Packaged Air Handling Unit LSFP Series LSFP120 April 2010 Model Number Configuration LSFP120-WI-4+1 : 4 + 1 Row: Horizontal Model: Horizontal air discharge LSFP120-WII-4+1 : 4 + 1 Row: Horizontal Model: Vertical air discharge LSFP120-AWI-4+1: 4 + 1 Row: Horizontal Model: Horizontal air discharge with fan turn 180° LSFP120-AWII-4+1: 4 + 1 Row: Horizontal Model: Vertical air discharge with fan turn 180° LSFP120-WI-6+1 : 6 + 1 Row: Horizontal Model: Horizontal air discharge LSFP120-WII-6+1 : 6 + 1 Row: Horizontal Model: Vertical air discharge LSFP120-AWI-6+1: 6 + 1 Row: Horizontal Model: Horizontal air discharge with fan turn 180° LSFP120-AWII-6+1: 6 + 1 Row: Horizontal Model: Vertical air discharge with fan turn 180°
Transcript
Page 1: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

Packaged Air Handling Unit LSFP Series

LSFP120

April 2010

Model Number Configuration

LSFP120-WI-4+1 : 4 + 1 Row: Horizontal Model: Horizontal air discharge

LSFP120-WII-4+1 : 4 + 1 Row: Horizontal Model: Vertical air discharge

LSFP120-AWI-4+1: 4 + 1 Row: Horizontal Model: Horizontal air discharge with fan turn 180°

LSFP120-AWII-4+1: 4 + 1 Row: Horizontal Model: Vertical air discharge with fan turn 180°

LSFP120-WI-6+1 : 6 + 1 Row: Horizontal Model: Horizontal air discharge

LSFP120-WII-6+1 : 6 + 1 Row: Horizontal Model: Vertical air discharge

LSFP120-AWI-6+1: 6 + 1 Row: Horizontal Model: Horizontal air discharge with fan turn 180°

LSFP120-AWII-6+1: 6 + 1 Row: Horizontal Model: Vertical air discharge with fan turn 180°

Page 2: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Packaged Air Handling Unit Horizontal Model

LSFP120

RETURN AIR

Notes for Return Air:

1. Cooling: The water in/out temp.is 7°C/12°C; the air in temp. is 27°C DB / 19.5°C WB

2. Heating: The water in/out temp. is 60°C/50°C; the air in temp. is 21°C DB.

3. The motor power offered is the motor output power.

4. The above performance is for reference only. Different air and water conditions would lead to different cooling capacity.

SPECIFICATION

Coil:

LSFP010W-LSFP 120W : φ 9.52mm, copper tube, aluminium fins

LSFP135W-LSFP 300W: φ 12.7mm, copper tube, aluminium fins

Fan and motor:

LSFP 010W-LSFP 025W: direct driven, forward curved centrifugal fan

LSFP 030W-LSFP 300W: belt driven, forward curved centrifugal fan

Filter: 15mm panel filter

Cabinet: 25mm thick double skinned panel

Drip-tray: powder painting steel sheet

PERFORMANCE DATA

Model

R

o

w

Air

Flow

4 Rows Cooling 1 Row Heating External Excess

Pressure

Motor Power Unit Weight

Total Sensible Water

Flow

Water

Resista

nce

Rated

Heating

Water

Flow

Water

Resista

nce I II III I II III Horizontal Vertical

l/s kW kW l/s kPa kW l/s kPa Pa Pa Pa kW kW kW kg kg

LSFP120-4+1

4

+

1

3333 72.2 51.6 3.5 12.0 44.0 1.1 6.0 200 300 400 3 3 4 395 381

LSPF120-6+1

6 +

1

3333 95.9 63.3 4.6 30.1 44.0 1.1 6.0 200 300 400 3 4 4 385 428

Page 3: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ho

rizo

nta

l M

od

el

LS

FP

120

Page 4: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

P

ack

ag

ed A

ir H

an

dli

ng

Un

it -

Ho

rizo

nta

l M

od

el

LS

FP

120

Page 5: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ho

rizo

nta

l M

od

el

LS

FP

120

Page 6: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ho

rizo

nta

l M

od

el L

SF

P120

Page 7: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ho

rizo

nta

l M

od

el

LS

FP

120

Page 8: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Packaged Air Handling Unit Horizontal Model

