+ All Categories
Home > Documents > P-1 Type Fire Alarm Control Panel : RPP-ABW...RPP-ABW Type P Type 1st Class Fire Alarm Control Panel...

P-1 Type Fire Alarm Control Panel : RPP-ABW...RPP-ABW Type P Type 1st Class Fire Alarm Control Panel...

Date post: 04-Mar-2021
Category:
Upload: others
View: 8 times
Download: 0 times
Share this document with a friend
2
HOCHIKI CORPORATION SINGAPORE BRANCH OFFICE 629 Aljunied Road #03-16 Cititech Industrial Building Singapore 389838 Tel : 65-6841-9728 Fax : 65-6841-9781 Email : [email protected] HEAD OFFICE 10-43 Kamiosaki 2-Chome. Shinagawa-Ku, Tokyo 141-8660, Japan Tel : 81-(3)-3444-4116 Fax : 81-(3)-3444-4167 URL : www.hochiki.co.jp P-1 Type Fire Alarm Control Panel : RPP-ABW Features 1. Multi purpose zone configuration - Versatile zone configuration to suit various alarm need. (Zone 1 is preset and fixed for fire alarm only) 2. Light weight and compact in size - 450mm(W) X 650mm(H) X 100mm(D), Approximately 13Kg 3. Easy installation - By means of ‘Wire Insertion’ terminals - Wide internal cabinet space of easy wiring - 180 degree wide panel door opening 4. Improved local bell control with programmable ‘silence’ timer - If the local bell is put on ‘silence’ mode after an initial alarm signal, any subsequent zone activation immediately re-triggers the local alarm. And should the system be left at ‘silence’ mode without subsequent zone activation, the local alarm will automatically trigger again after a custom preset time period from the first alarm activation. - The custom preset timer can be programmed to reactivate the local alarm after 2,4,6 or 8 minutes from the first alarm activation. 5. New functions - Improved lightning surge protection - Easy configuration of local bell and interlook release control, which can be monitored from the zone panel. - Functional test equipped with 2 reset modes for heat and smoke detectors. - ‘Hands-free’ intercom communication at control panel - Voltage display for ‘Stand by Battery’ test - Sound alert during ‘Time Delay’ operation - Optional pre-alarm alert for ‘Time Delay’ operation - Zone open circuit monitored
Transcript
Page 1: P-1 Type Fire Alarm Control Panel : RPP-ABW...RPP-ABW Type P Type 1st Class Fire Alarm Control Panel (with Time Delay Function) Model Name RPP-ABW (10,15,20) (JE) Circuit Type RPP-A24A

HOCHIKI CORPORATIONSINGAPORE BRANCH OFFICE629 Aljunied Road #03-16 Cititech Industrial BuildingSingapore 389838Tel : 65-6841-9728 Fax : 65-6841-9781Email : [email protected]

HEAD OFFICE10-43 Kamiosaki 2-Chome. Shinagawa-Ku,Tokyo 141-8660, JapanTel : 81-(3)-3444-4116 Fax : 81-(3)-3444-4167URL : www.hochiki.co.jp

P-1 Type Fire Alarm Control Panel : RPP-ABW

Features1. Multi purpose zone configuration

- Versatile zone configuration to suit various alarm need. (Zone 1 is preset and fixed for fire alarm

only)

2. Light weight and compact in size

- 450mm(W) X 650mm(H) X 100mm(D), Approximately 13Kg

3. Easy installation

- By means of ‘Wire Insertion’ terminals

- Wide internal cabinet space of easy wiring

- 180 degree wide panel door opening

4. Improved local bell control with programmable ‘silence’ timer

- If the local bell is put on ‘silence’ mode after an initial alarm signal, any subsequent zone

activation immediately re-triggers the local alarm. And should the system be left at ‘silence’

mode without subsequent zone activation, the local alarm will automatically trigger again after

a custom preset time period from the first alarm activation.

- The custom preset timer can be programmed to reactivate the local alarm after 2,4,6 or 8

minutes from the first alarm activation.

5. New functions

- Improved lightning surge protection

- Easy configuration of local bell and interlook release control, which can be monitored from the

zone panel.

- Functional test equipped with 2 reset modes for heat and smoke detectors.

- ‘Hands-free’ intercom communication at control panel

- Voltage display for ‘Stand by Battery’ test

- Sound alert during ‘Time Delay’ operation

- Optional pre-alarm alert for ‘Time Delay’ operation

- Zone open circuit monitored

Page 2: P-1 Type Fire Alarm Control Panel : RPP-ABW...RPP-ABW Type P Type 1st Class Fire Alarm Control Panel (with Time Delay Function) Model Name RPP-ABW (10,15,20) (JE) Circuit Type RPP-A24A

Hochiki Conventional System

Specifications

RPP-ABWType P Type 1st Class Fire Alarm Control Panel (with Time Delay Function)Model Name RPP-ABW� (10,15,20) (JE)Circuit Type RPP-A24AMains AC220V 50/60HzTransformer Capacity 75VAStand-by Battery DC 24V, 0.6 AHBattery Charger Ni-Cd Battery Trickle ChargerMain Sounder Speaker (Voice Alarm equipped)Operating Temperature Range 0°C – 40°CMaterial Body, Front Door : Steel, 1.2mm, Baked Paint

Display, Operation Panel : Self Extinguishing Plastic, 2mmColor Body, Front Door : Equivalent to Munsell 2.5Y9/1

Display, Operation Panel :Equivalent to Munsell 5Y6/0.5Number of Zones 10,15, or 20 ZonesWeight Approx. 13KgDimension 450mm(W) X 650mm(H) X 100mm(D)Made JAPAN

Name plate

Alarm lamp

Zone indication

Operation section

Door lock screw

Operation switch cover

450

344.

591

30075

100

20 18.8

44

(450)

39030

177.5

φ30 (for AC)

4-mounting hole φ8

322.

527

2.5

590

(650

)

125 × 50 (for DC)

30

650

168.5

Wiring Holes & Mounting Holes


Recommended