PanelMax™ Shielded Wiring Duct and Noise Shield route, separate, and shield sensitive wiring from noise emission. This allows pathways to be placed in closer proximity, saving valuable space within industrial control panels. The shielding provides up to 20dB reduction in noise (EMI/RFI), or 90% noise voltage reduction (NVR), which is equivalent to 6 inches of air spacing between sensitive and noise-emitting wiring.* ** Several wire routing and segregation configurations are possible with the innovative Shielded Wiring Duct and Noise Shield, delivering greater design flexibility to satisfy a wide range of applications. These products are part of the broad range of reliable product systems offered by the Panduit Industrial Automation Solution. These product systems aid in reducing design and assembly time, create valuable panel space savings, and provide easier installation and maintenance.
K e y F e a t u r e s B e n e f i t s
Durable metallic foil covers and shields outer duct surfaces providing EMI/RFI noise reduction between sensitive and noisy wiring for up to 20dB reduction in noise, or 90% NVR (equivalent to 6 inches of air spacing)
Fully contains and protects wiring; easy to cut and install; ensures reliable performance and improved aesthetics; used with standard Panduit wiring duct cover; installs with standard fasteners, including Panduit NR1 rivets
Upper and lower score lines Facilitate duct finger and sidewall section removal to ease installation and wire routing
Provide wire management capability and noise reduction in the full height of the duct; slot size compatible with various wire types and sizes, including UTP Ethernet cabling
PanelMax™ Shielded Wiring Duct
PanelMax ™ Noise Shield K e y F e a t u r e s B e n e f i t s
Metal noise barrier* **^‡ Reduces EMI/RFI noise between sensitive and noisy wiring for up to 20dB reduction in noise, or 90% NVR (equivalent to 6 inches of air spacing); innovative design installs easily within Panduit wiring duct or when mounted separately, delivering greater design flexibility to satisfy a wide range of applications
Bonding clip ̂
Segmented design Speeds installation by allowing section(s) of the shield to be cut and snapped off at intervals to easily size shield to length, with minimal deburring
Vertical wall slots Allow wires to cross the barrier at 90° when necessary, providing greater design flexibility
Horizontal cable tie slots Allow wire bundles to be held in place using cable ties to optimize cable management and aesthetics
Zinc-plated steel and durable black powder-coated surfaces
Durable powder-coated vertical surfaces for smooth edges; uncoated, corrosion resistant, zinc-plated surface in shield contact area with sub-panel, ensures continuity for proper bond to ground
When installing the shield inside a wiring duct, the bonding clip maintains electrical continuity between the panel and shield for optimal noise mitigation and aesthetics
High-quality Panduit PVC wiring duct baseu
Slotted sidewalls with horizontal bridge connectors
Continuous foil shield* **^‡
*Recommendations for distance separation between noisy and low-noise zones are referenced in IEEE 1100 Emerald Book, Recommended Practice for Powering and Grounding Electronic Equipment. Consult the component manufacturer for specific wire segregation distance requirements.**PanelMax™ Shielded Wiring Duct and Noise Shield deliver approximately 20dB of noise reduction across common industrial noise frequencies at 30mm wire separation with an approximate 1 meter coupling length.^The shielded wiring duct or noise shield, bonding clip (if used) and enclosure must be electrically bonded to ground for the shield to be effective (see Panduit installation instructions EP001, for shielded wiring duct or RW260, for noise shield).‡For reference on optimal control panel layouts see the Panduit Industrial Ethernet Physical Infrastructure Reference Architecture Design Guide.uUL Recognized continuous use temperature: 122°F (50°C)
Product Bulletin
Panduct® PanelMax™
Shielded Wiring Duct and Noise Shield
PanelMax™
Shielded Wiring Duct PanelMax™
Noise Shield
One of the core issues affecting the performance and reliability of industrial control systems is electrical noise emitted from devices. This electrical noise can create voltage spikes in victim wiring, affecting component performance (as figure at left depicts).
