+ All Categories
Home > Documents > PB 24SM - Farnell

PB 24SM - Farnell

Date post: 01-Mar-2022
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
3
Input and output modules accepted interchangeably Operate with 5, 15 or 24 volt logic supplies Pin retaining system for “SM” series minature modules Plug-compatible logic connections Screw terminal barrier block for load connections Resident pull-up resistors 5 amp field-replaceable fuses (LITTLEFUSE #251005 or equivalent) All even-numbered logic connections are logic ground PB-24SM MECHANICAL SPECIFICATIONS LEDs indicate logic status MOUNTING BOARD Rev. 020410 3.45 (67,6) 5.1 (129,5) 3.45 (87,6) 3.05 (77,5) 3.75 (95,3) 0.35 (8,9) 13.0 (330,2) 4.0 (101,6) 4.0 (101,6) 4.0 (101,6) 0.5 (12,7) 1.88 (47,6) 0.75 (19,1) Y AC INPUT W DC INPUT B AC OUTPUT R DC OUTPUT 1 2 3 4 5 6 7 8 910111213141516 17181920212223242526272829303132 33343536373839404142434445464748 + - 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 (see notes 2,3,4) REPLACEABLE 5 AMP LINE FUSE (24) (see note 6) CRYDOM DIGITAL I/O MODULES SOLD SEPERATELY OPTIONAL HOLD DOWN BAR KIT (see note 7) LED STATUS INDICATOR (24) (24) PULL UP RESISTOR 3.3K OHM SIGNAL INPUT/OUTPUT 50 LOGIC SUPPLY (see note 2) REPLACEABLE 1 AMP LOGIC SUPPLY FUSE (see note 5) SWAGED STANDOFF THRU HOLE 0.15 (3,8) DIA. (8) (OR EQUIVALENT) FEMALE. SCREW-TERMINAL PLUG-IN CONNECTOR. (OR EQUIVALENT) MALE CONNECTOR AND MATING PHOENIX MSTBVA 1.5/16-ST-5.08 SUFFIX "B" FOR BOARD-MOUNTED PHOENIX MSTBVA 1.5/16-G-5.08 MSTBVA 1.5/16-G-5.08 (OR EQUIVALENT) MALE CONNECTOR. SPECIFY BLOCKS STANDARD. SPECIFY SUFFIX "A" FOR BOARD-MOUNTED PHOENIX 4) PHOENIX MKD51.5 5.08mm SERIES (OR EQUIVALENT) SCREW TERMINAL 3) OPTIONAL JUMPERS ARE AVAILABLE TO INTERCONNECT BARRIER STRIP CABLE CONNECTION. OR EQUIVALENT MALE PIN CONNECTOR FOR PERPENDICULAR-TO-THE-BOARD CONNECTION. SPECIFY SUFFIX 'V' FOR OPTIONAL CIRCUIT ASSEMBLY CA-50H-2B-SR MALE PIN CONNECTOR FOR PARALLEL-TO-THE-BOARD CABLE SPECIFY SUFFIX 'C' FOR OPTIONAL 65823-093 OR EQUIVALENT NOTES: 1) MATING CONNECTOR IS BERG 66317-150 OR EQUIVALENT. ORDER 3 EACH "JM8". 5) LITTLE FUSE 251001 OR EQUIVALENT. 6) LITTLE FUSE 251005 OR EQUIVALENT. TERMINAL STRIP POWER TERMINAL STRIP TRACE (0.1" CENTERS) MALE CARD EDGE (see note 1) 2) 4-40 SCREW TERMINAL STRIPS ACCEPT WIRE SIZES FROM 26 TO 14 AWG. THE CHANNEL FOR INDIVIDUAL MODULES. A PLAIN ALUMINUM CHANNEL WHILE MODEL NO. 11.06.288 PROVIDES POCKETS IN 7) TWO HOLD-DOWN BAR KITS ARE AVAILABLE SEPARATELY. MODEL NO. 11.06.413 EMPLOYS + - DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE: 0.020 ( 0,50) + - 5 4 3 2 1 1 5 9 13 17 21 25 29 33 37 41 45 49 +LOGIC EVEN PINS ALL + - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 5 AMP LINE FUSE (24) I/O MODULE PIN SOCKET LED STATUS INDICATOR (24) PULL UP RESISTOR 3.3K OHM (24) 1 AMP LOGIC SUPPLY FUSE POWER BARRIER STRIP LOGIC SUPPLY BARRIER STRIP EDGE CONN BOTTOM LOGIC GRD SIGNAL INPUT/OUTPUT OR OPTIONAL PIN CONNECTOR 50 TRACE (0.1" CENTERS) MALE CARD EDGE 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1
Transcript

Input and output modules accepted interchangeablyOperate with 5, 15 or 24 volt logic suppliesPin retaining system for “SM” series minature modules

Plug-compatible logic connectionsScrew terminal barrier block for load connectionsResident pull-up resistors5 amp field-replaceable fuses(LITTLEFUSE #251005 or equivalent)

All even-numbered logic connections arelogic ground

PB-24SM

MECHANICAL SPECIFICATIONS

LEDs indicate logic status

MOUNTING BOARD

Rev. 020410

••••

•••

3.45 (67,6)5.1 (129,5)3.45 (87,6)

3.05

(77,

5)

3.75

(95,

3)

0.35 (8,9)

13.0 (330,2)

4.0 (101,6)4.0 (101,6)4.0 (101,6)0.5 (12,7)

1.88 (47,6)

