T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM
Pattern Play - In StockAcoustical/Decorative Panels
IT
CO
LL
OC
EC
ILD
ET
AS
ON
SIZE: Acoustical: WPVEP319 and WPVEP320: 11 ¾" x 47 ¾"; WPVEP321: 11 ¾" x 46 ¾"; WPVEP322: 23 ½" x 23 ½"; Decorative: WPVEP324: 17.14" x 45.15"; WPVEP325: 16.05" x 41.69"; WPVEP326: 24" x 24"; WPVEP323: 14" x 56"; WPVEP327: 23 ½" x 23 ½"THICKNESS: Acoustical: WPVEP319 and WPVEP320: 52.3mm; WPVEP321: 52.1mm; WPVEP322: 51.5mm; Decorative: WPVEP323: 10.6mm (including backing); WPVEP324 - WPVEP327: 7mm (including backing)CONSTRUCTION: Acoustical: WPVEP319 and WPVEP320: 4 layers - Wood: 3.3mm - 4.8mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; WPVEP321: 4 layers - Wood: 4.6mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; WPVEP322: 4 layers - Wood: 4mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; Decorative: WPVEP323: 6mm Russian Birch; WPVEP324 - WPVEP327: 3mm FibrexFINISH: 10% sheen UV VarnishSPECIES: WPVEP319, WPVEP321, WPVEP322, WPVEP323, WPVEP324, WPVEP326 and WPVEP327: White Oak veneer; WPVEP320 and WPVEP325: Walnut veneerINSTALLATION: Acoustical: Glue and nail over plywood or drywall only; Decorative: Interlocking, Glue and Finishing NailsHEALTH AND WELLNESS: Antimicrobial protective coating• Corner moldings available• Movable partitions - acoustical or decorative panels can be customized and fabricated to your specifications, contact [email protected]• No VOC emissions• Class A Fire Rated (upon request), minimums may apply• When Fire Rated, the antimicrobial protective coating will not be put on• Acoustical: Sound Absorbing, NRC = 0.66• Can contribute to LEED®
• In stock products are subject to availability• Please note that variations in color and texture may occur due to the nature of the material
SPECIFICATIONS
View collection web page for the complete offering including additional product options, corresponding Spec ID# and updates.
Formation - White OakWPVEP319
Cuboid - WalnutWPVEP325
Formation - WalnutWPVEP320
Contour - White OakWPVEP326
Ziggurat - White OakWPVEP321
Linear - White OakWPVEP322
Ziggurat - White OakAcoustical: WPVEP321Decorative: WPVEP323
Cuboid - White OakWPVEP324
Linear - White OakAcoustical: WPVEP322Decorative: WPVEP327
The sense of hand is apparent in each of the expressive patterns from our newest wood panel offering, Pattern Play Acoustical/Decorative Panels: Cuboid, Contour, Linear, Ziggurat and Formation. All are made from natural walnut and white oak wood veneers with an MDF core that have an antimicrobial protective coating and share an interlocking installation method with corner trims available. Linear, Ziggurat and Formation are enhanced with a four layer construction to provide a dimensional and distinctly designed acoustical panel. Ziggurat and Linear are available with the acoustical backing option or as a decorative veneer while Cuboid and Contour are solely decorative panels. These playful patterns point to the nuances for today's spaces aesthetically, acoustically and with a focus on wellness.
Acoustical Backing:
Decorative Veneer:
Acoustical Backing or Decorative Veneer:
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
SINSTALLATION METHODWPVEP326
ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.
PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.
INSTALLATION INSTRUCTIONSTOOLS:
• Vertical adhesive through ASI• Spec ID# FLDTC025
• Caulking gun• Electric mitre saw• Tablesaw
• Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder
STEP 1:If you are using moldings, mark required space around the perimeter of installation area.
STEP 2:Apply a line of vertical adhesive through ASI, Spec ID# FLDTC025 in the form of a rectangle (1/2" [1.3 cm] from edges) and an X inside the rectangle.
STEP 4: Nail panel in place with #23 gauge finish nails on the exposed backing. NEVER NAIL DIRECTLY ON FACE OF WALL PANEL.
•STEP 5: Installation of subsequent panels
•Repeat Step 2
•Align panel B against panel ARepeat Step 4
MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.
First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
STEP 3:Position first panel at lower left of wall. Make sure the exposed backing are facing up and right. If using moldings, position in area designated in step 1.
x = #23
A B
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
S
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
INSTALLATION METHOD CONT.WPVEP326
STEP 6: End a rowCut any excess of the wall panel to be flush with the edge of the wall.
