This document sets forth certain operational parameters and conditions f or operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assume soleand full responsability and shall indemnify seller with respect to all product faliures, and all the consequences thereof. Operation of the product outside of the parameters and conditions specifiedherein shall serve to invalidate all seller warranties, if any, with respect to the product. Use this document as reference only. For specifications please contact Panasonic's engineering department.
Panasonic Industrial CompanyAir Conditioning Department
5KS150FAB21208 / 230 V, 60 Hz, 1Ø R410A
Net Weight 40.6 lb 18.4 kg.
Relay (GE part number) 3ARR3J5A6
Start Capacitor 189 - 227 µF/ 330 V
UL: SA4615
35 µF/ 370 V
InternalRun CapacitorOverload Protector
Max. Continuous CurrentWinding Resistance
Motor Type
Locked Rotor Amperes
Permanent Split Capacitor40 A @ 240 V
2.095 Ω(Main), 2.153 Ω(Aux.)
11.93 A
23.7 fl. oz. 700 cm³
FV50S.15.06 cm³ / rev.
Rotary
Displacement
Pump Type
Oil
Oil Charge (Precharged)
E.E.R.
Current
Capacity
Motor Input14,620 BTU/h.1,535 W
6.70 A
9.52
R410A
67.0 oz. max. 1900 g. max.
56.4 oz. max. 1600 g. max.Cooling (C) / Heating (H)
Refrigerant
(C)Ref. Charge Limit (C & H)
Application
115 °F 46.1 °C
65 °F 18.3 °C
130 °F 54.4 °C
45 °F 7.2 °C
Condensing Temp.
Evaporating Temp.
Return Gas Temp.
Liquid Temp.
Ambient Temp. 95 °F 35 °C
5KS150FAB21
Rated Performance @ 230 V
Rated ARI Conditions
Compressor Data
Motor Data
Electrical Components
Approval(s)
*NOTE: If additional torque is required to start the compressor please use a start capacitor and relay. (Ex. when using a TXV.)
266 °F 130 °C
239 °F 115 °C
95 °F 35 °C
149 °F 65 °C
Return Gas Temp.
Condensing Temp.
Discharge Gas Temp.
Motor Wire Temp.
5°F to 66.2°F -15°C to 19°CEvap. Temp. Range
Maximum Operating Conditions
This document sets forth certain operational parameters and conditions f or operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assume soleand full responsability and shall indemnify seller with respect to all product faliures, and all the consequences thereof. Operation of the product outside of the parameters and conditions specifiedherein shall serve to invalidate all seller warranties, if any, with respect to the product. Use this document as reference only. For specifications please contact Panasonic's engineering department.
Panasonic Industrial CompanyAir Conditioning Department
5KS150FAB21208 / 230 V, 60 Hz, 1Ø R410A
Ambient (Air Over)
Return GasLiquid Sub Cooling
651595
Temp. Units: ° F
Performance Data @ 230 V, 60 Hz
Con
dens
ing
Tem
pera
ture
(°F
)
Cap
acity
(BTU
/h)
Mot
orIn
put(
W)
Cur
rent
(A)
Evaporating Temperature ( °F )
5 10 15 20 25 30 35 40 45 50 55
Con
dens
ing
Tem
pera
ture
(°F
)
10000
12500
15000
17500
20000
22500
5000
8090100
110
120130140
500
750
1000
1250
1500
1750
80
90
100
110
120
130
140
7500
2.0
4.0
6.0
8.0
9080
100110120130140
Evaporating Temperature ( °F )
Evaporating Temperature ( °F )
Con
dens
ing
Tem
pera
ture
(°F
)
5 10 15 20 25 30 35 40 45 50 55
5 10 15 20 25 30 35 40 45 50 55
This document sets forth certain operational parameters and conditions f or operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assume soleand full responsability and shall indemnify seller with respect to all product faliures, and all the consequences thereof. Operation of the product outside of the parameters and conditions specifiedherein shall serve to invalidate all seller warranties, if any, with respect to the product. Use this document as reference only. For specifications please contact Panasonic's engineering department.
