Date post: | 04-Dec-2014 |
Category: |
Technology |
Upload: | panduit |
View: | 260 times |
Download: | 2 times |
04/09/2023
1
Panduit IA UPS Benefits for Zone Networks
2
Panduit IA UPS Benefits for Zone Networks
• Improved availability– Saves minutes of switch restart
time after brief power interruptions
• Lower risk of downtime– No Battery eliminates the #1
cause of UPS failures– Maintenance-free removes
dependency on preventative maintenance
Top root causes of downtime cited by data center professionals. Totals exceed 100 percent because data center professionals cited multiple root-causes over a period of two years.
3
Panduit IA UPS Benefits for Zone Networks
• Lower Cost of Ownership– Maintenance-free saves time
and costs of battery inspections, testing, replacement and disposal
– Longer life, up to 20 years, with less derating at high temperatures
4
Panduit IA UPS Benefits for Zone Networks
• Improved Device Management – No proprietary software to download, install, configure, learn and support– No need to “visit” each device with a laptop to check health– Remote management from office, plant floor or mobile devices– Multiple device management– Plug-and-play on FactoryTalk® networks
• Predictive Monitoring– Hold Time based on actual load consumption, whether in primary or secondary
power supply path– “Life Time” remaining to 80% of original capacity, integrates temperature
variations over time
FactoryTalk® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.
5
Panduit IA UPS Benefits for Zone Networks
• Better Integration– Smaller width saves valuable space on the DIN rail– Single device installs more easily without interconnections– Wide operating temperature from -40 to +60° C (-40 to +140°F)– No HazMat disposal of lead acid batteries– No chance of Hydrogen outgassing, no need to vent
• Zone Monitoring– Power Supply A and B outputs, and load current– Proxy for enclosure inside temperature
6
UPS Faceplate on A-B HMI
• Panduit UPS is the only DC UPS with an
Ethernet interface
– Alternatives are expensive rack mount, AC units
intended for Data Center environments
– Allows remote monitoring Zone Network “health” –
Power Supplies and Temperature
• EtherNet/IP CONFORMANCE TESTED™ for
easy plug-and-play integration with Rockwell
Automation FactoryTalk® network devices
– EtherNet/IP™ and FactoryTalk® Network support
files downloadable
Remote Management withFactoryTalk® View Faceplate
FactoryTalk® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.
EtherNet/IP CONFORMANCE TESTED™ is a certification mark of ODVA.
EtherNET/IP trademark of ODVA.