7/24/2019 OXO Admin Training Presentation
1/67
Alcatel OMNIPCX OFFICE
TRAINING MATERIALS for ADMINISTRATORS
Prepared by Dave Rebong
7/24/2019 OXO Admin Training Presentation
2/67
Omni PCX Office
Overview
Architecture
HardwareConfiguration
7/24/2019 OXO Admin Training Presentation
3/67
OVERVIEW
7/24/2019 OXO Admin Training Presentation
4/67
OVERVIEW
7/24/2019 OXO Admin Training Presentation
5/67
ArchitectureTRADITIONALPABX
Private AutomaticBranch ExchangePABX
Analog
Proprietary Phone
Fax
7/24/2019 OXO Admin Training Presentation
6/67
Architecture
CONTINUESWIDE PHONE SECURITYINNOVATIONSTERMINAL PLATFORMS
MOBILITY
CONTACT UNIFIED SOLUTIONCENTER COMMUNICATION
ADVANCED INTERNET APPLICATIONRICH HOTEL
TELEPHONYACCESS OPENNESSFEATURES VOIP SERVICE Via XML
Using Linux and the Wide ALCATEL Platform
7/24/2019 OXO Admin Training Presentation
7/67
Architecture
TOPHOLOGY Environment
7/24/2019 OXO Admin Training Presentation
8/67
Cabinets
BoardsHardware & Design
Alcatel-Lucent Omni-PCX Office Compact Edition
AND RACK S/M/L MODULES:
Alcatel-Lucent Omni-PCX Office Compact Edition -
- Alcatel-Lucent Omni-PCX Office Compact Edition is a wall-mountedversion - It provides 2 slots (1xCPU slot+1xMIX slot)
-TThe Alcatel-Lucent Omni-PCX Office Compact Edition rack is not expandableand cannot be used as satellite
12 ports1 CPU slot + 1 MIX slot
Power consumption: 1.5 A (240 V)
Dimensions: H = 345 mm; W = 370 mm; D = 65mm. Weight: 5.1 kg.
7/24/2019 OXO Admin Training Presentation
9/67
Cabinets
BoardsHardware & Design
The following mixed boards areavailable:
MIX 448
MIX 484
AMIX 444-1
AMIX 484-1
AMIX 448-1
7/24/2019 OXO Admin Training Presentation
10/67
Cabinets
BoardsHardware & Design
RACK 1 (SMALL) or Small
- The RACK S module (formerly known as RACK 1) mainly consists of a plastic frame -
The plastic frame receives all the parts for attaching the power supply board, the
fans, the battery and the mains power connector, and everything. -There is no
backplane board: the metric connectors are on the power supply module. -19" rack
modules which can be mounted in a rack or placed on a shelf - it has 3 slots 1 for CPU
& 2 for card interfaces28 ports
1 CPU slot + 2 general-purpose slots (no SLI16
board) Power consumption: 1 A (230 V) / 2 A (110 V)
- 80 W. Dimensions: H = 66 mm (2.6 inches);
W = 442 mm (17,4 inches); D = 400 mm (15.76
inches). Weight: 6 kg.
7/24/2019 OXO Admin Training Presentation
11/67
Cabinets
BoardsHardware & Design
Hardware Assembly Details:
7/24/2019 OXO Admin Training Presentation
12/67
Cabinets
BoardsHardware & Design
RACK M (MEDIUM) AND RACK L (LARGE)
- The frame consists of a "U"-shaped sheath closed on the top by a riveted plate -The boards are guided by 2 rails for RACK M (formerly known as RACK 2), or 3 rails
for RACK L (formerly known as RACK 3), riveted vertically to the frame.
-The enclosure consists of a metal top part, two metal side parts and a plastic front face
Access to the fans, the power supply module and the batteries is gained by
disconnecting the power cable and unscrewing the backplane.-IIt has 6 Slots 1 for CPU & 5 for card interfaces
56 ports
1 CPU slot + 5 general-purpose slots
Power consumption: 1.2 A (230 V) / 2.3 A (110 V)- 120W.
Dimensions: H = 110 mm (4.3 inches);
W = 442 mm (17.4 inches); D = 400 mm (15.76inches). Weight: 11 kg.
