F L 3 6 C P G - 120 Page 1 of 4 C atalog Num bering System for M C C Bs Based on PLS001 REV .47 8/12/2013 Frame Size (Am ps) SqD /FPL/FP/ (M G) MG only B reaker P latform 100 G E C3 100 F -- EF 125 E -- EX 150 H -- M1 225 (240V) Q -- Q 2R 250 C F C1 250 K -- QK 250 J TBD M2 250 T -- C 1 (D C ) 600 D J C2 600 L -- C2 600 U -- C 2 (D C ) 800 M -- C 4R 1600 P -- C4 1600 V -- C 4 (D C ) 3200 R -- C5 P osition 2 B reakerFram e C haracter C har Meaning B B olton C D raw out (Sim plified) D D raw out(Universal) F N o Lugs (B uss C onnections) G* B us on O N end;P D C on O FF end H* Lugs on O N end; PDC O FF end J S trap C onnectors L LUG -LU G M Lugs O n E nd O nly N Plug-in B ase P Lugs O ffE nd O nly S R earC onnecting S tuds T* B us on O FF end;P D C on O N end U* Lugs on O FF end;PDC O N end A S tandard E B olton K S hroud O FF End R D raw out * S ee Lug O ptions (L)fortype ofP D C . P osition 4 Term inations NO N ILIN E B R E A K E R S ILIN E B R E A K E R S C haracter M axim um V oltage (V A C unless noted) 2 240,208Y /120 4 415Y /240, 480Y /277,480 or440 5 500 6 600Y /347 or600 or690 or600 V D C 7 500V D C 1 1000 V D C P osition 7 V oltage C haracte r Rating Trip U nit - 80% Fixed C ** 100% Fixed T* 80% Field Interchangeable R* 100% Field Interchangeable W 80% M ission C ritical G 80% /G round Factory installed J 80% /U nground Factory installed K 100% /G round Factory installed L 100% /U nground Factory installed R ating P osition 11 * R equired ifTrip U nitinterchange m ay expose live parts perU L489 section 6.1.5.13 be unitm ountconstruction A N D only copperlugs can be used. English French Spanish No character X X* X* UL /CSA / NO M */softIEC* E X IEC C X X UL/CSA/IEC M X NOM /IEC S haded area rem oved from options to avoid conflicting order designations (this area is notto be deleted from P LS 001 for record purposes). P osition 5 Language and C ertification Language C haracter C ertification * S panish and French to be added as partofM CCB labels program .NO M w illalso be added. IEC is notalw ays partofthe U L/C S A /NO M offer. C haracter 1 2 3 4 5 100 150 160 125 250 150 250 250 400 400 600 630 3 4 w ith O ver-sized N eutral (O SN) IEC (A) N eutral Protection Values forO SN (5) Phase R ating (A) UL (A) 4 2 N um berofPoles Position 6 Num berofPoles 1 Pos. < 1000 > 1000 8 100s ofA m ps 1000s ofA m ps 9 10s ofA m ps 100s ofA m ps 10 A m ps 10s ofA m ps Am pacity Fram e Am pacity (Am ps) 000_Snn = A utom atic Sw itch (See Trip System s) 000_Znn = Non-A utom atic Sw itch 000_Fnn = Fram e O nly S qD/FP/M G MG 1 240 480 600 600 D C 1000 D C B 10 -- -- 3 3 C 65 14 -- -- 5 D 25 18 14 7.5 7.5 G N 65 35 18 10 -- J H 100 65 25 -- -- K 2 2 2 -- -- L L 125 3 100 50 -- -- I 4 -- 200 200 100 -- -- R -- 200 200 100 -- -- C haracter D E N H L R IE C LB E quivalent *V alues vary. S ee C om pactN S P rice G uide forspecific values. IE C I-Line (S w indon) S tandard interrupting* C haracter C urrentlim iting* IEC -only Table Interrupting Low interrupting* H igh interrupting* 1 Shaded area used on M G NSE/NSJ/NSF breakersonly. 2 K ratings at 240/480/600 V are asfollows: P-Frame (C4)breaker: 65/50/50 kA R-Frame (C5)breaker: 65/65/65 kA 3 L rating is150kA @ 240V in the M G NSJ, CK, CM breakers 4 Irating iwll be obsolete with FI,KIand LI breakers 5P-frameis25kA at 600V forL P osition 3 Interrupting Level UL/CSA/NO M Table V oltage C lass NOTE: This graphic representation of PLS001 is a summary of the detailed Product Line Standard 001 document prepared by the Circuit Breaker Product Line Management Team in Cedar Rapids. It does not include all information found in that document. For details, and for revision history, please refer to that document.
Transcript
Page 1: Page 1 of 4 NOTE: This graphic representation of PLS001 is a summary of the detailed Product Line Standard 001 document prepared by the Circuit Breaker.

