER

MIN

AL

BLO

CK HO

UR

SR

UN

MET

ERIF

FIT

TED

SEN

SOR

4 62

111

10P

OO

L ST

AT

INTE

RLO

CK

TE

RM

INAL

S

74

AB

9 10

WAT

ER

PRES

SUR

E

SWIT

CH

(IF F

ITTE

D)

N L

SM

ART

CLO

CK

FEED

TER

MIN

ALS

FAN

CAP

ACIT

OR

WAT

ER F

LOW

LI

GH

T

R1

WAT

ER

FLO

W

LIG

HT

WAT

ER F

LOW

SWIT

CH

CO

NTR

OL

MO

TOR

STA

RTE

RPH

ASE

RO

TATI

ON

REL

AY

L1L2L3

1114

7 8

6 4

5 3 12

R1 74

AB

CO

MPR

ESSO

R

DE

LAY

TIM

ER

HP

SWIT

CH

FAU

LTLI

GH

T MAI

NS

LIG

HT

PO

OL

STAT

FAN

L1

NEU

TRAL

CO

NTA

CTO

R

SO

FT S

TAR

T TH

ERM

AL

OVE

RLO

AD &

FA

ULT

LIG

HT

IF F

ITTE

D

SOFT

S

TAR

T IF

FI

TTE

D

LP

SWIT

CH

INTE

RLO

CK

TE

RM

INAL

S

DE

FRO

ST

STA

T D

EFR

OST

LI

GH

T

TER

MIN

AL

BLO

CK

L2

L3

FAN

CAP

AC

ITO

R

HO

UR

SR

UN

ME

TER

IF F

ITTE

D

SE

NSO

R

4 62

111

10

5 6 9 10

N L

SMAR

T C

LOC

KFE

ED

TE

RM

INA

LS

WAT

ERP

RES

SUR

E SW

ITC

H(IF

FIT

TED

)

U(R

)

V(S)W

(C)

ELECTRICAL CIRCUIT DIAGRAMS

Page 20: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 18

AW631, 831, 1231 ALY SINGLE PHASE (230V ~ 1 N 50Hz)

AW 631, 831, 1231 1531BLY THREE PHASE ( 400V ~ 3 N 50Hz)

LIV

E

DEF

RO

ST

CO

NTR

OL

STA

T

1 4

2 3

NEU

TRAL

WAT

ER F

LOW

LI

GH

T

WAT

ER

FLO

W

SW

ITC

H

87

CO

MP

RES

SO

R

C[W

]

S [V

] R

[U]

DEL

AY

TIM

ER

HP

S

WIT

CH

CO

NTR

OL

FUS

E

FAU

LT

LIG

HT

MAI

NS

LIG

HT R

UN

CAP

STA

RT

CAP

DEF

RO

ST FA

N

SOFT

ST

ART

CO

NTA

CTO

R

SOFT

STA

RT

THER

MA

L O

VER

LOAD

&

FAU

LT

LIG

HT

REL

AY/H

ARD

(IF F

ITTE

D)

IF

FITT

ED

IF F

ITTE

D

LP

SW

ITC

H

5 6

LIG

HT

TER

MIN

AL

BLO

CK HO

UR

SR

UN

MET

ER

IF F

ITTE

D

SE

NS

OR

4 62

111

10PO

OL

STA

T

INTE

RLO

CK

TE

RM

INA

LS

R1

74

AB

9 10

WA

TER

PR

ES

SUR

E S

WIT

CH

(IF F

ITTE

D)

N L

SM

AR

T C

LOC

KFE

ED

TE

RM

INA

LS

REV

ER

SIN

G V

ALVE

DE

FRO

ST

CO

NTR

OL

STAT

1 4

2 3

LIG

HT

WAT

ER F

LOW

WAT

ER

FLO

WSW

ITC

H

CO

NTR

OL

MO

TOR

STAR

TER

PHA

SE R

OTA

TIO

N

R

ELA

Y

L1L2L3

1114

7 8

56

34

12

R1

74

ABCO

MPR

ESS

OR

C(W

)

S(V)

R(U

)

DE

LAY

TIM

ER

HP

SW

ITC

H

FAU

LT

LIG

HT M

AIN

S L

IGH

T

POO

L ST

AT

FAN

SOFT

ST

ART

L1

NEU

TRAL

CO

NTA

CTO

R

SOFT

STA

RT

THER

MAL

O

VER

LOAD

&

FAU

LT

LIG

HT

IF

FITT

ED

IF F

ITTE

D

LP

SW

ITC

H

INTE

RLO

CK

TER

MIN

ALS

5 6

TER

MIN

AL

BLO

CK

L2

L3

FAN

CAP

ACIT

OR

HO

UR

SR

UN

M

ETE

RIF

FIT

TED

SEN

SO

R

4 62

111

10

POO

L PU

MP

9 10

N L

SM

ART

CLO

CK

FEE

D T

ER

MIN

ALS

DE

FRO

ST

LIG

HT

RE

VER

SIN

G V

ALV

E

Page 21: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 19

U

P

CONTROLS AND INDICATION LAMPS

THERMOSTATAdjustable digital thermostat, controls pool water temperature at the required level.