7/24/2019 OXO Admin Training Presentation
13/67
Cabinets
BoardsHardware & Design
- 96 ports
- 1 CPU slot + 4 specific general-purpose
slots (no UAI16 and MIX boards)- Power consumption: 1.2 A (230 V) / 2.3 A (110 V) -150W. - Dimensions: H = 154 mm (6.1 inches)
RACK L (LARGE) W = 442 mm (17.4 inches); D = 400 mm (15.76inches). -Weight: 13 kg.
- It has 9 slots, 1 for CPU & 8 for card interfaces
The Maximum capacity:
-The system can be extended by adding oneor two modules to the main module
-All combinations are possible, with a maximum of3 modules
RACK XL (LARGE) -The maximum capacity is 236 stations.
-It has MAX of 27 slots, 1 for CPU, 2 for MEX, & 24for card interfaces
7/24/2019 OXO Admin Training Presentation
14/67
Cabinets
BoardsHardware & Design
Hardware Assembly Details:
7/24/2019 OXO Admin Training Presentation
15/67
Cabinets
BoardsCard, Modules & Interfaces
CPU Overview & Migration History
The CPU-1 board is based on the new tracking of the ASPEN CPU board and has thefollowing characteristics: 133 MHz processor, 32 MB NAND Flash, 64 MB SDRAM, DSP5410.
The CPU-2board has the same main characteristics as the CPU-1 board, except that the32 MB NAND Flash memory is replaced by a 64 MB NAND Flash memory.
The CPU-3 board has the following characteristics: 133 MHz processor, 128 MBNAND Flash, 64 MB SDRAM.
The CPU-3m board is fitted with a 133 MHz processor, a 128 MB NAND Flash memoryand 64 MB of SDRAM.
The CPU-4 board is fitted with a 133 MHz processor, a 128 MB NAND Flash memoryand 128 MB of SDRAM.
The Latest CPU is POWERCPU
7/24/2019 OXO Admin Training Presentation
16/67
Cabinets
Boards
Daughter Boards
The CPU-1/CPU-2/CPU-3/CPU-3m/CPU-4 boards can be equipped with the following
daughter boards:
HSL (High Speed Link): module interconnections. This daughter board is notcompatible with the Mini-Mix daughter board.
XMEM, XMEM-1, XMEM128-1 (eXpansion MEMory): memory extension. This
daughter board is not compatible with the VoIP daughter board.This daughter board includes a 2.5" hard drive
connector: Use a flat cable to connect a PATA harddiskUse a P2SATA-AXV daughter board to connect a SATA hard disk
AFU, AFU-1 (Auxiliary Function Unit): supporting auxiliary functions such as general bell,
door-phone, audio In, audio Out, etc. The AFU-1 board is required for the connection ofthe ISDN-EFM box (T0/S0 forwarding)
VoIP, VoIP-1 (Voice over IP): Gateway H.323 with integrated Gatekeeper function or
SIP Gateway. Supports management of CODECs and DSPs for IP telephony and IP
Trunk (IP trunk lines) applications
7/24/2019 OXO Admin Training Presentation
17/67
Cabinets
BoardsCard, Modules & Interfaces CPU-4
CPU Module
VOIP or XMEM card
CPU Module
SATA HD ConnectorProcessor
High Speed Link AFU -x
Mix Connector
7/24/2019 OXO Admin Training Presentation
18/67
Cabinets
BoardsCard, Modules & Interfaces CPU-4
Available functions:
-LAN: 10/100 base T Ethernet port (MDI-II/straight)
- AUDIO-OUT: loudspeaker, alarm and general bell interfaces; 12V output -
AUDIO-IN: please-wait message and background music interfaces -DOORPHONE: door phone interfaces- CONFIG: RS232 for MMC, NMC and PPP connections
- MODULE1: HSL link to add-on module 1 (if HSL daughter board present) - MODULE2: HSL link to add-on
module 2 (if HSL daughter board present) - ISDN T0 1: T0 access 1 if Mini-Mix daughter board present
(CPU-3m or CPU-4 only) - ISDN T0 2: T0 access 2 if Mini-Mix daughter board present (CPU-3m or CPU-4
only) - SLI1/2: access to analog terminals 1 and 2 (if Mini-Mix daughter board present on CPU-3m or CPU-
4)
7/24/2019 OXO Admin Training Presentation
19/67
Cabinets
BoardsCard, Modules & Interfaces CPU-4
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
20/67
Cabinets
BoardsCard, Modules & Interfaces POWER CPU
The Power CPU board, based on processor Power Quicc II Pro MPC8377
from Free scale, has the following characteristics:
-667 MHz processor, 256 MB DDR2 SDRAM, SD/MMC Memory card(2GB), -VoIP DSP C6421/4 (16 VoIP channels).