Panasonic Industrial CompanyAir Conditioning Department
5KS150FAB21208 / 230 V, 60 Hz, 1Ø R410A
Ambient (Air Over)
Return GasLiquid Sub Cooling
651595
Temp. Units: ° F
X = C1 + C2 * (S) + C3 * D + C4 * (S²) + C5 * (S * D) + C6 * (D²) + C7 * (S³) + C8 * (D * S²) + C9 * (S * D²) + C10 * (D³)
Formula
C1 - C10: Coefficiency S: Evap. Temp. (°F) D: Cond. Temp. (°F)Sub CoolingAmbient Temp
Super Heat
Temp. Units: ° F
201595
Coefficiency
Performance Data @ 230 V, 60 Hz
-0.001666667 -0.000648148 4.62967 E-07 -1.74965 E-05-0.0002054814.28571 E-060.000627551-0.015741497
0.000373087 -0.000404974 -1.84949 E-06 0.000168098-0.0001923012.6455 E-060.000429894-0.012678571
0.914506803 0.152304422 -0.000479763 0.0099851760.029732963-0.000360459-0.0027933671.717886905
3.550414541 -0.075393282 -0.00038159 0.027447807-1.6810929130.1264835-0.222956231-191.13001170.2417630580.0227022520.81211262391.70994898
C9C10
C5C6
C8C7
C3C4
C2186.5944292-3.904916775137.568576419565.90099C1
Capacity(BTU/h)
Input(W)
Amps(A)
Mass Flow(lb/h)
Coefficiency
Evap. Temp.
Cond. Temp. 80 °F 90 °F 100 °F 110 °F 140 °F130 °F120 °F
55 °FBTU/hWatts
Amperes
AmperesWatts
BTU/h45 °F
25 °FBTU/hWatts
Amperes
AmperesWatts
BTU/h35 °F
15 °FBTU/hWatts
Amperes
AmperesWatts
BTU/h5 °F
5.13.9 5.44.6 6.05.5
6.45.6 6.04.7 5.34.2
4.3 5.44.8 6.25.9 6.8
7.06.0 6.44.8 5.44.3
4.2 5.44.8 6.76.1 7.1
6.1 7.26.74.7 5.44.11555140012551080930 1680
945 1085 1260 1400 1535 1660
16151505138512501105965
1460135012251090960 1560
935 1070 1190 1305 1390 1475
1305 13751130 12351025900
23745 22685 179951963521280 16350
1312517325 15900 146201856519515
16835 15970 123501358014845 11165
873011615 10590 96251255513305
10940 10295 793086759505 7280
64158005 7365 683086459200100707853.5
3.6805
11930
180908153.6
3.6820
14415
208607853.5
3.4760
25220
This document sets forth certain operational parameters and conditions f or operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assume soleand full responsability and shall indemnify seller with respect to all product faliures, and all the consequences thereof. Operation of the product outside of the parameters and conditions specifiedherein shall serve to invalidate all seller warranties, if any, with respect to the product. Use this document as reference only. For specifications please contact Panasonic's engineering department.
Panasonic Industrial CompanyAir Conditioning Department
5KS150FAB21208 / 230 V, 60 Hz, 1Ø R410A
(There must be clearancebetween Grommet & Nut)0.02 - 0.08 in. (0.5 - 2 mm)
0.39 in. (10mm) DIA.
CHASSIS GROMMET
COMPRESSORBASE
NUT
MOUNTING STUD
4
3
2
1
Grommet 7070823
Nut 7080300
7070621UNut Gasket
Terminal Cover Gasket 7070632U
7070231UTerminal Cover
PART NUMBERACCESSORIES
2
1
4
3
5
C
S
R
LINE
COMPRESSOR
RUNCAPACITOR
OLP
WIRING DIAGRAM
10°
1.42
(R 1.07)
2.36
COMPRESSOR ACCESSORIES
COMPRESSOR MOUNTING
C
S
R
LINE
COMPRESSOR
RUNCAPACITOR
STARTRELAY
STARTCAPACITOR
0.551.65
95°
75°
1.32
0.79
12.17
2.33
11.854.76
3.51 dia.
5.20
4 - 0.98 dia.
7.50
7.50
R1.03
45°
90°
90°
1.02
OK
0411
24M
22
BASE ANGLE
OIL MARK
MODEL NO.SCREW
MFG. DATE
LABEL
RETAINERACCUMULATOR
ACCUMULATOR
SUCTION0.632/0.626 I.D.
CAP TERMINALPROTECTION
SEAL CAPBOLT-TERMINAL COVER
DISCHARGE 0.382/0.378 I.D.
BASE
OLP