F L 3 6 CP G - 120

Page 1 of 4Catalog Numbering System for MCCBs Based on PLS001 REV. 47 8/12/2013

Frame Size

(Amps)

SqD/FPL/FP/ (MG)

MG only

Breaker Platform

100 G E C3

100 F - - EF

125 E - - EX

150 H - - M1

225 (240V)

Q -- Q2R

250 C F C1

250 K - - QK

250 J TBD M2

250 T - - C1 (DC)

600 D J C2

600 L - - C2

600 U - - C2 (DC)

800 M -- C4R

1600 P -- C4

1600 V - - C4 (DC)

3200 R -- C5

Position 2

Breaker FrameCharacter

Char Meaning

B Bolt onC Drawout (Simplified)D Drawout (Universal)F No Lugs (Buss Connections)G* Bus on ON end; PDC on OFF endH* Lugs on ON end; PDC OFF endJ Strap ConnectorsL LUG-LUGM Lugs On End OnlyN Plug-in BaseP Lugs Off End OnlyS Rear Connecting StudsT* Bus on OFF end; PDC on ON endU* Lugs on OFF end; PDC ON end

A StandardE Bolt onK Shroud OFF EndR Drawout

* See Lug Options (L) for type of PDC.

Position 4

TerminationsNON I LINE BREAKERS

I LINE BREAKERS

Character Maximum Voltage (V AC unless noted)2 240, 208Y/1204 415Y/240, 480Y/277, 480 or 4405 5006 600Y/347 or 600 or 690 or 600 VDC7 500VDC1 1000 VDC

Position 7

Voltage

Character

Rating Trip Unit

- 80% FixedC** 100% FixedT* 80% Field Interchangeable

R* 100% Field Interchangeable

W 80% Mission CriticalG 80%/Ground Factory installedJ 80%/Unground Factory installedK 100%/Ground Factory installedL 100%/Unground Factory installed

RatingPosition 11

* Required if Trip Unit interchange may expose live parts per UL489 section 6.1.5.13**For 100% rated H/J Frame, breakers may only be unit mount construction AND only copper lugs can be used.

English French SpanishNo

characterX X* X* UL / CSA /

NOM*/soft IEC*E X IEC

C X X UL/CSA/IEC

M X NOM / IEC

Shaded area removed from options to avoid conflicting order designations (this area is not to be deleted from PLS001 for record purposes).

Position 5

Language and CertificationLanguageCharacter Certification

* Spanish and French to be added as part of MCCB labels program. NOM will also be added. IEC is not always part of the UL/CSA/NOM offer.

Character

12345

100 150 160125 250150 250250 400400 600 630

3

4 with Over-sized Neutral (OSN)

IEC (A)Neutral Protection Values for OSN (5)

Phase Rating (A)

UL (A)

4

2

Number of Poles

Position 6

Number of Poles

1

Pos. < 1000 > 1000

8 100s of Amps 1000s of Amps

9 10s of Amps 100s of Amps

10 Amps 10s of Amps

Ampacity

Frame Ampacity (Amps)

000_Snn = Automatic Sw itch (See Trip Systems) 000_Znn = Non-Automatic Sw itch 000_Fnn = Frame Only

SqD/FP/MG MG 1 240 480 600 600 DC 1000 DCB 10 - - - - 3 3C 65 14 - - - - 5D 25 18 14 7.5 7.5G N 65 35 18 10 - -J H 100 65 25 - - - -

K 2 2 2 - - - -

L L 1253 100 50 - - - -

I4 -- 200 200 100 - - - -R -- 200 200 100 - - - -

CharacterDENHLR IEC LB Equivalent

*Values vary. See Compact NS Price Guide for specific values.