The Power CPU board is built around 2 main blocks interconnected viaPCI:
-CPU part with MPC8377 processor and following interfaces:
DDR 2 memory
BOOT (NOR Flash) Serial ATA for Hard Disk
SD card controller PCI
LAN interfacesI2C
7/24/2019 OXO Admin Training Presentation
21/67
Cabinets
BoardsCard, Modules & Interfaces POWER CPU
-Telecom part with INOX ASIC and with connections to:
Telecom DSP
Modem DSPVoIP DSP
Legacy Telecom architecture (PCM buses, ASL, HSL)
Daughter Boards
The POWER CPU boards can be equipped with the following daughter boards:
HSL (High Speed Link): module interconnections. This daughter board isnot compatible with the Mini-Mix daughter board.
ARMADA 16 -Gateway H.323 with integrated Gatekeeper function or SIPGateway. Supports management of CODECs and DSPs for IP telephony and IP
Trunk (IP trunk lines) applications
7/24/2019 OXO Admin Training Presentation
22/67
Cabinets
BoardsCard, Modules & Interfaces POWER CPU
AFU-1 (Auxiliary Function Unit): supporting auxiliary functions such as general bell,
door- phone, audio In, audio Out, etc. The AFU-1 board is required for the connection of
the ISDN-EFM box (T0/S0 forwarding)
MINI-MIX - Supports a combination of 2 SLI ports or 1 SO & 1 TO, or 1 SLI & 1 TO
SATEX RoHS board-connects the HD SATA to POWER CPU Module
7/24/2019 OXO Admin Training Presentation
23/67
Cabinets
BoardsCard, Modules & Interfaces POWER CPU
Power CPU Front Panel LEDs
LED Indicators & meanings
7/24/2019 OXO Admin Training Presentation
24/67
Cabinets
BoardsCard, Modules & Interfaces POWER CPU
Output Port
Available functions:
- LAN: 10/100/1000 base T Ethernet port (MDI-II/straight).
- SLI1/SLI2: Analog Z accesses from Mini-MIX board, General ringer; 12Voutput -AUX: General ringer; 12V output
-- MODULE1: HSL1 link of HSL board for connection to module expansion1 - ISDN T01: ISDN T01 port of Mini-MIX board
- MODULE2: HSL2 link of HSL board for connection to module expansion2 - ISDN T02: ISDN T02 port of Mini-MIX board
- AUDIO: Interfaces Please wait message, Background music, Loudspeaker,Alarm - DOORPHONE: Interfaces doorphone
7/24/2019 OXO Admin Training Presentation
25/67
Cabinets
BoardsCard, Modules & Interfaces POWER CPUPOWER CPU Front Panel
Output Port
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
26/67
Cabinets
BoardsCard, Modules & Interfaces POWER MEX
-The Power MEX board is a controller board for extension or module expansion.
-The Power MEX board (POWER Module EXPANSION) performs the controllerfunctions in the expansion platforms.
-The Power MEX board is equipped with an HSL1 (High Speed Link) boardfor interconnecting with the basic platform.
- The Power MEX board is connected to the MODULE 1 or MODULE 2 connector
on the Power CPU boardMeaning of the LED Indications
MEX Front Panel
RJ 45 PIN SOCKET ASSIGNMENT
Figure 2.15: HSL1 Daughter Board on Power MEX Board
7/24/2019 OXO Admin Training Presentation
27/67
Cabinets
BoardsCard, Modules & Trunk cards BRA T0 ISDN card
The BRA board The BRA(Basic Rate Access) board provides the basic access points (2 x
64-Kbps B-channels + 1 x 16-Kbps D-channel per access) for connecting the system to theISDN digital public network (point-to-point or multipoint T0 link)starting with version
R2.0,to a private network (point-to-point DLT0 link); 3 versions are offered:
Types:
- BRA2: 2 T0 accesses OUTPUT PORTS (FACEPLATE)
- BRA4: 4 T0 accesses- BRA8: 8 T0 accesses
Connection Diagram
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
28/67
Cabinets
BoardsCard, Modules & Trunk cards PRI /E1 ISDN card
The PRA board (Primary Rate Access) board provides 1 primary access for connecting the
Alcatel-Lucent Omni-PCX Office Communication Server system to the ISDN digital publicnetwork or to private networks.