STEP 7: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.
STEP 8: Insert molding in previously designated area if required.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
SINSTALLATION METHODWPVEP323
ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.
PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.
INSTALLATION INSTRUCTIONS
TOOLS:
• Vertical adhesive through ASI• Spec ID# FLDTC025
• Caulking gun• Electric mitre saw• Tablesaw
• Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder
STEP 1:If you are using moldings, mark required space around the perimeter of installation area.
STEP 2:A On back of panel, apply a line of vertical adhesive 1/2" (1.3cm) from all edges and forming an X in the center.
STEP 4: Nail panel in place with #23 gauge finish nails on the exposed backing. NEVER NAIL DIRECTLY ON FACE OF WALL PANEL.
•STEP 5: Installation of subsequent panels
•Repeat Step 2
•Align panel B against panel ARepeat Step 4
MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.
First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
STEP 3:Position first panel at lower left of wall. Make sure the exposed backing are facing up and right. If using moldings, position in area designated in step 1.
A
x
xx
xxxxx
x = #23
xx x x
x x x
Panel BPanel A
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
S
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
INSTALLATION METHOD CONT.WPVEP323
STEP 6: End a rowCut any excess of the wall panel to be flush with the edge of the wall.
STEP 7: Start a new rowUse remaining piece from the previous row making sure the pattern aligns.
STEP 8: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.
STEP 9: Insert molding in previously designated area if required.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
SINSTALLATION METHODWPVEP327
ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.
PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.
INSTALLATION INSTRUCTIONS
TOOLS:
• Vertical adhesive through ASI• Spec ID# FLDTC025
• Caulking gun• Electric mitre saw• Tablesaw
• Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder
STEP 1:If you are using moldings, mark required space around the perimeter of installation area.
STEP 2:On back of panel, apply a line of vertical adhesive 1/2" (1.3cm) from all edges and forming an X in the center.
STEP 4: Nail panel in place with #23 gauge finish nails on the exposed backing. NEVER NAIL DIRECTLY ON FACE OF WALL PANEL.
STEP 5: Installation of subsequent panels• Repeat Step 2• Align panel B against panel A• Repeat nailing procedure
MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.
First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
STEP 3:Position first panel at lower left of wall. If using moldings, position in area designated in Step 1.
x = #23
x x x x
xx
x
xx
xx x x x
A B
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
S
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
INSTALLATION METHOD CONT.WPVEP327
STEP 6: End a rowCut any excess of the wall panel to be flush with the edge of the wall.
STEP 7: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.
STEP 8: Insert molding in previously designated area if required.
SUGGESTED INSTALL:
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
SINSTALLATION METHODWPVEP324 and WPVEP325
ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.
PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.
INSTALLATION INSTRUCTIONS
TOOLS:
• Vertical adhesive through ASI• Spec ID# FLDTC025
• Caulking gun• Electric mitre saw• Tablesaw
• Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder
STEP 1:If you are using moldings, mark required space around the perimeter of installation area.
STEP 2:Cut the excess wood to be straight with the backing.
MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.
First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
STEP 3:A. Position first panel at lower left of wall. If
using moldings, position in area designated inStep 1.
B. Apply glue on exposed backing.
A
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
SINSTALLATION METHOD CONT.WPVEP324 and WPVEP325
STEP 5:Nail panel in place with #23 gauge nails on the exposed backing and on the hollow part of the wood at the bottom.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
STEP 7:Cut any excess of wall panel flush with edge of wall.
STEP 8: Start a new rowUse remaining piece from previous row making sure the pattern aligns.
STEP 9: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.
STEP 10:Insert molding in previously designated area if required.
x x x x
x
xxxx
STEP 4:Position first panel at lower left of wall. If using moldings, position in area designated in Step 1.
STEP 6: Installation of subsequent panels• Cut the excess of the wood at the bottom of the
wall panel• Repeat step 3• Insert panel B into panel A• Repeat step 5
PANEL A PANEL B
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
SINSTALLATION METHODWPVEP319 and WPVEP320
ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.
PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.
INSTALLATION INSTRUCTIONS
TOOLS:
• Vertical adhesive through ASI• Spec ID# FLDTC025
• Caulking gun• Electric mitre saw• Tablesaw
• Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder
STEP 1:If you are using moldings, mark required space around the perimeter of installation area.
