IAQ CASE
a concept study, not a design study
indoorAirQlogCASE ???
Page 2
Indoor Air Quality CASE Presentation by Traugott Kilgus, June 2012
Indoor Air Quality
byrecordum
MotivationMotivation
To use recordum´s expertise with the (outdoor) airpointer in the field of indoor monitoring
Qualified indoor monitoring needs a number of sensors usually coming from different manufacturers
Measurement data stored in diefferent devices, usually no common data handling and transmission and presentation.
Need of continous unattended many days operation, connected to the internet, remote controlled
To use recordum´s expertise with the (outdoor) airpointer in the field of indoor monitoring
Qualified indoor monitoring needs a number of sensors usually coming from different manufacturers
Measurement data stored in diefferent devices, usually no common data handling and transmission and presentation.
Need of continous unattended many days operation, connected to the internet, remote controlled
Page 3
IAQ CASEPrototype study
Let´s put all this in a bord CASE
Indoor airpointer CASE Indoor airpointer CASE Indoor airpointer CASE
Page 4
IAQ CASEThe anytical sensors
Basic sensors
• CO2, Temp, rH• VOC (IAQ)
• airpointer Module for Electrochemical Cells
• PID?
• Thermo pDR-1500 Mass concentration
• altenatively other manufacturers
Page 5
IAQ CASEThe anytical sensors
Other sensors
• Greywolf IQ 610
VOCs, CO2, CO, %RH, °C, and an extra electro-chemical; O3 or H2S, etc
• GrayWolf's PC-3016six size range particle counters
• What else?
Page 6
IAQ CASE
In the base part insideIn the base part inside
Power supply. Data logger components from
airQlog Space for cables
Power supply. Data logger components from
airQlog Space for cables
In the top part insideIn the top part inside
PM10 (PM2,5) Monitor pdr1500 Space for other sensor Space for recordum EC Module
PM10 (PM2,5) Monitor pdr1500 Space for other sensor Space for recordum EC Module
YOUR LOGO
In the top part outsideIn the top part outside
rH, Temp., Humidity Sensor rH, Temp., Humidity Sensor
Page 7
IAQ CASE
in a Hotel near Vienna, Public guest roomsin a Hotel near Vienna, Public guest rooms
A Bar A Coffee A Restaurant This data are gathered with
the kind allowance but also in the interrest of the owner.
We keep the name of the place strictly confidential
A Bar A Coffee A Restaurant This data are gathered with
the kind allowance but also in the interrest of the owner.
We keep the name of the place strictly confidential
Here are the results of the
IAQ monitoring
First test measurements
Page 8
IAQ CASEin a Bar
The PM10 Monitor kindly cuts the Cigarette smoke peaks at 95 µg/m³
Page 9
IAQ CASEin a Coffe Room
This 2nd room is next to the Bar, non smoking, but door (sometimes?) open
Page 10
IAQ CASEin a Restaurant
This 3rd room is next to the coffee room, non smoking, ?……….
Page 11
in a Hotel near Vienna, Public guest roomsall days
Humidity (blue) good, Temperature (red) o.k., CO2 good, means always good Oxygen Content in the room air, Particulate PM10 concentration depending mainly on Cigarette Smoke ?
Factory calibration, no site calibration, CO2 values ca.100ppm too low ! Needs calibration
RestaurantCoffee RoomBar
Page 12
Die Messgeräte befinden sich in einem Behältnis aus Karton um über eine Klappe zB Zigarettenrauch einblasen zu können. Eine einigermaßen gleichmäßige Verteilung der Rauches im Karton wird angenommen. Der Karton ist nicht ganz dicht sodass auch Umgebungsluft aufgenommen wird. Beide hier gezeigten Messgeräte haben eine eigene Ansaugpumpe. Der Messaufbau befindet sich unter einem Flugdach welche als Lager genutzt wird. Im Nachbargarten wurde an diesem trüben Tag gegrillt und Feuer gemacht.s
IAQ CASE vs. TEOM
Page 13
Basic School in Lower Austria
Page 14
Basic School in Lower Austriaone day !!??
Page 15
Protestant CHURCH in Lower Austria
Page 16
See CASE Study ALG Himberg Clinical test animals cages
Page 17
IAQ CASE
Do you like it?Comments please
Thank you for your attention
Page 18
IAQ CASE
Another way to present data measured at the same place
Page 19
IAQ CASE
This is a placeholder textThis is a placeholder text
This is a placeholder text. This text can be replaced with your own
text. All phrases can be replaced with your own text.
This is a placeholder text. This text can be replaced with your own
text. All phrases can be replaced with your own text.
This is a placeholder textThis is a placeholder text
This is a placeholder text. This text can be replaced with
your own text.
This is a placeholder text. This text can be replaced with
your own text.
Placeholderfor text
YOUR LOGO
Placeholder for your own sub headline