Types:
PRA -T2, DASS2, DLT2: 30 x 64-Kpbs B-channels + 1 x 64-Kbps D-channel; 2048
KbpsPCM R2: 30 x 64 Kbps B-channels + 1 x 4 Kbps signaling channel; 2048 Kbps.
OUTPUT PORTS (FACEPLATE)Connection Diagram
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
29/67
Cabinets
BoardsCard, Modules & Interfaces PRI /E1 ISDN card
T2 board example
ALARM LEDS & Meanings
7/24/2019 OXO Admin Training Presentation
30/67
Cabinets
BoardsCard, Modules & Interfaces APA 4/8 card
APA Boards
This board is used to connect to the analog public network ( 4 or 8 ports).
Types: OUTPUT PORTS (FACEPLATE)
- APA 4- APA 8
Connection Diagram
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
31/67
Cabinets
BoardsCard, Modules & Interfaces SLI - xx-1
The SLI, SLI-1 or SLI-2 board (Single Line) allows the connection of 2-wireanalog terminals (Z). 3 board versions are available:
Types:OUTPUT PORTS (FACEPLATE)
- SLI4: 4 Z interfaces -
SLI8: 8 Z interfaces -
SLI16: 16 Z interfaces
Connection Diagram
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
32/67
Cabinets
BoardsCard, Modules & Interfaces UAI - xx-1
The UAI board allows the connection of digital stations (UA). The UAI-16 board
allows to remotely supply the terminals connected to the 16 interfaces from a EPS48external power supply connected to interface 1 using an external adaptation power
cable (splitter).
Types:OUTPUT PORTS (FACEPLATE)
- boards without external power supplycapability: UAI4: 4 UA interfaces
UAI8: 8 UA interfaces UAI16: 16 UA interfaces
- boards with external power supplycapability: UAI16-1: 16 UA interfaces
Connection Diagram
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
33/67
Cabinets
BoardsCard, Modules & Interfaces AMIX x/x/x-1
The AMIX-1 (Analog Mixed Line) board is used to connect the analog publicnetwork (PSTN) to the PBX. It has the following characteristics:
- 4 analog line accesses
- a maximum of 8 UAinterfaces - a maximum of 8 Zinterfaces- an OBC system interface supporting AT, Z and UAsignaling - protection features
OUTPUT PORTS (FACEPLATE)Types:
AMIX 4/8/4 -1 AMIX 4/4/8 -1AMIX 4/4/4 -1
RJ 45 PIN SOCKET ASSIGNMENT
Connection Diagram:
SAME as other modules
7/24/2019 OXO Admin Training Presentation
34/67
Cabinets
BoardsCard, Modules & Interfaces LANX -1
The LAN X board (Ethernet LAN Switch) serves to connect Ethernet terminals (IEEE 802.3 compatible)
3 board versions are available:
- LanX8 = 810/100 BT Ethernet ports (ports 1 to 7: MDI-X/crossover; Uplink: MDI-II/straight link) -LanX16 = 16 10/100 BT Ethernet ports (ports 1 to 15: MDI-X/crossover; Uplink: MDI-II/straight link) -
LANX16-1 = 16 10/100 BT Ethernet ports (ports 1 to 15: MDI-X/crossover; Uplink: MDI-II/straight link);
low consumption. Contrary to the LANX8 and LANX16 boards that are seen by the system as CPU
boards,-Green LED (left) = link status and activity:LED off: link disconnected
LED steady: link connected
LED flashing: link active -
Yellow LED (right) = speed:
off: low speed (10 or 100 Mb for Gigabit port, 10 Mb for the other ports) on: high speed (1 Gb for Gigabit port, 100 Mb for the other ports)
Connection Diagram
RJ 45 PIN SOCKET ASSIGNMENT
7/24/2019 OXO Admin Training Presentation
35/67
SYSTEM Programming / Configuration/ OMC
Alcatel OMNI-PCX OFFICE -Can be configure easy. By Default the SYSTEM is alreadypre-configured via the ALCATEL Lucent. The OXO System has its General
Characteristic:All CARDS / Modules are all HOT swappable (excluding CPU & MEX modules)
OXO automatically creates in the System Profile the cards/modules that are in-place at system usable slots.