Multi-Layered Noise Prevention and MitigationPanduit recommends following a multi-layered electrical noise prevention and mitigation strategy that also optimizes control panel space utilization. This strategy includes grounding/bonding, segregation, shielding, and filtering practices to provide optimal protection. This product bulletin focuses on noise mitigation via shielded wiring duct and noise shield products. Refer to Panduit’s white paper WP-14, Optimizing Control Panel Layouts for Noise Mitigation in Factory Automation Systems, for greater detail on other strategy recommendations.
Potential noise emitters/wiring• Variable frequency and servo motor drives• Switching power supplies• Contact switching of coils and solenoid valves
Sensitive devices/wiring• Communications/network wiring (UTP Ethernet, RS232)• High-speed counting signals• Controllers• Microprocessor based devices
Business Risks• Productivity loss• Downtime• Maintenance/repair costs• Device replacement costs• Troubleshooting costs
Proper noise mitigation and panel layout practices help to ensure system productivity, quality, and safety. Panel designers have historically used air spacing between components and wire pathways for noise mitigation, per IEEE recommendations. With Panduit® PanelMax™ Shielded Wiring Duct and Noise Shield, panel designers can provide noise mitigation with reduced air spacing requirements allowing for a space optimized control panel layout.
Source
Victim
Considering Shielded Cables vs. Shielded Wiring Duct and Noise Shield
An alternative to shielded wiring duct or noise shield is to consider an increased use of shielded cables, such as shielded twisted pair network cables and shielded control cables. Shielded cables provide superior noise mitigation and noise voltage reduction, but at a typically higher premium and installed cost than unshielded cables. Panduit® PanelMax™ Shielded Wiring Duct and Noise Shield add project value by providing sufficient noise mitigation at a lower premium than a shielded cable solution.
Shielded Wiring Duct and Noise Shield advantages:
• Routing 10 standard unshielded cables in shielded wiring duct has up to a 35% lower purchased cost vs. 10 shielded cables routed in conventional wiring duct • Shielded wiring duct and noise shield provide an effective noise mitigation solution when a shielded cable option is not available or is difficult to source
Product Selection Guide
2
N o i s e a n d I t s E f f e c t s o n I n d u s t r i a l C o n t r o l s
N o i s e a n d I t s E f f e c t s o n I n d u s t r i a l C o n t r o l s
A conventional panel layout uses air spacing between pathways and components as a strategy to mitigate noise. Duct color is used to indicate noisy (gray) and clean (white) pathways.
The strategy is to keep sensitive and potentially noisy wiring/cabling separated to mitigate noise:
Control and potentially sensitive wiring is routed in “clean” pathways (white color).
Power and potentially noise-emitting wiring is routed in “noisy” pathways (gray color).
A 6-inch distance is used between parallel noisy and clean wire pathways to mitigate noise coupling.^
Problems to resolve:
• Difficult to lay out and maintain segregated pathways throughout design • Distance spacing often requires a larger panel size to implement, significantly increasing panel costs and enclosure footprint requirements • Distance separation between wire pathways can be compromised due to panel space constraints
^As a best wiring practice, where necessary, sensitive and potentially noisy wires should cross only at 90° in order to minimize the coupled length between wires.
DISTANCEBETWEEN WIREPATHWAYS (6-inch minimum)
Motor Control and Networked Programmable Automation Controller (PAC) Panel
1
2
3
1
2
3
Sensitive Noisy
C o n v e n t i o n a l P a n e l L a y o u t
3
An optimized panel layout uses PanelMax™ Shielded Wiring Duct and Noise Shield to provide noise mitigation with reduceddistance spacing required between clean and noisy pathways. PanelMax™ DIN Rail Wiring Duct is also implemented to provide additional panel space savings.
The strategy is to shield, mitigating noise between sensitive and potentially noisy wiring/cabling while reducing panel space:
Control and potentially sensitive wiring is routed in “clean” pathways (white color).
Power and potentially noisy wiring is routed in “noisy” pathways or shielded wiring duct (gray color).
Conventional wiring duct contains motor cabling. Noise shield is mounted separately to shield control and network cabling.
Optionally, noise shield is mounted inside shielded wiring duct to segregate and shield sensitive cabling from noise. Shielded wiring duct mitigates potential noise emission from cabling inside the duct near clean pathways.