IEC I-Line (Swindon)

Standard interrupting*

Character

Current limiting*

IEC-only TableInterrupting

Low interrupting*

High interrupting*

1 Shaded area used on MG NSE/NSJ/NSF breakers only.2 K ratings at 240/480/600 V are as follows: P-Frame (C4) breaker: 65/50/50 kA R-Frame (C5) breaker: 65/65/65 kA3 L rating is 150kA @240V in the MG NSJ, CK, CM breakers4 Irating iwll be obsolete with FI,KIand LI breakers5 P-frame is 25kA at 600V for L

Position 3

Interrupting LevelUL/CSA/NOM Table

Voltage Class

NOTE: This graphic representation of PLS001 is a summary of the detailed Product Line Standard 001 document prepared by the Circuit Breaker Product Line Management Team in Cedar Rapids. It does not include all information found in that document. For details, and for revision history, please refer to that document.

Page 2: Page 1 of 4 NOTE: This graphic representation of PLS001 is a summary of the detailed Product Line Standard 001 document prepared by the Circuit Breaker.

U63

Page 2 of 4

Family Family

1 100 16 -- 15 400 150 D2 25 -- 25 250 D3 30 -- 40 400 D3 32 -- 40 250 400 NS4 40 -- 60 400 600 NS5 50 -- 63 400 630 NS6 60 -- 25 600 250 U6 63 -- 30 300 U8 80 -- 40 400 D,U10 100 NS 50 500 U3 150 30 -- 60 600 D,P10 100 150 -- 63 630 630 D,P12 125 -- 80 800 800 P15 150 H 80 1200 800 P15 100 150 NS 10 1000 P,R16 100 160 NS 12 1200 P,R25 125 250 NS 12 1250 1250 P25 150 250 NS 16 1600 1600 P12 160 125 -- 06 1600 600 V16 160 NS 08 1600 800 V10 250 100 T 10 1600 1000 V15 250 150 NS,T 12 2000 1200 R16 160 NS 16 1600 R17 175 J 20 2000 R20 250 200 T 20 2500 2000 R22 225 NS 25 2500 R

25 250 J 30 3000 3000 R32 3200 3200 R

Continuous Current Rating

Positions 13 and 14, with the Automatic Switch (S) option, Non-Automatic Switch (Z) option, Frame-only (F) and 4-Pole with protected neutral (N). Two digits define the continuous current rating of the device.

Frame Size

Amps

Phase Amp

Rating

Oversized Neutral Rating

Frame Size

Amps

* For Switch ratings with oversized neutral, use Phase amperage for the character. Example: NFHF56000S15 is a 150 A Switch with 250 A oversized neutral.Note: Shaded cells are IEC only products

Char.*

Char.*

Phase Amp

Rating

Oversized Neutral Rating

Char. Trip Range (Amperes)

Char. Trip Range (Amperes)

Char. Trip Range (Amperes)

1 9 - 33 31 1125 - 2250 61 75 - 1752 21 - 77 32 1250 - 2500 62 150 - 3503 45 - 165 33 1500 - 3000 63 300 - 7004 90 - 330 34 1500 - 6500 64 600 - 14005 150 - 550 35 1750 - 3500 65 Undefined6 225 - 825 36 2000 - 4000 66 Undefined7 450 - 1650 37 2000 - 6000 67 900 - 100008 600 - 2200 38 2000 - 8000 68 1200 - 100009 750 - 2750 39 Undefined 69 1500 - 10000

10 750 - 1600 40 2500 - 5000 70 1800 - 1000011 8 - 28 41 2500 - 7500 71 4 - 1712 18 - 70 42 3000 - 6000 72 1 - 913 50 - 180 43 3000 - 8000 73 5 - 4514 75 - 260 44 3500 - 7000 74 40 - 12515 100 - 350 45 4000 - 8000 75 110 - 20016 150 - 580 46 4500 - 9000 76 1500 for 24ms