0.75 (19,1)

Y AC INPUTW DC INPUTB AC OUTPUTR DC OUTPUT

1 2 3 4 5 6 7 8 9 10111213141516 17181920212223242526272829303132 33343536373839404142434445464748

+-

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

(see notes 2,3,4)REPLACEABLE 5 AMPLINE FUSE (24)(see note 6)

CRYDOM DIGITALI/O MODULESSOLD SEPERATELY

OPTIONAL HOLD DOWNBAR KIT (see note 7)

LED STATUSINDICATOR (24)

(24)PULL UP RESISTOR3.3K OHM

SIGNAL INPUT/OUTPUT 50LOGIC SUPPLY

(see note 2)

REPLACEABLE1 AMP LOGICSUPPLY FUSE(see note 5)

SWAGED STANDOFFTHRU HOLE 0.15 (3,8) DIA.(8)

(OR EQUIVALENT) FEMALE. SCREW-TERMINAL PLUG-IN CONNECTOR.(OR EQUIVALENT) MALE CONNECTOR AND MATING PHOENIX MSTBVA 1.5/16-ST-5.08SUFFIX "B" FOR BOARD-MOUNTED PHOENIX MSTBVA 1.5/16-G-5.08 MSTBVA 1.5/16-G-5.08 (OR EQUIVALENT) MALE CONNECTOR. SPECIFY

BLOCKS STANDARD. SPECIFY SUFFIX "A" FOR BOARD-MOUNTED PHOENIX 4) PHOENIX MKD51.5 5.08mm SERIES (OR EQUIVALENT) SCREW TERMINAL

3) OPTIONAL JUMPERS ARE AVAILABLE TO INTERCONNECT BARRIER STRIP

CABLE CONNECTION. OR EQUIVALENT MALE PIN CONNECTOR FOR PERPENDICULAR-TO-THE-BOARD CONNECTION. SPECIFY SUFFIX 'V' FOR OPTIONAL CIRCUIT ASSEMBLY CA-50H-2B-SR MALE PIN CONNECTOR FOR PARALLEL-TO-THE-BOARD CABLE SPECIFY SUFFIX 'C' FOR OPTIONAL 65823-093 OR EQUIVALENT

NOTES: 1) MATING CONNECTOR IS BERG 66317-150 OR EQUIVALENT.

ORDER 3 EACH "JM8".

5) LITTLE FUSE 251001 OR EQUIVALENT.6) LITTLE FUSE 251005 OR EQUIVALENT.

TERMINAL STRIP

POWER TERMINAL STRIP

TRACE (0.1" CENTERS) MALECARD EDGE (see note 1)

2) 4-40 SCREW TERMINAL STRIPS ACCEPT WIRE SIZES FROM 26 TO 14 AWG.

THE CHANNEL FOR INDIVIDUAL MODULES. A PLAIN ALUMINUM CHANNEL WHILE MODEL NO. 11.06.288 PROVIDES POCKETS IN

7) TWO HOLD-DOWN BAR KITS ARE AVAILABLE SEPARATELY. MODEL NO. 11.06.413 EMPLOYS

+-DIMENSIONS: INCHES (MILLIMETERS)TOLERANCE: 0.020 ( 0,50)+-

5

43

2

1

159

13172125293337414549+LOGIC

EVENPINS

ALL

+-

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

5 AMP LINE FUSE (24)

I/O MODULE PIN SOCKET

LED STATUS INDICATOR (24) PULL UP RESISTOR 3.3K OHM (24) 1 AMP LOGICSUPPLY FUSE

POWER BARRIER STRIP LOGIC SUPPLY BARRIER STRIP

EDGECONNBOTTOMLOGICGRD

SIGNAL INPUT/OUTPUT

OR OPTIONAL PIN CONNECTOR

50 TRACE (0.1" CENTERS) MALE CARD EDGE

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

5

43

2

1

HAZARD OF ELECTRIC SHOCK,EXPLOSION, OR ARC FLASH. � Disconnect all

power before installing or working with this equipment.

� Verify all connections and replace all covers before turning on power.

Failure to follow theseinstructions will result in death or serious injury.

RIESGO DE DESCARGA ELECTRICA O EXPLOSION.

� Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.

� Verificar todas las conexiones y colocar todas las tapas antes

de energizer el equipo.

Elincumplimientode estas instrucciones puede provocar la muerte o lesiones serias.

RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION � Eteindre

toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil

� Vérifier tousconnections, etremettre tous couverts enolace avant demettre sous

De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses.

GEFAHR EINES ELEKTRISCHEN SCHLAGES ODER EINER EXPLOSION.� Stellen Sie

jeglichen Strom ab, der dieses Gerät versorgt, bevor

Sie an dem Gerät Arbeiten durchführen

� Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen.

Unterlassung dieser Anweisungen können zum Tode oder zu schwerenVerletzungen führen.

RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.� Spenga tutta

l'alimentazione che fornisce questa apparecchiatura prima del lavorare a questa apparecchiatu ra

� Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one

L'omissione di seguire queste istruz ioni provocherà la morte o di lesioni serie

RISCO DEDESCARGAELÉTTRICA OU EXPLOSÃO� Desconectar

o equipamentode toda á energia antesde instalar outrabalhar comeste equipamento

� Verificar todasas conexões e recolocar todasas tampasantes de religaro equipamento

O não cumprimentodestas instruçõespode levar á morteou lesões sérias.

DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO

ANNEX - ENVIROMENTAL INFORMATION


Recommended