Shielded wiring duct mitigates potential noise emission from motor drives onto the PAC device and sensitive wiring connections.
PanelMax™ DIN Rail Wiring Duct is added to the design to provide additional space savings.t
Layout Benefits:
• Robust noise mitigation is achieved • Shielded wiring duct and noise shield reduce panel height by over 20% and DIN Rail wiring duct reduces panel width by over 20% resulting in significant enclosure footprint reduction • Net value of space saved in panel/enclosure with cost of PanelMax™ Shielded Wiring Duct and Noise Shield and DIN Rail Wiring Duct is between $1,500 and $5,000n
1 5
2
2
4
4
Noise Shield
ShieldedWiring Duct
Noise Shield
ConventionalWiring Duct
3
6
40%+Space Savings
Sensitive
Noisy
1
2
3
5
6
tSee www.panduit.com for more information on PanelMax™ DIN Rail Wiring Duct (product bulletin WDCB36--SA-ENG).n Material cost savings potential depends on enclosure/panel type selected (e.g., standard NEMA12 steel vs. NEMA4X stainless steel enclosures).
O p t i m i z e d L a y o u t w i t h P a n e l M a x ™ O f f e r i n g
4
Bonding clip allows shield use within wiring duct
Noise shield providesUL508 compliant wire separation
Sensitive wiring
Sensitive communications cable
Vertical wire slots for wire pass-through
Uncoated conductive zinc-plated surface (top/bottom) for electrical bond
Durable black powder coat for smooth edges
Cable tie slotsintegrated into shield for cable management
Durable metallic foil shield covers base and side walls
Horizontal bridge connectors providecontinuity to ground plane
PanelMax™ Noise Shield and Bonding Clips Standard package quantity in kits.
O r d e r i n g I n f o r m a t i o n
PanelMax™ Shielded Wiring DuctUse C2LG6 or C2WH6 cover with shielded wiring duct. Standard package quantity in feet.
Part Number Part Description
Std. Pkg. Qty.
G2X2LG6EMI 2" x 2" PanelMax™ Shielded Wiring Duct; 6-foot length. Foil metal finish includes anti-oxidizing paste. Cover sold separately.
12
G2X3LG6EMI 2" x 3" PanelMax™ Shielded Wiring Duct; 6-foot length. Foil metal finish includes anti-oxidizing paste. Cover sold separately.
12
G2X4LG6EMI 2" x 4" PanelMax™ Shielded Wiring Duct; 6-foot length. Foil metal finish includes anti-oxidizing paste. Cover sold separately.
12
P e r f o r m a n c e C h a r a c t e r i s t i c s
-
-
-
-
-
Noise Shielding Performance
Noi
se S
hiel
ding
E�e
ctiv
enes
s in
dB
0.00
No Shield
Panduit ® PanelMax™
Shielded Products
0 1 2 3 4 5 6 7 8 9 10
-5.00
-10.00
-15.00
-20.0090%NVR*
-25.00
Frequency in Mhz
Relative noise reduction in decibels over frequency range of Panduit® PanelMax™ Shielded Wiring Duct and Noise Shield
PanelMax™ Shielded Wiring Duct and Noise Shield deliver approximately 20dB of noise reduction across common industrial noise frequencies at 30mm wire separation with an approximate 1-meter coupling length.
*NVR (Noise Voltage Reduction percentage).
Potential noise-emitting wiring
Potential noise-emitting wiring
Part Number Part Description
Std. Pkg. Qty.
SD2EMI EMI noise shield kit for 2" height Panduit wiring duct; two 3-foot sections, four bonding clips, and anti-oxidizing paste.
1
SD3EMI EMI noise shield kit for 3" height Panduit wiring duct; two 3-foot sections, four bonding clips, and anti-oxidizing paste.
1
SD4EMI EMI noise shield kit for 4" height Panduit wiring duct; two 3-foot sections, four bonding clips, and anti-oxidizing paste.