Press and release key ‘P’ to display required temperature, to alter required temperature press up or downsymbols. After 5 seconds display will revert to actual water temperature.

INDICATOR LAMPS "AW" POOL HEATERS

MAINS RED Electrical supply on

FAULT AMBER Internal or external fault condition

DEFROST WHITE Defrost Mode

WATER FLOW GREEN Water flowing at adequate rate

CONSOLE LABEL

NON FUNCTIONAL ON THIS APPLICATION

INCREASE SET POINT

DECREASE SET POINT

ACCESS SET POINT

Page 22: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 20

HEAT PUMP MALFUNCTIONWARNING: Isolate machine electrically before entering machine or removing panels.

The user check list should be carried out before initiating a service call.

Do not attempt to interfere with any internal control settings as these have been factory calibrated and sealed.

If in doubt or if advice required contact Calorex Service Department.

Telephone (01621) 857171 or 856611

USER CHECK LISTACTION

MAINS RED OFF

FAULT AMBER OFF Check mains supply- external fuses - isolator etc.

DEFROST WHITE OFF

WATER FLOW GREEN OFF

MAINS RED ON

FAULT AMBER OFF Water flow inadequate

DEFROST WHITE OFF

WATER FLOW GREEN OFF

MAINS RED ONFirst check water flow, then

FAULT AMBER OFF Check unit control fuse on single phase machine. Check MCB on three phase machine.

DEFROST WHITE OFF

WATER FLOW GREEN OFF

MAINS RED ON Check water and air flows are not restricted.

FAULT AMBER ON Check thermal cut out on Soft Start if fitted and that air flow is not restricted. Check unit control fuse on

DEFROST WHITE OFF single phase machine. Check MCB on three phase machine.

WATER FLOW GREEN OFF

MAINS RED ON Unit on defrost (heating mode) check that air temperature is not below 7°C.

FAULT AMBER OFF Check evaporator is clean.

DEFROST WHITE ON

WATER FLOW GREEN ON

MAINS RED ON Check water and air flows are not restricted, and that electrical supply is adequate.

FAULT AMBER ON/OFF Check gas charge and airflow to machine.

DEFROST WHITE OFF

WATER FLOW GREEN OFF

UNIT DOES NOT OPERATE

FAN ON COMPRESSOR OFF

UNIT OPERATES INTERMITTENTLY

LAMP

Page 23: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 21

For Accurate Application Sizing Consult CALOREX Heat Pumps Ltd.

NOTES:-1) Weight and dimensions nett2) Performance design Iimitations Ambient = 7°C min, 40°C max Water = 10°C min, 40°C max3) Pool water to have correct balance, pH 7.4 ± 0.4 Free Chlorine 1.0 - 3.0 ppm4) Allow 500mm clearance to service panels5) Calorex reserve the right to change or modify models without prior notice.6) R407c Global warming potential (GWP) 1700.1mm WG = 9.8 Pa1m hd = 1.4 psi1L/min = 0.22 gall/min

HEAT PUMPS FOR OUTDOOR POOLSSUMMER SEASON (AL, BL)

MODEL Units AW631 AW831 AW1231 AW1531

HEAT TO POOL WATERAMBIENT 10°C, WATER 24°C kWhr 7.2 9.9 12.4 17.7AMBIENT 20°C, WATER 24°C kWhr 9.2 12.5 15.6 22.4

ELECTRICITYELECTRICAL SUPPLY 1 PHASE 230V/~1N/ 50HzELECTRICAL SUPPLY 3 PHASETOTAL POWER CONSUMEDAMBIENT 10°C, WATER 24°C kWhr 1.8 2.3 3.1 4.2AMBIENT 20°C, WATER 24°C kWhr 2.0 2.5 3.3 4.3MIN SUPPLY CAPACITY (Max F.L.A.) 1 ph N:- A 14.3 17.4 19.0 N/AMIN SUPPLY CAPACITY (Max F.L.A.) 3 ph N:- A 6.0 6.2 8.0 13.0MAX SUPPLY FUSE 1 ph N:- A 20.0 25.0 30.0 N/AMAX SUPPLY FUSE 3 ph N:- A 10.0 10.0 15.0 18.0

