InstaTrans-XDOxygen Transmitter
Model
InstaTrans-XD - Oxygen Transmitter
The flexibility, simplicity and robustness of the proven universal InstaTrans Oxygen Transmitter is carried on to the next-generation Model InstaTrans-XD. The new platform continues to offer the benefits of the legacy transmitter, including:
• 2-wiretransmitterformfactor• Traceorpercentoxygenanalysis–settablerangingfrom0-10ppmto0-25%
• Insta-trace capability for fast recovery from newsensor installation (optional)
• AcceptsmostTeledyneindustrialmicro-fuelcells• Intrinsically safedesign forhazardousareaornon-hazardousinstallations
The InstaTrans-XD utilizes a design to meet therequirements of NEMA-4 (IP-66) levels of ingressprotectionwithwetted316SScellcompartmentbodyandfittings. The transmitter head contains the electronics
and user display interface including 4-button design toaccess functions.
A fully upgraded microprocessor-based platform givestheInstatrans-XDamorecompact,singlePCBdesigntosimplify maintenance and reduce shelf spares. Unlike the legacy model with fixed ranges, the new interface allows for a fully settable single range from 0-10 ppm to 0-25%. New advanced functions are also availableas standard including 4-20mA output adjustment tooptimize signal output and cold boot capability as abeneficial troubleshooting tool.
The InstaTrans-XD incorporates intrinsically safe design tomeetATEXZone0/1/2andFM/FMcClassIDiv1approvals when used with select intrinsic safety barriers. Additionally,theCSAapprovalextendstoClassIDiv2asa non-incendive devicewithout the use of barriers. FMapproval is pending at this time.
2
Teledyne offers custom sample systems and integration
services to meet adverseprocess and ambient
conditions!
Dimensional Diagram4.42 [112.3]
4.10
1.00 [25.4]
[104.1]
.20 [5.1]
SAMPLE OUTSAMPLE IN
9.13 [229.4]
3.09 [78.5]
POWER/SIGNALCONNECTOR
GROUNDSTRAP
InstaTrans-XD - Oxygen Transmitter
3
• Standard-1/8”tubefitting• 1/4”tubefitting• 6mmtubefitting• Nofitting–1/8”FNPTthread
• Standard–Viton®
• Buna-n• Kalrez®
• EPDM• EPR• Neoprene• Chemraz®
• NonInsta-trace• Insta-trace
Fittings (all 316SS)
Typical Interconnection for Non-Hazardous Installations
Typical Interconnection for Intrinsically Safe Installations
O-ring Seals
Insta-trace for Fast Initial Recovery
CONTROL ROOM FIELD
RefertoInterconnectionDiagramD86181forApprovedWiring
4
Teledyne Analytical Instruments (TAI) - Factory16830 Chestnut StreetCity of Industry, CA 91748, USATOLL FREE (888) 789-8168TEL: 626.934.1500FAX: 626.934.1651www.teledyne-ai.com
TAI - Houston & Gulf Coast Region USAShana KiserSales EngineerTEL: 281.557.8740MOB: 281.685.3758FAX: 281.557.8741E-mail: [email protected]
TAI - Southeast USADave SolomonSales ManagerTEL: 281.471.2935MOB: 281.414.8236FAX: 281.471.3091E-mail: [email protected]
TAI - Middle East and IndiaManoj KumarP.O. Box 121744, Z -19 BuildingSAIF Zone, SharjahUNITED ARAB EMIRATES (UAE)TEL: 971.6.5579727MOB: 971.50.6345537E-mail: [email protected]
TAI - So. East AsiaSoo Keong LimNo. J-03-2, Dataran GlomacJalan SS6/18, Pusat Bandar Kelana Jaya47301 Kelana JayaSelangorMALAYSIATEL: 603.7805.7712FAX: 603.7805.7710MOB: 6012.2010.610E-mail: [email protected]
TAI - South AmericaAngel Luhia (consultant)Av. Dellepiane 4208(C1407H2W) Buenos AiresARGENTINATEL & FAX: 54.11.4601-0050MOB: 54.911.5388-3664E-mail: [email protected]: [email protected]
WarrantyInstrument is warranted for one year against defects inmaterial or workmanship
NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice.
InstaTrans-XD - Oxygen Transmitter
SPECIFICATIONS
Ranges Single-range,user-settable,0-10ppmto0-25%
Micro-Fuel Cells TraceO2,generalservice: ClassB-2C
TraceO2,%CO2present: ClassA-2C
Insta-trace,generalservice: B71875Insta-trace
Insta-trace,%CO2present: B73016Insta-trace
PercentO2,generalservice: ClassB-1/B-1C
PercentO2,%CO2present: ClassA-5/A-5C(specialconfiguration)
Approvals/Standards
(whenwiredasperD86181diagram)FM/FMcClassIDiv1GpA-DT4whenwiredasperD86181diagram–pendingFM/FMcClassIDiv2GpA-DT4–pendingEN60079-0:2012 IEC60079-0:2011EN60079-11:2012 IEC60079-11:2011
OperatingTemperature
32–122°F(0–50°C)
Accuracy ±1%offull-scaleoperatingrange(±1 ppm below 0-100 ppm range)
Response Time (T90) 15seconds(40secondsbelow0-100ppmrange)
Recommended Flow Rate 1–2SCFH(0.5–1SLPM)
Display 4.5-digitLCD
Power 9–24VDC,loop-powered
Output Loop4-20mADC
Cable 2-conductorshielded,22AWGwires,24inches(610mm)length
Weight Approximately6pounds