Date post: | 30-Mar-2015 |
Category: |
Documents |
Upload: | britney-woolworth |
View: | 212 times |
Download: | 0 times |
Patea Freezing Works Asbestos Overview of Quantities and Locations
February 2009
1. Asbestos-containing fragmented debris present from base of all buildings out to approximately 20 metres. This material is found
on bitumen roadways and grassed areas .
2. Asbestos-containing roof debris and asbestos-contaminated pumice identified throughout the former freezer and cooling
section of the site. Approximately 10,000 square metres
3. Asbestos-containing roof debris and asbestos-contaminated pumice identified throughout the former freezer and cooling
section of the site.
4. Asbestos-containing roof debris and asbestos-contaminated pumice identified throughout the former freezer and cooling
section of the site.
5. Asbestos-containing roof debris and asbestos-contaminated pumice identified throughout the former freezer and cooling
section of the site.
6. Asbestos-containing roof debris identified in the ground level of the Freezing section of the site. Hot spots beneath ceiling
penetrations.
7. Asbestos-containing roof debris identified in the upper level of the Freezing section of the site.
Approximately 2,100 square metres
8. Asbestos-containing roof debris identified in the upper level of the Freezing section of the site.
9. Asbestos-containing fibrous wall sheet debris identified in and around the Power House.
Approximately 1,200 square metres
10. Asbestos-containing fibrous wall sheet debris identified in and around the Power House.
11. Asbestos-containing fibrous wall sheet debris found in and around the Power House.
12. Asbestos-containing corrugated roof and walls identified in the Boiler House.
Approximately 1,000 square metres
13. Friable asbestos pipework insulation and debris identified in the Boiler House.
Approximately 20 linear metres
14. Friable asbestos pipework insulation and rope gaskets identified in the Boiler House.
15. Friable asbestos insulation and debris identified in the Boiler House. Eight Dome Ends.
Allowance to be made for the cleaning of all surfaces in this area.
16. Asbestos-containing fibrous wall sheeting identified in the external stairs on the south side of the site.
Approximately 250 square metres
17. Asbestos-containing corrugated fibrous roofing, debris and stored sheeting identified in the Casings floor area at the south
side of the site. Approximately 2,100 square metres
17a. Asbestos-containing fibrous wall and ceiling lining and debris identified in the Pelts area at the south side of the site.
Approximately 200 square metres
18. Asbestos-containing corrugated roofing identified in the Wool Section and Manure Works at the south east corner of the site.
Approximately 2,500 square metres
18a. Asbestos-containing corrugated roofing identified in the Wool Section and Manure Works at the south east corner of the
site.
18b. Asbestos-containing corrugated roofing identified in the Wool Section and Manure Works at the south east corner of the
site.
19. Friable asbestos-containing rope wrap and insulation debris identified in the Fellmongery section in the eastern area of the
site.Hot Spots.
19a. Asbestos-containing corrugated roof identified in the Paint
Mix and Fellmongery section in the eastern area of the site. Approximately 500 square metres
20. Asbestos-containing corrugated roof and debris identified in the Paint Mix and Fellmongery section in the eastern area of the
site.
21. Asbestos-containing fibrous cement sheet walls, eave lining and roof identified in the Paint Mix and Fellmongery section in the
eastern area of the site. Approximately 800 square metres
22. Asbestos-containing corrugated roof and debris identified in the Paint Mix and Fellmongery section in the eastern area of the
site.
23. Asbestos-containing fibrous wall lining identified internal and external ground floor in the Mutton Slaughter.
Approximately 500 square metres
24. Asbestos-containing fibrous wall lining identified internal and external of the ground floor in Mutton Slaughter section.
25. Asbestos-containing fibrous wall lining identified internal and external of the ground floor in the Mutton Slaughter section.
26. Asbestos-containing fibrous wall lining identified internal and external of the ground floor in the Mutton Slaughter section.
27. Asbestos-containing fibrous wall lining and roofing identified
in the upper level of the Beef Slaughter section.
28. Asbestos-containing corrugated roof debris identified in the
upper level of Mutton Slaughter section of the site.
29. Asbestos-containing roof debris and asbestos-contaminated ash identified throughout the upper level of the former Mutton
Slaughter.