Upon System Prep-up the PH version is loaded via LOLA tool or ex-factory configuration.
Used ONLY OMC tool for System configuration.
TELNET is not Support for OXO system.
Default IP address is 192.168.92.246/24
OXO System interface on configuration are via IP, V.24, & z modem
All System configuration/ CDB files are stored at OXO HD or NAND FLASH or can be
stored at your PC as CBD files for back-up purposes.
7/24/2019 OXO Admin Training Presentation
36/67
SYSTEM Programming / Configuration/ OMC
Starter for System programming:
GENERAL REQUIREMENTS
+CONNECT
OXO SystemPC OMC Software
7/24/2019 OXO Admin Training Presentation
37/67
SYSTEM Programming / Configuration/ OMC
OMC overview -A thick client software proprietary to OXO systems, which can be use to
fully manage the OXO system. Install the package application on your PC, used Windows
platforms such as XP Pro, SP1, SP2, & SP3, MS Server 2003, SP1 & SP2, or WIN7 SP1.
OMC LEVELS -There are 3 OMC access to the OXO Systems:
- Operator Access- Administrator Access- Installer Access
OMC Passwords -Each Levels are protected w/ unique passwords. These password
can be change depending on your requirement. Below are thedefault passwords:
- Operator Access = help1954 -Administrator Access= kilo1987
7/24/2019 OXO Admin Training Presentation
38/67
SYSTEM Programming / Configuration/ OMC
HOW TO CONNECT
Assuming that OMC was already installed follow the step procedures
Launch OMC, Select Connectto PCX
ModificationTypical PressOKStep 2 Select LAN, Fill the IP @ of
Step 1OXO, & PressOK
Step 3
kilo1987 Select ADMINISTRATOR
Enter correct password & PressOKStep 4
7/24/2019 OXO Admin Training Presentation
39/67
SYSTEM Programming / Configuration/ OMC
Accessing the Main Menu
Assuming that PMC is logged-in successfully, the administrator should see the ff menus:
Subscriber- Use the this menu for modifying pre-programmed profiles of All Extensions.
GROUP - For modifying Operator Groups, Hunting Groups & Pickup groups. System- Basic
modifications for System Date & Time, Numbering Plans, System software key Common SD -
for Add/delete & edit of Company Speed Dials/ Directory & Class grouping External Access -
Displays the current setting for External lines & edits of trunk groups.
7/24/2019 OXO Admin Training Presentation
40/67
SYSTEM Programming / Configuration/ OMC/ Subscriber
BASIC Subscriber Menu
7/24/2019 OXO Admin Training Presentation
41/67
SYSTEM Programming / Configuration/ OMC/ Subscriber
BASIC Subscriber Menu
Int. No. = Display/edit the Internal Extension Number of an Extension for OXOusers Pub. No. = Display/edit the Public DID number of an Extension for OXO
users. NAME = Display/edit/delete the Names Spelling of a user
SET TYPES = Display only the Model or Phone type assigned to a
User. REST. = Display/modify barring setting of a User Extension
Accessible Trunk Groups = Display/edit/delete trunk group access code to a given
user/s Call Distributions = 2ndpage under BASIC Subscriber Menu that display
information & routing status between external lines & subscribers. Distribution lists
may be display/edit/delete.
Rest/barring = A submenu of BASIC Subscriber Menu that contains number prefixes thateither to be allowed or restricted to the use of a user.
Advanced = A submenu of BASIC Subscriber Menu that re-direct the administrator tothe more deeper configuration for users extension.
Apply, OK, Cancel - for Validation or cancelation of any modification.
7/24/2019 OXO Admin Training Presentation
42/67
SYSTEM Programming / Configuration/ OMC/Subscriber/Call Dist.