LSFP120

FAN CURVE

Page 9: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Packaged Air Handling Unit Horizontal Model

LSFP120

NOISE CURVE

Page 10: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

Packaged Air Handling Unit LSFP Series

LSFP120

April 2010

Model Number Configuration

LSFP120-LI-4+1 : 4 + 1 Row: Vertical Model: Horizontal air discharge

LSFP120-LII-4+1 : 4 + 1 Row: Vertical Model: Vertical air discharge

LSFP120-ALI-4+1 : 4 + 1 Row: Vertical Model: Horizontal air discharge with fan turn 180°

LSFP120-ALII-4+1: 4 + 1 Row: Vertical Model: Vertical air discharge with fan turn 180°

LSFP120-LI-6+1 : 6 + 1 Row: Vertical Model: Horizontal air discharge

LSFP120-LII-6+1 : 6 + 1 Row: Vertical Model: Vertical air discharge

LSFP120-ALI-6+1 : 6 + 1 Row: Vertical Model: Horizontal air discharge with fan turn 180°

LSFP120-ALII-6+1: 6 + 1 Row: Vertical Model: Vertical air discharge with fan turn 180°

Page 11: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Packaged Air Handling Unit Vertical Model

LSFP120

RETURN AIR

Notes for Return Air:

1. Cooling: The water in/out temp.is 7°C/12°C; the air in temp. is 27°C DB / 19.5°C WB

2. Heating: The water in/out temp. is 60°C/50°C; the air in temp. is 21°C DB.

3. The motor power offered is the motor output power.

4. The above performance is for reference only. Different air and water conditions would lead to different cooling capacity.

SPECIFICATION

Coil:

LSFP010W-LSFP 120W : φ 9.52mm, copper tube, aluminum fins

LSFP135W-LSFP 300W: φ 12.7mm, copper tube, aluminum fins

Fan and motor:

LSFP 010W-LSFP 025W: direct driven, forward curved centrifugal fan

LSFP 030W-LSFP 300W: belt driven, forward curved centrifugal fan

Filter: 15mm panel filter

Cabinet: 25mm thick double skinned panel

Drip-tray: powder painting steel sheet

PERFORMANCE DATA

Model

R

o

w

Air

Flow

4 Rows Cooling 1 Row Heating External Excess

Pressure

Motor Power Unit Weight

Total Sensible Water

Flow

Water

Resista

nce

Rated

Heating

Water

Flow

Water

Resista

nce I II III I II III Horizontal Vertical

l/s kW kW l/s kPa kW l/s kPa Pa Pa Pa kW kW kW kg kg

LSFP120-4+1

4

+

1

3333 72.2 51.6 3.5 12.0 44.0 1.1 6.0 200 300 400 3 3 4 395 381

LSPF120-6+1

6 +

1

3333 95.9 63.3 4.6 30.1 44.0 1.1 6.0 200 300 400 3 4 4 385 428

Page 12: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ver

tica

l M

od

el L

SF

P12

0

Page 13: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ver

tica

l M

od

el L

SF

P1

20

Page 14: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ver

tica

l M

od

el L

SF

P1

20

Page 15: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ver

tica

l M

od

el L

SF

P1

20

Page 16: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Pa

cka

ged

Air

Han

dli

ng

Un

it -

Ver

tica

l M

od

el L

SF

P12

0

Page 17: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Packaged Air Handling Unit Vertical Model

LSFP120

FAN CURVE

Page 18: Packaged Air Handling Unitesvc000691.wic063u.server-web.com/php/pdfs/LSFP/LSFP120.pdf · Packaged Air Handling Unit LSFP Series LSFP120 April 2010 ... nce I II III I II III Horizontal

April 2010

Packaged Air Handling Unit Vertical Model

LSFP120

NOISE CURVE