STEP 2:Cut a minimum of 6" (15cm) from male side of panel to form your starting panel.
MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.
First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
STEP 3:A. Position first panel at lower left of wall. If
using moldings, position in area designated inStep 1.
A
min 6” (15 cm)
STEP 4:Position first panel at lower left of wall.
STEP 5: Nail panel in place with #18 gauge finish.
A. Nail at the top and right at an angle on theback layer of MDF.
B. Nail directly into the felt between the last 2bottom rows. The nail will go through theunder layers to the MDF.
x x x
x = #18
T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
S
The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.
INSTALLATION METHOD CONT.WPVEP319 and WPVEP320
STEP 6: Installation of subsequent panels• Repeat Step 3• Apply glue to the back of the female wood slats. Avoid
overflow that could spread on the felt.• Insert panel B into panel A
Repeat Step 5
NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.
Panel A Panel B
STEP 7: End a rowCut any excess of wall panel flush with edge of wall.
STEP 8: Start a new rowUse remaining piece from previous row or repeat Step 2. Repeat Steps 3, 4, and 5.
STEP 9: Last rowCut panels of last row lengthwise to fit available space.
STEP 10: Insert molding in previously designated area if required.
CO
LL
EC
TIO
N D
ET
AIL
SMAINTENANCEClean-up recommendations: a regular dusting with a soft cloth or a feather duster.
WARRANTYASI | Architectural Systems, Inc. guarantees Pattern Play - Acoustical/Decorative Panels against manufacturing defects. If, upon opening a box, a panel is defective or fails to meet Architectural Systems, Inc. quality standards, the consumer may return the panel to ASI | Architectural Systems, Inc. for replacement.
This product is flammable and its use near an important heating source (such as a gas fireplace, solid burning appliances, slow burning stove) is not recommended. Please check the latest construction regulations or the nearest fire department in your locality. In most cases, the use of decorative wood walls is forbidden near these heating sources.
A panel with glue applied to its back or an installed panel (nailed) is deemed accepted and cannot be claimed under warranty. An unglued lamination may be glued back together using vertical adhesive through ASI, Spec ID# FLDTC025. Given the nature of wood, it is possible that Interwoven Eco-Panels may exhibit color variations from one panel to the next or from one production lot to the next. We recommend that you arrange the panels on the wall based on your personal color preferences. Such variations may not be claimed under warranty.
Before installing a panel, check the fit prior to spreading glue on the panel. If a panel fails to interlock properly, attempt to position it on a panel in another row. If the Interwoven Eco-Panel once again, fails to interlock properly, please return it to Architectural Systems, Inc. for replacement.
ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to Interwoven Eco-Panels installation guidelines and are maintained in an environment where ambient humidity ranges between 37% and 45%. Failure to comply with installation and maintenance instructions and with recognized trade techniques could void the application of these warranties.
For questions regarding the interpretation of the warranty, contact ASI | Architectural Systems, [email protected]
T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM
CO
LL
EC
TIO
N D
ET
AIL
S
T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM
TECHNICAL DATA
WPVEP327
Wood veneer with an MDF
core
23.5” / 59.69 cm
23.5” / 59.69 cm
4 panels / box – 15.3 ft2 / box
Fibrex 3 mm
Wood veneer
with an MDF core
4 mm
45.15” / 114.68 cm
17.14” / 43.54 cm
4 panels / box – 21.48 ft2 / box
Russian birch 3 mm
4.5” / 11.4 cm
WPVEP324
CO
LL
EC
TIO
N D
ET
AIL
S
T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM
TECHNICAL DATA CONT.
Wood veneer with an MDF core
4.6 mm
Russian Birch6 mm
56” / 142.24 cm
14” / 35.56 cm
4 panels / box – 21.7 ft2 / box
WPVEP323
Wood veneer with an MDF core
4 mmFibrex 3 mm
41.69” / 105.8 cm
16.05” / 40.7 cm
4.5” / 11.4 cm
4 panels / box – 18.6 ft2 / box
WPVEP325
CO
LL
EC
TIO
N D
ET
AIL
S
T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM
TECHNICAL DATA CONT.
WPVEP326
Wood veneer with an MDF core
4 mm
24” / 60.96 cm
Piece 1 Piece 2 Piece 3
Piece 4 Piece 5 Piece 6
24” / 60.96 cm
6 panels / box – 24 ft2 / box
Fibrex 3 mm
installationmaintenancewarrantytechnical