Basic Call Distribution via External Lines
7/24/2019 OXO Admin Training Presentation
43/67
SYSTEM Programming / Configuration/ OMC
Basic Call Barring table of prefixes & rights
Apply
7/24/2019 OXO Admin Training Presentation
44/67
SYSTEM Programming via OMC\ADVANCED USER CONFIG
USER ADVANCED PROGRAMMINGCLICK ADVANCEDAdd a non Physical portsTo navigate on this
Areas to edit the for a User via IP, DECT,
OMC Page basic USER parameters Virtual users.
To apply all modified
Item at this page menu
PhysicalGo to deeper & editAddress
in Details the userOf a Portconfiguration
ExtensionUse to delete user
NumberMailbox immediately
Assigned to Name of a user,Phone set
A User Used by Dial By NameModel assigned
featuresto a user
7/24/2019 OXO Admin Training Presentation
45/67
SYSTEM Programming / Configuration/ OMC/Subscriber
CLICK DETAILSKEY
To navigate on this
OMC Page
Detailed
Configuration
Of a user
Apply
7/24/2019 OXO Admin Training Presentation
46/67
SYSTEM Programming / Configuration/ OMC/GROUPS
CLICK GROUPSICON
To navigate on this
OMC Page
Select, edit,
Add, Delete Select, edit, Select, edit, Add, DeleteEntries or members Add, Delete Entries or membersOf an Operator group Entries or members Select, edit, Of a Pickup GroupsThere are 8 groups: Of a User Group/s
Add, Delete There are 16 groups that1 for Default Group There are 30 groups thatEntries or members can be created, each1 for Opening Hours Can be created, from 540Of a Paging Groups group has 16 members1 for Restricted Hours Up to 570, each group hasThere are 8 groups thatEach group has 8 16 membersCan be created, each group hasmembers32 members
7/24/2019 OXO Admin Training Presentation
47/67
SYSTEM Programming / Configuration/ OMC/GROUPS
CLICK GROUPSICON
To navigate on this
OMC Page
Attendant GROUPS
Select, edit,
Add, Delete
Entries or members Of
an Operator groupThere are 8 groups: 1
for Default Group 1 for
Opening Hours 1 for
Restricted Hours Each
group has 8 members
7/24/2019 OXO Admin Training Presentation
48/67
SYSTEM Programming / Configuration/ OMC/GROUPS
CLICK AttendantGroups
To navigate on this
OMC Page
Use this area toModifyparameters
Apply
7/24/2019 OXO Admin Training Presentation
49/67
SYSTEM Programming / Configuration/ OMC/GROUPS
HUNTING GROUPS
Select, edit,
Add, Delete
Entries or membersOf a User Group/s
There are 30 groups that
Can be created, from 540
Up to 570, each group has
16 members
7/24/2019 OXO Admin Training Presentation
50/67
SYSTEM Programming / Configuration/ OMC/GROUPS
CLICK HUNTINGGroups
To navigate on this
OMC Page
Use this area toModifyparameters
Apply
/ / /
7/24/2019 OXO Admin Training Presentation
51/67
SYSTEM Programming / Configuration/ OMC/GROUPS
BROADCAST GROUPS
Select, edit,
Add, Delete
Entries or members Of a
Paging Groups There are
8 groups that
Can be created, each group has32 members
/ f / /
7/24/2019 OXO Admin Training Presentation
52/67
SYSTEM Programming / Configuration/ OMC/GROUPS
CLICK BROODCASTGroups
To navigate on this
OMC Page
Use this area toModifyparameters
Apply
i / fi i / /
7/24/2019 OXO Admin Training Presentation
53/67
SYSTEM Programming / Configuration/ OMC/GROUPS
PICKUP GROUPS
Select, edit, Add, Delete
Entries or members Of a
Pickup Groups There are
16 groups that can be
created, each group has
16 members
SYSTEM P i / C fi i / OMC/GROUPS
7/24/2019 OXO Admin Training Presentation
54/67
SYSTEM Programming / Configuration/ OMC/GROUPS
CLICK PICKUPGroups
To navigate on this
OMC Page
Use this area toModifyparameters
Apply
SYSTEM P i / C fi ti / OMC/SYSTEMS
7/24/2019 OXO Admin Training Presentation
55/67
SYSTEM Programming / Configuration/ OMC/SYSTEMS