1
SDCLIP Noise shield replacement bonding clips – 2 clips. 1
O r d e r i n g I n f o r m a t i o n
5
.70 [17.8]
.84 [21.3]
.84 [21.3]
.57 [14.5]
.48 [12.1]B
C
A
H D
E
FT
.33 [8.4]
.96 [24.4]
X
.80 [20.3]
2.00 [50.8]
.30 [7.6]
1.00 [25.4]
1.00 [25.4] 1.50
[38.1]
2.62 [66.6]
.20 [5.0]
GAP.16 [4.2]
.52 [13.3]
.20 [5.0] TYP.
.50 [12.7] TYP.
.75 [19.0]
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADAMarkham, [email protected]: 800.777.3300
PANDUIT EUROPE LTD.London, [email protected]: 44.20.8601.7200
PANDUIT JAPANTokyo, [email protected]: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.Republic of [email protected]: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.Victoria, [email protected]: 61.3.9794.9020
PANDUIT LATIN AMERICAGuadalajara, [email protected]: 52.33.3777.6000
NR1 Nylon RivetFor use with TNR tool
TNR Nylon Rivet Installation Tool
Hand-held tool for easy rivet installation
DNT-100 Notching ToolNotches duct sidewalls tobottom scoreline for tees
and corners
CWST ToolSnipping tool cuts
conductors flush for improved performance
DCT ToolProvides a smooth
burr-free cut on both wiring duct and cover
PanelMax ™ Noise Shield
PanelMax ™ Shielded Wiring Duct
PanelMax ™ Shielded Wiring Duct Wire Fill
Sidewall: SD3EMI shown.SD2EMI sidewall features one pair of cable tie slots per section. Bonding clip (for use with
wiring duct).Bottom view.
2x2 sidewall2x3 sidewall 2x4 sidewall
R e l a t e d p r o d u c t s
Table shows maximum wire fill based on 50% of duct internal cross sectional area. Formula = Nominal Area / 1.75xD2. All dimensions represent typical outer cable diameter in inches.
Part NumberNominalArea in2
Electrical Communication
8 AWG10
AWG12
AWG14
AWG16
AWG18
AWG22
AWG23
AWG23/24AWG
24AWG
FiberCable
0.216 0.164 0.130 0.141 0.152 0.111 0.124 0.133 0.096 0.111 0.118 0.084 0.100 0.106 0.085 0.330 0.250 0.190 0.118
THHN THHN THHN MTW MTW THHN MTW MTW TFFN MTW MTW TFFN MTW MTW MTW Cat 6A Cat 6 Cat 5e 3.0 mmG2X2LG6EMI 4.000 48 84 135 114 98 185 148 129 248 185 164 323 228 203 316 20 36 63 163G2X3LG6EMI 6.000 73 127 202 172 148 278 222 193 372 278 246 485 342 305 474 31 54 94 245G2X4LG6EMI 8.000 97 169 270 229 197 371 297 258 496 371 328 647 457 406 632 41 73 126 327
.50 [12.7] TYP..20 [5.0] TYP.
4.00[101.6] TYP.
2.00[50.8]
K K
C L
Part Number
Dimensions – Inches (mm)
A B C D E F H K T
G2X2LG6EMI2.25
(57.2)2.12
(53.8)2.25
(57.2)1.61
(41.0)0.31(7.9)
0.80(20.3)
2.00(50.8)
0.50(12.7)
0.08(2.0)
G2X3LG6EMI2.25
(57.2)3.12
(79.2)2.25
(57.2)2.64
(67.0)0.31(7.9)
1.00(25.4)
3.00(76.2)
0.50(12.7)
0.10(2.4)
G2X4LG6EMI2.25
(57.2)4.10
(104.1)2.25
(57.2)3.62
(91.9)0.31(7.9)
1.00(25.4)
4.00(101.6)
0.50(12.7)
0.11(2.7)
Part No. X — Inches (mm)SD2EMI 1.82 (46.1)SD3EMI 2.88 (73.2)SD4EMI 3.86 (98.2)
©2016 Panduit Corp. ALL RIGHTS RESERVED.
WDCB26--SA-ENGreplaces SA-WDCB23
3/2016Contact Customer Service by email: [email protected] by phone: 800.777.3300 and reference WDCB26
Visit us at www.panduit.comFor more information
T e c h n i c a l I n f o r m a t i o n