17 250 - 750 47 5000 - 10000 77 1750 for 24ms

18 300 - 1100 48 6000 - 10000 78 2000 for 24ms

19 300 - 1000 49 6000 - 12000 79 2250 for 24ms

20 300 - 800DC 50 8000 - 14000 80 2500 for 24ms

21 400 - 800 51 800 - 1300 81 300 - 600

22 500 - 1000 52 1200 - 1950 82 500 - 850

23 500 - 1200DC 53 1760 - 2860 83 400 - 850

24 450 - 1100 54 24 - 64DC 84 800 - 1450

25 625 - 1250 55 3150 - 6250 85 900 - 1700

26 750 - 1500 56 6327 750 - 1500DC 57 80

28 750 - 1600 58 125

29 875 - 1750 59 15 - 3530 1000 - 2000 60 38 - 88

NOTE: For Powerpact H/J/L with Micrologic Trip Units:

M37=1.3M L-FRAME MCP

M38 = 2.2M H/J-FRAME STANDARD MCP / 2.3M L-FRAME MCP

M58=6.2E-M H/J-FRAME ENERGY MCP/6.3E-M L-FRAME ENERGY MCP

Magnetic Trip Range

Character Option Character Option1 D - type (LI) 0 no options2 S - type (LSI) 1 Option T: Residual type ground fault3 G - type (LSI) 2 Option R: Load monitoring4 M - type (LSI) 3 Option F: LED fault indicators5 U - type (LSI) 4 Options T+F (see above)

5 Options R+F (see above)6 Options T+R (see above)7 Options T+R+F (see above)8 Options F (see above) + I (ammeter)9 Options F+T+I (see above)

Trip Unit Type (1st Digit) Protective Functions (2nd Digit)Electronic Trip Unit (STR)

Positions 13 and 14 following "E" prefix. The first digit defines the trip unit type and the second digit defines the protective function.

Char. Option Char. Option3 Micrologic Type Basic 1 LI (UL)4 Micrologic Type A (Ammeter) 2 LSO (IEC)5 Micrologic Type E (Energy) 3 LSI (UL/IEC)6 Micrologic Type P (Power) 4 LSIG (UL/IEC)

7 Micrologic Type H (Harmonics) 5 LSIV (IEC)

6 LIV (UL/IEC)7 Im Magnetic Only (UL)8 Im and OL Protection (UL)

Positions 13 and 14, following "U." The first character defines the trip type and the second defines the protection type.

For Micrologic Trip Unit (Unn)Control Unit Type (1st Digit) Protection Types (2nd Digit)

A E11

V

Q

Character Option

Q Special CT Calibration (CT characterization)

CT Characterization

Position 19, w hen Position 12 = “U” and Position 13 = “6” or “7”

Catalog Numbering System for MCCBs Based on PLS001 REV. 47 8/12/2013

Page 3: Page 1 of 4 NOTE: This graphic representation of PLS001 is a summary of the detailed Product Line Standard 001 document prepared by the Circuit Breaker.

2nd Char. Option 2nd Char. Option

A 1 - Form C E 1 - Form C (Gold Flashed)

B 2 - Form C F 2 - Form C (Gold Flashed)

C 3 - Form C G 3 - Form C (Gold Flashed)

D 4 - Form C H 4 - Form C (Golf Flashed)

J 8 - Form C K 12 - Form C

Aux Switch (A) Info

For the Aux Sw itch (A) option, the second character gives configuration information:

S

Page 3 of 4

1st Char. Option

E Communications

W or V Programmable Contacts

Q Calibration

# I-Line Phasing

G POWERLINK introducer

A Auxiliary Sw itch

B Alarm / Overcurrent Trip Sw itch

S Shunt Trip

U UVR, no intentional time delay

F Adjustable Time Delay UVR

K Non-adj. Time Delay UVR

V VIGI Module

M Motor Operator

N Com Motor Operator

R Rotary Handle

T Special Terminations

H Plug-in & Draw out Options

D Disconnecting Blocks

L Lug Option

J Key interlock

C Special Ambient

P Add-on Ammeter

Y Special Option

See Sequence Rules on page 4 for order.