WATER FLOWS ETCPOOL WATER FLOW RATE:- l/mn 115 115 160 160POOL WATER PRESSURE DROP (@ Rated Flow):- m hd 1.1 1.1 2.9 2.9MAX WORKING PRESSURE POOL WATER:- bar 3.5 3.5 3.5 3.5POOL WATER CONNECTIONS:- inches 1 1/2" BSPM 1 1/2" BSPM 1 1/2" BSPM 1 1/2" BSPMCONDENSATE DRAIN CONNECTIONS:- inches 3/4"BSPM STUD 3/4"BSPM STUD 3/4"BSPM STUD 3/4"BSPM STUD

COMPRESSORNOMINAL POWER CONSUMED kWhr 1.8 2.14 2.6 3.8L.R.A. 1 ph N:- A 66 63 100 N/AR.L.A. 1 ph N:- A 11.4 14 16.6 N/ASOFT START AMPS 1 ph N:- A 29 31 35 N/A L.R.A. 3 ph N:- A 32 30 48 48R.L.A. 3 ph N:- A 4 4.7 7.3 10SOFT START AMPS 3 ph N:- A 14 14 17 25

MAIN FANAIR FLOW (Anemometer @ air on grille. Wet evaporator):- m³/hr 1800 2700 3000 4700MAX EXTERNAL STATIC PRESSURE:- mm Wg 0 0 0 0F.L.A. 1 ph N:- A 0.7 0.7 0.97 2

GENERAL DATAHERMETIC SYSTEMGAS CHARGE R407c kg 1.6 2.05 2.2 2.45

PHYSICAL DIMENSIONSWIDTH (Unpacked):- mm 1076 1076 1076 1200DEPTH (Unpacked):- mm 485 485 485 485HEIGHT (Unpacked):- mm 1255 1255 1355 1355WEIGHT (Unpacked):- kg 126 134 144 158

400V/~3N/ 50Hz

DATA SHEET

Page 24: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 22

HEAT PUMPS FOR OUTDOOR POOLSREVERSE CYCLE DEFROST (ALY, BLY)

MODEL Units AW631 AW831 AW1231 AW1531

HEAT TO POOL WATERAMBIENT 10°C, WATER 24°C :- kWhr 7.2 9.9 12.4 17.7

ELECTRICALELECTRICAL SUPPLY 1 PHASEELECTRICAL SUPPLY 3 PHASETOTAL POWER CONSUMED:-AMBIENT 10°C, WATER 24°C :- kWhr 1.8 2.3 3.1 4.2AMBIENT 20°C, WATER 24°C :- kWhr 2.0 2.5 3.3 4.3MIN SUPPLY CAPACITY (Max F.L.A.) 1 ph N:- amps 14.3 17.4 19.0 N/AMIN SUPPLY CAPACITY (Max F.L.A.) 3 ph N:- amps 6.0 6.2 8.0 13.0MAX' SUPPLY FUSE 1 ph N:- amps 20.0 25.0 30.0 N/AMAX' SUPPLY FUSE 3 ph N:- amps 10.0 10.0 15.0 18.0

WATER FLOWS ETCPOOL WATER FLOW RATE:- litres/min 115 115 160 160POOL WATER PRESSURE DROP (@ Rated Flow):- metres hd 1.0 1.0 2.0 2.0MAX WORKING PRESSURE POOL WATER:- bar 3.5 3.5 3.5 3.5POOL WATER CONNECTIONS:- inches 1 1/2" BSPM 1 1/2" BSPM 1 1/2" BSPM 1 1/2" BSPMCONDENSATE DRAIN CONNECTIONS:- inches 3/4" BSPM STUD 3/4" BSPM STUD 3/4" BSPM STUD 3/4" BSPM STUD

COMPRESSORNOMINAL POWER CONSUMED:- kWhr 1.8 2.14 2.6 3.8LRA.- 1 ph N:- amps 66 63 100 N/ARLA:- 1 ph N:- amps 11.4 14 16.6 N/ASOFT START AMPS 1 ph N:- amps 29 31 35 N/A LRA:- 3ph N:- amps 32 30 48 48RLA: -3 ph N:- amps 4 4.65 7.3 10SOFT START AMPS 3 ph N:- amps 14 14 17 25