30. Asbestos-containing roof debris and asbestos-contaminated ash identified throughout the upper level of the former Mutton
Slaughter.
31. Asbestos-containing corrugated roof and debris identified throughout the upper level of Mutton and Beef Slaughter area of
the site.
32. Asbestos-containing corrugated roof and debris identified throughout the upper level of Mutton and Beef Slaughter area of
the site.
33. Asbestos-containing corrugated roof and debris identified in
the Mutton and Beef Slaughter area of the site.
34. Asbestos-containing fibrous wall lining identified in the accessible areas of the Ground Floor adjacent to the Freezing and
Cold Store Approximately 400 square metres
35. Asbestos-containing fibrous wall lining identified in the accessible areas of the Ground Floor adjacent to the Freezing and
Cold Store
36. Asbestos-containing fibrous wall lining identified in the accessible areas of the Ground Floor adjacent to the Freezing and
Cold Store
37. Asbestos-containing fibrous wall lining identified in the accessible areas of the Ground Floor adjacent to the Freezing and
Cold Store
38. Asbestos-containing corrugated fibrous walls and roof identified in the Warehouse
Approximately 1,000 square metres
39. Asbestos-containing corrugated fibrous walls and roof identified in the Warehouse
40. Asbestos-containing corrugated fibrous roofing and flat fibrous sheet walls, eaves and gable ends identified in the Former
Butcher ShopApproximately 170 square metres
41. Asbestos-containing corrugated fibrous roofing and flat fibrous sheet walls, eaves and gable ends identified in the Former
Butcher Shop
42. Asbestos-containing fibrous internal walls, ceilings, eaves and porch ceiling identified in the Stockman's Quarters
Approximately 180 square metres
43. Asbestos-containing fibrous internal walls, ceilings, eaves and porch ceiling identified in the Stockman's Quarters
44. Asbestos-containing fibrous internal walls, ceilings, eaves and porch ceiling identified in the Stockman's Quarters
45. Asbestos-containing corrugated fibrous roofing, asbestos- containing walls, ceiling and eave lining indentified in the Pump
House.Approximately 200 square metres
46. Asbestos-containing corrugated fibrous roofing, asbestos-containing walls, ceiling and eave lining indentified in the Pump
House.
47. Asbestos-containing corrugated roof debris identified at the south east corner of the site.
Approximately 25 square metres
48. Potential for asbestos-containing materials to be present in fill areas of the site. These areas can be found at the southern end of
the site.
49. Unstable building structures are indentified throughout the site.
50. Unstable building structures are indentified throughout the site.
51. Unstable building structures are indentified throughout the site.
52. Unstable building structures are indentified throughout the site.
Non-Friable Asbestos (asbestos cement sheeting, walls, roofs, eaves and ceilings. Much is severely
damaged and will be handled as if it is friable)
Location Area (square metres)
Freezer and Cooling Sections 10,000Upper level Freezer Section 2,100Power House 1,200Boiler House 1,000External stairs, south side of site 250Casings Floor 2,100Pelts 200Wool and Manure Works 2,500Paint Mix and Fellmongery 1,300Mutton Slaughter, Lower 500Mutton Slaughter, Beef Slaughter, Cooling Floor-Upper Levels 3,000(combined)Freezing and Cold Store, Ground Level 400
Non-Friable Asbestos (asbestos cement sheeting, walls, roofs, eaves and ceilings. Much is severely
damaged and will be handled as if it is friable) Cont.
Location Area (square metres)
Warehouse 1,000Butcher Shop 170Stockman’s Quarters 180Pump House 200South East corner of the site, stockpiled sheeting and 25debris
TOTAL 26,125 m²(Provided in good faith as an estimate only. Quantities are not
contractually binding to the Principal or Consultant)
Friable Asbestos (asbestos lagging/insulation, asbestos rope. Note some of the fire damaged sheeting
will be handled as if it is friable).
Location Quantity
Boiler House, asbestos lagging to end sections of calorifiers 8 off
(Pressure vessels)
Boiler House, asbestos pipe lagging (some debris) 20 Linear metres
Fellmongery and Paint Mix, asbestos rope and insulation minor quantities
only sighted