Installed Options

The positions follow ing ampacity, or trip unit, or rating plug designate installed options

2nd Char. Option3 Powerlink Gen 3 system

For the POWERLINK option (G), the second character options are:

POWERLINK (G)

Char. w/ Black Handle and Black Bezel Char. w/ Red Handle and Yellow BezelD10 Direct Mounted D20 Direct Mounted D11 Direct Mounted w/ 1 Form C(early make) D21 Direct Mounted w/ 1 Form C(early make)

D12 Direct Mounted w/ 1 Form C(early break) D22 Direct Mounted w/ 1 Form C(early break)

D13 Direct Mounted w/ 2 Form C(early make) D23 Direct Mounted w/ 2 Form C(early make)

D14 Direct Mounted w/ 2 Form C(early break) D24 Direct Mounted w/ 2 Form C(early break)

D15 Direct Mounted w/ 1 EB + 1 EM D25 Direct Mounted w/ 1 EB + 1 EMD16 Direct Mounted w/ 2 EB + 2 EM D26 Direct Mounted w/ 2 EB + 2 EMD17 Direct Mounted w/ 2 EB + 1 EM D27 Direct Mounted w/ 2 EB + 1 EMD18 Direct Mounted w/ 1 EB + 2 EM D28 Direct Mounted w/ 1 EB + 2 EME10 Extended E20 ExtendedE11 Extended w/ 1 Form C(early make) E21 Extended w/ 1 Form C(early make)E12 Extended w/ 1 Form C(early break) E22 Extended w/ 1 Form C(early break)E13 Extended w/ 2 Form C(early make) E23 Extended w/ 2 Form C(early make)E14 Extended w/ 2 Form C(early break) E24 Extended w/ 2 Form C(early break)E15 Extended w/ 1 EB + 1 EM E25 Extended w/ 1 EB + 1 EME16 Extended w/ 2 EB + 2 EM E26 Extended w/ 2 EB + 2 EME17 Extended w/ 2 EB + 1 EM E27 Extended w/ 2 EB + 1 EME18 Extended w/ 1 EB + 2 EM E28 Extended w/ 1 EB + 2 EMT10 Telescopic shaft T20 Telescopic shaftT11 Tele. Shaft w/ 1 Form C(early make) T21 Tele. Shaft w/ 1 Form C(early make)T12 Tele. Shaft w/ 1 Form C(early break) T22 Tele. Shaft w/ 1 Form C(early break)T13 Tele. Shaft w/ 2 Form C(early make) T23 Tele. Shaft w/ 2 Form C(early make)T14 Tele. Shaft w/ 2 Form C(early break) T24 Tele. Shaft w/ 2 Form C(early break)T15 Tele. Shaft w/ 1 EB + 1 EM T25 Tele. Shaft w/ 1 EB + 1 EMT16 Tele. Shaft w/ 2 EB + 2 EM T26 Tele. Shaft w/ 2 EB + 2 EMT17 Tele. Shaft w/ 2 EB + 1 EM T27 Tele. Shaft w/ 2 EB + 1 EMT18 Tele. Shaft w/ 1 EB + 2 EM T28 Tele. Shaft w/ 1 EB + 2 EM

2nd Char. “ON” end “OFF” endA I-LIne Shroud and Jaws (Line Side) English Terminal Nut Inserts for Bus or

Crimp Lug (Default for H/J, D and M/P. Tapped hold for R) (Load Side)

B I-Line Shroud and Jaws (Load Side) Metric Terminal Nut Insert for Bus or Crimp Lug (option for H/J) (Load Side)

C Vertical Terminals Vertical TerminalsD Vertical Terminals Horizontal TerminalsE Vertical Terminals Front Connection TerminalsF Horizontal Terminals Horizontal TerminalsG Horizontal Terminals Vertical TerminalsH Horizontal Terminals Front Connection TerminalsJ Front Connection Terminals Front Connection TerminalsK Front Connection Terminals Vertical TerminalsL Front Connection Terminals Horizontal TerminalsM Studs with Nuts/Washers Installed Lugs Off EndN Lugs On End Studs Off End, No Nuts/WashersP Studs without Nuts/Washers Installed Lugs Off EndQ Lugs On End Lug Right Pole, Stud Left Pole, no

nut/washerR Special Plug-in Jaws Lugs Off EndS Studs On End, No Nuts/Washers Studs Off End, No Nuts/WashersV Plug-in/Drawout w/ front connect lugs Plug-in/Drawout w/ front connect lugs

W * For -F-, Metric terminal nuts both ends (Default for Powerpact L)

For -F-, Metric terminal nuts both ends(Default for Powerpact L)

X * For -M-, lugs on ON endFor -P-, metric terminal nuts on ON end

For -M-, metric terminal nuts OFF endFor -P-, lugs on OFF end

Shaded fields apply to QB/QD/QG/QJ only* W, X apply metric terminal nuts to H/J Frame when termination character (4th) is F, M, P