CLICK GROUPSICON
To navigate on this
OMC Page
Numbering Plans
Select, edit,
Add, Delete
Entries or members Of
an Operator groupThere are 8 groups: 1
for Default Group 1 for
Opening Hours 1 for
Restricted Hours Each
group has 8 members
SYSTEM P i / C fi ti / OMC/SYSTEMS
7/24/2019 OXO Admin Training Presentation
56/67
SYSTEM Programming / Configuration/ OMC/SYSTEMS
CLICK DialingPlans
To navigate on this
OMC Page
Use this to
Select numberformats
Select to NavigateOn advanced
Numbering PlanApplyConfiguration
SYSTEM P i / C fi ti / OMC/SYSTEMS
7/24/2019 OXO Admin Training Presentation
57/67
SYSTEM Programming / Configuration/ OMC/SYSTEMS
CLICK
To navigate on this
OMC Page
Used by Numbering PlansSame as Internal Numbering PlansUsed byExternal callers, Intended for PBXNumbering Plan, For Private PABXInternalTELCO, Networks Features while inUsed during NetworkingUsers of theTo reach internal Restricted hours conversationPCX SystemUsers via AA or DID
SYSTEM P i / C fi ti / OMC/SWK
7/24/2019 OXO Admin Training Presentation
58/67
SYSTEM Programming / Configuration/ OMC/SWK
CLICK
To navigate on this Software KEYS
OMC Page
Actual CPU ID
Actual SoftwareKey Codes
To view the actual
Active features via
License unlock
Apply
SYSTEM Programming / Configuration/ OMC/SWK
7/24/2019 OXO Admin Training Presentation
59/67
SYSTEM Programming / Configuration/ OMC/SWK
CLICK
To navigate on thisOMC Page
On These Screen Menu , the SYSTEM will allow you to VIEW all the ActiveLicenses of the Omni-PCX Office.
Each TABs are Comprise of licenses that applies to a group or specific features
& Application.
Values indicated on TABs are not to modify. These are dependent on SWK
SYSTEM Programming / Configuration/ OMC/CSD
7/24/2019 OXO Admin Training Presentation
60/67
SYSTEM Programming / Configuration/ OMC/CSD
CLICK the SPEED DIAL ICON
To navigate on this
OMC Page
Add, Remove, Edit w/
Numbers & Names for
Each Speed dial entries
Click here to go to
Advance configurationApply
Validate & Apply any
Modification for BASIC
MENU
SYSTEM Programming / Configuration/ OMC/CSD
7/24/2019 OXO Admin Training Presentation
61/67
SYSTEM Programming / Configuration/ OMC/CSD
CLICK
To navigate on this Common Speed Dials
OMC Page
Right Click & Apply
SYSTEM Programming / Configuration/ OMC/External Access
7/24/2019 OXO Admin Training Presentation
62/67
SYSTEM Programming / Configuration/ OMC/External Access
CLICK ExternalAccesses
To navigate on this
OMC Page
Add, Remove, Edit the
Trunk Groups & DISA
Activation for eachLine access
Apply
SYSTEM BACK / RESTORE via OMC
7/24/2019 OXO Admin Training Presentation
63/67
SYSTEM BACK / RESTORE via OMC
Starter for System Backup / Restore
GENERAL REQUIREMENTS
CONNECT
DATA TRANSFER
OXO SystemPC w/ RESTOREOMC
SYSTEM Programming / Configuration/ OMC
7/24/2019 OXO Admin Training Presentation
64/67
SYSTEM Programming / Configuration/ OMC
HOW TO BACKUP/RESTORE
Assuming that OMC is already connected ONLINE at OXO
Step 1
Step 2
SYSTEM Programming / Configuration/ OMC
7/24/2019 OXO Admin Training Presentation
65/67
SYSTEM Programming / Configuration/ OMC
DATA TRANSFER from OXO to PC
Select the item to backup
Use to select detail coin target backup or restore
DATA transfer is going on
Step 3
Step 4
SYSTEM Programming / Configuration/ OMC
7/24/2019 OXO Admin Training Presentation
66/67
SYSTEM Programming / Configuration/ OMC
Client database saveas
Assuming that DATA transfer was already done
Click Saveastab at File Menu
Define device name
Or Customer IDDefine Client
Database Name
Saved Database on your PC
Disconnect Access to the system
7/24/2019 OXO Admin Training Presentation
67/67
End of Document