MAlN FANAIR FLOW (Anemometer @ air on grille. Wet evaporator):- m³/hr 1800 2700 3000 4700MAX EXTERNAL STATIC PRESSURE :- mm Wg 0 0 0 0FLA:- 1 ph N:- amps 0.7 0.7 0.97 2

GENERAL DATAHERMETIC SYSTEMGAS CHARGE R407c kg 2.31 3.0 4.5 4.5

PHYSICAL DIMENSIONSWIDTH (Un-packed):- mm 1076 1076 1076 1200DEPTH (Un-packed):- mm 485 485 485 485HEIGHT (Un-packed):- mm 1255 1255 1355 1355WEIGHT (Un-packed) :- kg 133 142 157 170

230V/~1N/50Hz400V/~3N/50Hz

For Accurate Application Sizing Consult CALOREX Heat Pumps Ltd.

NOTES:1) Weight and dimensions nett2) Performance design IimitationsAmbient = -15°C min, 35°C maxWater = 10°C min, 40°C max3) Pool water to have correct balance, pH 7.4 ± 0.4 Free Chlorine 1.0 - 3.0 ppm4) Allow 500mm clearance to service panels5) Calorex reserve the right to change or modify models without prior notice.6) R407c Global Warming Potential (GWP) 1700.1mm WG = 9.8 Pa1m hd = 1.4 psi1L/min = 0.22 gall/min

Page 25: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 23

INSTALLATION DRAWINGS

1025

.00

1245.00

603.

00

954.00

DIA

472

.00

AIR

ON

AIR

OFF

485.

00

719.00

184.00479.00

110.

00

350.

00

400.

00

WA

TER

OU

T

WA

TER

INC

ON

DE

NS

ATE

MAI

NS

IN

PO

SIT

ION

CO

NS

OLE

191.

0050

5.00

716.00501.00

65.0

0

ALT

ER

NA

TIV

E

MAI

NS

IN

PO

SITI

ON

4 H

OLE

S Ø

8,6

TO

SE

CU

RE

U

NIT

TO

TH

E G

RO

UN

D19

0.00

816.

00

30.00

450.00

*

**

*

AW

631

WAT

ER IN

/OU

T 1

1/2”

BSP

M S

TUBS

CO

ND

ENSA

TE 3

/4” B

SPM

Page 26: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 24

1025

.00

1245.00

603.

00

954.00

DIA

472

.00

AIR

ON

AIR

OFF

485.

00

719.00

184.00479.00

110.

00

350.

00

400.

00

WA

TER

OU

T

WAT

ER

IN

CO

ND

EN

SATE

MA

INS

IN

POS

ITIO

N

CO

NS

OLE

4 H

OLE

S D

IA 8

.6 T

O S

EC

UR

E

MAC

HIN

E T

O T

HE

GR

OU

ND

.19

0.00

816.

00

30.00

450.00

*

**

*

95.0

0

807.

00

665.00552.00

65.0

0

ALT

ERN

ATIV

EM

AIN

S IN

P

OSI

TIO

N

AW

831

WAT

ER IN

/OU

T 1

1/2”

BSP

M S

TUBS

CO

ND

ENSA

TE 3

/4” B

SPM

Page 27: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 25

1025

.00

1345.00

1028.89

558.

90

472.

00

AIR

ON

AIR

OFF

ALT

ER

NAT

IVE

M

AIN

S IN

PO

SIT

ION

65.0

0 95.0

0

820.

00

762.00553.00

4 H

OLE

S D

IA 8

.6 T

O S

EC

UR

E

MA

CH

INE

TO

TH

E G

RO

UN

D

190.

00

816.

00

30.00

450.00

*

**

*

CO

ND

ENS

ATE

WA

TER

INWA

TER

OU

T

CO

NS

OLE

MAI

NS

INP

OSI

TIO

N

485.

00

816.00

662.00496.00

181.00

110.

0035

5.00

401.

00

AW

1231

WAT

ER IN

/OU

T 1

1/2”

BSP

M S

TUBS

CO

ND

ENSA

TE 3

/4” B

SPM

Page 28: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 26

CO

ND

EN

SA

TE

4 H

OLE

S D

IA 8

.6 T

O S

EC

UR

E M

ACH

INE

TO

TH

E G

RO

UN

D

240.

00**

30.00

450.00

880.

00

**

1033.00

567.

00

DIA

472

.00

1115

.00

1345.00

ALT

ER

NAT

IVE

M

AIN

S IN

PO

SIT

ION

AIR

ON

AIR

OFF

65.0

0 104.