OptionSpecial Terminations (T)

For the Special Terminations (T) option, the second character options are:

G A S, F/K/U, M/NB

2nd Char. Option

A NO

B NC

C 1 - Form C (SD)

D 1 - Form C (SDE)

E SD + SDE

F NO (Gold Flashed)

G NC (Gold Flashed)

H 1 - Form C (SD) (Gold Flashed)

J 1 - form C (SDE) (Golld Flashed

K SD + SDE (Gold Flashed)

L 1 form C long time trip

N 1 form C instantaneous tripS 1 form C short time trip

For the Alarm Sw itch (B) option, the follow ing character describes contact configuration:

Alarm Switch (B) Info

Char. OptionA ME – 200/440VacB MH - 200/440VacC MH - 440/550VacD MB - 200/440VacE MB - 440/550VacF Insulation monitorG Factory-installed GFM150HDH Factory-installed GFM250JDL Factory-installed ELM150HDM Factory-installed ELM250JD

For the Vigi (V) ground fault protection option, the second characters are:

Vigi (V) Option

V

R T

Catalog Numbering System for MCCBs Based on PLS001 REV. 47 8/12/2013

Char. Option Char. Option

A 120 Volts AC M 6 Volts DC

B 208 Volts AC N 12 Volts DC

C 240 Volts AC O 24 Volts DC

D 277 Volts AC P 48 Volts DC

E 380 Volts AC Q 72 Volts DC

F 415 Volts AC R 125 Volts DC

G 440 Volts AC S 250 Volts DC

H 480 Volts AC T 525 Volts AC

I 347 Volts AC U 30 Volts DC

J 600 Volts AC V 60 Volts DC

K 24 Volts AC W 42 Volts AC

L 48 Volts AC

For the Shunt Trip (S or E), UVR (F, K, or U) & Motor Operator (M or N) options, the second character provides voltage information.

Shunt (S), UVR (U, F, K) and Motor Operator (M or N)

To more installed options (Page 4)

Page 4: Page 1 of 4 NOTE: This graphic representation of PLS001 is a summary of the detailed Product Line Standard 001 document prepared by the Circuit Breaker.

Page 4 of 4

Provision only (vertical mount) C4R/C4 A A -- --Provision only (horizontal mount) C4R/C4/C5/C4E K R B DProvision + one lock (vertical mount) C4R/C4 G H -- --Provision + one lock (horizontal mount) C4R/C4/C5/C4E L S C FProvision + two locks keyed alike (vertical) C4R/C4 N V -- --Provision + two locks keyed alike (horizontal) C5 N V -- --Provision + two locks keyed differently (vertical) C4R/C4 P W -- --

Provision + two locks keyed differently (horizontal) C5 P W -- --

Provision only (vertical mount) includes padlock attachment - Not available on I-line

C4/C5 E E -- --

Char. Option Char. Option Char. OptionA No locks or interlocks 0 No Switches 0 No shuttersB Door interlock 1 Connected 1 ShuttersC Racking interlock 2 DisconnectedD Cylinder lock 3 Conn. + Disc..E Door & Racking interlocksF Door interlock + Cyl. lockG Racking interlock + Cyl. lock

H Door & Racking + CylinderJ No Stationary Part

For the Plug-in and Drawout (H) option, the second, third & fourth character options are:

2nd Char (Interlocks and Locks) 3rd Char (Position switches)

4th Char (Shutters)Plug-in and Drawout (H) options

Char. OptionA Standard Configuration

Disconnect Block (D)

The Disconnect Block (D) option will be followed by one character giving the appropriate number of secondary connections. Note: Disconnect block is already included on all H, J and L frame plug-in or drawout breakers, “DA” suffix is not required for H,J,L frame. DA suffix is for Compact.

2nd Char. OptionA 50 CelsiusB Special Low Temperature Grease

The Special Ambient (C) option will be followed by one character giving the calibration temperature, in Celsius.

