P2020 Ardentec Probe Site Qualification TM Freescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006. 12 April 2011
Transcript
Page 1: P2020 Ardentec Probe Site Qualification - NXP

P2020 Ardentec Probe Site Qualification

TM

Freescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

12 April 2011

Page 2: P2020 Ardentec Probe Site Qualification - NXP

M82Y Qualification at Ardentec Probe

Goal• Objective is to qualify Ardentec Singapore as joint probe site for probing

all flavors of M82Y (0M82Y, 1M82Y).

• Local probe site will eliminate need to ship wafers to Austin and reduce overall product cycle time.

Considerations• Test platform and probe card is identical to that used in OHT.

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

• Test platform and probe card is identical to that used in OHT.

• Test program and test limits used in Ardentec-Singapore is identical to that used in OHT.

Page 3: P2020 Ardentec Probe Site Qualification - NXP

M82Y Qualification PlanPre-correlation

Pre-Correlation items• Install and verified Prober setup files

• Install Probe Program and checked for loading errors.

• Validate Probe Card with local PCR and complete inspections on probe card locally.

Considerations• Test platform and probe card is identical to that used in OHT.

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

• Test platform and probe card is identical to that used in OHT.

• Test program and test limits used in Ardentec-Singapore is identical to that used in OHT.

Page 4: P2020 Ardentec Probe Site Qualification - NXP

M82Y Qualification Plan

Correlation items• Perform Kappa analysis (Yield and Bin correlation) of 1 wafer.

Passing Criteria: Yield to Yield difference <3%; Bin to Bin swap < 6%.

• Confirm Probe marks on one wafer.

Passing Criteria: Verify marks are acceptable per global specification.

• Execute ILD experiment with 3 different overdrive settings, 2,4, and and 8 touchdowns on one wafer and de-process top layer for visual inspection of

underlying layers.

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

Passing Criteria: No Electrical bin changes, and no under-pad damage.

Page 5: P2020 Ardentec Probe Site Qualification - NXP

P2020 ARDT Qualification Results Summary:

Test Status Results Date Completed

ILD: FSL Baseline Complete Pass 25-Mar-2011

Kappa Correlation Complete Pass 30-Mar-2011

ILD: ARDT Qual Complete Pass 7-Apr-2011

ARDT Audit Complete Pass 11-Apr-2011

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

Page 6: P2020 Ardentec Probe Site Qualification - NXP

Probe ILD Plan:Wafer: Global Foundaries:WB01M82Y; QA0291; wafer 25

Probe Card:

MJC x1 Ultra LowK Card Design

BCF 0.5, tip dia. 0.6 mil

Platform:

Teradyne UFLEX with InTest/VSM

OPUSII

Inputs:

• Probe Overdrive:

CELL

Probe

Events

40um OD

from first

2X

4X

8X

60um OD

from first

2X

4X

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

• Probe Overdrive:• 40• 60 (nominal)• 80

• Probe Events*:• 2 (typical)• 4• 8

* Note: A x1 card using double-touch probe process will make 2 touchdowns within a single probe event.

8X

80um OD

from first

2X

4X

8X

Page 7: P2020 Ardentec Probe Site Qualification - NXP

P2020 (M82Y) ASGP Probe ILD Summary:

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

Conclusion: The ASGP M82Y probe process passes electrical stability and mechanical requirements for the 60um & 80um process cells.

Page 8: P2020 Ardentec Probe Site Qualification - NXP

FSL to ARDT Kappa:

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

Page 9: P2020 Ardentec Probe Site Qualification - NXP

Conclusion / Recommendations

Conclusion• M82Y (0M82Y, 1M82Y) passes all correlation/qualification requirements

without any issues at Ardentec Singapore.

• Probe mark inspections pass all requirements without any issues.

• For ILD study: � no cells failed due to probe card related issues for any of the overdrive and

touch downs DOE conditions.

� No abnormalities noted on inspected pads post probe,

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

� No abnormalities noted on inspected pads post probe,

� No abnormalities noted on underlying layers of de-processed wafer.

Recommendations• Probe of 0M82Y and 1M82Y can be released in Ardentec-Singapore.

Page 10: P2020 Ardentec Probe Site Qualification - NXP

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

Data and Back-up Information

Page 11: P2020 Ardentec Probe Site Qualification - NXP

Probe Marks & ILD Inspection: 60um OD

Ardentec

4X

Events Probe Marks Under-Probe (ILD)

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

8X

Results: Probe marks are well centered on the probe pads.Inspection of the de-processed wafer revealed no under-probe damage.Note that some etching and discoloration from the de-processing chemistry is observed.

Page 12: P2020 Ardentec Probe Site Qualification - NXP

Probe Marks & ILD Inspection: 80um OD

Ardentec

4X

Events Probe Marks Under-Probe (ILD)

TMFreescale Semiconductor Confidential and Proprietary Information. Freescale™ and the Freescale logo are trademarks

of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc. 2006.

8X

Results: Probe marks are well centered on the probe pads.Inspection of the de-processed wafer revealed no under-probe damage.Note that some etching and discoloration from the de-processing chemistry is observed.


Recommended