0090

9.00

762.00553.00

WAT

ER

IN

WAT

ER

O

UT

CO

NS

OLE

MA

INS

INP

OS

ITIO

N

485.

00

816.00

662.00496.00

181.00

110.

0035

5.00

401.

00

AW

1531

WAT

ER IN

/OU

T 1½

” BSP

M S

TUBS

CO

ND

ENSA

TE 3

/4” B

SPM

STU

B

Page 29: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 27

WINTERISING PROCEDURE

ALL MODELS

Objective

To provide frost protectionTo eliminate corrosion problemsTo inhibit electrical components

1. Switch off electric supply to heat pump.

2. Remove external fuses and keep in safe place away from heat pump to prevent accidental operation of heatpump.

3. Ensure water circulation pump is switched off.

4. Drain water from heat pump by:

a. drain valve if fitted

b. disconnecting pipework to and from heat pump

5. Flush through water circuit in heat pump by using CLEAN TAP WATER (NOT POOL WATER) via hose intooutlet connection - run the hose for 10 minutes minimum; use spray nozzle if available.

6. Allow to drain - when drained, fit plastic bags secured by elastic bands over water connections.

7. Uncover electrical enclosure (see page 12) and liberally spray interior of unit, with moisture-repellantaerosol WD40 or similar; reseal enclosure.

8. If heat pump located outside, protect from weather by covering with VENTILATED cover. Do not use plasticsheet as condensation could occur within unit.

WARNING. Isolate machine before removing covers! The heat pumpembodies electrical and rotational equipment, it is recommended for your

own safety that a competent person carries out the following procedure

N.B. If this procedure is not adopted and frost or corrosion damage results then thewarranty will become invalid.

Page 30: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 28

START UP PROCEDURE AFTER WINTERISATION

1. Replace covers (if not fitted).

2. Remove front grille .Using a soft brush clean finned surfaces of heat pump. Replace panel.

3. Remove plastic covers on water connections and reconnect water piping or close drain valve.

4. Start up water circulating pump and leave running for at least 1/4 hour to establish flow and enable any airin piping to escape.

5. Replace fuses to heat pump circuit.

6. Switch on heat pump.

7. Check control thermostat is set to required pool temperature.

8. Check pool water daily to ensure it is at correct pH and has correct chemical balance. See Section 3Plumbing.

Page 31: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 29

WARRANTY CONDITIONS.The following exclusions apply to the Warranty given by Calorex Heat Pumps Ltd. No claims will be accepted if : -

1. The heat pump is incorrectly sized for the application.

2. The heat pump is installed in any way that is not in accordance with the current procedures as defined byCalorex Heat Pumps Ltd.

3. The heat pump has been worked upon or is adjusted by anyone other than a person authorised to do soby Calorex Heat Pumps Ltd.

4. The air flow to and from the machine is outside the specified limits.

5. The water flow through the machine is outside the specified limits.

6. The water pH level and/or chemical balance is outside the following limits:-

Acidity pH: 7.4 ± 0.4Total Alkalinity, as CaCo3 ppm 80 -120Total Hardness, as CaCo3 ppm 100-300Total Dissolved Solids: ppm MAX 3000Maximum Salt Content: wt/wt 6%Free Chlorine Range: ppm 1.0 - 3.0

Superchlorination: ppm MAX 30 for MAX 24hrsBromine: ppm 2-3Baquacil: ppm 25 - 50Ozone: ppm 0.8 - 1.0*Maximum Copper Content: ppm MAX 2*Aquamatic Ionic Purifier: ppm MAX 2*Tarn Pure Purifier: ppm MAX 2*Sherwood Purifier: ppm MAX 2

7. The heat pump has suffered frost damage.

8. The electrical supply is insufficient or in anyway incorrect.

Page 32: Owner Installation Manual for AW631, 831, 1231, 1531 AIR ... · b. The Calorex Pool Heat Pump must be connected after the filter in the return pipe to the pool. If an existing heater

Page 30

IF IN ANY DOUBT PLEASE ASK

Note:- The Reply Paid Warranty Registration Card must be returned, to ensure that the correct warranty is given.If you do not find a Registration Card with your Heat Pump please contact the Calorex Service Department givingyour name, address and serial number of your heat pump. A card will be sent to you for completion.

Email: [email protected] Website: http//www.calorex.com

01621 857171 01621 856611

Please give MODEL NUMBER and SERIAL NUMBER of your heat pump when making technical or serviceenquiries. This will assist in correct diagnosis and ensure service can be provided with the minimumdelay