Special Ambient (C)

Char OptionA 100AB 150A or160AC 250AD 400AE 600A or 630AF 100A CT onlyG 150A or 160A CT onlyH 250A CT onlyJ 400A CT onlyK 600A or 630A CT onlyL 100A CT w/I max

M 150A or 160A CT w/I max

N 250A CT w/I max

P 400A CT w/I max

Q 600A or 630A CT w/I max

Ammeter (P) Option

For the Ammeter (P) option, the second character options are:

Char. Option Char. OptionA * 3-wire PDC; Factory-installed P * 6-wire PDC; Factory-installedB * 4-wire PDC; Factory-installed Q * 12-wire PDC; Factory-installedC Copper Lugs R High Amp Cu Lugs with Control Wire Tapped

on ON End of ProductD High Amp Copper Lugs S High Amp Cu Lugs with Control Wire Tapped

on OFF End of ProductE High Amp Al Lugs with Control Wire

Tapped on ON End of ProductT High Amp Cu Lugs with Control Wire Tapped

on Both Ends of ProductF High Amp Al Lugs with Control Wire

Tapped on OFF End of ProductU Al lugs with Control Wire Tapped on ON End

of ProductG High Amp Al Lugs with Control Wire

Tapped on Both Ends of ProductV Al lugs with Control Wire Tapped on OFF End

of ProductH High Amp Standard (Al) Lugs W Al lugs with Control Wire Tapped on Both

Ends of ProductK Cu lugs with Control Wire Tapped on

ON End of ProductX * 5-wire PDC; factory-installed

L Cu lugs with Control Wire Tapped on OFF End of Product

Y Low Amp lug on high amp breaker

M Cu lugs with Control Wire Tapped on Both Ends of Product

Z Al lugs with Control Wire Tapped on Left and Center Poles of OFF end of product

Jº Mid range lug on high amp breaker Nº Mid range lug on high amp breaker with control tap

D1^ Stepped Copper Lugs D2^̂ FWBS Copper LugsH1^ Stepped Alum Lugs H2^̂ FWBS Alum Lugs

Y1 Low amp lug on high amp breaker with control tap

Lugs Option (L)The character following the Special Options (L) defines the lug configuration.

* Used with G, H, T, U, or A in position 4. º For M & P-Frame, the "LJ" lug is the 48010-119-52 lug without a control wire tap. This lug is currently only available in the AL800P7K lug kit. For P frame, this lug is only applied to load end. º For M & P-Frame, the "LN" lug is the 48010-119-53 lug with a control wire tap. This lug is currently only available in the AL800P7TK lug kit. For P frame, this lug is only applied to load end.** For 100% rated H/J, only copper lugs can be used. Therefore, the only lug options are K,L,M for 100% rated H/J frame breakers. ̂L-frame option, not for use on I-Line, ^^L-frame option, not for use on 4 Pole

H D

C

Y

P

L

J

More Installed Options

2nd Char. Option 2nd Char. Option

A Marine SA rating, w ith Cu lugs only and marine rating label

P Handle Padlock Attachment, ON or OFF Positions

B Padlockable Push Button Cover (Electrically-operated P-Frame Only)

Q Handle Padlock Attachment, OFF Position Only

C Cable Interlocks R Rod Interlocks

D Test Report S Ship w ithout terminal pad kit

E Longer Handle Extension G Mechanical Operations Counter

F Fungus Treat V External voltage sensing**

J Special Requirements (Japan) W Walking Beam (or equivalent)

K Ship breaker in closed position H Wiring Harness (per installed options)

H1 Wiring Harness for all installed non-communication accessories except external NCT and ZSI

H2 Wiring Harness for all installed non-communication accessories PLUS external NCT

H3 Wiring Harness for all installed non-communication accessories PLUS ZSI

H4 Wiring Harness for all installed non-communication accessories PLUS external NCT and ZSI

M Remote Reset - 110Vac (C4E only) N Remote Reset - 230Vac (C4E only

L Removed Handle Extension A1 Naval SB rating, w ith Cu lugs only and Navalrating label

* • Character “Y” follow ed by a 3-digit number (e.g. Y123) is used to define “customer special”. If the catalog number exceeds 25 characters, some features/ options w ill be combined into this Yxxx (in variable positions) so that the number of characters is 25 or less. • Packing Characters such as RP and Z shall remain part of the catalog number and not be placed into the Yxxx variable positions. ** Valid only for Pow erpact P/R

Special Options (Y):

Catalog Numbering System for MCCBs Based on PLS001 REV. 47 8/12/2013


Recommended